Permit Application Status

PRCOM20222664


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRCOM20222664
Building Permit - Commercial
Certificate of Occupancy
NEW TENANT FINISH
CAVA - TENANT FINISH FOR NEW RESTAURANT
06/14/2022
12/05/2022
01/25/2023
04/12/2023
Locations
Contacts
Pine Ridge Construction Management LLC, Address:1000 Commerce Park Dr., Suite 518, Phone:(570) 505-3890 Ext:340  
JAKE DEMPEWOL, Phone:(405) 833-9813  
BETTER SERVICE INC, Address:4512 MAIN ENTRANCE DRIVE 3, Phone:(816) 744-4617 Ext:CELL  
SHAW ELECTRIC COMPANY, Address:3600 FULLER, Phone:(816) 921-0033  
BETTER SERVICE INC, Address:4512 MAIN ENTRANCE DRIVE 3, Phone:(816) 744-4617 Ext:CELL  
red architecture + planning, Address:589 W Nationwide Blvd, suite b, Phone:(614) 487-8770  
Reviews
Review Type Outcome Est. Completion Date Completed
Alarm Plan Review Released for Construction 02/17/2023
Jim Eden
Construction documents for fire alarm systems
Corrective Action Required
02/17/2023

2018 IFC 907.1.1- Construction documents. Construction documents for fire alarm systems shall be submitted for review and approval prior to system installation. Construction documents shall include, but not be limited to, all of the following: 1. .A floor plan which indicates the use of all rooms. 2. Locations of alarm-initiating and notification appliances. 3. Alarm control and trouble signaling equipment. 4. Annunciation. 5. Power connection. 6. Battery calculations. 7. Conductor type and sizes. 8. Voltage drop calculations. 9. Manufacturers, model numbers and listing information for equipment, devices and materials. 10. Details of ceiling height and construction. 11. The interface of fire safety control functions. Plans received.
Installation acceptance testing
Corrective Action Required
02/17/2023

2018 IFC 901.5- Installation acceptance testing. Fire detection and alarm systems, fire-extinguishing systems, fire hydrant systems, fire standpipe systems, fire pump systems, private fire service mains and all other fire protection systems and appurtenances thereto shall be subject to acceptance tests as contained in the installation standards and as approved by the fire code official. The fire code official shall be notified before any required acceptance testing. The fire code official shall be notified 48 hours before any required acceptance test. Call (816) 969-1300 to schedule an alarm test.
Licensed Contractors Approved 08/08/2022 11/23/2022
Joe Frogge
LC - General Contractor
Resolved
11/23/2022

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Either a Class A or Class B license is required. Provide the company name of the licensed general contractor and an email address & phone number for the on-site contact which is where inspection reports will be sent. 7/22/22 - acknowledged in letter
LC - MEP Subs
Resolved
11/23/2022

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors. 7/22/22 - acknowledged in letter
Building Plan Review Approved with Conditions 10/10/2022 10/10/2022
Joe Frogge
Health Dept Inspection
Corrective Action Required
10/03/2022

For the Health Department inspection contact Deb Sees with the Jackson County Public Works Department, Environmental Health Division at (816) 847-7070. Health Department approval is required prior to receiving any type of Occupancy from the City of Lee's Summit. Action required: Comment is for informational purposes.
Fire Plan Review Approved with Conditions 10/10/2022 10/06/2022
Ben Hicks
Portable fire extinguishers for commercial cooking equipment.
Resolved
10/06/2022

2018 IFC 904.11.5- Portable fire extinguishers for commercial cooking equipment. Portable fire extinguishers shall be provided within a 30-foot (9144 mm) travel distance of commercial-type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. Action required- Place the K class extinguisher under the manual pull for the ansul system.
Installation acceptance testing
Corrective Action Required
10/06/2022

2018 IFC 901.5- Installation acceptance testing. Fire detection and alarm systems, fire-extinguishing systems, fire hydrant systems, fire standpipe systems, fire pump systems, private fire service mains and all other fire protection systems and appurtenances thereto shall be subject to acceptance tests as contained in the installation standards and as approved by the fire code official. The fire code official shall be notified before any required acceptance testing. The fire code official shall be notified 48 hours before any required acceptance test. Action required- Call (816) 969-1300 to schedule a hood trip test.
Building Plan Review Approved with Conditions 08/15/2022 08/08/2022
Joe Frogge
Misc
Resolved
08/08/2022

Per our Planning Department (see email in portal) a 4' tall fence is required around exterior patio. Where there is a potential car overlap 2' will be assumed to be forfeit. i.e. if a car bumper can overlap walkway near fence, 6' would be required. Action required: Modify designs to comply. If egress gates not provided, the seating area will need to be added to building occupant load. 7/22/22 - not found in submittal. Site plan and FFE appear unchanged.
Health Dept Inspection
Corrective Action Required
08/08/2022

For the Health Department inspection contact Deb Sees with the Jackson County Public Works Department, Environmental Health Division at (816) 847-7070. Health Department approval is required prior to receiving any type of Occupancy from the City of Lee's Summit. Action required: Comment is for informational purposes.
Fire Plan Review Approved with Conditions 08/15/2022 08/08/2022
Joe Frogge
Portable fire extinguishers for commercial cooking equipment.
Informational
08/08/2022

2018 IFC 904.11.5- Portable fire extinguishers for commercial cooking equipment. Portable fire extinguishers shall be provided within a 30-foot (9144 mm) travel distance of commercial-type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. Action required- Place the K class extinguisher under the manual pull for the ansul system.
Installation acceptance testing
Informational
08/08/2022

2018 IFC 901.5- Installation acceptance testing. Fire detection and alarm systems, fire-extinguishing systems, fire hydrant systems, fire standpipe systems, fire pump systems, private fire service mains and all other fire protection systems and appurtenances thereto shall be subject to acceptance tests as contained in the installation standards and as approved by the fire code official. The fire code official shall be notified before any required acceptance testing. The fire code official shall be notified 48 hours before any required acceptance test. Action required- Call (816) 969-1300 to schedule a hood trip test.
Fire Plan Review Approved with Conditions 07/29/2022 07/29/2022
Jim Eden
Emergency power for illumination
Resolved
07/29/2022

2018 IFC 1008.3.1 & 3.2 Emergency power for illumination. The power supply for means of egress illumination shall normally be provided by the premises' electrical supply. In the event of power supply failure, an emergency electrical system shall automatically illuminate all of the following: 1. Aisles and unenclosed egress stairways in rooms and spaces that require two or mor means of egress. 2. Corridors, interior exit stairways and ramps and exit passageways in buildings required to have two or more exits. 3. Exterior egress components at other than their levels of exit discharge until exit discharge is accomplished for buildings required to have two or more exits. Action required- Provide emergency exterior illumination at both exits.
Portable fire extinguishers for commercial cooking equipment.
Informational
07/29/2022

2018 IFC 904.11.5- Portable fire extinguishers for commercial cooking equipment. Portable fire extinguishers shall be provided within a 30-foot (9144 mm) travel distance of commercial-type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. Action required- Place the K class extinguisher under the manual pull for the ansul system.
Installation acceptance testing
Informational
07/29/2022

2018 IFC 901.5- Installation acceptance testing. Fire detection and alarm systems, fire-extinguishing systems, fire hydrant systems, fire standpipe systems, fire pump systems, private fire service mains and all other fire protection systems and appurtenances thereto shall be subject to acceptance tests as contained in the installation standards and as approved by the fire code official. The fire code official shall be notified before any required acceptance testing. The fire code official shall be notified 48 hours before any required acceptance test. Action required- Call (816) 969-1300 to schedule a hood trip test.
Miscellaneous Correction
Resolved
07/29/2022

5307.2.1 Gas detection system. In rooms or areas not provided with ventilation in accordance with Section 5307.2, a gas detection system complying with Section 916 or, where approved, an oxygen depletion alarm system, either of which initiates audible and visible alarm signals in the room or area where sensors are installed, shall be provided. Action required- Provide detection or ventilation for the carbon dioxide beverage system provided.
Building Plan Review Rejected 07/29/2022 07/22/2022
Joe Frogge
IPC 1003.3.1 Grease interceptors
Resolved
07/22/2022

2018 IPC 1003.3.1 Grease interceptors and automatic grease removal devices required. A grease interceptor or automatic grease removal device shall be required to receive the drainage from fixtures and equipment with grease-laden waste located in food preparation areas, such as in restaurants, hotel kitchens, hospitals, school kitchens, bars, factory cafeterias and clubs. Fixtures and equipment shall include pot sinks, pre-rinse sinks; soup kettles or similar devices; work stations; floor drains or sinks into which kettles are drained; automatic hood wash units and dishwashers without pre-rinse sinks. Grease interceptors and automatic grease removal devices shall receive waste only from fixtures and equipment that allow fats, oils or grease to be discharged. Where lack of space or other constraints prevent the installation or replacement of a grease interceptor, one or more grease interceptors shall be permitted to be installed on or above the floor and upstream of an existing grease interceptor. Action required: Grease interceptor sizing as shown on P501 (1,250 gpm) exceeds size of interceptor proposed in FDP and shell designs which is only 1,000 gpm. clarify. If size increases, those project designs will have to be amended.
Misc
Corrective Action Required
07/22/2022

Per our Planning Department (see email in portal) a 4' tall fence is required around exterior patio. Where there is a potential car overlap 2' will be assumed to be forfeit. i.e. if a car bumper can overlap walkway near fence, 6' would be required. Action required: Modify designs to comply. If egress gates not provided, the seating area will need to be added to building occupant load. 7/22/22 - not found in submittal. Site plan and FFE appear unchanged.
Health Dept Inspection
Corrective Action Required
07/22/2022

For the Health Department inspection contact Deb Sees with the Jackson County Public Works Department, Environmental Health Division at (816) 847-7070. Health Department approval is required prior to receiving any type of Occupancy from the City of Lee's Summit. Action required: Comment is for informational purposes.
IBC 1008.3 Emergency power for illumination - at exit discharge
Resolved
07/22/2022

2018 IBC 1008.3 Emergency power for illumination. The power supply for means of egress illumination shall normally be provided by the premises’ electrical supply. 1008.3.1 General. In the event of power supply failure in rooms and spaces that require two or more means of egress, an emergency electrical system shall automatically illuminate all of the following areas: 1. Aisles. 2. Corridors. 3. Exit access stairways and ramps. 1008.3.2 Buildings. In the event of power supply failure in buildings that require two or more means of egress, an emergency electrical system shall automatically illuminate all of the following areas: 1. Interior exit access stairways and ramps. 2. Interior and exterior exit stairways and ramps. 3. Exit passageways. 4. Vestibules and areas on the level of discharge used for exit discharge in accordance with Section 1028.1. 5. Exterior landings as required by Section 1010.1.6 for exit doorways that lead directly to the exit discharge. 1008.3.3 Rooms and Spaces. In the event of power supply failure an emergency electrical system shall automatically illuminate all of the following areas: 1. Electrical equipment rooms. 2. Fire command centers. 3. Fire pump rooms. 4. Generator rooms. 5. Public restrooms with an area greater than 300 square feet. Action required: Provide emergency lighting at exterior side of exits. (or provide verification of existing)
Licensed Contractors Rejected 07/29/2022 07/22/2022
Joe Frogge
LC - General Contractor
Corrective Action Required
07/22/2022

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Either a Class A or Class B license is required. Provide the company name of the licensed general contractor and an email address & phone number for the on-site contact which is where inspection reports will be sent. 7/22/22 - acknowledged in letter
LC - MEP Subs
Corrective Action Required
07/22/2022

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors. 7/22/22 - acknowledged in letter
Health Department Review Approved 07/12/2022
Joe Frogge
Building Plan Review Rejected 06/24/2022 06/23/2022
Joe Frogge
IPC 1003.3.1 Grease interceptors
Corrective Action Required
06/23/2022

2018 IPC 1003.3.1 Grease interceptors and automatic grease removal devices required. A grease interceptor or automatic grease removal device shall be required to receive the drainage from fixtures and equipment with grease-laden waste located in food preparation areas, such as in restaurants, hotel kitchens, hospitals, school kitchens, bars, factory cafeterias and clubs. Fixtures and equipment shall include pot sinks, pre-rinse sinks; soup kettles or similar devices; work stations; floor drains or sinks into which kettles are drained; automatic hood wash units and dishwashers without pre-rinse sinks. Grease interceptors and automatic grease removal devices shall receive waste only from fixtures and equipment that allow fats, oils or grease to be discharged. Where lack of space or other constraints prevent the installation or replacement of a grease interceptor, one or more grease interceptors shall be permitted to be installed on or above the floor and upstream of an existing grease interceptor. Action required: Grease interceptor sizing as shown on P501 (1,250 gpm) exceeds size of interceptor proposed in FDP and shell designs which is only 1,000 gpm. clarify. If size increases, those project designs will have to be amended.
Misc
Corrective Action Required
06/23/2022

Per our Planning Department (see email in portal) a 4' tall fence is required around exterior patio. Where there is a potential car overlap 2' will be assumed to be forfeit. i.e. if a car bumper can overlap walkway near fence, 6' would be required. Action required: Modify designs to comply. If egress gates not provided, the seating area will need to be added to building occupant load.
Health Dept Review
Resolved
07/12/2022

For the Health Department review contact Deb Sees with the Jackson County Public Works Department, Environmental Services Division, at (816) 847-7070. Health Department approval is required prior to receiving any type of building permit from the City of Lee's Summit. Action required: Comment is for informational purposes.
Health Dept Inspection
Corrective Action Required
06/23/2022

For the Health Department inspection contact Deb Sees with the Jackson County Public Works Department, Environmental Health Division at (816) 847-7070. Health Department approval is required prior to receiving any type of Occupancy from the City of Lee's Summit. Action required: Comment is for informational purposes.
IBC 1008.3 Emergency power for illumination - at exit discharge
Corrective Action Required
06/23/2022

2018 IBC 1008.3 Emergency power for illumination. The power supply for means of egress illumination shall normally be provided by the premises’ electrical supply. 1008.3.1 General. In the event of power supply failure in rooms and spaces that require two or more means of egress, an emergency electrical system shall automatically illuminate all of the following areas: 1. Aisles. 2. Corridors. 3. Exit access stairways and ramps. 1008.3.2 Buildings. In the event of power supply failure in buildings that require two or more means of egress, an emergency electrical system shall automatically illuminate all of the following areas: 1. Interior exit access stairways and ramps. 2. Interior and exterior exit stairways and ramps. 3. Exit passageways. 4. Vestibules and areas on the level of discharge used for exit discharge in accordance with Section 1028.1. 5. Exterior landings as required by Section 1010.1.6 for exit doorways that lead directly to the exit discharge. 1008.3.3 Rooms and Spaces. In the event of power supply failure an emergency electrical system shall automatically illuminate all of the following areas: 1. Electrical equipment rooms. 2. Fire command centers. 3. Fire pump rooms. 4. Generator rooms. 5. Public restrooms with an area greater than 300 square feet. Action required: Provide emergency lighting at exterior side of exits. (or provide verification of existing)
Licensed Contractors Rejected 06/24/2022 06/23/2022
Joe Frogge
LC - General Contractor
Corrective Action Required
06/23/2022

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Either a Class A or Class B license is required. Provide the company name of the licensed general contractor and an email address & phone number for the on-site contact which is where inspection reports will be sent.
LC - MEP Subs
Corrective Action Required
06/23/2022

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors.
Fire Plan Review Approved with Conditions 06/24/2022 06/22/2022
Jim Eden
Emergency power for illumination
Corrective Action Required
06/22/2022

2018 IFC 1008.3.1 & 3.2 Emergency power for illumination. The power supply for means of egress illumination shall normally be provided by the premises' electrical supply. In the event of power supply failure, an emergency electrical system shall automatically illuminate all of the following: 1. Aisles and unenclosed egress stairways in rooms and spaces that require two or mor means of egress. 2. Corridors, interior exit stairways and ramps and exit passageways in buildings required to have two or more exits. 3. Exterior egress components at other than their levels of exit discharge until exit discharge is accomplished for buildings required to have two or more exits. Action required- Provide emergency exterior illumination at both exits.
Portable fire extinguishers for commercial cooking equipment.
Corrective Action Required
06/22/2022

2018 IFC 904.11.5- Portable fire extinguishers for commercial cooking equipment. Portable fire extinguishers shall be provided within a 30-foot (9144 mm) travel distance of commercial-type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. Action required- Place the K class extinguisher under the manual pull for the ansul system.
Installation acceptance testing
Corrective Action Required
06/22/2022

2018 IFC 901.5- Installation acceptance testing. Fire detection and alarm systems, fire-extinguishing systems, fire hydrant systems, fire standpipe systems, fire pump systems, private fire service mains and all other fire protection systems and appurtenances thereto shall be subject to acceptance tests as contained in the installation standards and as approved by the fire code official. The fire code official shall be notified before any required acceptance testing. The fire code official shall be notified 48 hours before any required acceptance test. Action required- Call (816) 969-1300 to schedule a hood trip test.
Miscellaneous Correction
Corrective Action Required
06/22/2022

5307.2.1 Gas detection system. In rooms or areas not provided with ventilation in accordance with Section 5307.2, a gas detection system complying with Section 916 or, where approved, an oxygen depletion alarm system, either of which initiates audible and visible alarm signals in the room or area where sensors are installed, shall be provided. Action required- Provide detection or ventilation for the carbon dioxide beverage system provided.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New Tenent Finish $2,400.00 $2,400.00 Paid 12/01/2022
7232302-Commercial License Tax Fee $14,662.50 $14,662.50 Paid 12/01/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 04/03/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Commercial Passed 12/14/2022 12/14/2022 12/14/2022
Water Service Inspection Failed 1/6/2023 01/06/2023
Miscellaneous Correction
Corrective Action Required
01/06/2023
1-6-23 DP. Meter pit needs to be replaced and moved. The meter also needs to be raised to 14-18" from top of meter to bottom of lid.
In-wall Inspection Failed 1/23/2023 1/23/2023 01/23/2023
Misc
Corrective Action Required
01/23/2023
-Complete all MEPs at dining area walls -Secure mc within 12" of all boxes and max 6' vertical -Provide midpoint strap at all 2" and smaller DWV -Protect all DWV within 1.25" to face of framing-Protect min. 2" above and below plate lines -Seal all plate penetrations concealed in combustible framing -Seal through penetrations in firewall -Relocate water and DWV lines in electrical panel working space
In-wall Inspection Failed 1/25/2023 1/25/2023 01/25/2023
Misc
Corrective Action Required
01/23/2023
-Protect all DWV within 1.25" to face of framing-Horizontal runs through studs -Seal all plate penetrations concealed in combustible framing-Dwv in mechanical room -Seal through penetrations in firewall -Relocate water and DWV lines in electrical panel working space
In-wall Inspection Partial 1/26/2023 1/26/2023 01/26/2023
Misc
Resolved
01/26/2023
-Relocate water and DWV lines in electrical panel working space
Above Ceiling Inspection Partial 3/20/2023 3/20/2023 03/20/2023
Misc
Informational
03/20/2023
ABOVE-CEILING APPROVED TO COVER: -HALLWAY RM106 AND BOTH RESTROOMS
Hood/Duct Inspection Partial 3/24/2023 3/24/2023 03/24/2023
Misc
Corrective Action Required
03/24/2023
-Captive air system Provide documentation for installed system. will check at next above ceiling inspection
Above Ceiling Inspection Partial 3/24/2023 03/24/2023
Misc
Informational
03/24/2023
ABOVE-CEILING APPROVED TO COVER: -HALLWAY RM106 AND BOTH RESTROOMS, DINNING AREA
Above Ceiling Inspection Failed 3/29/2023 3/29/2023 03/29/2023
Misc
Informational
03/24/2023
ABOVE-CEILING APPROVED TO COVER: -HALLWAY RM106 AND BOTH RESTROOMS, DINNING AREA 3/29/23 Kitchen area not ready
Hood/Duct Inspection Passed 3/30/2023 03/30/2023
Misc
Resolved
03/30/2023
-Captive air system Provide documentation for installed system. will check at next above ceiling inspection
Above Ceiling Inspection Passed 3/30/2023 3/30/2023 03/30/2023
Misc
Resolved
03/30/2023
ABOVE-CEILING APPROVED TO COVER: -HALLWAY RM106 AND BOTH RESTROOMS, DINNING AREA 3/29/23 Kitchen area not ready
In-wall Inspection Passed 3/30/2023 03/30/2023
Alternate Protection Systems Inspection Not Ready 3/30/2023 03/30/2023
Alternate Protection Systems Inspection Passed 3/31/2023 03/31/2023
Alarm Test Passed 3/31/2023 03/31/2023
Occupancy Inspection - Codes Commercial Failed 4/5/2023 4/5/2023 04/05/2023
Misc
Corrective Action Required
04/05/2023
**OK TO STOCK ONLY-DO NOT OCCUPY -Provide min air gap at all appliance drains -Provide ASSE 1022 backflow device for carbonated beverage dispenser -Install grab bars at restrooms to be code compliant -Relocate toilet in women's room to be within 16"-18" from side wall -Provide water resistant finish in restrooms at painted walls -Locate restroom mirrors to be max 40" to reflective surface -Paint all exterior gas lines -Remove trash and debris from rooftop -Secure rooftop electrical whips -Label separate gas services -Upload health department approval to portal -Update permit with new contractor information -Locate sewer tracer box at grade -Locate exterior clean outs at grade -Complete corrections for all other departments
Occupancy Inspection - Fire Failed 4/5/2023 04/05/2023
Corrective Action Required
04/05/2023
Move sign for K class fire extinguisher. Duck detection did not operate properly.
Occupancy Inspection - Codes Commercial Failed 4/10/2023 4/10/2023 04/10/2023
Misc
Corrective Action Required
04/05/2023
**OK TO STOCK ONLY-DO NOT OCCUPY -Provide ASSE 1022 backflow device for carbonated beverage dispenser -Paint all exterior gas lines -Label separate gas services -Locate exterior clean outs at grade -Complete corrections for all other departments
Occupancy Inspection - Engineering Passed 4/11/2023 4/11/2023 04/11/2023
Misc
Informational
04/11/2023
4-11-23 DP. Punch list items complete, Passed.
Occupancy Inspection - Codes Commercial Full C of O 4/12/2023 4/12/2023 04/12/2023
Misc
Resolved
04/12/2023
**OK TO STOCK ONLY-DO NOT OCCUPY -Complete emergency egress lighting
Documents & Images
Date Uploaded File Type Document Name
06/14/2022 Application Form Commercial Permit Application CAVA Lee's Summit
06/15/2022 Plans CAV070 Lee's Summit Permit Drawings
06/15/2022 Specifications NRO_Specbook
06/15/2022 Engineer Report/Study Mechanical and Lighting Compliance Report
06/15/2022 Email patio direction from Hector
06/28/2022 Letter DS P/R Corrections Document
07/12/2022 Email Health Dept approval
07/21/2022 Letter Fire Building Plan Review
07/22/2022 Plans CAV070 Lee's Summit Revision 1
07/22/2022 Letter 07_22_22_Response Letter
07/22/2022 Engineer Report/Study SOWP Lot 9 - Submittal 1 - Sanitary Sewer & Storm Sewer Shop Drawings
07/29/2022 Letter DS P/R Corrections Document
08/02/2022 Letter Fire Building Plan Review
08/08/2022 Email fence info from planning
08/08/2022 Plans CAVA Lee's Summit Revision 2_2022_08_08
08/08/2022 Letter 08_08_22_Response Letter Revision 2
08/08/2022 Plans approved - CAVA Lee's Summit Revision 2_2022_08_08
09/30/2022 Plans 2022_09_27 CAVA Lee's Summit Permit Set
09/30/2022 Letter 2022_09_15 Rev3 narrative
10/06/2022 Letter Fire Building Plan Review
10/07/2022 Approved Plans approved - 2022_09_27 CAVA Lee's Summit Permit Set
11/23/2022 Letter License Tax Bill
12/01/2022 Receipt Receipt for transaction:2022-009205
12/05/2022 Letter DS Building Permit
12/14/2022 Letter INSPECTION SUMMARY
01/06/2023 Letter INSPECTION SUMMARY
01/23/2023 Letter INSPECTION SUMMARY
01/25/2023 Letter INSPECTION SUMMARY
01/26/2023 Letter INSPECTION SUMMARY
02/17/2023 Cava Data Sheet Jan 2023 Submittal
02/17/2023 CAVA FA Signed Prints JAN 2023
02/17/2023 Letter Fire (Alarm) Plan Review Notice
02/21/2023 Email temporary Tap Box - emails
03/24/2023 Letter INSPECTION SUMMARY
03/24/2023 Letter INSPECTION SUMMARY
03/24/2023 Letter INSPECTION SUMMARY
03/24/2023 Letter INSPECTION SUMMARY
03/29/2023 Letter INSPECTION SUMMARY
03/30/2023 Letter INSPECTION SUMMARY
03/30/2023 Letter INSPECTION SUMMARY
03/30/2023 Letter INSPECTION SUMMARY
03/31/2023 Letter Fire Loss Reduction Form
03/31/2023 Letter Fire Loss Reduction Form
04/03/2023 Receipt Receipt for transaction:2023-001849
04/05/2023 Letter INSPECTION SUMMARY
04/05/2023 Letter Fire Loss Reduction Form
04/06/2023 CAVA health document 4-6-2023
04/10/2023 Letter INSPECTION SUMMARY
04/11/2023 Letter INSPECTION SUMMARY
04/12/2023 Letter Codes Final Certificate of Occupancy
04/12/2023 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home