PRRES20191606


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20191606
Building Permit - Residential
Certificate of Occupancy
HUNT MIDWEST RESIDENTIAL LLC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED PATIO
06/20/2019
06/25/2019
02/27/2024
Locations
Contacts
HUNT MIDWEST RESIDENTIAL LLC, Address:8300 NE UNDERGROUND DR  
IQ CONSTRUCTION, Address:P O BOX 6423, Phone:(816) 582-8100  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
SAFEHOUSE ELECTRIC COMPANY, Address:P O BOX 1833, Phone:(816) 935-8113  
FIVE STAR PLUMBING INC, Address:P O BOX 452, Phone:(816) 228-8821  
BSHELTON@IQHOMEBUILDERS.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 06/24/2019 06/21/2019
Steve Conrick
Residential Plan Review Approved 06/24/2019 06/20/2019
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 06/25/2019
9110078-Valuation Fee New Single Family $1,151.74 $1,151.74 Paid 06/25/2019
8331401-Water Tap Fee $3,409.00 $3,409.00 Paid 06/25/2019
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 06/25/2019
8350015-Water Meter Fee $408.37 $408.37 Paid 06/25/2019
8331507-Sewer Connection Fee $570.00 $570.00 Paid 06/25/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 7/15/2019 (1:30) 7/15/2019 07/15/2019
Erosion Control Inspection Residential Failed 07/15/2019
Sewer Service Inspection - R Passed 8/13/2019 8/13/2019 08/13/2019
Water Service Inspection - R Partial 8/14/2019 (1:00) 8/14/2019 08/14/2019
Underslab Plumbing Inspection - Residential Passed 8/15/2019 8/15/2019 08/15/2019
Water Service Inspection - R Passed 8/27/2019 08/27/2019
All Rough Inspection - Residential Failed 12/3/2019 12/3/2019 12/03/2019
Misc
Corrective Action Required
12/03/2019
Post site address on lot before further inspections
Electrical Service Inspection Failed 12/3/2019 12/3/2019 12/03/2019
Misc
Corrective Action Required
12/03/2019
No inspection performed due to no site address posted. Post site address on lot before further inspections
Gas Service Inspection - Residential Failed 12/3/2019 12/3/2019 12/03/2019
Misc
Corrective Action Required
12/03/2019
No inspection performed due to no site address posted. Post site address on lot before further inspections
Gas Piping Inspection - Residential Failed 12/3/2019 12/3/2019 12/03/2019
Misc
Corrective Action Required
12/03/2019
No inspection performed due to no site address posted. Post site address on lot before further inspections
All Rough Inspection - Residential Failed 12/4/2019 12/4/2019 12/04/2019
Misc
Corrective Action Required
12/03/2019
No plans on site Erosion control needed for big dirt pile at back of lot
Electrical Service Inspection Failed 12/4/2019 12/4/2019 12/04/2019
Misc
Corrective Action Required
12/03/2019
No plans on site, no inspection performed.
Gas Service Inspection - Residential Failed 12/4/2019 12/4/2019 12/04/2019
Misc
Corrective Action Required
12/03/2019
No plans on site, no inspection performed.
Gas Piping Inspection - Residential Failed 12/4/2019 12/4/2019 12/04/2019
Misc
Corrective Action Required
12/03/2019
No plans on site, no inspection performed.
Erosion Control Inspection Residential Failed 12/05/2019
Misc
Corrective Action Required
12/05/2019
Fix erosion control at front of lot and clean storm inlet. Install erosion control at rear of lot and around dirt pile
All Rough Inspection - Residential Failed 12/5/2019 12/5/2019 12/05/2019
Misc
Corrective Action Required
12/04/2019
- Double joist hanger needed on south side of garage, west of steel beam - support plumbing on south side of garage in joist space - plate bolts missing nuts throughout and loose nuts throughout garage - install plate bolts per code R403.1.6 - fire block electrical penetration east side of kitchen at top plate - Solid fire block heat chase at top plate at first floor next to half bathroom, insulation not allowed - protect water pipes and plumbing at top plates, first floor half bathroom - Support plumbing above main living room - secure gas line to fire place - strap top plates in main living room north side - protect piping at bottom plate in main living room north side - strap top plates above laundry dryer - hook up exhaust fan in master bathroom toilet room - support plumbing above north spare bathroom on second floor - tighten beam post bolt nuts in basement - support HVAC intake and exhaust piping in basement - nail corner studs per code - exterior is caulked and painted, cannot verify nail pattern for siding Do not insulate
Gas Piping Inspection - Residential Passed 12/5/2019 12/5/2019 12/05/2019
Misc
Resolved
12/05/2019
Electrical Service Inspection Passed 12/5/2019 12/5/2019 12/05/2019
Misc
Resolved
12/05/2019
Gas Service Inspection - Residential Passed 12/5/2019 12/5/2019 12/05/2019
Misc
Resolved
12/05/2019
Piers/Caissons Inspection - Residential Passed 12/10/2019 12/10/2019 12/10/2019
All Rough Inspection - Residential Passed 12/11/2019 12/11/2019 12/11/2019
Misc
Resolved
12/11/2019
- Double joist hanger needed on south side of garage, west of steel beam - support plumbing on south side of garage in joist space - plate bolts missing nuts throughout and loose nuts throughout garage - install plate bolts per code R403.1.6 - fire block electrical penetration east side of kitchen at top plate - Solid fire block heat chase at top plate at first floor next to half bathroom, insulation not allowed - protect water pipes and plumbing at top plates, first floor half bathroom - Support plumbing above main living room - secure gas line to fire place - strap top plates in main living room north side - protect piping at bottom plate in main living room north side - strap top plates above laundry dryer - hook up exhaust fan in master bathroom toilet room - support plumbing above north spare bathroom on second floor - tighten beam post bolt nuts in basement - support HVAC intake and exhaust piping in basement - nail corner studs per code - exterior is caulked and painted, cannot verify nail pattern for siding Do not insulate
Driveway Inspection Partial 1/28/2020 1/28/2020 01/28/2020
Misc
Informational
01/28/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Partial 2/3/2020 2/3/2020 02/03/2020
Misc
Informational
02/03/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Passed 2/7/2020 02/18/2020
Misc
Resolved
02/18/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 2/4/2020 02/18/2020
Misc
Resolved
02/18/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Failed 4/21/2020 4/21/2020 04/21/2020
Misc
Corrective Action Required
04/21/2020
- Obtain irrigation system permit and submit backflow certification - GFCI protection required at front porch receptacle - Two locking devices required for sliding back door - GFCI protection required at kitchen island receptacle - Complete range electrical receptacle - GFCI protection required at receptacle in cabinet by pantry, within 6’ of sink - Outlet cover plate required at fridge receptacle - Grocery small door into pantry from garage, install door lock and make self closing - GFCI receptacle in garage testing bad for open ground - 3 car garage requires 3 electrical receptacles - Install trim around ceiling access in garage to provide proper seal - Garage door to mud room must be self closing - Install bath exhaust fan, bath next to mud room - Lights at stairs to basement and basement lights must be operational - Loose duct support at joists in basement - Secure main water line for support to foundation - Complete electrical panel and mark all breaker locations properly - Remove all smoke CO detector covers, make operational and interconnect all smoke and CO detectors - Install electrical to water heater and make operational - GFCI electrical receptacle required in basement - 2nd floor N bedroom bath, install bath exhaust fan - 2nd floor N bedroom bath, unable to test receptacle for GFCI protection, no current to receptacle - 2nd floor S bed bath, install bath exhaust fan - 2nd floor - Install all electrical receptacle covers and switch plate covers at all locations - Make 2nd floor attic access door sized to properly seal against trim - Install vanity light fixtures in master bath - Install bath exhaust fan in master bath at both locations - Install exterior light fixtures outside of garage - Install AC compressor and equipment - Unable to test GFCI receptacle function at back porch, no current to test - Complete grade and SOD - Place splashblocks at all downspout and sump pump discharge locations for minimum distance from foundation 36” - PERMIT PULLED AFTER APRIL 1 2019 (PERMIT DATED JUNE 25 2019) SHALL MEET CODE (NEC 2017) REQUIREMENTS - AFCI REQUIRED PER NEC 210.12 - TAMPER RESISTANT RECEPTACLES PER 406.12 - DISHWASHER AND LAUNDRY OUTLETS GFCI PROTECTION PER 210.8(A) AND (D). - 20 AMP GARAGE CIRCUIT AND OUTLETS SHALL BE REQUIRED PER NEC 210.11 (C)(4) AND 210.52 (G)(1)
Occupancy Inspection - Codes Residential Failed 4/24/2020 4/24/2020 04/24/2020
Misc
Corrective Action Required
04/21/2020
- Obtain irrigation system permit and submit backflow certification - 3 car garage requires 3 electrical receptacles - E3901.9 - not less than one receptacle outlet, in addition to any provided for specific equipment shall be installed in each vehicle bay - Complete electrical panel and mark all breaker locations properly - not done - Interconnect all smoke and CO detectors, CO detector required in 2nd floor hallway - sump pump discharge location minimum distance from foundation 36” - Seal around all exterior light fixtures - Seal all exterior penetrations in siding - PERMIT PULLED AFTER APRIL 1 2019 (PERMIT JUNE 25 2019) SHALL MEET CODE (NEC 2017) REQUIREMENTS - AFCI REQUIRED PER NEC 210.12 - 20 AMP GARAGE CIRCUIT AND OUTLETS SHALL BE REQUIRED PER NEC 210.11 (C)(4) AND 210.52 (G)(1)
Occupancy Inspection - Codes Residential Temporary C of O 4/28/2020 4/28/2020 04/28/2020
Misc
Corrective Action Required
04/24/2020
- Obtain irrigation system permit and submit backflow certification - sump pump discharge location minimum distance from foundation 36” - Complete final grade and sod
Plot Plan Inspection Passed 6/12/2020 06/12/2020
Occupancy Inspection - Codes Residential Failed 6/12/2020 06/12/2020
Misc
Corrective Action Required
04/28/2020
- Obtain irrigation system permit and submit backflow certification - TCO EXPIRED 5/12/2020
Occupancy Inspection - Codes Residential Failed 05/18/2021
Misc
Corrective Action Required
06/12/2020
- Obtain irrigation system permit and submit backflow certification - TCO EXPIRED 5/12/2020
Misc
Corrective Action Required
05/18/2021
The temporary certificate of occupancy has expired at this address. If remaining correction items are complete please schedule an occupancy inspection. If remaining correction items are not complete a permit extension request must be submitted in writing with the expected date of completion.
Occupancy Inspection - Codes Residential Failed 5/20/2021 5/20/2021 05/20/2021
Misc
Corrective Action Required
05/18/2021
- Obtain irrigation system permit and submit backflow certification - TCO EXPIRED 5/12/2020
Misc
Corrective Action Required
05/18/2021
The temporary certificate of occupancy has expired at this address. If remaining correction items are complete please schedule an occupancy inspection. If remaining correction items are not complete a permit extension request must be submitted in writing with the expected date of completion.
Documents & Images
Date Uploaded File Type Document Name
06/25/2019 Receipt Receipt for transaction: 2019-004106
06/25/2019 Letter Codes Building Permit
06/26/2019 Plot Plan DOC062519-06252019160500
07/15/2019 Letter INSPECTION SUMMARY
07/15/2019 Letter INSPECTION SUMMARY
08/13/2019 Letter INSPECTION SUMMARY
08/14/2019 Letter INSPECTION SUMMARY
08/15/2019 Letter INSPECTION SUMMARY
08/27/2019 Letter INSPECTION SUMMARY
12/03/2019 Letter INSPECTION SUMMARY
12/03/2019 Letter INSPECTION SUMMARY
12/03/2019 Letter INSPECTION SUMMARY
12/03/2019 Letter INSPECTION SUMMARY
12/04/2019 Letter INSPECTION SUMMARY
12/04/2019 Letter INSPECTION SUMMARY
12/04/2019 Letter INSPECTION SUMMARY
12/04/2019 Letter INSPECTION SUMMARY
12/04/2019 Letter INSPECTION SUMMARY
12/04/2019 Letter INSPECTION SUMMARY
12/05/2019 Letter INSPECTION SUMMARY
12/05/2019 Letter INSPECTION SUMMARY
12/05/2019 Letter INSPECTION SUMMARY
12/05/2019 Letter INSPECTION SUMMARY
12/10/2019 Letter INSPECTION SUMMARY
12/11/2019 Letter INSPECTION SUMMARY
01/28/2020 Letter INSPECTION SUMMARY
02/03/2020 Letter INSPECTION SUMMARY
02/18/2020 Letter INSPECTION SUMMARY
02/18/2020 Letter INSPECTION SUMMARY
04/21/2020 Letter INSPECTION SUMMARY
04/24/2020 Letter INSPECTION SUMMARY
04/28/2020 Letter Codes Temporary Certificate of Occupancy
06/11/2020 LOT 666 ASBUILT
06/12/2020 Letter INSPECTION SUMMARY
06/12/2020 Letter INSPECTION SUMMARY
10/30/2020 Letter Codes 140 Day Letter
05/18/2021 Letter INSPECTION SUMMARY
05/18/2021 Letter INSPECTION SUMMARY
05/20/2021 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home