Permit Application Status

PRRES20171304


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20171304
Building Permit - Residential
Certificate of Occupancy
D AND D AVIATION INC
NEW SINGLE FAMILY
NEW SINGLE FAMILY SUSPENDED SLAB FINISHED BASEMENT
04/26/2017
05/05/2017
10/24/2017
12/19/2017
Locations
Contacts
D AND D AVIATION INC, Address:5282 NE ASH GROVE CT  
D AND D BUILDING INC, Address:PO BOX 7014, Phone:(816) 491-2125  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
INTREPID ELECTRIC LLC, Address:620 S KISNER CIR, Phone:(816) 796-2781  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 05/08/2017 05/05/2017
Jonathon Hilton
Property boundary
Corrective Action Required
05/04/2017

Property boundary distances and bearings, as shown on the recorded plat, must be provided on the plot plan. *Please check the N side of the lot property boundary
Basement opening elevations
Corrective Action Required
05/04/2017

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan. *Please include the MBOE on the plan.
Residential Plan Review Approved 05/08/2017 05/04/2017
Jonathon Hilton
Plot Plan Review Rejected 04/28/2017 04/27/2017
Nick Lightner
Property boundary
Corrective Action Required
04/27/2017

Property boundary distances and bearings, as shown on the recorded plat, must be provided on the plot plan. *Please check the N side of the lot property boundary
Basement opening elevations
Corrective Action Required
04/27/2017

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan. *Please include the MBOE on the plan.
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $928.68 $928.68 Paid 05/05/2017
8331507-Sewer Connection Fee $450.00 $450.00 Paid 05/05/2017
Water Tap Fee $3,310.00 $3,310.00 Paid 05/05/2017
Water Meter Fee $405.36 $405.36 Paid 05/05/2017
Right of Way Permit Fee $75.00 $75.00 Paid 05/05/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 5/9/2017 (1:30) 5/9/2017 05/09/2017
Underslab Plumbing Inspection - Residential Passed 5/24/2017 5/24/2017 05/24/2017
Sewer Service Inspection - R Passed 6/6/2017 (10:30) 6/6/2017 06/06/2017
Suspended Slab Inspection Partial 6/6/2017 06/06/2017
Misc
Corrective Action Required
06/06/2017
INSTALL REBAR CHAIRS
Water Service Inspection - R Passed 6/7/2017 6/7/2017 06/07/2017
Piers/Caissons Inspection - Residential Passed 6/12/2017 (9:00) 6/12/2017 06/12/2017
Piers/Caissons Inspection - Residential Failed 6/28/2017 (9:00) 6/28/2017 06/28/2017
Misc
Corrective Action Required
06/28/2017
-REMOVE TRASH AND LOOSE DIRT FROM MIDDLE PIER HOLE
Suspended Slab Inspection Passed 06/28/2017
Misc
Resolved
06/28/2017
INSTALL REBAR CHAIRS
Piers/Caissons Inspection - Residential Failed 6/28/2017 (1:30) 6/28/2017 06/28/2017
Misc
Corrective Action Required
06/28/2017
-REMOVE TRASH AND LOOSE DIRT FROM MIDDLE PIER HOLE **2ND SAME DAY RE-INSPECTION.NOTHING WAS DONE. WASTED TRIP FEE ASSESSED
Electrical Service Inspection Passed 7/21/2017 7/21/2017 07/21/2017
Gas Service Inspection - Residential Failed 7/21/2017 7/21/2017 07/21/2017
Misc
Corrective Action Required
07/21/2017
NO PRESSURE
All Rough Inspection - Residential Failed 7/21/2017 7/21/2017 07/21/2017
Misc
Corrective Action Required
07/21/2017
**PAINT/POST ADDRESS **REPAIR EROSION CONTROL AT FRONT AND BACK FRAMING: -PLAN ON SITE -GARAGE PORTAL BRACE WALLS: NAIL SHEATHING TO STUD, SILL PLATE, BLOCKING PER PLAN; STRAP LVL HEADER PER PLAN -PROVIDE ATTIC ACCESS -INSTALL HEADER AT FRONT BED DOOR TO CARRY RAFTERS LOAD -INSTALL EXTERIOR DOOR FRAMES PER SECURITY CODE -COMPLETE FRAMING AT BOTH FIREPLACES AND FIREBLOCK AS REQUIRED -SOLIDBLOCK CANTILEVERED JOISTS AT REAR -FIREBLOCKING: FB ALL FLOOR PENETRATIONS; FB BASEMENT WALL SPACE FROM CEILING SPACE (JOIST AND FURRED-DOWN SPACE); FB WALL VERTICALLY EVERY 10 FT MECHANICAL: -MIGHT NEED TO CHANGE DUCTING AT FIREPLACES AFTER FRAMING IS DONE PLUMBING: -CONNECT GAS LINES TO FIREPLACES. RETEST ***OK TO INSULATE
All Rough Inspection - Residential Failed 8/3/2017 8/3/2017 08/03/2017
Misc
Corrective Action Required
07/21/2017
8/3/17: INSPECTION DENIED - STILL NO ADDRESS OR EROSION CONTROL **PAINT/POST ADDRESS **REPAIR EROSION CONTROL AT FRONT AND BACK, NO FURTHER INSPECTIONS FRAMING: -PLAN ON SITE -GARAGE PORTAL BRACE WALLS: NAIL SHEATHING TO STUD, SILL PLATE, BLOCKING PER PLAN; STRAP LVL HEADER PER PLAN -PROVIDE ATTIC ACCESS -INSTALL HEADER AT FRONT BED DOOR TO CARRY RAFTERS LOAD -INSTALL EXTERIOR DOOR FRAMES PER SECURITY CODE -COMPLETE FRAMING AT BOTH FIREPLACES AND FIREBLOCK AS REQUIRED -SOLIDBLOCK CANTILEVERED JOISTS AT REAR -FIREBLOCKING: FB ALL FLOOR PENETRATIONS; FB BASEMENT WALL SPACE FROM CEILING SPACE (JOIST AND FURRED-DOWN SPACE); FB WALL VERTICALLY EVERY 10 FT MECHANICAL: -MIGHT NEED TO CHANGE DUCTING AT FIREPLACES AFTER FRAMING IS DONE PLUMBING: -CONNECT GAS LINES TO FIREPLACES. RETEST ***OK TO INSULATE
Erosion Control Inspection Residential Failed 8/3/2017 08/03/2017
Gas Service Inspection - Residential Failed 8/8/2017 08/08/2017
Misc
Corrective Action Required
07/21/2017
NO PRESSURE
All Rough Inspection - Residential Failed 8/8/2017 8/8/2017 08/08/2017
Misc
Corrective Action Required
08/03/2017
**REPAIR EROSION CONTROL AT BACK. NO FURTHER INSPECTIONS IF EROSION CONTROL IS NOT IN COMPLIANCE FRAMING: -PLAN ON SITE **HAVE THE CITY-APPROVED PLAN ON SITE -GARAGE PORTAL BRACE WALLS: NAIL SHEATHING TO STUD, SILL PLATE, BLOCKING, AND LVL HEADER PER PLAN -INSTALL EXTERIOR DOOR FRAMES PER SECURITY CODE **FILL IN GAP AT HINGES AND STRIKE PLATE SIDE WITH SOLID WOOD; INSTALL SECURITY BLOCKING -COMPLETE FRAMING AT BOTH FIREPLACES AND FIREBLOCK AS REQUIRED **NEED TO FIREBLOCK THE BASEMENT FIREPLACE SPACE FROM JOIST SPACE **AT BOTH FIREPLACES, RE-DUCT THE TRANSFER AIR OPENINGS -FIREBLOCKING: FB BASEMENT WALL SPACE FROM CEILING SPACE (JOIST AND FURRED-DOWN SPACE); FB WALL VERTICALLY EVERY 10 FT MECHANICAL: -CHANGE AIR TRANSFER DUCTING AT FIREPLACES ***OK TO INSULATE
All Rough Inspection - Residential Failed 8/10/2017 8/10/2017 08/10/2017
Misc
Corrective Action Required
08/08/2017
FRAMING: -PLAN ON SITE **HAVE THE CITY-APPROVED PLAN ON SITE -GARAGE PORTAL BRACE WALLS: NAIL SHEATHING TO STUD, SILL PLATE, BLOCKING, AND LVL HEADER PER PLAN **BOTH BRACE WALLS AT EACH SIDE OF THE DOOR -INSTALL EXTERIOR DOOR FRAMES PER SECURITY CODE **FILL IN GAP AT HINGES AND STRIKE PLATE SIDE WITH SOLID WOOD FOR BOTH DOORS. FOAM IS NOT SOLID WOOD -FIREBLOCKING: FB BASEMENT WALL SPACE FROM CEILING SPACE (JOIST AND FURRED-DOWN SPACE); ***DO NOT ROCK
All Rough Inspection - Residential Passed 8/11/2017 8/11/2017 at 10:50 AM 08/11/2017
Misc
Resolved
08/11/2017
FRAMING: -PLAN ON SITE **HAVE THE CITY-APPROVED PLAN ON SITE -GARAGE PORTAL BRACE WALLS: NAIL SHEATHING TO STUD, SILL PLATE, BLOCKING, AND LVL HEADER PER PLAN **BOTH BRACE WALLS AT EACH SIDE OF THE DOOR -INSTALL EXTERIOR DOOR FRAMES PER SECURITY CODE **FILL IN GAP AT HINGES AND STRIKE PLATE SIDE WITH SOLID WOOD FOR BOTH DOORS. FOAM IS NOT SOLID WOOD -FIREBLOCKING: FB BASEMENT WALL SPACE FROM CEILING SPACE (JOIST AND FURRED-DOWN SPACE); ***DO NOT ROCK
Gas Service Inspection - Residential Failed 8/11/2017 8/11/2017 08/11/2017
Misc
Corrective Action Required
08/08/2017
NO PRESSURE
All Rough Inspection - Residential Failed 8/11/2017 08/11/2017
Misc
Corrective Action Required
08/11/2017
-FIREBLOCK THE WALL SPACE FROM SOFFITS OUTSIDE BASEMENT BATH AND FROM SOFFIT INSIDE BEDROOM
All Rough Inspection - Residential Passed 8/14/2017 08/14/2017
Misc
Resolved
08/14/2017
-FIREBLOCK THE WALL SPACE FROM SOFFITS OUTSIDE BASEMENT BATH AND FROM SOFFIT INSIDE BEDROOM
Gas Service Inspection - Residential Failed 8/14/2017 08/14/2017
Misc
Corrective Action Required
08/11/2017
NO PRESSURE
Gas Service Inspection - Residential Passed 8/15/2017 8/15/2017 at 9:35 AM 08/15/2017
Misc
Resolved
08/15/2017
NO PRESSURE
Driveway Inspection Partial 11/21/2017 11/21/2017 at 10:46 AM 11/21/2017
Sidewalk Inspection Partial 11/21/2017 11/21/2017 at 10:51 AM 11/21/2017
Driveway Inspection Passed 12/12/2017 at 3:10 PM 12/12/2017
Sidewalk Inspection Passed 12/12/2017 at 3:15 PM 12/12/2017
Piers/Caissons Inspection - Residential Passed 12/13/2017
Misc
Resolved
12/13/2017
-REMOVE TRASH AND LOOSE DIRT FROM MIDDLE PIER HOLE **2ND SAME DAY RE-INSPECTION.NOTHING WAS DONE. WASTED TRIP FEE ASSESSED
Occupancy Inspection - Codes Residential Failed 12/13/2017 12/13/2017 at 3:05 PM 12/13/2017
Misc
Corrective Action Required
12/13/2017
-HAVE THE LAWN IRRIGATION GUY SUBMIT THE BACKFLOW TEST REPORT TO THE CITY -EXPOSE SEWER TRACER BOX -AC DISCONNECT: THE INNER PLASTIC COVER IS MISSING; ID THE UNGROUNDED CONDUCTORS WITH PROPER COLOR. WHITE IS FOR GROUNDED CONDUCTORS -INSTALL SPLASHBLOCKS -DEDICATE (SINGLE PLUG) THE RECEPTACLE FOR THE ALARM CONTROL BOX OR PROVIDE GFCI PROTECTION
Occupancy Inspection - Codes Residential Full C of O 12/19/2017 12/19/2017 at 11:05 AM 12/19/2017
Misc
Resolved
12/19/2017
-EXPOSE SEWER TRACER BOX -AC DISCONNECT: THE INNER PLASTIC COVER IS MISSING; ID THE UNGROUNDED CONDUCTORS WITH PROPER COLOR. WHITE IS FOR GROUNDED CONDUCTORS -INSTALL SPLASHBLOCKS -DEDICATE (SINGLE PLUG) THE RECEPTACLE FOR THE ALARM CONTROL BOX OR PROVIDE GFCI PROTECTION
Documents & Images
Date Uploaded File Type Document Name
04/27/2017 Letter Codes Residential Plan Review
05/05/2017 Receipt Receipt for transaction: 2017-001860
05/05/2017 Letter Codes Building Permit
05/09/2017 Letter Inspection Summary
05/09/2017 Plot Plan DOC050917-017
05/09/2017 Engineer Report/Study DOC050917-018
05/24/2017 Letter Inspection Summary
06/06/2017 Letter Inspection Summary
06/06/2017 Letter Inspection Summary
06/07/2017 Letter Inspection Summary
06/12/2017 Letter Inspection Summary
06/28/2017 Letter Inspection Summary
06/28/2017 Letter Re-Inspection Fee
06/28/2017 Letter Inspection Summary
07/21/2017 Letter Inspection Summary
08/03/2017 Letter Inspection Summary
08/08/2017 Letter Inspection Summary
08/10/2017 Letter Inspection Summary
08/11/2017 Letter Inspection Summary
08/11/2017 Letter Inspection Summary
08/14/2017 Letter Inspection Summary
08/15/2017 Letter Inspection Summary
12/13/2017 Letter Inspection Summary
12/18/2017 inspection report 20171304
12/19/2017 Letter Field Certificate of Occupancy
12/20/2017 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home