Permit Application Status

PRRES20245803


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20245803
Building Permit - Residential
Issued
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK
11/04/2024
11/08/2024
Locations
Contacts
NEW MARK HOMES - KC LLC, Address:5207 NW CROOKED ROAD, Phone:(816) 969-9010  
Ashley Kirby, Address:5207 NW Crooked Rd, Phone:(816) 969-9010  
ASHLEY@NEWMARKHOMESKC.COM  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
ELECTRICAL INVESTMENTS, Address:8014 REEDER ST, Phone:(816) 210-1597  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sanitary Sewer Development Fee $2,285.00 $2,285.00 Paid 11/08/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 11/08/2024
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 11/08/2024
8331401-Water Tap Fee $3,973.00 $3,973.00 Paid 11/08/2024
8350015-Water Meter Fee $748.03 $748.03 Paid 11/08/2024
9110078-Valuation Fee New Single Family $2,374.29 $2,374.29 Paid 11/08/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Plot Plan Inspection Pending
Occupancy Inspection - Codes Residential Pending
Erosion Control Inspection Residential Pending
Misc
Corrective Action Required
03/24/2025
Repair downed silt fence
Footing Inspection - Residential Passed 12/3/2024 12/3/2024 12/03/2024
Underslab Plumbing Inspection - Residential Passed 12/19/2024 12/19/2024 12/19/2024
All Rough Inspection - Residential Failed 1/31/2025 1/31/2025 01/31/2025
Miscellaneous Correction
Informational
01/31/2025
-Garage PFH -Kitchenette CSPF -Back porch All passed and are okay to cover This is a partial pass only
Sewer Service Inspection - R Passed 3/10/2025 3/10/2025 03/10/2025
Water Service Inspection - R Partial 3/10/2025 3/10/2025 03/10/2025
Water Service Inspection - R Passed 3/12/2025 3/12/2025 03/12/2025
Erosion Control Inspection Residential Failed 3/24/2025 03/24/2025
Misc
Corrective Action Required
03/24/2025
Repair downed silt fence
Gas Service Inspection - Residential Failed 3/27/2025 3/27/2025 03/27/2025
Misc
Corrective Action Required
03/27/2025
Provide approved ufer ground connection
G2417.4.1 Test Pressure
Corrective Action Required
03/27/2025
INSPECTION, TESTING AND PURGING. AMENDED 7-945. The test pressure to be used shall be not less than one and one-half times the proposed maximum working pressure, but not less than 10 psig (68.9kPa) irrespective of design pressure. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure, the test pressure shall not be less than 60 psig. Where the test pressure exceeds 125 psig (862 kPa gauge), the test pressure shall not exceed a value that produces a hoop stress in the piping greater than 50 percent of the specified minimum yield strength of the pipe.
Electrical Service Inspection Failed 3/27/2025 3/27/2025 03/27/2025
Misc
Corrective Action Required
03/27/2025
Use approved ufer ground connection
All Rough Inspection - Residential Failed 3/27/2025 3/27/2025 03/27/2025
Miscellaneous Correction
Resolved
03/27/2025
-Garage PFH -Kitchenette CSPF -Back porch All passed and are okay to cover This is a partial pass only
Misc
Corrective Action Required
03/27/2025
-nail plate under header into header to code at pfh -nail all intersecting exterior wall corners together to plans -furr around for bath vent in garage -furr down for insulation in garage where joist space filled by dwv -address missing nails in hangers throughout kitchen -provide security blocking at rear door -fireblock wall space to ceiling space at fireplace -missing nails in hanger for double lvl above owners suite -fireblock owners bath wall space to ceiling space -provide all NM within 6’ of attic access 1st and 2nd floor -protect dryer vent at top plate to code 1st and 2nd floor -fireblock basement stairwell wall/flex room to ceiling space seal dead spaces as well -add studs at flex room closet where missing -fireblock top or 2nd story stairwell wall to ceiling space -provide appropriate hangers for joists above panel -secure/support electrical run next to stairs in basement -provide solid blocking under kitchen area to plans
All Rough Inspection - Residential Passed 3/31/2025 3/31/2025 03/31/2025
Misc
Resolved
03/31/2025
-nail plate under header into header to code at pfh -nail all intersecting exterior wall corners together to plans -furr around for bath vent in garage -furr down for insulation in garage where joist space filled by dwv -address missing nails in hangers throughout kitchen -provide security blocking at rear door -fireblock wall space to ceiling space at fireplace -missing nails in hanger for double lvl above owners suite -fireblock owners bath wall space to ceiling space -provide all NM within 6’ of attic access 1st and 2nd floor -protect dryer vent at top plate to code 1st and 2nd floor -fireblock basement stairwell wall/flex room to ceiling space seal dead spaces as well -add studs at flex room closet where missing -fireblock top or 2nd story stairwell wall to ceiling space -provide appropriate hangers for joists above panel -secure/support electrical run next to stairs in basement -provide solid blocking under kitchen area to plans
Electrical Service Inspection Passed 3/31/2025 3/31/2025 03/31/2025
Misc
Resolved
03/31/2025
Use approved ufer ground connection
Gas Service Inspection - Residential Passed 3/31/2025 3/31/2025 03/31/2025
Misc
Resolved
03/31/2025
Provide approved ufer ground connection
G2417.4.1 Test Pressure
Resolved
03/31/2025
INSPECTION, TESTING AND PURGING. AMENDED 7-945. The test pressure to be used shall be not less than one and one-half times the proposed maximum working pressure, but not less than 10 psig (68.9kPa) irrespective of design pressure. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure, the test pressure shall not be less than 60 psig. Where the test pressure exceeds 125 psig (862 kPa gauge), the test pressure shall not exceed a value that produces a hoop stress in the piping greater than 50 percent of the specified minimum yield strength of the pipe.
Sidewalk Inspection Partial 4/10/2025 04/10/2025
Misc
Informational
04/10/2025
4-10-25 Dustin A, Sw has been formed and compacted. Slopes are in compliance. Approved to pour. ** before final is given ada ramp needs cleaned off for inspection.
Driveway Inspection Partial 4/10/2025 04/10/2025
Misc
Informational
04/10/2025
4-10-25 Dustin A, DW is formed and compacted. Approved to pour
Driveway Inspection Partial 4/17/2025 4/17/2025 04/17/2025
Misc
Informational
04/10/2025
4-10-25 Dustin A, DW is formed and compacted. Approved to pour 04-17-25 Jamie S, DW slopes are in compliance with city standards.
Sidewalk Inspection Failed 4/17/2025 4/17/2025 04/17/2025
Misc
Informational
04/10/2025
4-10-25 Dustin A, Sw has been formed and compacted. Slopes are in compliance. Approved to pour. ** before final is given ada ramp needs cleaned off for inspection. 04-17-25 Jamie S, ADA ramp needs to be cleaned off for inspection. Slopes are in compliance with city standards. Call in for re-inspection.
Sidewalk Inspection Passed 04/22/2025
Misc
Informational
04/17/2025
4-10-25 Dustin A, Sw has been formed and compacted. Slopes are in compliance. Approved to pour. ** before final is given ada ramp needs cleaned off for inspection. 04-17-25 Jamie S, ADA ramp needs to be cleaned off for inspection. Slopes are in compliance with city standards. Call in for re-inspection. 4-22-25 Dustin A, Ramp has been cleaned off . Pass
Sidewalk Inspection Passed 4/22/2025 4/22/2025 04/22/2025
Driveway Inspection Passed 04/22/2025
Misc
Informational
04/17/2025
4-10-25 Dustin A, DW is formed and compacted. Approved to pour 04-17-25 Jamie S, DW slopes are in compliance with city standards.
Documents & Images
Date Uploaded File Type Document Name
11/04/2024 HKF81 - Lee's Summit Permit Application Packet
11/07/2024 Approved Plans APPROVED PLANS
11/07/2024 Plot Plan APPROVED PLOT PLAN
11/08/2024 Permit Codes Residential Plan Review
11/08/2024 Permit DS Building Permit
11/08/2024 Receipt Receipt for transaction:2024-008849
12/03/2024 Letter INSPECTION SUMMARY
12/19/2024 Letter INSPECTION SUMMARY
12/30/2024 2805 SW Hearthstone St_ALL SLAB & DECK PIER INSP_2024-12-23
01/31/2025 Letter INSPECTION SUMMARY
03/10/2025 Letter INSPECTION SUMMARY
03/10/2025 Letter INSPECTION SUMMARY
03/12/2025 Letter INSPECTION SUMMARY
03/24/2025 Letter INSPECTION SUMMARY
03/27/2025 Letter INSPECTION SUMMARY
03/27/2025 Letter INSPECTION SUMMARY
03/27/2025 Letter INSPECTION SUMMARY
03/31/2025 2805 SW Hearthstone_Framing Evaluation Report_3-28-25
03/31/2025 Letter INSPECTION SUMMARY
03/31/2025 Letter INSPECTION SUMMARY
03/31/2025 Letter INSPECTION SUMMARY
04/10/2025 Letter INSPECTION SUMMARY
04/10/2025 Letter INSPECTION SUMMARY
04/17/2025 Letter INSPECTION SUMMARY
04/17/2025 Letter INSPECTION SUMMARY
04/17/2025 Letter INSPECTION SUMMARY
04/22/2025 Letter INSPECTION SUMMARY
04/22/2025 Letter INSPECTION SUMMARY
04/22/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home