Review Type |
Outcome |
Est. Completion Date |
Completed |
Licensed Contractors
|
Approved
|
04/30/2025
|
04/30/2025
|
|
Joe Frogge
|
|
|
Building Plan Review
|
Approved with Conditions
|
04/30/2025
|
04/30/2025
|
|
Joe Frogge
|
|
License Tax - Payment
Corrective Action Required
A one-time impact fee in the form of an excise tax must be collected before occupancy can be granted. Please be advised that additional application, review, and inspection fees do apply and additional information pertaining to this will be provided during that stage of your approval process.
Action required: Comment is for informational purposes. The fee will be $7,084.00
4/18/2025 - not addressed.
|
|
|
Fire Plan Review
|
Approved
|
04/30/2025
|
04/29/2025
|
|
Craig Hill
|
|
Misc
Action Required: Provide storage plans for the expansion area to comply with the 2018 International Fire Code Section. The open area storage shall be arranged so that it does not obstruct required fire department access or impede the safe exiting of the occupants of the building.
|
|
Miscellaneous Correction
Provide demarcation lines in the storage area showing exit isals and designated pallet storage areas.
|
|
Portable fire extinguishers - conspicuous locations
2018 IFC 906.5- Conspicuous location. Portable fire extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel.
Action Required: Provide storage plans for the expansion area to comply with the 2018 International Fire Code Section on travel distance to portable fire extinguishers. Storage plan is needed to prevent occupant from storing and stacking pallets in a way that impedes access to extinguishers.
|
|
|
Fire Plan Review
|
Rejected
|
04/21/2025
|
04/21/2025
|
|
Craig Hill
|
|
Misc
Corrective Action Required
Action Required: Provide storage plans for the expansion area to comply with the 2018 International Fire Code Section. The open area storage shall be arranged so that it does not obstruct required fire department access or impede the safe exiting of the occupants of the building.
|
|
Miscellaneous Correction
Corrective Action Required
Provide demarcation lines in the storage area showing exit isals and designated pallet storage areas.
|
|
Portable fire extinguishers - conspicuous locations
Corrective Action Required
2018 IFC 906.5- Conspicuous location. Portable fire extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel.
Action Required: Provide storage plans for the expansion area to comply with the 2018 International Fire Code Section on travel distance to portable fire extinguishers. Storage plan is needed to prevent occupant from storing and stacking pallets in a way that impedes access to extinguishers.
|
|
|
Building Plan Review
|
Approved with Conditions
|
04/21/2025
|
04/21/2025
|
|
Joe Frogge
|
|
IBC 716.2.3 Fire and Smoke Protection - fire doors
2018 IBC 716.2.3 Fire doors. Fire doors installed within a fire door assembly shall meet the fire rating indicated in Table 716.1(2).
Action required: Specify ratings for doors installed in rated wall. (wall along column line G is 1hr rated)
|
|
Project cost
The project cost, which is used to establish the permit fee, has not been provided.
Action required: Comment is informational.
4/18/2025 - not addressed.
|
|
License Tax - Payment
Corrective Action Required
A one-time impact fee in the form of an excise tax must be collected before occupancy can be granted. Please be advised that additional application, review, and inspection fees do apply and additional information pertaining to this will be provided during that stage of your approval process.
Action required: Comment is for informational purposes. The fee will be $7,084.00
4/18/2025 - not addressed.
|
|
|
Licensed Contractors
|
Approved
|
04/21/2025
|
04/18/2025
|
|
Joe Frogge
|
|
|
Fire Plan Review
|
Rejected
|
04/11/2025
|
04/11/2025
|
|
Craig Hill
|
|
Misc
Corrective Action Required
Action Required: Provide racking and storage plans for the expansion area to comply with the 2018 International Fire Code Section. The open area storage shall be arranged so that it does not obstruct required fire department access or hinder the operation of fire protection systems, such as sprinklers it should also not impede the safe exiting of the occupants of the building.
|
|
|
Building Plan Review
|
Rejected
|
04/11/2025
|
04/08/2025
|
|
Joe Frogge
|
|
IBC 716.2.3 Fire and Smoke Protection - fire doors
Corrective Action Required
2018 IBC 716.2.3 Fire doors. Fire doors installed within a fire door assembly shall meet the fire rating indicated in Table 716.1(2).
Action required: Specify ratings for doors installed in rated wall. (wall along column line G is 1hr rated)
|
|
Project cost
Corrective Action Required
The project cost, which is used to establish the permit fee, has not been provided.
Action required: Comment is informational.
|
|
License Tax - Payment
Corrective Action Required
A one-time impact fee in the form of an excise tax must be collected before occupancy can be granted. Please be advised that additional application, review, and inspection fees do apply and additional information pertaining to this will be provided during that stage of your approval process.
Action required: Comment is for informational purposes. The fee will be $7,084.00
|
|
|
Licensed Contractors
|
Approved
|
04/11/2025
|
04/08/2025
|
|
Joe Frogge
|
|
|