Permit Application Status

PRRES20191352


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20191352
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK
05/24/2019
06/11/2019
08/13/2020
Locations
Contacts
SCOTT PRIER HOMES LLC, Address:404 SE HACKAMORE DR, Phone:(816) 509-8302  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
HOLSEY ELECTRIC, Inc, Address:1637 NW 100 RD, Phone:(816) 697-2112  
SUBURBAN PLUMBING, Address:20124 HOPS CREEK DR, Phone:(816) 985-0259  
SPRIER76@YAHOO.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 05/29/2019 06/11/2019
Kim Brennan
Miscellaneous Correction
Corrective Action Required
05/24/2019

The plans reference the 2012 Code book and it should reference the 2018 code book
Miscellaneous Correction
Corrective Action Required
05/24/2019

It appears that these drawings is a copy or a "same As" plan as it already the city's approval stamp on it and the date from the engineer is over a year old. We do not accept same as plans anymore so please update these drawings to reflect that.
Plot Plan Review Approved 05/29/2019 05/30/2019
Steve Conrick
Basement elevation
Corrective Action Required
05/30/2019

The Basement floor elevation and basement type (e.g. full/standard, daylight, walk-out, etc.) *MDP calls for a standard basement for this lot
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,294.86 $1,294.86 Paid 06/11/2019
Right of Way Permit Fee $80.00 $80.00 Paid 06/11/2019
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 06/11/2019
8331507-Sewer Connection Fee $600.00 $600.00 Paid 06/11/2019
Water Tap Fee $3,409.00 $3,409.00 Paid 06/11/2019
Water Meter Fee $408.37 $408.37 Paid 06/11/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 6/28/2019 (1:00) 6/28/2019 at 2:00 PM 06/28/2019
Sewer Service Inspection - R Passed 7/23/2019 (11:00) 7/23/2019 at 11:15 AM 07/23/2019
Water Service Inspection - R Partial 7/23/2019 (11:00) 7/23/2019 07/23/2019
Erosion Control Inspection Residential Failed 7/24/2019 07/24/2019
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
07/24/2019
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Underslab Plumbing Inspection - Residential Passed 7/24/2019 7/24/2019 at 9:35 AM 07/24/2019
Water Service Inspection - R Passed 7/26/2019 at 4:00 PM 07/26/2019
Piers/Caissons Inspection - Residential Passed 8/14/2019 (9:45) 8/14/2019 at 10:35 AM 08/14/2019
Electrical Service Inspection Failed 9/11/2019 9/11/2019 09/11/2019
Misc
Corrective Action Required
09/11/2019
-Cannot open the service panel cover
Gas Service Inspection - Residential Failed 9/11/2019 9/11/2019 09/11/2019
Misc
Corrective Action Required
09/11/2019
-No pressure
All Rough Inspection - Residential Failed 9/11/2019 9/11/2019 at 12:55 PM 09/11/2019
Misc
Corrective Action Required
09/11/2019
FRAMING: -Anchor sill plates within 12” of breaks, no less than 3.5” from breaks -Fur out wall at garage/mud return air space for R-13 insulation -Fb garage duct/b vent chase from joist space ; Fb garage wall from soffit -Solid-block front dining cantilevered ceiling joists above bearing wall -Nail corner studs per code (16d @12" oc or equivalent nailing) -Support hip rafters above front bedroom and master closet -Install 3 stud support for I beam at front dining/living rm angled wall -Provide solid support under I beam point load within return air space (RA near main duct) PLUMBING: -Protect plumbing at rear living rm wall -Strap top plates where bored more than 50% at rear living rm wall, rear bathroom wall ELECTRICAL: -Protect wiring running across bottom of joists **OK TO INSULATE
Erosion Control Inspection Residential Failed 9/11/2019 09/11/2019
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
07/24/2019
DEFICIENT EROSION CONTROL INSTALLATION. MUST RESTORE EROSION CONTROL ALONG STREET AND PROPERTY LINE. BOTTOM OF THE SILT FENCE SHALL BE BURIED MIN 6" DOWN NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Erosion Control Inspection Residential Failed 9/16/2019 09/16/2019
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
09/11/2019
DEFICIENT EROSION CONTROL INSTALLATION. -BOTTOM OF THE SILT FENCE SHALL BE BURIED MIN 6" DOWN. LOOK AT THE FRONT CORNER. MUD JUST FLOWING UNDERNEATH THE SILT FENCE -RESTORE STAKING THE SILT FENCE LAST WARNING: NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. STOP WORK ORDER WILL BE ISSUED IF EROSION CONTROL IS NOT IN COMPLIANCE
Electrical Service Inspection Passed 9/16/2019 9/16/2019 09/16/2019
Misc
Resolved
09/16/2019
-Cannot open the service panel cover
Gas Service Inspection - Residential Passed 9/16/2019 9/16/2019 09/16/2019
Misc
Resolved
09/16/2019
-No pressure
All Rough Inspection - Residential Failed 9/16/2019 9/16/2019 at 8:35 AM 09/16/2019
Misc
Corrective Action Required
09/11/2019
FRAMING: -Nail corner studs per code (16d @12" oc or equivalent nailing) -Support hip rafters above front bedroom and master closet PLUMBING: -Strap top plates where bored more than 50% at rear bathroom wall **THE UFER GROUNDING CONNECTION AT THE STAIR WALL MUST BE ACCESSIBLE AT FINAL INSPECTION
All Rough Inspection - Residential Failed 9/17/2019 at 8:50 AM 09/17/2019
Misc
Corrective Action Required
09/16/2019
-Support hip rafters above front bedroom and master closet
Erosion Control Inspection Residential Passed 9/18/2019 09/18/2019
Informational
09/18/2019
EROSION CONTROL IS IN COMPLIANCE. MAINTAIN EROSION CONTROL UNTIL SODDING
All Rough Inspection - Residential Passed 9/18/2019 at 9:50 AM 09/18/2019
Misc
Resolved
09/18/2019
-Support hip rafters above front bedroom and master closet
Driveway Inspection Partial 11/6/2019 11/6/2019 11/06/2019
Misc
Informational
11/06/2019
Driveway - forms and materials passed pre-inspection.
Driveway Inspection Passed 11/14/2019
Misc
Informational
11/06/2019
Driveway - forms and materials passed pre-inspection.
Misc
Informational
11/14/2019
Driveway- Passed final inspection.
Occupancy Inspection - Codes Residential Failed 1/30/2020 1/30/2020 at 9:05 AM 01/30/2020
Misc
Corrective Action Required
07/15/2019
-PROVIDE LANDSCAPING COMPLYING WITH THE REQUIREMENT PER CITY ORDINANCE ALONG THE REAR OF LOT
Misc
Corrective Action Required
09/17/2019
-Water meter well needs set at grade, an extension is needed.
Miscellaneous Correction
Corrective Action Required
01/30/2020
-Final grade, sod, roof drainage and downspout extensions, sump pump discharge -Make sure the sewer tracer wire and port is available at grade level -Lawn irrigation permit -Seal exterior wall penetrations, lights, above meter and AC disconnect, etc -Install box extensions for all boxes recessed more than 1/4” behind kitchen countertop backsplash -Dish washer receptacle shall be gfci-protected -15-20 amp receptacles in laundry area shall be gfci-protected -Provide afci protection for all 15-20 amp circuits supplying outlets in kitchen, dining, closet, hallway, laundry, etc. NEC 210.12 -Locate ufer grounding connection -Sewer clean out must be accessible per IRC P3005.2.10. Install clean out plug
Occupancy Inspection - Codes Residential Temporary C of O 2/3/2020 2/3/2020 at 8:35 AM 02/03/2020
Misc
Corrective Action Required
01/30/2020
-PROVIDE LANDSCAPING COMPLYING WITH THE REQUIREMENT PER CITY ORDINANCE ALONG THE REAR OF LOT
Misc
Corrective Action Required
01/30/2020
-Water meter well needs set at grade, an extension is needed.
Miscellaneous Correction
Corrective Action Required
01/30/2020
-Final grade, sod, roof drainage and downspout extensions, sump pump discharge -Make sure the sewer tracer wire and port is available at grade level -Lawn irrigation permit -Seal exterior wall penetrations, lights, above meter and AC disconnect, etc -Dish washer receptacle shall be gfci-protected **Install a dual purpose breaker that provides both afci and gfci protection -Provide afci protection for circuit supplying outlet in laundry. NEC 210.12
Occupancy Inspection - Codes Residential Failed 7/30/2020 7/30/2020 at 8:45 AM 07/30/2020
Misc
Resolved
07/30/2020
-PROVIDE LANDSCAPING COMPLYING WITH THE REQUIREMENT PER CITY ORDINANCE ALONG THE REAR OF LOT
Misc
Corrective Action Required
01/30/2020
-Water meter well needs set at grade, an extension is needed. **concrete blocks are used to elevate the top ring&lid to grade level, instead of a proper extension.
Miscellaneous Correction
Corrective Action Required
01/30/2020
-Dish washer receptacle shall be gfci-protected **Install a dual purpose breaker that provides both afci and gfci protection -Provide afci protection for circuit supplying outlet in laundry. NEC 210.12
Documents & Images
Date Uploaded File Type Document Name
05/24/2019 Letter Codes Residential Plan Review
06/11/2019 Receipt Receipt for transaction: 2019-003562
06/11/2019 Letter Codes Building Permit
06/12/2019 Plot Plan DOC061219-06122019082621
06/28/2019 Letter INSPECTION SUMMARY
07/23/2019 Letter INSPECTION SUMMARY
07/23/2019 Letter INSPECTION SUMMARY
07/24/2019 Letter INSPECTION SUMMARY
07/26/2019 Letter INSPECTION SUMMARY
08/14/2019 Letter INSPECTION SUMMARY
09/11/2019 Letter INSPECTION SUMMARY
09/11/2019 Letter INSPECTION SUMMARY
09/11/2019 Letter INSPECTION SUMMARY
09/11/2019 Letter INSPECTION SUMMARY
09/16/2019 Letter INSPECTION SUMMARY
09/16/2019 Letter INSPECTION SUMMARY
09/16/2019 Letter INSPECTION SUMMARY
09/16/2019 Letter INSPECTION SUMMARY
09/17/2019 Letter INSPECTION SUMMARY
09/18/2019 Letter INSPECTION SUMMARY
11/14/2019 Letter INSPECTION SUMMARY
11/14/2019 Letter INSPECTION SUMMARY
01/30/2020 Letter INSPECTION SUMMARY
01/30/2020 Letter INSPECTION SUMMARY
01/30/2020 Letter INSPECTION SUMMARY
02/03/2020 Letter Codes Temporary Certificate of Occupancy
07/30/2020 Letter INSPECTION SUMMARY
08/13/2020 Letter Codes Final Certificate of Occupancy
08/13/2020 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home