Summary
PRRES20190832
Building Permit - Residential
Certificate of Occupancy
CLAYTON PROPERTIES GROUP INC
NEW SINGLE FAMILY
NEW HOUSE, FINISHED/UNFINISHED BASEMENT AND UNCOVERED DECK
04/08/2019
04/15/2019
04/15/2020
Locations
Contacts
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
VALERIE@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
KIMBEL MECHANICAL SYSTEMS, INC, Address:1936 N SHILOH DR, Phone:(479) 756-1099  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 04/10/2019 04/12/2019
Steve Conrick
As-graded plot plan
Corrective Action Required
04/10/2019

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy. *Add note "AS-GRADED PLOT PLAN IS REQUIRED PRIOR TO SODDING."
City infrustructure
Corrective Action Required
04/10/2019

Show all manholes, water valve boxes, fire hydrants, and stormwater structures. *Missing storm MH near NW corner.
Residential Plan Review Approved 04/10/2019 04/10/2019
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,278.52 $1,278.52 Paid 04/15/2019
8331507-Sewer Connection Fee $510.00 $510.00 Paid 04/15/2019
8331401-Water Tap Fee $3,409.00 $3,409.00 Paid 04/15/2019
8350015-Water Meter Fee $408.37 $408.37 Paid 04/15/2019
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 04/15/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 5/16/2019 (8:30) 5/16/2019 at 9:00 AM 05/16/2019
Sewer Service Inspection - R Passed 6/4/2019 (9:15) 6/4/2019 at 9:35 AM 06/04/2019
Water Service Inspection - R Partial 6/4/2019 at 9:51 AM 06/04/2019
Water Service Inspection - R Passed 6/7/2019 6/7/2019 at 11:00 AM 06/07/2019
Piers/Caissons Inspection - Residential Passed 7/18/2019 7/18/2019 07/18/2019
Gas Piping Inspection - Residential Failed 8/6/2019 8/6/2019 at 9:55 AM 08/06/2019
Misc
Corrective Action Required
08/06/2019
30psi max gauge for gas piping.
Gas Service Inspection - Residential Failed 8/6/2019 8/6/2019 08/06/2019
Electrical Service Inspection Failed 8/6/2019 8/6/2019 at 10:10 AM 08/06/2019
Misc
Corrective Action Required
08/06/2019
secure wiring within 12" of panel
All Rough Inspection - Residential Failed 8/6/2019 8/6/2019 at 10:21 AM 08/06/2019
Misc
Corrective Action Required
08/06/2019
Fire block above great room entry from mudroom above doorway and on both sides. Fir out beam of in basement. Fire block dead space at southeast firred out wall in basement. Fire block vertically at northeast corner of basement in closet. Secure wiring within 12” of panel. OK TO INSULATE
All Rough Inspection - Residential Passed 8/13/2019 8/13/2019 08/13/2019
Misc
Resolved
08/13/2019
Electrical Service Inspection Passed 8/13/2019 8/13/2019 08/13/2019
Misc
Resolved
08/13/2019
Gas Service Inspection - Residential Passed 8/13/2019 8/13/2019 08/13/2019
Gas Piping Inspection - Residential Passed 8/13/2019 08/14/2019
Misc
Resolved
08/14/2019
Driveway Inspection Partial 8/15/2019 8/15/2019 08/15/2019
Misc
Informational
08/15/2019
AUGUST 15, 2019 PRE POUR INSPECTION All forms meet Lees Summit and ADA spec. There is gravel installed and it is compacted. Contractor will call back for sidewalk pour.
Driveway Inspection Passed 08/21/2019
Misc
Informational
08/15/2019
AUGUST 15, 2019 PRE POUR INSPECTION All forms meet Lees Summit and ADA spec. There is gravel installed and it is compacted. Contractor will call back for sidewalk pour.
Misc
Informational
08/21/2019
AUGUST 21, 2019 POST POUR INSPECTION PASS Driveway approach meet Lees Summit and ADA spec.
Sidewalk Inspection Partial 11/4/2019 (Ready Now) 11/11/2019 11/04/2019
Misc
Informational
11/04/2019
NOVEMBER 4, 2019 PRE POUR INSPECTION PASS At time of inspection, all forms were within ADA and Lees Summit spec. There was the appropriate amount of gravel, and it was compacted.
Occupancy Inspection - Codes Residential Failed 11/8/2019 11/8/2019 11/08/2019
Misc
Corrective Action Required
11/08/2019
- Erosion control needed at front of lot - guard rails needed for front porch - garage door needs to be self closing and latching - exhaust fan in spare bathroom outside of master bedroom not working - install faceplates throughout house - GFCI outlet outside of walkout basement door not working correctly - seal all outside light fixtures, penetrations, etc - sod, splash blocks, final grade needed - fix downed erosion control at rear of property - sump pump discharge needs to be 36” from foundation wall
Misc
Corrective Action Required
11/08/2019
- Erosion control needed at front of lot - guard rails needed for front porch - garage door needs to be self closing and latching - exhaust fan in spare bathroom outside of master bedroom not working - install faceplates throughout house - GFCI outlet outside of walkout basement door not working correctly - seal all outside light fixtures, penetrations, etc - sod, splash blocks, final grade needed - fix downed erosion control at rear of property - sump pump discharge needs to be 36” from foundation wall - as graded plot plan needs to be submitted to front counter staff
Occupancy Inspection - Codes Residential Temporary C of O 11/13/2019 11/13/2019 11/13/2019
Misc
Resolved
11/13/2019
Misc
Corrective Action Required
11/08/2019
-GFCI outlet outside of walkout basement door not working correctly - seal all outside light fixtures, penetrations, etc - sod, splash blocks, final grade needed - sump pump discharge needs to be 36” from foundation wall - as graded plot plan needs to be submitted to front counter staff
Occupancy Inspection - Codes Residential Temporary C of O 11/26/2019 11/26/2019 11/26/2019
Misc
Resolved
11/26/2019
Misc
Corrective Action Required
11/08/2019
- seal all outside light fixtures - as graded plot plan needs to be submitted to front counter staff
Occupancy Inspection - Codes Residential Temporary C of O 12/13/2019 12/13/2019
Misc
Corrective Action Required
12/13/2019
-As graded plot plan needs to be submitted and approved by front counter staff -Seal all exterior light fixtures Please complete these last items as temporary occupancy has expired.
Occupancy Inspection - Codes Residential Temporary C of O 12/13/2019 12/13/2019
Misc
Corrective Action Required
12/13/2019
- as graded plot plan needs to be submitted and approved by front counter staff - seal all exterior light fixtures
Plot Plan Inspection Passed 4/3/2020 04/03/2020
Occupancy Inspection - Codes Residential Failed 4/3/2020 4/3/2020 04/03/2020
Misc
Corrective Action Required
04/03/2020
- NO UNDERSLAB PLUMBING INSPECTION ON RECORD - SIDEWALK INSPECTION STILL PENDING -
Sidewalk Inspection Passed 4/3/2020 (Ready Now) 4/3/2020 04/03/2020
Misc
Informational
11/04/2019
NOVEMBER 4, 2019 PRE POUR INSPECTION PASS At time of inspection, all forms were within ADA and Lees Summit spec. There was the appropriate amount of gravel, and it was compacted.
Occupancy Inspection - Codes Residential Failed 4/6/2020 4/6/2020 04/06/2020
Misc
Corrective Action Required
04/03/2020
- NO UNDERSLAB PLUMBING INSPECTION ON RECORD -
Underslab Plumbing Inspection - Residential Passed 4/15/2020 04/15/2020
Miscellaneous Correction
Informational
04/15/2020
LETTER FROM KIMBEL MECHANICAL WORK PERFORMED BY ORRIN HACKER - - LETTER FROM DUSTIN @ SUMMIT -
Occupancy Inspection - Codes Residential Full C of O 4/15/2020 04/15/2020
Misc
Resolved
04/15/2020
- NO UNDERSLAB PLUMBING INSPECTION ON RECORD -
Documents & Images
Date Uploaded File Type Document Name
04/10/2019 Letter Codes Residential Plan Review
04/15/2019 Receipt Receipt for transaction: 2019-001432
04/15/2019 Letter Codes Building Permit
04/17/2019 Plot Plan DOC041619-04162019142043
05/16/2019 Letter INSPECTION SUMMARY
06/04/2019 Letter INSPECTION SUMMARY
06/04/2019 Letter INSPECTION SUMMARY
06/07/2019 Letter INSPECTION SUMMARY
06/13/2019 Engineer Report/Study 4409 SW Nautilus Pl_Lot 22 Creekside at Raintree Final_2019.06.12_BSlab_LSMO_Cochran Concrete
07/18/2019 Letter INSPECTION SUMMARY
08/06/2019 Letter INSPECTION SUMMARY
08/06/2019 Letter INSPECTION SUMMARY
08/06/2019 Letter INSPECTION SUMMARY
08/13/2019 Letter INSPECTION SUMMARY
08/13/2019 Letter INSPECTION SUMMARY
08/13/2019 Letter INSPECTION SUMMARY
08/14/2019 Letter INSPECTION SUMMARY
08/15/2019 Letter INSPECTION SUMMARY
08/21/2019 AUGUST 21, 2019 POST POUR Driveway
08/21/2019 Letter INSPECTION SUMMARY
11/04/2019 NOVEMBER 4, 2019 Pre Pour Sidewalk inspection
11/04/2019 Letter INSPECTION SUMMARY
11/08/2019 Letter INSPECTION SUMMARY
11/13/2019 Letter Codes Temporary Certificate of Occupancy
11/26/2019 Letter Codes Temporary Certificate of Occupancy
12/13/2019 Letter Codes Temporary Certificate of Occupancy
12/13/2019 Letter Codes Temporary Certificate of Occupancy
12/13/2019 Letter Codes Temporary Certificate of Occupancy
04/02/2020 Plot Plan RT22 As-Built
04/03/2020 Letter INSPECTION SUMMARY
04/03/2020 Letter INSPECTION SUMMARY
04/03/2020 Letter INSPECTION SUMMARY
04/06/2020 Letter INSPECTION SUMMARY
04/10/2020 Letter Plumbing Letter
04/15/2020 Letter Summit Plumbing Letter Signed
04/15/2020 Letter Codes Final Certificate of Occupancy
04/15/2020 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home