Review Type |
Outcome |
Est. Completion Date |
Completed |
Traffic Review
|
Approved with Conditions
|
09/10/2020
|
09/10/2020
|
|
Michael Park
|
|
Approval requires condition of vacation of right-of-way (ROW); similar to completed ROW vacation on the east side of Longview Blvd., especially pertaining to the slip lane/parking along the west side of Longview Blvd., Sensation Drive and Tower Park Drive.
|
|
|
Planning Review
|
Approved with Conditions
|
09/10/2020
|
09/09/2020
|
|
Victoria Nelson
|
|
Miscellaneous Correction
Corrective Action Required
Title. Please re-label the title from Final Development Plan to Preliminary Development Plan.
|
|
Miscellaneous Correction
Corrective Action Required
Oil and Gas Wells. Please state whether or not there are active, inactive, or capped wells within the area. Refer to DNR Well Database and reference the site.
|
|
Miscellaneous Correction
Corrective Action Required
Trash Enclosure. Please show a detailed drawing of enclosure, screening methods and required concrete slab. Please see Article 8, Section 8.180.G and 8.260. F. c in the UDO.
|
|
Miscellaneous Correction
Corrective Action Required
Monument sign. Are there plans of installing a monument sign?
|
|
Miscellaneous Correction
Corrective Action Required
Parking. Our UDO requires 4/1000 for general office use, and 5/1000 for any retail and medical office. You show on the site plan a veterinary clinic and retail, but yet you are only showing 2.5/1000. Please provide justification and documentation stating why your numbers are less then what our UDO is requires. Parking requirements can be found in the UDO under Article 8, Section 8.530.
|
|
Legal Description
Corrective Action Required
Please submit an electronic copy of the legal description in Microsoft Word document. The legal description can be emailed to the planner's email address above.
|
|
Miscellaneous Correction
Corrective Action Required
Parking. Under the proposed parking please finish breaking up the parking count. You started this with saying 18 along street frontage and 2 handicap.
|
|
Miscellaneous Correction
Corrective Action Required
Handicap accessible parking. Please show if there will be additional handicap parking and where the signs will be located.
|
|
Miscellaneous Correction
Corrective Action Required
Trash enclosure. Please refer to UDO Section 8.620.F.1.c for the trash enclosure requirements that still need to be met,
30' measurment and the type of concrete that is required.
|
|
|
Engineering Review
|
Approved with Conditions
|
09/10/2020
|
09/09/2020
|
|
Sue Pyles, P.E.
|
|
DE C&O #01 Eng Plans – FDP/PDP
Corrective Action Required
All required engineering plans and studies, including water lines, sanitary sewers, storm drainage, streets and erosion and sediment control shall be submitted along with the final development plan. All public infrastructure must be substantially complete, prior to the issuance of any certificates of occupancy.
|
|
DE C&O #03 Eng & Insp Fees
Corrective Action Required
All Engineering Plan Review and Inspection Fees shall be paid prior to approval of the associated engineering plans and prior to the issuance of any infrastructure permits or the start of construction (excluding land disturbance permit).
|
|
DE C&O #06 Land Disturbance
Corrective Action Required
A Land Disturbance Permit shall be obtained from the City if ground breaking will take place prior to the issuance of an infrastructure permit, building permit, or prior to the approval of the Final Development Plan / Engineering Plans.
|
|
DE C&O #09 FDP Reviews
Corrective Action Required
Certain aspects of the development plan will be further reviewed during the Final Development Plan phase of the project. This includes detailed aspects of the design to help ensure that the plan meets the design criteria and specifications contained in the Design and Construction Manual.
|
|
DE C&O #11 Pavement Thickness
Corrective Action Required
Private parking lots shall follow Article 8 of the Unified Development Ordinance for pavement thickness and base requirements.
|
|
|
Fire Review
|
Approved with Conditions
|
09/10/2020
|
09/04/2020
|
|
Jim Eden
|
|
Code Statement
All issues pertaining to life safety and property protection from the hazards of fire, explosion or dangerous conditions in new and existing buildings, structures and premises, and to the safety to fire fighters and emergency responders during emergency operations, shall be in accordance with the 2018 International Fire Code.
FYI- The use of the individual spaces may require additional fire protection, including an automatic fire sprinkler system.
|
|
|
Planning Review
|
Corrections
|
08/21/2020
|
08/21/2020
|
|
Victoria Nelson
|
|
Miscellaneous Correction
Corrective Action Required
Title. Please re-label the title from Final Development Plan to Preliminary Development Plan.
|
|
Miscellaneous Correction
Corrective Action Required
Oil and Gas Wells. Please state whether or not there are active, inactive, or capped wells within the area. Refer to DNR Well Database and reference the site.
|
|
Miscellaneous Correction
Corrective Action Required
Trash Enclosure. Please show a detailed drawing of enclosure, screening methods and required concrete slab. Please see Article 8, Section 8.180.G and 8.260. F. c in the UDO.
|
|
Miscellaneous Correction
Corrective Action Required
Monument sign. Are there plans of installing a monument sign?
|
|
Miscellaneous Correction
Corrective Action Required
Parking. Our UDO requires 4/1000 for general office use, and 5/1000 for any retail and medical office. You show on the site plan a veterinary clinic and retail, but yet you are only showing 2.5/1000. Please provide justification and documentation stating why your numbers are less then what our UDO is requires. Parking requirements can be found in the UDO under Article 8, Section 8.530.
|
|
Legal Description
Corrective Action Required
Please submit an electronic copy of the legal description in Microsoft Word document. The legal description can be emailed to the planner's email address above.
|
|
Miscellaneous Correction
Corrective Action Required
Parking. Under the proposed parking please finish breaking up the parking count. You started this with saying 18 along street frontage and 2 handicap.
|
|
Miscellaneous Correction
Corrective Action Required
Handicap accessible parking. Please show if there will be additional handicap parking and where the signs will be located.
|
|
|
Fire Review
|
Approved with Conditions
|
08/21/2020
|
08/21/2020
|
|
Jim Eden
|
|
Code Statement
Corrective Action Required
All issues pertaining to life safety and property protection from the hazards of fire, explosion or dangerous conditions in new and existing buildings, structures and premises, and to the safety to fire fighters and emergency responders during emergency operations, shall be in accordance with the 2018 International Fire Code.
|
|
|
Engineering Review
|
Corrections
|
08/21/2020
|
08/20/2020
|
|
Sue Pyles, P.E.
|
|
Corrective Action Required
Please note that City design standards for public sidewalk include a maximum cross slope of 1.5%. Please revise or clarify the sidewalk slope note on Sheet C2.0 accordingly.
|
|
Corrective Action Required
Storm sewer profiles are not required for a Preliminary Development Plan. When included with the Final development Plan, please make sure there is a minimum 0.5' drop through MH 105 and that the design HGL is shown.
|
|
Corrective Action Required
Erosion control and standard details are not reqired with a Preliminary Development Plan and have not been reviewed.
|
|
|
Traffic Review
|
Approved with Conditions
|
08/21/2020
|
08/18/2020
|
|
Michael Park
|
|
Corrective Action Required
Approval requires condition of vacation of right-of-way (ROW); similar to completed ROW vacation on the east side of Longview Blvd., especially pertaining to the slip lane/parking along the west side of Longview Blvd., Sensation Drive and Tower Park Drive.
|
|
|