Summary
PRCOM20191295
Building Permit - Commercial
Certificate of Occupancy
C2S LLC
CHANGE OF TENANT
TENANT FINISH FOR HAIR SALON *invite planner to final to verify screening and accessible route from parking
05/20/2019
06/11/2019
11/20/2019
11/11/2021
Locations
Contacts
C2S LLC, Address:807 SW OLDHAM PKWY  
TEAM CONSTRUCTION , Address:6920 W 82ND ST, Phone:(913) 469-9990  
DEATON MARK R & LISA M, Address:4409 SE SECRETARIAT DR  
MARTIN MECHANICAL INC, Address:11632 GRANDVIEW RD, Phone:(816) 842-2900  
CROWN ELECTRICAL SERVICES, Address:1213 SE 11TH TER, Phone:(816) 272-5379  
STINE-NICHOLS PLUMBING INC, Address:318 E 16TH AVE, Phone:(816) 348-3481  
Reviews
Review Type Outcome Est. Completion Date Completed
Fire Plan Review Approved with Conditions 06/11/2019 06/10/2019
Michael Weissenbach
Address numbers required
Corrective Action Required
06/04/2019

2018 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). ACTION REQUIRED(verified at inspection) Numeric address (807) shall be readable from the address roadway (Oldham Parkway)
Portable fire extinguishers - conspicuous locations
Corrective Action Required
06/04/2019

2018 IFC 906.5- Conspicuous location. Portable fire extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. ACTION REQUIRED:(verified at inspection) Provide a minimum of one 2A-10BC fire extinguisher (5 pound) for the first floor salon/spa area and one 2A-10BC fire extinguisher (5 pound) for the basement area. Extinguishers are to be mounted on a wall or extinguisher cabinet on a normal path of travel close to an exit.
Door operations
Corrective Action Required
06/04/2019

2018 IFC 1010.1.9 Door operations. Except as specifically permitted by this section, egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. ACTION REQUIRED:(verified at inspection) NO keyed cylinder locks on the egress side (interior) on an exit.
Illumination required
Corrective Action Required
06/04/2019

2018 IFC 1008.1 Illumination required. The means of egress, shall be illuminated at all times the building space served by the means of egress is occupied. ACTION REQUIRED: (Verify at inspection) Provide emergency lighting for the exterior stairways, ADA ramp and the interior stairway to the basement.
Building Plan Review Approved with Conditions 06/11/2019 06/05/2019
Joe Frogge
License Tax Application
Corrective Action Required
06/04/2019

A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit. Action required: Comment is for informational purposes. 6/5/19 - acknowledged in letter
Accessibility - Dining surface height 902.4
Resolved
06/05/2019

ICC A117.1-2009 Section 902.4 Height. The tops of dining surfaces and work surfaces shall be 28 inches minimum and 34 inches maximum in height above the floor. Action required: Break room sink to be maximum 34"aff
Miscellaneous Correction
Resolved
06/05/2019

2018 IBC 1103.1 (Accessibility) Where required. Sites, buildings, structures, facilities, elements and spaces, temporary or permanent, shall be accessible to persons with physical disabilities. Action required: Hardware at sliding doors must be accessible type in both open and closed positions.
Plumb - Minimum number of fixtures 403.1
Resolved
06/05/2019

2012 IPC 403.1 – Minimum number of fixtures. Plumbing fixtures shall be provided for the type of occupancy and in the minimum number shown in Table 403.1. types of occupancies not shown in Table 403.1 shall be considered individually by the code official. The number of occupants shall be determined by the International Building Code. Occupancy classification shall be determined in accordance with the International Building Code. Action required: Provide mop sink.
Accessibility - Turning space 603.2.1
Resolved
06/05/2019

ICC A117.1-2017 Section 304.3 Size. Turning spaces shall comply with Section 304.3.1 or 304.3.2. 304.3.1 Circular Space. 304.3.1.1 New Buildings and facilities. In new buildings and facilities, the turning space shall be a circular space with a 67-inch minimum diameter. (see code for information regarding allowed overlapping) Action required: Provide minimum 67" diameter turning spaces at restroom and color station.
Accessibility - Fixed sidewall grab bars 604.5.1
Resolved
06/05/2019

ICC A117.1-2017 604.5.1 – Fixed side wall grab bars. Fixed side-wall grab bars shall be 42 inches minimum in length, located 12 inches maximum from the rear wall and extending 54 inches minimum from the rear wall. In addition, a vertical grab bar 18 inches minimum in length shall be mounted with the bottom of the bar located 39 inches minimum and 41 inches maximum above the floor, and with the center line of the bar located 39 inches minimum and 41 inches maximum from the rear wall. Action required: Provide vertical side wall grab bar.
Screening - Ground mounted equipment
Corrective Action Required
06/04/2019

Unified Development Ordinance Article 8, Section 8.180.F Ground mounted equipment – Ground mounted equipment shall be totally screened from view by landscaping or masonry wall up to a height of the units to be screened. Action required: Make needed corrections to drawings that provide details as to how mechanical equipment will be screened from all 4 sides per referenced UDO section. 6/5/19 - acknowledged in letter - to be field verified.
Miscellaneous Correction
Resolved
06/05/2019

2018 IPC 305.4 Freezing. Water, soil, and waste pipes shall not be installed outside of a building, in attics or crawl spaces, concealed in outside walls, or in any other place subjected to freezing temperatures unless adequate provision is made to protect such pipes from freezing by insulation or heat or both. Exterior water supply system piping shall be installed not less than 6” below the frost line (42” below grade) and not less than 12 inches below grade. Action required: Re-route water piping currently shown to be in exterior walls.
Miscellaneous Correction
Resolved
06/05/2019

2018 IBC 1104.3 Connected spaces. When a building or portion of a building is required to be accessible, at least one accessible route shall be provided to each portion of the building, to accessible building entrances connecting accessible pedestrian walkways and the public way. (see code for exceptions) Action required: Provide verification that a smooth, level path is provided from HC parking to entry. (topography of site shows a considerable slope)
Licensed Contractors Approved 06/04/2019 06/05/2019
Joe Frogge
LC - MEP Subs
Resolved
06/05/2019

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors.
Building Plan Review Rejected 05/31/2019 05/24/2019
Joe Frogge
Final Development Plan
Resolved
05/28/2019

The building permit for this project can not be issued until the Codes Administration Department has received the approved Final Development Plan from the Planning and Development Department.
License Tax Application
Corrective Action Required
05/24/2019

A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit. Action required: Comment is for informational purposes.
Accessibility - Dining surface height 902.4
Corrective Action Required
05/24/2019

ICC A117.1-2009 Section 902.4 Height. The tops of dining surfaces and work surfaces shall be 28 inches minimum and 34 inches maximum in height above the floor. Action required: Break room sink to be maximum 34"aff
Miscellaneous Correction
Corrective Action Required
05/24/2019

2018 IBC 1103.1 (Accessibility) Where required. Sites, buildings, structures, facilities, elements and spaces, temporary or permanent, shall be accessible to persons with physical disabilities. Action required: Hardware at sliding doors must be accessible type in both open and closed positions.
Plumb - Minimum number of fixtures 403.1
Corrective Action Required
05/24/2019

2012 IPC 403.1 – Minimum number of fixtures. Plumbing fixtures shall be provided for the type of occupancy and in the minimum number shown in Table 403.1. types of occupancies not shown in Table 403.1 shall be considered individually by the code official. The number of occupants shall be determined by the International Building Code. Occupancy classification shall be determined in accordance with the International Building Code. Action required: Provide mop sink.
Accessibility - Turning space 603.2.1
Corrective Action Required
05/24/2019

ICC A117.1-2017 Section 304.3 Size. Turning spaces shall comply with Section 304.3.1 or 304.3.2. 304.3.1 Circular Space. 304.3.1.1 New Buildings and facilities. In new buildings and facilities, the turning space shall be a circular space with a 67-inch minimum diameter. (see code for information regarding allowed overlapping) Action required: Provide minimum 67" diameter turning spaces at restroom and color station.
Accessibility - Fixed sidewall grab bars 604.5.1
Corrective Action Required
05/24/2019

ICC A117.1-2017 604.5.1 – Fixed side wall grab bars. Fixed side-wall grab bars shall be 42 inches minimum in length, located 12 inches maximum from the rear wall and extending 54 inches minimum from the rear wall. In addition, a vertical grab bar 18 inches minimum in length shall be mounted with the bottom of the bar located 39 inches minimum and 41 inches maximum above the floor, and with the center line of the bar located 39 inches minimum and 41 inches maximum from the rear wall. Action required: Provide vertical side wall grab bar.
Screening - Ground mounted equipment
Corrective Action Required
05/24/2019

Unified Development Ordinance Article 8, Section 8.180.F Ground mounted equipment – Ground mounted equipment shall be totally screened from view by landscaping or masonry wall up to a height of the units to be screened. Action required: Make needed corrections to drawings that provide details as to how mechanical equipment will be screened from all 4 sides per referenced UDO section.
Miscellaneous Correction
Corrective Action Required
05/24/2019

2018 IPC 305.4 Freezing. Water, soil, and waste pipes shall not be installed outside of a building, in attics or crawl spaces, concealed in outside walls, or in any other place subjected to freezing temperatures unless adequate provision is made to protect such pipes from freezing by insulation or heat or both. Exterior water supply system piping shall be installed not less than 6” below the frost line (42” below grade) and not less than 12 inches below grade. Action required: Re-route water piping currently shown to be in exterior walls.
Miscellaneous Correction
Corrective Action Required
05/24/2019

2018 IBC 1104.3 Connected spaces. When a building or portion of a building is required to be accessible, at least one accessible route shall be provided to each portion of the building, to accessible building entrances connecting accessible pedestrian walkways and the public way. (see code for exceptions) Action required: Provide verification that a smooth, level path is provided from HC parking to entry. (topography of site shows a considerable slope)
Licensed Contractors Rejected 05/31/2019 05/24/2019
Joe Frogge
LC - MEP Subs
Corrective Action Required
05/24/2019

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors.
Fire Plan Review Rejected 05/31/2019 05/22/2019
Joe Dir
Address numbers required
Corrective Action Required
05/22/2019

2018 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). ACTION REQUIRED(verified at inspection) Numeric address (807) shall be readable from the address roadway (Oldham Parkway)
Portable fire extinguishers - conspicuous locations
Corrective Action Required
05/22/2019

2018 IFC 906.5- Conspicuous location. Portable fire extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. ACTION REQUIRED:(verified at inspection) Provide a minimum of one 2A-10BC fire extinguisher (5 pound) for the first floor salon/spa area and one 2A-10BC fire extinguisher (5 pound) for the basement area. Extinguishers are to be mounted on a wall or extinguisher cabinet on a normal path of travel close to an exit.
Door operations
Corrective Action Required
05/22/2019

2018 IFC 1010.1.9 Door operations. Except as specifically permitted by this section, egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. ACTION REQUIRED:(verified at inspection) NO keyed cylinder locks on the egress side (interior) on an exit.
Illumination required
Corrective Action Required
05/22/2019

2018 IFC 1008.1 Illumination required. The means of egress, shall be illuminated at all times the building space served by the means of egress is occupied. ACTION REQUIRED: Provide emergency lighting for the exterior stairways, ADA ramp and the interior stairway to the basement.
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for Change of Tenant $320.00 $320.00 Paid 06/11/2019
8331507-Sewer Connection Fee $300.00 $300.00 Paid 06/11/2019
Commercial Excise Tax Fee $1,297.50 $1,297.50 Paid 05/21/2019
$1,297.50
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Miscellaneous Inspection Partial 11/7/2019 11/07/2019
Informational
11/07/2019
met with contractor and discussed project
Miscellaneous Inspection Partial 8/20/2020 8/20/2020 08/20/2020
Miscellaneous Correction
Informational
08/20/2020
-Met with the owners to discuss the progress of the project and extension of the permit since no inspections have been performed after 180 days. Work has resumed and on track for all rough inspection. The owners stated that the expect the project completion to be around 10-1-20.
Rough Plumbing Inspection - Commercial Failed 9/24/2020 9/24/2020 09/24/2020
Misc
Corrective Action Required
09/24/2020
-Gas pressure test failed, must hold minimum 10 psi for 15 minutes -Connect gas piping to appliance
Gas Piping Inspection - Commercial Passed 9/25/2020 9/25/2020 09/25/2020
Gas Service Inspection - Commercial Passed 12/14/2020 12/14/2020 09/25/2020
All Rough Inspection - Commercial Failed 10/21/2020 10/21/2020
Misc
Corrective Action Required
10/21/2020
PLUMBING -water heater T&P valves to discharge to Impervious floor surface and within 6” of floor -remove drain pipe for improper drainage of appliances -Provide backflow certification -improper use of sanitary-t’s at shampoo station bowl drainage, provide Y combo fittings -midpoint support for a vertical DWV 2” & smaller MECHANICAL -Ductwork violating panel working space -HVAC condensation to drain to impervious floor -seal penetrations in stud cavities used as return plenum ELECTRICAL -violation of working space at panel. Minimum 30” wide and 36” deep.The work space shall be clear and extend from the floor to 6.5’ vertically. -MC conductor above ceiling needs terminated GENERAL -fireblock all top and bottom plate penetrations -submit documents for approval pertaining to anticipated field changes
Rough Plumbing Inspection - Commercial Partial 10/21/2020 10/21/2020 10/21/2020
Misc
Resolved
10/21/2020
-Gas pressure test failed, must hold minimum 10 psi for 15 minutes -Connect gas piping to appliance
Misc
Informational
10/21/2020
Gas piping & pressure test approved
All Rough Inspection - Commercial Passed 12/14/2020 12/14/2020 12/14/2020
Misc
Resolved
12/14/2020
PLUMBING -water heater T&P valves to discharge to Impervious floor surface and within 6” of floor -remove drain pipe for improper drainage of appliances -Provide backflow certification -improper use of sanitary-t’s at shampoo station bowl drainage, provide Y combo fittings -midpoint support for a vertical DWV 2” & smaller MECHANICAL -Ductwork violating panel working space -HVAC condensation to drain to impervious floor -seal penetrations in stud cavities used as return plenum ELECTRICAL -violation of working space at panel. Minimum 30” wide and 36” deep.The work space shall be clear and extend from the floor to 6.5’ vertically. -MC conductor above ceiling needs terminated GENERAL -fireblock all top and bottom plate penetrations -submit documents for approval pertaining to anticipated field changes
Occupancy Inspection - Codes Commercial Failed 8/19/2021 8/19/2021 08/19/2021
Misc
Corrective Action Required
08/19/2021
EXTERIOR: - Front steps at landing : over 7", top over 8". - 2 steps from landing to parking lot are over max, and over 3/8". -Ramp to parking lot requires hand/guard, see 405,406 ANSI 117.1. - Provide detailed plans on front deck, landing and cantilevered area. Provide enginee's corrections and fix to no compliant framing. -Handrails & guards do not meet code. - Plan shows 6x6 post, 4x4's installed. -connection to existing deck at NE corner. - connection of new deck to existing cantilever. -front steps to exisitng deck: over 7", top step over 8". - deck piers plans shows 12" , no pier inspection provided. -seal all exterior penetrations . -paint or repair all pealing paint and siding. -removed all trash , debris, dirt, asphalt. REAR EXIT- rear deck and stairs existing: Provide min 42" guard at rear deck. -guard has openings over 4". repair where needed. INTERIOR: Provide anit syphon on basment hose bib. -provide backflow report. -open blanks at electrical panel. - remove exit sign from rear door 1st floor. - install guard to open side of basment stairs - install handrail on west side of stairs to basement. -restroom sign. -provide ADA mirror at max 40" AFF> -Outlet at NE sink needs to be GFCI -outlet at washer needs to be gfci, within 6'.
Misc
Corrective Action Required
08/19/2021
FD- install fire extinguishers. Planning- scheudle for Planning inspector to be on site. Water DEPT- provide backflow report. Parking lot needs addressed for required : Parking spaces, handicap signage and space, top coat or surface. Repair as required on permit.
Occupancy Inspection - Fire Passed 8/19/2021 8/19/2021 08/19/2021
Informational
08/19/2021
Final was appropriate with no life safety violations noted.
Rough Plumbing Inspection - Commercial Passed 10/21/2020 08/23/2021
Misc
Informational
10/21/2020
Gas piping & pressure test approved
Occupancy Inspection - Planning Failed 08/25/2021
Corrective Action Required
08/25/2021
PARKING LOT. - The existing parking lot is in major disrepair and requires reconstruction. - A minimum of 7 parking spaces are required to be striped to serve the building. At least one of the 7 parking spaces shall be an ADA van-accessible space with adjacent access aisle. - See UDO Section 8.260 for the City's parking lot design (construction) standards.
Corrective Action Required
08/25/2021
MECHANICAL SCREENING. The new ground-mounted equipment at the south building is screened by a wooden enclosure. City ordinance only allows the screening of ground-mounted mechanical equipment by the use of evergreen landscaping or masonry walls; the wooden enclosure screen does not comply with City ordinance.
Occupancy Inspection - Planning Temporary C of O 09/30/2021
Corrective Action Required
09/30/2021
PARKING LOT. A minimum of 7 parking spaces are required to be striped to serve the building. At least one of the 7 parking spaces shall be an ADA van-accessible space with adjacent access aisle. Existing parking lot will be resurfaced and re-striped prior to final occupancy.
Occupancy Inspection - Codes Commercial Failed 9/30/2021 9/30/2021 09/30/2021
Misc
Corrective Action Required
08/19/2021
Planning, fire, water FEI, is good for TCO, Parking lot date set for 10/24 Complete the below for TCO- EXTERIOR: - 2 steps from landing to parking lot are over max, and over 3/8". -Ramp to parking lot requires hand/guard, see 405,406 ANSI 117.1. - Provide detailed plans on front deck, landing and cantilevered area. Provide enginee's corrections and fix to no compliant framing. - Plan shows 6x6 post, 4x4's installed. -connection to existing deck at NE corner. - connection of new deck to existing cantilever.
Misc
Resolved
09/30/2021
Planning-sod Parking spaces, handicap signage and space, top coat or surface. Repair as required on permit.
Occupancy Inspection - Planning Passed 11/11/2021 11/11/2021
Occupancy Inspection - Codes Commercial Full C of O 11/11/2021 11/11/2021 11/11/2021
Misc
Resolved
11/11/2021
Complete the below for TCO- EXTERIOR: - 2 steps from landing to parking lot are over max, and over 3/8". -Ramp to parking lot requires hand/guard, see 405,406 ANSI 117.1. - Provide detailed plans on front deck, landing and cantilevered area. Provide enginee's corrections and fix to no compliant framing. - Plan shows 6x6 post, 4x4's installed. -connection to existing deck at NE corner. - connection of new deck to existing cantilever.
Documents & Images
Date Uploaded File Type Document Name
05/21/2019 Letter License Tax Bill
05/22/2019 Letter Fire Building Plan Review
05/24/2019 Letter DS P/R Corrections Document
06/10/2019 Letter Fire Building Plan Review
06/11/2019 Letter Codes Plan Review Conditions
06/11/2019 Receipt Receipt for transaction: 2019-003563
06/11/2019 Letter Codes Building Permit
11/07/2019 Letter INSPECTION SUMMARY
08/18/2020 Letter Codes 180 Day Letter
08/18/2020 Letter Codes 180 Day Letter
08/18/2020 Letter Codes 180 Day Letter
08/18/2020 Letter Codes 180 Day Letter
08/18/2020 Letter Codes 180 Day Letter
08/18/2020 Letter Codes 180 Day Letter
08/20/2020 Letter INSPECTION SUMMARY
08/20/2020 Letter DS Building Permit
08/20/2020 Letter Fire Building Plan Review
09/24/2020 Letter INSPECTION SUMMARY
09/25/2020 Letter INSPECTION SUMMARY
09/25/2020 Letter INSPECTION SUMMARY
10/21/2020 Letter INSPECTION SUMMARY
10/21/2020 Letter INSPECTION SUMMARY
10/21/2020 Letter INSPECTION SUMMARY
11/13/2020 Approved Plans approved - 20_1113 Rev 3+A7-1 Supp Dwg - The Social Salon and Spa
11/13/2020 Approved Plans approved - 20_1113 Rev 3_A7 Dwg The Social Salon and Spa.35
12/14/2020 Letter INSPECTION SUMMARY
08/19/2021 Letter INSPECTION SUMMARY
08/19/2021 Letter Fire Loss Reduction Form
08/23/2021 Letter INSPECTION SUMMARY
08/24/2021 Backflow Inspection report - The Social Salon and Spa 102020
08/24/2021 IMG_6139
08/24/2021 IMG_6138
08/24/2021 IMG_6141
08/24/2021 IMG_6137
08/24/2021 IMG_6133
08/25/2021 Letter INSPECTION SUMMARY
09/30/2021 Letter INSPECTION SUMMARY
10/06/2021 Letter INSPECTION SUMMARY
10/25/2021 Engineer Report/Study 21_1025 Social salon Engineer report - ADA ramp
11/11/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home