Summary
PRRES20191226
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK OLD SQUARE FOOTAGE FOR BASEMENT 962 FINISHED AND 806 UNFINISHED NEW SQUARE FOOTAGE 757 UNFINISHED AND 789 FINISHED BASEMENT
05/14/2019
05/23/2019
10/19/2020
Locations
Contacts
NICK ZVACEK CONSTRUCTION LLC, Address:1009 INDUSTRIAL DR, Phone:(816) 213-7204  
COMFORT SYSTEMS HTG/CLG, Address:128 W Markey Rd, Phone:(816) 322-1013  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
NZVACEK@GMAIL.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 05/16/2019 05/22/2019
Kim Brennan
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
05/14/2019

Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304) No square footage shown for unfinished basement, covered deck or garage.
Misc
Corrective Action Required
05/14/2019

Application shows 48 square feet for the covered deck but the plans show that it is a 12X14 deck. Please clarify.
Plot Plan Review Approved 05/16/2019 05/16/2019
Steve Conrick
As-graded plot plan
Corrective Action Required
05/14/2019

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy. *Add note in a bubble "AS-GRADED PLOT PLAN IS REQUIRED PRIOR TO SODDING."
Drainage swales
Corrective Action Required
05/14/2019

Drainage swales (where required); show spot elevations within the swale as required to conform to the approved master drainage plan (if applicable), must be provideD *Call out swale running along rear property line
Lot elevations
Corrective Action Required
05/14/2019

Existing and finish elevations at all property corners must be provided on the plot plan. *Check the elevation at the NW corner
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,024.11 $1,024.11 Paid 05/23/2019
Right of Way Permit Fee $80.00 $80.00 Paid 05/23/2019
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 05/23/2019
8331507-Sewer Connection Fee $390.00 $390.00 Paid 05/23/2019
Water Tap Fee $3,409.00 $3,409.00 Paid 05/23/2019
Water Meter Fee $408.37 $408.37 Paid 05/23/2019
Not Ready Inspection Fee $50.00 $50.00 Paid 04/01/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Not Ready 5/23/2019 (1:15) 5/23/2019 at 1:45 PM 05/23/2019
Misc
Corrective Action Required
05/23/2019
DENIED DUE TO LACK OF EROSION CONTROL
Erosion Control Inspection Residential Failed 5/23/2019 05/23/2019
DCM5 ESC INSP DENIED
Corrective Action Required
05/23/2019
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
Erosion Control Inspection Residential Passed 5/23/2019 05/23/2019
DCM5 ESC INSP DENIED
Resolved
05/23/2019
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
Footing Inspection - Residential Passed 5/23/2019 at 4:10 PM 05/23/2019
Misc
Resolved
05/23/2019
DENIED DUE TO LACK OF EROSION CONTROL
Underslab Plumbing Inspection - Residential Failed 6/10/2019 at 10:15 AM 06/10/2019
Misc
Corrective Action Required
06/10/2019
-VENT BASEMENT SHOWER AND WATER CLOSET PER CODE
Underslab Plumbing Inspection - Residential Passed 6/12/2019 6/11/2019 at 1:55 PM 06/11/2019
Misc
Resolved
06/11/2019
-VENT BASEMENT SHOWER AND WATER CLOSET PER CODE
Sewer Service Inspection - R Passed 7/18/2019 (1:00) 7/18/2019 at 1:35 PM 07/18/2019
Water Service Inspection - R Partial 7/18/2019 07/18/2019
Water Service Inspection - R Passed 7/19/2019 (11:00) 7/19/2019 at 11:30 AM 07/19/2019
Piers/Caissons Inspection - Residential Passed 8/12/2019 8/12/2019 at 1:30 PM 08/12/2019
Driveway Inspection Partial 8/14/2019 8/14/2019 08/14/2019
Misc
Informational
08/14/2019
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
All Rough Inspection - Residential Failed 8/26/2019 8/26/2019 at 8:00 AM 08/26/2019
Misc
Corrective Action Required
08/26/2019
FRAMING: -Fb great room and foyer wall from roof -Add blockings and fully nail ceiling beam hangers above great room -Nail together double ceiling beams, including the lvl beam -Complete framing at mud/stair/kitchen -Extend strap to top plate; strap the inner side of the north garage portal brace wall -Over notched ceiling joist above garage Check permit -Over bored laundry wall stud -Fb bedroom wall from roof -Bedroom gable wall studs are required to be continuous from floor to ceiling -Support hip rafter best mid-span to bearing wall -Nail corner studs with 16d @12” oc or equivalent nailing -Fb wall space in basement vertically at max ten ft interval -Insulate first, then solidblock all cantilevered joists at rear basement wall -Install hangers upside down for cantilevered joist to support deck joists -Nail rear basement exterior wall siding to sill plates at 6” oc -Lag deck ledger board through spacers -Update plan to include structural changes above main floor and basement layout PLUMBING: -Strap top plates where bored more than 50% -Protect plumbing at living rm/master bath wall -Protect plumbing at basement bathroom and bedroom closet -Vent master bathroom tub and shower traps per code -Support plumbing at maximum four ft spacing -Slope laundry drain min 1/4” per ft ELECTRICAL: -Protect wiring running across top of joists where within 6 ft of attic access **OK TO INSULATE
Electrical Service Inspection Passed 8/26/2019 8/26/2019 08/26/2019
Gas Service Inspection - Residential Passed 8/26/2019 8/26/2019 08/26/2019
All Rough Inspection - Residential Failed 9/3/2019 9/3/2019 at 9:00 AM 09/03/2019
Misc
Corrective Action Required
08/26/2019
FRAMING: -Fb great room and foyer wall from roof -Fb bedroom wall from roof -Fb wall space in basement vertically at max ten ft interval -Nail rear basement exterior wall siding to sill plates at 6” oc -Lag deck ledger board through spacers **OK TO INSULATE
All Rough Inspection - Residential Passed 9/5/2019 9/5/2019 at 9:05 AM 09/05/2019
Misc
Resolved
09/05/2019
FRAMING: -Fb great room and foyer wall from roof -Fb bedroom wall from roof -Fb wall space in basement vertically at max ten ft interval -Nail rear basement exterior wall siding to sill plates at 6” oc -Lag deck ledger board through spacers **OK TO INSULATE
Driveway Inspection Passed 8/21/2019 10/11/2019
Misc
Informational
08/14/2019
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Misc
Informational
10/11/2019
Driveway - passed final inspection.
Erosion Control Inspection Residential Failed 10/22/2019 10/22/2019
DCM5 ESC INSP DENIED
Corrective Action Required
10/22/2019
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. Swale at rear yard needs to be Corrected and silt fence established. Contact Steve Robbins or Mark Harding
Occupancy Inspection - Codes Residential Not Ready 3/30/2020 3/31/2020 at 8:25 AM 03/31/2020
Corrective Action Required
03/30/2020
**5/23-NOT READY FEE ASSESSED FOR NO EROSION CONTROL AT FOOTING INSPECTION **3/31-NOT READY FEE ASSESSED FOR NO ACCESS TO THE HOUSE FOR INSPECTION. I ASK THAT THE BUILDER LEAVE THE LOCKBOX CODE OR LEAVE THE DOOR UNLOCK
Occupancy Inspection - Codes Residential Failed 4/1/2020 4/1/2020 at 8:35 AM 04/01/2020
Misc
Corrective Action Required
04/01/2020
**5/23-NOT READY FEE ASSESSED FOR NO EROSION CONTROL AT FOOTING INSPECTION -As-graded plot plan is required prior to sodding -Final grade, sod, downspout extensions -Install tamper proof caps at the AC valves -Missing middle deck pier; lag screws must go through the spacers; install support device of outer joist to ledger board -Provide 5/8” gypsum under garage box out -Pendant light located within bath tub zone -Install box extension for the floor receptacle box -Provide breaker lock for hood -Install box extensions for switch & receptacle boxes recessed more than 1/4” behind kitchen countertop backsplash -Provide gfci protection for dish washer and laundry outlets per NEC 210.8(A) and (D) -Provide AFCI protection for all outlets required per NEC 210.12 -Cover or remove insulation paper facing -Furnace condensate drain must be able to be cleaned out
Occupancy Inspection - Codes Residential Failed 4/2/2020 4/2/2020 at 7:55 AM 04/02/2020
Misc
Corrective Action Required
04/01/2020
**5/23-NOT READY FEE ASSESSED FOR NO EROSION CONTROL AT FOOTING INSPECTION -As-graded plot plan is required prior to sodding -Final grade, sod, downspout extensions -Install tamper proof caps at the AC valves -Missing middle deck pier; lag screws must go through the spacers; install support device of outer joist to ledger board -Cover or remove insulation paper facing -Furnace condensate drain must be able to be cleaned out
Piers/Caissons Inspection - Residential Failed 4/2/2020 4/2/2020 04/02/2020
Misc
Corrective Action Required
04/02/2020
-PIER MUST BE 36" DEEP , 16" DIA
Occupancy Inspection - Codes Residential Temporary C of O 4/3/2020 4/2/2020 at 2:55 PM 04/02/2020
Misc
Corrective Action Required
04/02/2020
-As-graded plot plan is required prior to sodding -Final grade, sod, downspout extensions -Missing middle deck pier; lag screws must go through the spacers; install support device of outer joist to ledger board
Occupancy Inspection - Codes Residential Failed 5/19/2020 5/19/2020 05/19/2020
Misc
Corrective Action Required
04/02/2020
-As-graded plot plan is required prior to sodding -Final grade, sod, downspout extensions -Missing middle deck pier; lag screws must go through the spacers; install support device of outer joist to ledger board **Deck middle pier inspected-OK to pour after water is pumped out
Piers/Caissons Inspection - Residential Passed 4/17/2020 5/19/2020 05/19/2020
Misc
Informational
05/19/2020
OK to pour after water is pumped out
Occupancy Inspection - Codes Residential Full C of O 10/19/2020 10/19/2020 10/19/2020
Misc
Resolved
10/19/2020
-As-graded plot plan is required prior to sodding -Final grade, sod, downspout extensions -Lag screws must go through the spacers; install support device of outer joist to ledger board
Erosion Control Inspection Residential Passed 10/19/2020
DCM5 ESC INSP DENIED
Resolved
10/19/2020
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. Swale at rear yard needs to be Corrected and silt fence established. Contact Steve Robbins or Mark Harding
Plot Plan Inspection Passed 4/1/2020 (8:00) 10/20/2020 10/19/2020
Documents & Images
Date Uploaded File Type Document Name
05/14/2019 Letter Codes Residential Plan Review
05/14/2019 Letter Codes Residential Plan Review
05/23/2019 Receipt Receipt for transaction: 2019-002723
05/23/2019 Letter Codes Building Permit
05/23/2019 Plot Plan DOC052319-002
05/23/2019 Letter INSPECTION SUMMARY
05/23/2019 Letter INSPECTION SUMMARY
05/23/2019 Letter INSPECTION SUMMARY
05/23/2019 Letter INSPECTION SUMMARY
06/10/2019 Letter INSPECTION SUMMARY
06/11/2019 Letter INSPECTION SUMMARY
07/18/2019 Letter INSPECTION SUMMARY
07/18/2019 Letter INSPECTION SUMMARY
07/19/2019 Letter INSPECTION SUMMARY
08/12/2019 Letter INSPECTION SUMMARY
08/14/2019 Letter INSPECTION SUMMARY
08/26/2019 Letter INSPECTION SUMMARY
08/26/2019 Letter INSPECTION SUMMARY
08/26/2019 Letter INSPECTION SUMMARY
08/28/2019 Letter DS Building Permit
09/03/2019 Letter INSPECTION SUMMARY
09/05/2019 Letter INSPECTION SUMMARY
10/22/2019 Letter INSPECTION SUMMARY
03/31/2020 Letter INSPECTION SUMMARY
04/01/2020 Letter INSPECTION SUMMARY
04/01/2020 Receipt Receipt for transaction: 2020-001366
04/02/2020 Letter INSPECTION SUMMARY
04/02/2020 Letter INSPECTION SUMMARY
04/02/2020 Letter Codes Temporary Certificate of Occupancy
05/19/2020 Letter INSPECTION SUMMARY
05/19/2020 Letter INSPECTION SUMMARY
10/09/2020 Letter Codes 10 Day Letter
10/19/2020 Letter Codes Final Certificate of Occupancy
10/19/2020 Letter Field Certificate of Occupancy
10/19/2020 Letter INSPECTION SUMMARY
10/19/2020 Letter INSPECTION SUMMARY
10/19/2020 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home