Review Type |
Outcome |
Est. Completion Date |
Completed |
Engineering Review - Sanitary
|
Corrections
|
01/29/2025
|
01/29/2025
|
|
Susan Nelson, P.E.
|
|
Miscellaneous Correction
Corrective Action Required
Submit an Engineer's Estimate of Probable Construction Costs.
|
|
|
Engineering Review - Sanitary
|
Corrections
|
01/14/2025
|
01/09/2025
|
|
Susan Nelson, P.E.
|
|
Miscellaneous Correction
Corrective Action Required
Verify that adequate drop (0.5’) is provided through Sanitary Manhole (19).
|
|
|
Engineering Review - Sanitary
|
Corrections
|
05/17/2024
|
05/16/2024
|
|
Susan Nelson, P.E.
|
|
Miscellaneous Correction
Corrective Action Required
Please submit the plat for review of the sanitary sewer easement. Note that the plat must be approved prior to issuance of any permit.
|
|
Miscellaneous Correction
Corrective Action Required
Show and document all existing utility easements and right-of-way limits along Hollywood Dr. and Summitcrest Dr. Update these plans with any revisions to the plat and/or the commercial final development plans.
|
|
Miscellaneous Correction
Corrective Action Required
Add the flowlines of all pipes entering and leaving the proposed sanitary manhole (19). Show adequate drop through this manhole.
|
|
Miscellaneous Correction
Corrective Action Required
Proposed sanitary manhole (19) appears to require a drop manhole (LS 6501.H.6.) Verify the design and add the City standard detail for Drop Manhole (SAN-4), if appropriate.
|
|
Miscellaneous Correction
Corrective Action Required
If only one type of work is being completed in the public plans, please title the plans more specifically, such as Public Sanitary Sewer Plans. Sheet C2-01: Note 4 and 8 are the same.
|
|
|
Engineering Review - Sanitary
|
Corrections
|
04/24/2024
|
04/23/2024
|
|
Susan Nelson, P.E.
|
|
Miscellaneous Correction
Corrective Action Required
Please submit the plat for review of the sanitary sewer easement. The proposed 15-foot wide easement does not appear to be of adequate width with the buried depth of pipe. Verify the necessary width of the easement and revise accordingly (LS 6501 L.).
|
|
Miscellaneous Correction
Corrective Action Required
Show all existing utility easements and right-of-way limits along Hollywood Dr. and Summitcrest Dr. on the plan sheets.
|
|
Miscellaneous Correction
Corrective Action Required
Add stationing to the plans to specifically identify the locations of the proposed improvements. Specifically locate the connection point to the existing sanitary sewer and identify the size of existing sanitary sewer.
|
|
Miscellaneous Correction
Corrective Action Required
Extend the sanitary sewer line into the adjacent lot an adequate distance to allow a cut-in wye service line for the adjacent lot (LS 6501 F. Building Sewer Stubs, 3. Location).
|
|
Miscellaneous Correction
Corrective Action Required
The existing sanitary manhole to the east of your connection is MH 58-021, please relabel.
|
|
Miscellaneous Correction
Corrective Action Required
Please reference LS 6501 H. Manholes, 10. Adding a manhole onto Existing Sewer Main for design specifics for adding a manhole to the existing system.
|
|
Miscellaneous Correction
Corrective Action Required
Utilize LS 6501 D. Hydraulic Design for design specifics and to add build notes to the plans.
|
|
Miscellaneous Correction
Corrective Action Required
Please include the following items in the profile view
- All sanitary sewer flowlines at all structures including adequate drop at each.
- Proposed grade.
- Pipe specifics. The pipe must be PVC (SDR-26).
- Note that states that flowable fill is required around all manhole structures.
|
|
Miscellaneous Correction
Corrective Action Required
Add Standard Details for this project to include, but not limited to, the following.
- Pipe Bedding Detail (GEN-6).
- Manhole Wall Connection detail (SAN-5).
|
|
Miscellaneous Correction
Corrective Action Required
Submit a separate Engineer's Estimate of Probable Construction Costs for this Public Sanitary Sewer plan set.
|
|
|