Planning Application Status

PL2023161




 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PL2023161
Pergola Park, Lots 118B1, 112A1 and 109A
Minor Plat
Minor Plat
Recorded
06/22/2023
DUNN KEVIN W & ERIN E
Locations
Contacts
DUNN KEVIN W & ERIN E, Address:3207 SW PERGOLA PARK DR  
RUSSELL PEARSON, Address:3152 GRANDSTAND CIR, Phone:(913) 735-9861  
Aaron Reuter, Address:Schlagel Associates, Phone:(913) 322-7158  
Reviews
Review Type Outcome Est. Completion Date Completed
Engineering Review No Comments 09/14/2023 09/13/2023
Sue Pyles, P.E.
Planning Review Approved with Conditions 09/14/2023 09/13/2023
Hector Soto Jr.
Corrective Action Required
09/13/2023

ACCESS EASEMENT. Add a note to the plat referencing that an access easement will be granted from Lot 118A to Lot 118 B1 by separate document.
GIS Review No Comments 09/14/2023 09/12/2023
Kathy Kraemer
Engineering Review Corrections 07/17/2023 07/14/2023
Sue Pyles, P.E.
Corrective Action Required
07/14/2023

Include the following Drainage Note: Individual lot owner(s) shall not change or obstruct the drainage flow lines on the lots included in the Master Drainage Plan, unless specific application is made and approved by the City Engineer.
GIS Review Corrections 07/17/2023 07/12/2023
Kathy Kraemer
Corrective Action Required
07/12/2023

There are several previous plats that list curve data like ITBs. Are these standard curves or tangent curves? Please label all ITBs on standard curves and in traverse order, especially near coordinates 17-20.
Corrective Action Required
07/12/2023

It looks like there is a lot line separating lot 118B1 into 2 lots; near coordinate 13 (19 ft). Either make one a new lot number, or remove the line for clarity.
Corrective Action Required
07/12/2023

It is possible that there will be more comments after plat resubmittal (removing the 1ft strip).
Planning Review Corrections 07/17/2023 07/11/2023
Hector Soto Jr.
Corrective Action Required
07/11/2023

GENERAL. What is the purpose of maintaining a 1' wide strip between Lot 112A1 and Lot 118A to the south and west? It serves no practical purpose to keep this narrow of a strip. No mowing or other maintenance equipment can be used within the cofines of a 1' strip without having to encroach on adjacent private property. As such, this 1' strip should be absorbed into the proposed Lot 112A1 or the adjacent Lot 118A as part of a final plat.
Corrective Action Required
07/11/2023

STREETS. Label the right-of-way width for SW Pergola Park Dr.
Corrective Action Required
07/11/2023

SIDEWALKS. Show and label the required 5' sidewalks along the frontage of the subject lots.
Corrective Action Required
07/11/2023

ACCESS EASEMENT. The access easement dedication paragraph shall be updated to reflect the new lot number label.
Corrective Action Required
07/11/2023

CITY SIGNATURE BLOCK. Update the name of the Director of Development Services with that of Joshua Johnson, AICP.
Corrective Action Required
07/11/2023

PROPERTY BOUNDARY DIMENSIONS. - Label the property line curve length for the segment between (State Plane Coordinate) Point #11 and the western property line for Lot 112A1. - Label the property line curve length for the segment between (State Plane Coordinate) Point #17 and the eastern property line for Lot 109A.
Fees
Paid Fees Amount Paid Owing Date Paid
9110077-Minor Plat fee $725.00 $725.00 Paid 09/13/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Hearings
Title Location Date Time
Documents & Images
Date Uploaded File Type Document Name
06/30/2023 Application Form Document_2023-06-29_181249
06/30/2023 Plans 2023_06_22-23-136 F MINOR 118 109 112-Plat-24x36
07/14/2023 Letter Applicant Letter - MP (DRCL)
09/07/2023 Letter 23-136 Access Easement
09/07/2023 Plans 2023_08_24-23-136 F MINOR 118 109 112-Plat-24x36
09/13/2023 Receipt Receipt for transaction:2023-007028
09/13/2023 Letter Applicant Letter - MP (DRCL)
11/09/2023 Plans Pergola Park Lots 118B1, 112A1,& 109A_Recorded Plat
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New license, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home