Summary
PRRES20181829
Building Permit - Residential
Certificate of Occupancy
NICK ZVACEK CONSTRUCTION LLC
NEW SINGLE FAMILY
NEW HOUSE FINISHED AND UNFINISHED BASEMENT COVERED DECK
06/14/2018
07/19/2018
10/19/2020
Locations
Contacts
NICK ZVACEK CONSTRUCTION LLC, Address:1009 INDUSTRIAL DR  
NICK ZVACEK CONSTRUCTION LLC, Address:1009 INDUSTRIAL DR, Phone:(816) 213-7204  
COMFORT SYSTEMS HTG/CLG, Address:128 W Markey Rd, Phone:(816) 322-1013  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 06/18/2018 07/10/2018
Brandon Kalwei
06 Designate use of each room or space
Corrective Action Required
06/15/2018

Designate use of each room or space including but not limited to; basement storage, garages, and attic areas intended for storage space. bathrooms on 1st and 2nd floor not labeled
28 Identify location, size, and material of all beams, girders and vertical
Corrective Action Required
06/15/2018

Identify location, size, and material of all beams, girders and vertical supports. cannot follow load path from masterbath and bedroom #2 bathroom down to first floor
Plot Plan Review Approved 06/18/2018 06/19/2018
Steve Conrick
Basement egress
Corrective Action Required
06/15/2018

Basement egress location(s) and elevation of the lowest adjacent grade must be provided on the plot plan. ***Add lowest adjacent grade to egress***
As-graded plot plan
Corrective Action Required
06/15/2018

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy. ***Put "AS-GRADED PLOT PLAN IS REQUIRED PRIOR TO SODDING" into a bubble***
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,119.37 $1,119.37 Paid 07/19/2018
Right of Way Permit Fee $75.00 $75.00 Paid 07/19/2018
8331507-Sewer Connection Fee $540.00 $540.00 Paid 07/19/2018
Water Tap Fee $3,343.00 $3,343.00 Paid 07/19/2018
Water Meter Fee $431.83 $431.83 Paid 07/19/2018
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 7/24/2018 (1:00) 7/24/2018 at 1:30 PM 07/24/2018
Misc
Corrective Action Required
07/24/2018
**SEE EROSION CONTROL
Erosion Control Inspection Residential Failed 7/24/2018 07/24/2018
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
07/24/2018
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. **PROVIDE 3/4" GRAVEL AT LOT ENTRANCE
Footing Inspection - Residential Passed 7/27/2018 7/27/2018 at 8:35 AM 07/27/2018
Misc
Resolved
07/27/2018
**SEE EROSION CONTROL
Erosion Control Inspection Residential Passed 7/27/2018 07/27/2018
DCM2 ESC DEFICIENT INSTALLATION
Resolved
07/27/2018
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. **PROVIDE 3/4" GRAVEL AT LOT ENTRANCE
Erosion Control Inspection Residential Failed 8/20/2018 08/20/2018
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
08/20/2018
DEFICIENT EROSION CONTROL INSTALLATION. EROSION CONTROL SHALL BE INSTALLED ALONG PROPERTY LINES AND RESTORED ALONG THE STREET NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Underslab Plumbing Inspection - Residential Failed 8/20/2018 8/20/2018 at 8:45 AM 08/20/2018
Misc
Corrective Action Required
08/20/2018
-VENT BASEMENT BATH TUB/SHOWER
Water Service Inspection - R Passed 8/21/2018 (10:30) 8/21/2018 at 10:35 AM 08/21/2018
Sewer Service Inspection - R Passed 8/21/2018 (10:30) 8/21/2018 08/21/2018
Erosion Control Inspection Residential Failed 8/28/2018 08/28/2018
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
08/20/2018
DEFICIENT EROSION CONTROL INSTALLATION. SHALL PROVIDE 3/4" GRAVEL AT LOT ENTRANCE. LAST WARNING. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Erosion Control Inspection Residential Failed 8/29/2018 08/29/2018
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
08/28/2018
DEFICIENT EROSION CONTROL INSTALLATION. SHALL PROVIDE 3/4" GRAVEL AT LOT ENTRANCE. LAST WARNING. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Underslab Plumbing Inspection - Residential Passed 8/29/2018 8/29/2018 at 9:15 AM 08/29/2018
Misc
Resolved
08/29/2018
-VENT BASEMENT BATH TUB/SHOWER
Erosion Control Inspection Residential Failed 10/26/2018 10/26/2018
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
08/29/2018
RE-INSTALL EROSION CONTROL ALONG THE STREET
Piers/Caissons Inspection - Residential Passed 10/26/2018 10/26/2018 at 9:55 AM 10/26/2018
Gas Service Inspection - Residential Passed 11/1/2018 11/1/2018 11/01/2018
Electrical Service Inspection Passed 11/1/2018 11/1/2018 11/01/2018
All Rough Inspection - Residential Failed 11/1/2018 11/1/2018 at 9:30 AM 11/01/2018
Misc
Corrective Action Required
11/01/2018
FRAMING: -Nail garage portal brace wall sheathing per code. Remove the trimming so I can see the whole wall nailing -Shall use 1/2” anchor bolts, not 3/8”. Anchor sill plates within 12” of breaks -Support hip rafters above garage -Provide attic access to roof space above garage -Joist notched more than 1/6 above garage steel column -Install header above garage-to-pantry door -Box out garage return air space wall for R13 insulation -Seal penetrations of return air ceiling space -Solidblock all cantilevered joists. Insulate first before solidblocking to bearing wall -Install security blocking for exterior door -Install proper hangers for beam connections above top stair landing -Front bed gable wall studs not full height from floor to ceiling -Provide full bearing for ridge beam at front bed gable wall -Nail ceiling beam hanger above rear middle bedroom -Fb basement wall vertically at ten ft interval or less -Support I beam to green plate; misplaced and missing I beam support. Please re-measure and install steel column support -Insulate cantilevered joists before Solid-blocking -Header off cut joist near main duct in basement -Have engineer address the support for floor&roof at foyer/front dining. The double joist is not full length but cut at corner -Install 3-studs support for both lvl beams at mud and pantry ELECTRICAL: -Protect wiring at mud wall corner -Complete electrical above pantry -Damaged ceiling light&fan box above front bedroom PLUMBING: -Strap bearing wall top plates bored more than 50% above half bath -Protect plumbing at refrigerator -Protect water service line MECHANICAL: -Provide return air from front bedroom and pan off the unused stud space -Vent bath fan (shared bathroom) **OK TO INSULATE
All Rough Inspection - Residential Passed 11/7/2018 11/7/2018 11/07/2018
Misc
Resolved
11/07/2018
Driveway Inspection Partial 11/20/2018 11/20/2018
Misc
Informational
11/20/2018
Forms are in place, aggregate is compacted
Sidewalk Inspection Partial 11/20/2018 11/20/2018
Misc
Corrective Action Required
11/20/2018
Forms are out spec tolerance for cross slope, aggregate still needs to be compacted. We informed the flat workers. They will make corrections before pouring concrete
Driveway Inspection Passed 12/19/2018 12/19/2018
Misc
Informational
11/20/2018
Forms are in place, aggregate is compacted
Misc
Informational
12/19/2018
Driveway met specification.
Sidewalk Inspection Passed 12/19/2018 12/19/2018
Misc
Corrective Action Required
11/20/2018
Forms are out spec tolerance for cross slope, aggregate still needs to be compacted. We informed the flat workers. They will make corrections before pouring concrete
Misc
Informational
12/19/2018
Sidewalk met specifications.
Erosion Control Inspection Residential Passed 12/06/2019
DCM2 ESC DEFICIENT INSTALLATION
Resolved
12/06/2019
RE-INSTALL EROSION CONTROL ALONG THE STREET
Occupancy Inspection - Codes Residential Failed 12/6/2019 12/6/2019 at 12:50 PM 12/06/2019
Misc
Corrective Action Required
12/06/2019
-Lawn irrigation permit required -As-graded plot plan is required -Install tamper-proof caps at AC valves -Seal exterior wall penetrations, seal above meter and AC disconnect, seal exterior lights -Locate sewer tracer wire and install the sewer tracer box -Provide min 3 ft discharge at downspouts and sump pump discharge. Complete installing downspouts -Fasten support brackets to patio posts -The pantry/garage door must self-close -Provide mean to clean out furnace condensate drain -Locate and make accessible the sewer clean out
Occupancy Inspection - Codes Residential Failed 5/15/2020 5/15/2020 at 9:40 AM 05/15/2020
Misc
Corrective Action Required
12/06/2019
-Lawn irrigation permit required -As-graded plot plan is required -Locate sewer tracer wire and install the sewer tracer box **Sewer tracer wire, not gas tracer wire. -The pantry/garage door must self-close -Locate and make accessible the sewer clean out
Occupancy Inspection - Codes Residential Temporary C of O 5/20/2020 5/20/2020 at 2:50 PM 05/20/2020
Misc
Corrective Action Required
05/15/2020
-Lawn irrigation permit required -As-graded plot plan is required
Plot Plan Inspection Passed 10/19/2020 10/19/2020
Occupancy Inspection - Codes Residential Full C of O 10/19/2020
Misc
Resolved
10/19/2020
-As-graded plot plan is required
Documents & Images
Date Uploaded File Type Document Name
06/15/2018 Letter Codes Residential Plan Review
06/15/2018 Letter Codes Residential Plan Review
07/19/2018 Receipt Receipt for transaction: 2018-004997
07/19/2018 Letter Codes Building Permit
07/20/2018 Plot Plan DOC071918-07192018115346
07/24/2018 Letter Inspection Summary
07/27/2018 Letter Inspection Summary
08/20/2018 Letter Inspection Summary
08/21/2018 Letter Inspection Summary
08/29/2018 Letter Inspection Summary
10/26/2018 Letter Inspection Summary
11/01/2018 Letter Inspection Summary
11/20/2018 Letter INSPECTION SUMMARY
11/20/2018 Letter INSPECTION SUMMARY
12/06/2019 Letter INSPECTION SUMMARY
12/06/2019 Letter INSPECTION SUMMARY
05/15/2020 Letter INSPECTION SUMMARY
05/20/2020 Letter Codes Temporary Certificate of Occupancy
10/09/2020 Letter Codes 10 Day Letter
10/16/2020 Plot Plan As Graded Plot Plan
10/19/2020 Letter INSPECTION SUMMARY
10/19/2020 Letter Field Certificate of Occupancy
10/19/2020 Letter Codes Final Certificate of Occupancy
10/19/2020 Letter Inspection Summary
10/19/2020 Letter Inspection Summary
10/19/2020 Letter Inspection Summary
10/19/2020 Letter INSPECTION SUMMARY
10/19/2020 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home