Permit Application Status

PRRES20252864


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20252864
Building Permit - Residential
Issued
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. UNCOVERED PATIO. ROOF TRUSSES.
07/07/2025
07/11/2025
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
BILL'S PLUMBING SERVICE LLC, Address:308 E PARK STREET, Phone:(913) 829-8213  
taylor@summithomeskc.com  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Water Tap Fee $4,080.00 $4,080.00 Paid 07/11/2025
Water Meter Fee $791.53 $791.53 Paid 07/11/2025
Sanitary Sewer Development Fee $2,398.00 $2,398.00 Paid 07/11/2025
Right of Way Permit Fee $85.00 $85.00 Paid 07/11/2025
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 07/11/2025
Valuation Fee New Single Family $1,827.40 $1,827.40 Paid 07/11/2025
Parks Impact Fee Residential Zone 2 $1,000.00 $1,000.00 Paid 07/11/2025
Outstanding Fees Amount Paid Owing Date Paid
Not Ready Inspection Fee $75.00 $0.00 $75.00 Not Paid
Not Ready Inspection Fee $75.00 $0.00 $75.00 Not Paid
Not Ready Inspection Fee $75.00 $0.00 $75.00 Not Paid


$225.00    Add Fees to My Cart
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Plot Plan Inspection Pending
Occupancy Inspection - Codes Residential Pending
Footing Inspection - Residential Pending
Misc
Corrective Action Required
09/19/2025
No address posted Erosion control not in compliance
Erosion Control Inspection Residential Pending
DCM5 ESC INSP DENIED
Corrective Action Required
09/25/2025
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. Provide gravel entrance and maintain silt fence around lot
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
09/25/2025
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Driveway Inspection Pending 1/5/2026 1/5/2026
Misc
Informational
12/17/2025
12-17-25 Dustin A, dw has been formed and compacted to city specs.
Sidewalk Inspection Pending 1/5/2026 1/5/2026
Misc
Informational
12/17/2025
12-17-25 Dustin A, sw has been formed and compacted. Contractor needed to cut part of the existing ada ramp out to get sidewalk away from storm box
Footing Inspection - Residential Failed 9/19/2025 09/19/2025
Misc
Corrective Action Required
09/19/2025
No address posted Erosion control not in compliance
Underslab Plumbing Inspection - Residential Failed 9/25/2025 9/25/2025 09/25/2025
Misc
Corrective Action Required
09/25/2025
Inspection denied -no address posted -Erosion control, not in compliance
Erosion Control Inspection Residential Failed 9/25/2025 9/25/2025 09/25/2025
DCM5 ESC INSP DENIED
Corrective Action Required
09/25/2025
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. Provide gravel entrance and maintain silt fence around lot
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
09/25/2025
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Underslab Plumbing Inspection - Residential Passed 9/26/2025 9/26/2025 09/26/2025
Misc
Resolved
09/26/2025
Inspection denied -no address posted -Erosion control, not in compliance
Sewer Service Inspection - R Passed 10/16/2025 10/16/2025 10/16/2025
Water Service Inspection - R Passed 10/17/2025 10/17/2025 10/17/2025
Gas Service Inspection - Residential Passed 11/12/2025 11/12/2025 11/12/2025
All Rough Inspection - Residential Failed 11/12/2025 11/12/2025 11/12/2025
Misc
Corrective Action Required
11/12/2025
-anchor bolts to be within the middle 1/3 of sill plate -(3) 2x6 at garage/foyer wall to plans -furr down for insulation around plumbing and hvac in garage -fireblock hvac chase to furr down and ceiling space in garage -fireblock rear garage wall into furr down(fill gaps and penetrations) -in cover covered nailing for portal frame -fireblock hvac chase in pantry into furr down -seal penetration In owners entry wall into stair landing -missing studs at LIB wall Bed 5 -uncover covered front porch -place stud pack under GT in primary closet to provide full bearing -all double and triple trusses must be nail to manufacture specifications. -protect dryer vent 2” below bottom plate as required by code -shim under beam in basement full width -provide blocking under kitchen island -missing stud pack in stairwell wall in basement
All Rough Inspection - Residential Not Ready 11/17/2025 11/17/2025 11/17/2025
Misc
Corrective Action Required
11/12/2025
MULTIPLE ITEMS NOT ADDRESS. INSPECTION STOPPED, NOT READY -anchor bolts to be within the middle 1/3 of sill plate -(3) 2x6 at garage/foyer wall to plans -furr down for insulation around plumbing and hvac in garage -fireblock hvac chase to furr down and ceiling space in garage -fireblock rear garage wall into furr down(fill gaps and penetrations) -in cover covered nailing for portal frame -fireblock hvac chase in pantry into furr down -seal penetration In owners entry wall into stair landing -missing studs at LIB wall Bed 5 -uncover covered front porch -place stud pack under GT in primary closet to provide full bearing -all double and triple trusses must be nail to manufacture specifications. -protect dryer vent 2” below bottom plate as required by code -shim under beam in basement full width -provide blocking under kitchen island -missing stud pack in stairwell wall in basement
All Rough Inspection - Residential Failed 11/19/2025 11/19/2025 11/19/2025
Misc
Corrective Action Required
11/17/2025
MULTIPLE ITEMS NOT ADDRESS. INSPECTION STOPPED, NOT READY -anchor bolts to be within the middle 1/3 of sill plate -fireblock hvac chase to furr down and ceiling space in garage -seal penetration In owners entry wall into stair landing -missing studs at LIB wall Bed 5, tighten LIB, strap should not be lose -uncover covered front porch, need to see truss screw installation -all double and triple trusses must be nail to manufacture specs -shim under beam in basement full width -provide blocking under kitchen island - protect all wiring within 6’ of attic access - fire block hvac in soffit in pantry - add strap at top plate penetration for plumbing vent at great room/bath 3 - add a 2nd strap at top plate seam in bed 2
Electrical Service Inspection Failed 11/19/2025 11/19/2025
Misc
Corrective Action Required
11/19/2025
Correct ufer clamp needed
All Rough Inspection - Residential Failed 11/25/2025 11/25/2025 11/25/2025
Misc
Corrective Action Required
11/19/2025
-fireblock hvac chase to furr down and ceiling space in garage -missing studs at LIB wall Bed 5, tighten LIB, strap should not be lose(lib requires 16” OC stud spacing) - protect all wiring within 6’ of attic access - fire block pex into pantry furr down - add strap at top plate penetration for plumbing vent at great room/bath 3 - add a 2nd strap at top plate seam in bed 2
Electrical Service Inspection Failed 11/25/2025 11/25/2025 11/25/2025
Misc
Corrective Action Required
11/19/2025
-Gas bonding clamp not installed correctly -clamp for ufer not listed for rebar
All Rough Inspection - Residential Not Ready 12/1/2025 12/1/2025 12/01/2025
Misc
Corrective Action Required
11/25/2025
-missing studs at LIB wall Bed 5, tighten LIB, strap should not be lose(lib requires 16” OC stud spacing) - fire block pex into pantry furr down - add a 2nd strap at top plate seam in bed 2
Electrical Service Inspection Passed 12/1/2025 12/1/2025 12/01/2025
Misc
Resolved
12/01/2025
-Gas bonding clamp not installed correctly -clamp for ufer not listed for rebar
All Rough Inspection - Residential Not Ready 12/3/2025 12/3/2025 12/03/2025
Misc
Corrective Action Required
12/01/2025
-missing studs at LIB wall Bed 5, tighten LIB, strap should not be lose(lib requires 16” OC stud spacing) - fire block pex into pantry furr down
All Rough Inspection - Residential Passed 12/4/2025 12/4/2025 12/04/2025
Misc
Resolved
12/04/2025
-missing studs at LIB wall Bed 5, tighten LIB, strap should not be lose(lib requires 16” OC stud spacing) - fire block pex into pantry furr down
Driveway Inspection Partial 12/17/2025 12/17/2025 12/17/2025
Misc
Informational
12/17/2025
12-17-25 Dustin A, dw has been formed and compacted to city specs.
Sidewalk Inspection Partial 12/17/2025 12/17/2025 12/17/2025
Misc
Informational
12/17/2025
12-17-25 Dustin A, sw has been formed and compacted. Contractor needed to cut part of the existing ada ramp out to get sidewalk away from storm box
Documents & Images
Date Uploaded File Type Document Name
07/07/2025 BY #0240 - PERMIT APP
07/11/2025 Approved Plans APPROVED PLANS
07/11/2025 Plot Plan APPROVED PLOT PLAN
07/11/2025 Approved Plans APPROVED TRUSS LAYOUT
07/11/2025 Approved Plans APPROVED TRUSS PACKAGE
07/11/2025 Permit Codes Residential Plan Review
07/11/2025 Permit DS Building Permit
07/11/2025 Receipt Receipt for transaction:2025-005419
09/16/2025 Approved Plans 9-16-25 APPROVED PLANS
09/16/2025 Plot Plan 9-16-25 APPROVED PLOT PLAN
09/17/2025 3RD Party Insp Report 2400 Bailey Farms- FTNG - Stamped
09/19/2025 Letter INSPECTION SUMMARY
09/19/2025 Letter INSPECTION SUMMARY
09/25/2025 Letter INSPECTION SUMMARY
09/25/2025 Letter INSPECTION SUMMARY
09/26/2025 Letter INSPECTION SUMMARY
10/16/2025 Letter INSPECTION SUMMARY
10/17/2025 Letter INSPECTION SUMMARY
11/12/2025 Letter INSPECTION SUMMARY
11/12/2025 Letter INSPECTION SUMMARY
11/17/2025 Letter INSPECTION SUMMARY
11/19/2025 Letter INSPECTION SUMMARY
11/19/2025 Letter INSPECTION SUMMARY
11/25/2025 Letter INSPECTION SUMMARY
11/25/2025 Letter INSPECTION SUMMARY
12/03/2025 Letter INSPECTION SUMMARY
12/03/2025 Letter INSPECTION SUMMARY
12/03/2025 Letter INSPECTION SUMMARY
12/17/2025 Letter INSPECTION SUMMARY
12/17/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home