Permit Application Status

PRRES20173068


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20173068
Building Permit - Residential
Certificate of Occupancy
D&D BUILDING INC
NEW SINGLE FAMILY
NEW HOUSE - COVERED DECK - FINISHED BASEMENT
09/13/2017
09/19/2017
08/16/2018
Locations
Contacts
D&D BUILDING INC, Address:PO BOX 7014  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
D AND D BUILDING INC, Address:PO BOX 7014, Phone:(816) 491-2125  
INTREPID ELECTRIC LLC, Address:620 S KISNER CIR, Phone:(816) 796-2781  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 09/15/2017 09/18/2017
Kim Brennan
07 Identify emergency escape openings from bedrooms
Corrective Action Required
09/13/2017

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance) in the master and bedroom #2
10 Combustion air
Corrective Action Required
09/13/2017

Provide combustion air calculations and specify transfer air grilles for fuel burning appliances located in confined space(s). (IRC Chapter 17 and Section G2407)
24 Concrete reinforcement size and spacing.
Corrective Action Required
09/13/2017

Concrete reinforcement size and spacing.
25 Concrete thickness.
Corrective Action Required
09/13/2017

Concrete thickness.
26 Concrete minimum compressive strength.
Corrective Action Required
09/13/2017

Concrete minimum compressive strength. (IRC Section 402.2)
37 Provide details for any walls over 10 feet in height.
Corrective Action Required
09/13/2017

Provide details for any walls over 10 feet in height. Include stud grade, size, spacing and actual, uninterrupted height. (IRC Section 602.3.1 and Table 602.3(5) & 602.3.1)
Plot Plan Review Approved 09/15/2017 09/13/2017
Nick Lightner
Lot elevations
Resolved
09/13/2017

Existing and finish elevations at all property corners must be provided on the plot plan. *Can you please double check the front property corners.
Basement opening elevations
Resolved
09/13/2017

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan. *Can you please provide the MBOE to the plot plan
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $951.88 $951.88 Paid 09/19/2017
Right of Way Permit Fee $75.00 $75.00 Paid 09/19/2017
8331507-Sewer Connection Fee $480.00 $480.00 Paid 09/19/2017
Water Tap Fee $3,343.00 $3,343.00 Paid 09/19/2017
Water Meter Fee $431.83 $431.83 Paid 09/19/2017
3rd and Subsequent Inspection Fee (Per Hour) $30.00 $30.00 Paid 08/15/2018
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 9/27/2017 (4:30) 9/27/2017 09/27/2017
Sewer Service Inspection - R Passed 10/17/2017 (11:30) 10/17/2017 at 1:35 PM 10/17/2017
Water Service Inspection - R Passed 10/18/2017 10/18/2017 at 10:10 AM 10/18/2017
Underslab Plumbing Inspection - Residential Passed 10/19/2017 10/18/2017 at 3:35 PM 10/18/2017
Erosion Control Inspection Residential Failed 10/18/2017 10/18/2017
Misc
Corrective Action Required
10/18/2017
PROVIDE GRAVEL FILTER AT DRIVEWAY
Suspended Slab Inspection Passed 10/31/2017 (3:00) 10/31/2017 at 4:05 PM 10/31/2017
Erosion Control Inspection Residential Partial 10/31/2017 at 4:11 PM 10/31/2017
Misc
Partial Correction
10/31/2017
COMPLIANT. PLEASE MAINTAIN
Piers/Caissons Inspection - Residential Passed 11/10/2017 at 10:20 AM 11/10/2017
Gas Service Inspection - Residential Passed 12/29/2017 12/29/2017 at 9:00 AM 12/29/2017
Electrical Service Inspection Passed 1/26/2018 1/26/2018 01/26/2018
All Rough Inspection - Residential Failed 1/26/2018 1/26/2018 at 10:10 AM 01/26/2018
Misc
Corrective Action Required
01/26/2018
**PROVIDE PLAN ON SITE FRAMING: -Add more nailing to H-frame; or install continuous strap over the LVL to top plate at the inner side per plan -Anchor out-of-plate anchor at rear garage wall; in basement rear bed, install anchor within 12" of sill break (short sill plate) -Nail corner studs per code -Install exterior doors and security blocking per code -Complete framing fireplace -Frame and nail Cs pf walls per plan -Fb duct space from roof -Non continuous studs at front bed -Toe nail joists to basement foundation wall sill plates -Fb basement fireplace space from joist space PLUMBING: -Connect gas line to fireplace -Protect 3” pvc at ceiling across from wet bar bath door MECHANICAL: -Air supply above master bath sink inside soffit space -Provide min 3” clearance above basement fireplace vent ELECTRICAL: -Receptacle within 25 ft of ac -Flood light at rear -Complete electrical at fireplaces -Secure wiring within 8“ of box at rear living rm wall , at master bath sink, and at basement bath sink **OK TO INSULATE
All Rough Inspection - Residential Not Ready 2/2/2018 2/2/2018 at 11:15 AM 02/02/2018
Misc
Corrective Action Required
01/26/2018
**PROVIDE PLAN ON SITE **FEB-2-NO PLAN ON SITE. REINSPECTION FEE ASSESSED FRAMING: -Add more nailing to H-frame; or install continuous strap over the LVL to top plate at the inner side per plan -Anchor out-of-plate anchor at rear garage wall; in basement rear bed, install anchor within 12" of sill break (short sill plate) -Nail corner studs per code -Install exterior doors and security blocking per code -Complete framing fireplace -Frame and nail Cs pf walls per plan -Fb duct space from roof -Non continuous studs at front bed -Toe nail joists to basement foundation wall sill plates -Fb basement fireplace space from joist space PLUMBING: -Connect gas line to fireplace -Protect 3” pvc at ceiling across from wet bar bath door MECHANICAL: -Air supply above master bath sink inside soffit space -Provide min 3” clearance above basement fireplace vent ELECTRICAL: -Receptacle within 25 ft of ac -Flood light at rear -Complete electrical at fireplaces -Secure wiring within 8“ of box at rear living rm wall , at master bath sink, and at basement bath sink **OK TO INSULATE
All Rough Inspection - Residential Failed 2/5/2018 2/5/2018 at 9:00 AM 02/05/2018
Misc
Corrective Action Required
02/02/2018
**PROVIDE PLAN ON SITE **FEB-2-NO PLAN ON SITE. REINSPECTION FEE ASSESSED FRAMING: -In basement rear bed, install anchor within 12" of sill break (short sill plate) -Complete framing fireplace **fireblock with 3/4" nominal sheathing, not 1/2" **fasten the fireplace to frame -Frame and nail Cs pf walls per plan **plan calls for brace wall detail for both the master bed and rear dining walls. Take a look at page 4&5. **Or have your designer revise the plan -Non continuous studs at front bed **reinforce with straps. Fyi: codes requires that the exterior wall studs must be continuous from floor to ceiling lateral support -Fb basement fireplace space from joist space MECHANICAL: -Provide min 3” clearance above basement fireplace vent **Take a look in fireplace installation document. Have this on site for reinspection **OK TO INSULATE
All Rough Inspection - Residential Failed 2/6/2018 2/6/2018 02/06/2018
Misc
Corrective Action Required
02/05/2018
-Complete framing fireplace **fireblock with 3/4" nominal sheathing, not 1/2" (FIRST FLOOR TO ATTIC STILL 1/2") -Frame and nail Cs pf walls per plan **plan calls for brace wall detail for both the master bed and rear dining walls. Take a look at page 4&5. **Or have your designer revise the plan (REAR DINING WALL, HEADER NEEDS TO BE CORNER TO CORNER, MASTER OKAY) -Non continuous studs at front bed **reinforce with straps. Fyi: codes requires that the exterior wall studs must be continuous from floor to ceiling lateral support -Fb basement fireplace space from joist space **OK TO INSULATE
All Rough Inspection - Residential Passed 2/8/2018 2/8/2018 at 9:25 AM 02/08/2018
Misc
Resolved
02/08/2018
-Frame and nail Cs pf walls per plan **plan calls for brace wall detail for both the master bed and rear dining walls. Take a look at page 4&5. **Or have your designer revise the plan (REAR DINING WALL, HEADER NEEDS TO BE CORNER TO CORNER, MASTER OKAY) -Non continuous studs at front bed **reinforce with straps. Fyi: codes requires that the exterior wall studs must be continuous from floor to ceiling lateral support -Fb basement fireplace space from joist space **OK TO INSULATE
All Rough Inspection - Residential Passed 2/9/2018 at 9:15 AM 02/09/2018
Driveway Inspection Partial 4/11/2018 at 9:25 AM 04/11/2018
Informational
04/11/2018
TTHOMPSON 04/11/2018 9:29 AM Inspected and forms are set up and sub grade is in place sufficiently
Driveway Inspection Passed 4/16/2018 at 11:05 AM 04/16/2018
Occupancy Inspection - Codes Residential Failed 4/18/2018 4/18/2018 at 8:40 AM 04/18/2018
Misc
Informational
02/02/2018
FEB-2-REINSPECTION FEE ASSESSED
Misc
Corrective Action Required
04/18/2018
-CLEAN THE STREET AND INSTALL TEMPORARY EROSION CONTROL ALONG STREET -REINSPECTION FEE ASSESSED ON FEB-2 SHALL BE PAID PRIOR TO ANY ISSUANCE OF OCCUPANCY -FINAL GRADE, SOD, SPLASHBLOCKS -SEWER TRACER -GARAGE AND PANTRY-GARAGE DOOR NOT SELF CLOSING -FIX GROUND FAULT CONDITION FOR KITCHEN COUNTERTOP RECEPTACLES -SECURE MC CABLES WITHIN 12" OF BOX UNDER KITCHEN SINK -ALL EXTERIOR DOORS: INSTALL SECURITY CODE COMPLIANT STRIKE PLATE WITH 3" SCREWS INTO STUDS -INSTALL BOX EXTENSION FOR FIREPLACE TV RECEPTACLE AND FLOOR RECEPTACLE -REFRIGERATOR RECEPTACLE WITHIN SIX FT OF THE BAR SINK MUST BE GFCI-PROTECTED -INSTALL LISTED CONNECTOR FOR THE LFNC RACEWAY CONNECTION TO WATER HEATER; SECURE WITHIN 12" -INSTALL BREAKER LOCK FOR OUT-OF-SIGHT WATER HEATER -BASEMENT BED SMOKE ALARM NOT INTERCONNECTE WITH THE REST OF HOUSE -ANCHOR BASEMENT STEEL COLUMNS
Erosion Control Inspection Residential Passed 05/18/2018
Misc
Resolved
05/18/2018
COMPLIANT. PLEASE MAINTAIN
Occupancy Inspection - Codes Residential Failed 5/18/2018 5/18/2018 at 9:15 AM 05/18/2018
Misc
Informational
04/18/2018
FEB-2-REINSPECTION FEE ASSESSED
Misc
Corrective Action Required
04/18/2018
-REINSPECTION FEE ASSESSED ON FEB-2 SHALL BE PAID PRIOR TO ANY ISSUANCE OF OCCUPANCY -FINAL GRADE, SPLASHBLOCKS **PROVIDE MIN. 6" CLEARANCE FROM BOTTOM OF THE SIDING TO GRADE **INSTALL SPLASHBLOCKS -ALL EXTERIOR DOORS: INSTALL SECURITY CODE COMPLIANT STRIKE PLATE WITH 3" SCREWS INTO STUDS **PLEASE GET THE PROPER STRIKE PLATE FROM THE DOOR MANUFACTURER/VENDOR.TYPICALLY, THIS STRIKE PLATE IS SCREWED INTO THE EMBEDDED BRACE W/ 4 SCREWS, AND THE EMBEDDED BRACE IS ITSELF SCREWED INTO THE JAMB STUDS WITH 4-3" SCREWS
Occupancy Inspection - Codes Residential Full C of O 8/16/2018 at 9:35 AM 08/16/2018
Misc
Resolved
08/16/2018
FEB-2-REINSPECTION FEE ASSESSED
Misc
Resolved
08/16/2018
-FINAL GRADE, SPLASHBLOCKS **PROVIDE MIN. 6" CLEARANCE FROM BOTTOM OF THE SIDING TO GRADE **INSTALL SPLASHBLOCKS -ALL EXTERIOR DOORS: INSTALL SECURITY CODE COMPLIANT STRIKE PLATE WITH 3" SCREWS INTO STUDS **PLEASE GET THE PROPER STRIKE PLATE FROM THE DOOR MANUFACTURER/VENDOR.TYPICALLY, THIS STRIKE PLATE IS SCREWED INTO THE EMBEDDED BRACE W/ 4 SCREWS, AND THE EMBEDDED BRACE IS ITSELF SCREWED INTO THE JAMB STUDS WITH 4-3" SCREWS
Documents & Images
Date Uploaded File Type Document Name
09/13/2017 Letter Codes Residential Plan Review
09/18/2017 Drawing Suspended slab layout
09/19/2017 Receipt Receipt for transaction: 2017-006438
09/19/2017 Letter Codes Building Permit
09/19/2017 Plot Plan DOC091917-001
09/27/2017 Letter Inspection Summary
10/17/2017 Letter Inspection Summary
10/18/2017 Letter Inspection Summary
10/18/2017 Letter Inspection Summary
10/31/2017 Letter Inspection Summary
11/10/2017 Letter Inspection Summary
12/29/2017 Letter Inspection Summary
01/26/2018 Letter Inspection Summary
02/02/2018 Letter Re-Inspection Fee
02/02/2018 Letter Inspection Summary
02/05/2018 Letter Inspection Summary
02/06/2018 Letter Inspection Summary
02/08/2018 Letter Inspection Summary
02/09/2018 Letter Inspection Summary
04/11/2018 Letter Inspection Summary
04/16/2018 Letter Inspection Summary
04/18/2018 Letter Inspection Summary
05/18/2018 Letter Inspection Summary
08/15/2018 Receipt Receipt for transaction: 2018-005754
08/16/2018 Letter Field Certificate of Occupancy
08/17/2018 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home