Permit Application Status

PRRES20245553


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20245553
Building Permit - Residential
Temporary Occupancy
DOMAIN TIMBERLAKE MULTISTATE LLC
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. WALKOUT BASEMENT. ROOF TRUSSES.
10/21/2024
10/29/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
DOMAIN TIMBERLAKE MULTISTATE LLC, Address:590 MADISON AVE FL 13TH  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
TREVOR@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331401-Water Tap Fee $3,973.00 $3,973.00 Paid 10/29/2024
8350015-Water Meter Fee $748.03 $748.03 Paid 10/29/2024
8331507-Sanitary Sewer Development Fee $2,285.00 $2,285.00 Paid 10/29/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 10/29/2024
7232302-Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 10/29/2024
9110078-Valuation Fee New Single Family $1,979.41 $1,979.41 Paid 10/29/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 05/23/2025
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 05/23/2025
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 05/23/2025
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 05/23/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Driveway Inspection Pending
Misc
Informational
04/30/2025
04-23-25 Jamie S, DW is formed and compacted. Approved to pour. 04-30-25 Jamie S, DW slopes are in compliance with city standards.
Sidewalk Inspection Pending
Misc
Informational
04/30/2025
04-23-25 Jamie S, SW is formed and compacted. Approved to pour. 04-30-25 Jamie S, SW slopes are in compliance with city standards.
Plot Plan Inspection Pending
Misc
Corrective Action Required
05/20/2025
Final grade needed and excess material removed
Erosion Control Inspection Residential Pending
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
05/20/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - REMOVE LOOSE TRASH FROM LOT
Misc
Corrective Action Required
05/20/2025
Remove excess Material and trash from the lot
Occupancy Inspection - Codes Residential Pending
Misc
Corrective Action Required
05/23/2025
3211 SW Arbor Sound - yard grading needs to be completed and sod installed - splash blocks need to be in place and sump discharge installed -pay all outstanding fees -driveway and sidewalk final inspections - completed plot plan inspection needed
Footing Inspection - Residential Passed 12/2/2024 12/02/2024
Sewer Service Inspection - R Passed 12/2/2024 12/2/2024 12/02/2024
Water Service Inspection - R Partial 12/2/2024 12/2/2024 12/02/2024
Misc
Corrective Action Required
12/02/2024
Partial- 25' of poly from foundation toward street.
Water Service Inspection - R Passed 12/3/2024 12/3/2024 12/03/2024
Misc
Corrective Action Required
12/02/2024
Partial- 25' of poly from foundation toward street.
Underslab Plumbing Inspection - Residential Passed 12/12/2024 12/12/2024 12/12/2024
All Rough Inspection - Residential Failed 1/27/2025 1/27/2025 01/27/2025
Misc
Corrective Action Required
01/27/2025
Portal frame inspection only Garage portal frame nailing not nailed to design specifications
Erosion Control Inspection Residential Failed 2/3/2025 02/03/2025
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/03/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - REMOVE LOOSE TRASH FROM LOT
All Rough Inspection - Residential Failed 2/3/2025 2/3/2025 02/03/2025
Misc
Corrective Action Required
01/27/2025
Portal frame inspection only - PORTAL FRAME OK - FRONT PORCH OK
Electrical Service Inspection Not Ready 2/21/2025 2/21/2025 02/21/2025
Misc
Corrective Action Required
02/21/2025
Electrical not installed.
All Rough Inspection - Residential Not Ready 2/21/2025 2/21/2025 02/21/2025
Misc
Corrective Action Required
02/03/2025
Portal frame inspection only - PORTAL FRAME OK - FRONT PORCH OK
Misc
Corrective Action Required
02/21/2025
Trades not completed not ready for inspection
Gas Service Inspection - Residential Failed 3/11/2025 3/11/2025 03/11/2025
G2417.4.1 Test Pressure
Corrective Action Required
03/11/2025
INSPECTION, TESTING AND PURGING. AMENDED 7-945. The test pressure to be used shall be not less than one and one-half times the proposed maximum working pressure, but not less than 10 psig (68.9kPa) irrespective of design pressure. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure, the test pressure shall not be less than 60 psig. Where the test pressure exceeds 125 psig (862 kPa gauge), the test pressure shall not exceed a value that produces a hoop stress in the piping greater than 50 percent of the specified minimum yield strength of the pipe.
Electrical Service Inspection Passed 3/11/2025 3/11/2025 03/11/2025
Misc
Resolved
03/11/2025
Electrical not installed.
All Rough Inspection - Residential Failed 3/11/2025 3/11/2025 03/11/2025
Misc
Resolved
03/11/2025
Portal frame inspection only - PORTAL FRAME OK - FRONT PORCH OK
Misc
Resolved
03/11/2025
Trades not completed not ready for inspection
Misc
Corrective Action Required
03/11/2025
-fireblock wall space to ceiling space at rear garage wall -uncover steel column in garage for inspection -fire block hvac chase to ceiling space in pantry -provide protection for dryer vent at top plate penetration -seal bottom plate penetrations at bed 2 entry -would block sheathing breaks primary bedroom closet -seal top plate penetrations in laundry -for block foyer walls into garage furr down -fireblock garage stud space into stairs landing joist space -3 studs minimum at all exterior wall corners tying walls together (see basement) -sister full length wall studs where over notched(for anchor bolts) -deck not constructed at time of inspection
Gas Service Inspection - Residential Failed 3/13/2025 3/13/2025 03/13/2025
G2417.4.1 Test Pressure
Corrective Action Required
03/11/2025
INSPECTION, TESTING AND PURGING. AMENDED 7-945. The test pressure to be used shall be not less than one and one-half times the proposed maximum working pressure, but not less than 10 psig (68.9kPa) irrespective of design pressure. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure, the test pressure shall not be less than 60 psig. Where the test pressure exceeds 125 psig (862 kPa gauge), the test pressure shall not exceed a value that produces a hoop stress in the piping greater than 50 percent of the specified minimum yield strength of the pipe.
All Rough Inspection - Residential Not Ready 3/13/2025 3/13/2025 03/13/2025
Misc
Corrective Action Required
03/11/2025
-fireblock wall space to ceiling space at rear garage wall -fire block hvac chase to ceiling space in pantry -provide protection for dryer vent at top plate penetration -seal top plate penetrations in laundry -for block foyer walls into garage furr down -fireblock garage stud space into stairs landing joist space -3 studs minimum at all exterior wall corners tying walls together (see basement) -deck not constructed at time of inspection
Gas Service Inspection - Residential Passed 3/17/2025 3/17/2025 03/17/2025
G2417.4.1 Test Pressure
Resolved
03/17/2025
INSPECTION, TESTING AND PURGING. AMENDED 7-945. The test pressure to be used shall be not less than one and one-half times the proposed maximum working pressure, but not less than 10 psig (68.9kPa) irrespective of design pressure. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure, the test pressure shall not be less than 60 psig. Where the test pressure exceeds 125 psig (862 kPa gauge), the test pressure shall not exceed a value that produces a hoop stress in the piping greater than 50 percent of the specified minimum yield strength of the pipe.
All Rough Inspection - Residential Failed 3/17/2025 3/17/2025 03/17/2025
Misc
Corrective Action Required
03/13/2025
Fire blocking material must be of approved materials -fireblock wall space to ceiling space at rear garage wall -fire block hvac chase to ceiling space in pantry -provide protection for dryer vent at top plate penetration -fire block foyer walls into garage furr down -fireblock garage stud space into stairs landing joist space(seal gaps) -deck not constructed at time of inspection
All Rough Inspection - Residential Passed 3/19/2025 3/19/2025 03/19/2025
Misc
Resolved
03/19/2025
Fire blocking material must be of approved materials -fireblock wall space to ceiling space at rear garage wall -fire block hvac chase to ceiling space in pantry -provide protection for dryer vent at top plate penetration -fire block foyer walls into garage furr down -fireblock garage stud space into stairs landing joist space(seal gaps) -deck not constructed at time of inspection
Driveway Inspection Partial 4/23/2025 4/23/2025 04/23/2025
Misc
Informational
04/23/2025
04-23-25 Jamie S, DW is formed and compacted. Approved to pour.
Sidewalk Inspection Partial 4/23/2025 4/23/2025 04/23/2025
Misc
Informational
04/23/2025
04-23-25 Jamie S, SW is formed and compacted. Approved to pour.
Driveway Inspection Partial 4/30/2025 4/30/2025 04/30/2025
Misc
Informational
04/23/2025
04-23-25 Jamie S, DW is formed and compacted. Approved to pour. 04-30-25 Jamie S, DW slopes are in compliance with city standards.
Sidewalk Inspection Partial 4/30/2025 4/30/2025 04/30/2025
Misc
Informational
04/23/2025
04-23-25 Jamie S, SW is formed and compacted. Approved to pour. 04-30-25 Jamie S, SW slopes are in compliance with city standards.
Plot Plan Inspection Failed 5/16/2025 05/16/2025
Misc
Corrective Action Required
05/16/2025
Final grade needed and excess material removed
Erosion Control Inspection Residential Partial 5/16/2025 05/16/2025
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/03/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - REMOVE LOOSE TRASH FROM LOT
Occupancy Inspection - Codes Residential Failed 5/16/2025 5/16/2025 05/16/2025
Misc
Corrective Action Required
05/16/2025
3211 SW Arbor Sound dr - Barrier/railing needed for front porch - Deck needs completed - Door from house to garage must be self closing - Deck landing must be completed - Need security screws installed in basement door hinges and latch plate - Outlet above furnace for fan box must be marked as non gfci -
Occupancy Inspection - Codes Residential Failed 5/20/2025 5/20/2025 05/20/2025
Misc
Corrective Action Required
05/16/2025
3211 SW Arbor Sound dr - Barrier/railing needed for front porch - all Deck posts to beam connections must have thru bolts or approved brackets as per code - Door from house to garage must be self closing - Deck landing must be completed - Need security screws installed in basement door hinges and latch plate - Outlet above furnace for fan box must be marked as non gfci - yard grading needs to be completed and sod installed - splash blocks need to be in place and sump discharge installed -pay all outstanding fees -driveway and sidewalk final inspections needed - reinstall handrail in stairway - completed plot plan inspection needed
Plot Plan Inspection Failed 5/20/2025 05/20/2025
Misc
Corrective Action Required
05/16/2025
Final grade needed and excess material removed
Erosion Control Inspection Residential Failed 5/20/2025 05/20/2025
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
05/16/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - REMOVE LOOSE TRASH FROM LOT
Misc
Corrective Action Required
05/20/2025
Remove excess Material and trash from the lot
Occupancy Inspection - Codes Residential Failed 5/22/2025 5/22/2025 05/22/2025
Misc
Corrective Action Required
05/20/2025
3211 SW Arbor Sound dr - Barrier/railing needed for front porch - handrail needed in stairway - yard grading needs to be completed and sod installed - splash blocks need to be in place and sump discharge installed -pay all outstanding fees -driveway and sidewalk final inspections - completed plot plan inspection needed
Occupancy Inspection - Codes Residential Ready for Temp CO 5/23/2025 5/23/2025 05/23/2025
Misc
Corrective Action Required
05/22/2025
3211 SW Arbor Sound - yard grading needs to be completed and sod installed - splash blocks need to be in place and sump discharge installed -pay all outstanding fees -driveway and sidewalk final inspections - completed plot plan inspection needed
Documents & Images
Date Uploaded File Type Document Name
10/21/2024 HT #198 - PERMIT APP
10/28/2024 Approved Plans APPROVED PLANS
10/28/2024 Plot Plan APPROVED PLOT PLAN
10/28/2024 Approved Plans APPROVED TRUSS PACKAGE
10/28/2024 Approved Plans APPROVED TRUSS LAYOUT
10/28/2024 Permit Codes Residential Plan Review
10/29/2024 Permit DS Building Permit
10/29/2024 Receipt Receipt for transaction:2024-008613
11/19/2024 3RD Party Insp Report THIRD PARTY FOOTING INSPECTION
12/02/2024 Letter INSPECTION SUMMARY
12/02/2024 Letter INSPECTION SUMMARY
12/02/2024 Letter INSPECTION SUMMARY
12/12/2024 Letter INSPECTION SUMMARY
12/12/2024 Letter INSPECTION SUMMARY
01/27/2025 Letter INSPECTION SUMMARY
02/03/2025 Letter INSPECTION SUMMARY
02/03/2025 Letter INSPECTION SUMMARY
02/21/2025 Letter INSPECTION SUMMARY
02/21/2025 Letter INSPECTION SUMMARY
03/11/2025 Letter INSPECTION SUMMARY
03/11/2025 Letter INSPECTION SUMMARY
03/11/2025 Letter INSPECTION SUMMARY
03/17/2025 Letter INSPECTION SUMMARY
03/17/2025 Letter INSPECTION SUMMARY
03/17/2025 Letter INSPECTION SUMMARY
03/17/2025 Letter INSPECTION SUMMARY
03/19/2025 Letter INSPECTION SUMMARY
04/23/2025 Letter INSPECTION SUMMARY
04/23/2025 Letter INSPECTION SUMMARY
04/30/2025 Letter INSPECTION SUMMARY
04/30/2025 Letter INSPECTION SUMMARY
05/16/2025 Letter INSPECTION SUMMARY
05/16/2025 Letter INSPECTION SUMMARY
05/16/2025 Letter INSPECTION SUMMARY
05/20/2025 Letter INSPECTION SUMMARY
05/20/2025 Letter INSPECTION SUMMARY
05/20/2025 Letter INSPECTION SUMMARY
05/22/2025 Letter INSPECTION SUMMARY
05/23/2025 Letter INSPECTION SUMMARY
05/23/2025 Certificate/License Codes Temporary Certificate of Occupancy
05/23/2025 Receipt Receipt for transaction:2025-003779
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide: