Permit Application Status

PRRES20245409


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20245409
Building Permit - Residential
Temporary Occupancy
DOMAIN TIMBERLAKE MULTISTATE LLC
NEW SINGLE FAMILY
NEW HOUSE - UNIFNISHED BASEMENT - ROOF TRUSSES - UNCOVERED DECK
10/14/2024
10/14/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
DOMAIN TIMBERLAKE MULTISTATE LLC, Address:590 MADISON AVE FL 13TH  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
BRUCER@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sanitary Sewer Development Fee $2,285.00 $2,285.00 Paid 10/14/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 10/14/2024
7232302-Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 10/14/2024
8331401-Water Tap Fee $3,973.00 $3,973.00 Paid 10/14/2024
8350015-Water Meter Fee $748.03 $748.03 Paid 10/14/2024
9110078-Valuation Fee New Single Family $1,236.00 $1,236.00 Paid 10/14/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 03/25/2025
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 04/24/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Plot Plan Inspection Pending
Erosion Control Inspection Residential Pending
Miscellaneous Correction
Corrective Action Required
03/24/2025
Erosion control measures are in place at the time of inspection Clean lot up from trash and debris Erosion control to remain in place until sod
Occupancy Inspection - Codes Residential Pending 5/24/2025
Misc
Corrective Action Required
04/24/2025
-final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -install gutters -land sewer tracer wire in box -address deck post to beam connection deck post over notched. Provide approved deck post to be connector
Footing Inspection - Residential Passed 10/30/2024 10/30/2024 10/30/2024
Erosion Control Inspection Residential Partial 10/30/2024 10/30/2024 10/30/2024
Sewer Service Inspection - R Passed 11/5/2024 11/5/2024 11/05/2024
Water Service Inspection - R Passed 11/6/2024 11/6/2024 11/06/2024
Underslab Plumbing Inspection - Residential Passed 12/4/2024 12/4/2024 12/04/2024
Erosion Control Inspection Residential Failed 12/4/2024 12/4/2024 12/04/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
12/04/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
All Rough Inspection - Residential Partial 12/20/2024 12/20/2024 12/20/2024
Misc
Informational
12/20/2024
Garage portal nailing inspected only.
Erosion Control Inspection Residential Failed 1/28/2025 01/28/2025
DCM3 ESC REQUIRED 2 DAY
Resolved
01/28/2025
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Miscellaneous Correction
Corrective Action Required
01/28/2025
Erosion control measures are in place at the time of inspection Clean lot up from trash and debris
Electrical Service Inspection Passed 1/28/2025 1/28/2025 01/28/2025
Gas Service Inspection - Residential Passed 1/28/2025 1/28/2025 01/28/2025
All Rough Inspection - Residential Failed 1/28/2025 1/28/2025 01/28/2025
Misc
Resolved
01/28/2025
Garage portal nailing inspected only.
Miscellaneous Correction
Corrective Action Required
01/28/2025
- Garage NW corner anchor bolt needs to be in the middle 1/3 of the bottom plate - Garage bottom plate east wall is missing the anchor bolt washer and nut - Nail north east side 2x8 bottom cord of garage GT - Corner of garage to laundry room needs to have a third stud installed - Install snow flashing in gable above garage double overhead door - Fully install truss tie down screws in garage SE corner - Truss tie down screws are not installed in laundry room - Roof boot flashing jackets are not installed - Hole in the subfloor at the kitchen island - Nails are missing in joist hanger in basement at stairwell - 8x18 steel Ibeam in basement SW mechanical corner does not sit on the required 3 inches of concrete
All Rough Inspection - Residential Passed 1/30/2025 1/30/2025 01/30/2025
Miscellaneous Correction
Resolved
01/30/2025
- Garage NW corner anchor bolt needs to be in the middle 1/3 of the bottom plate - Garage bottom plate east wall is missing the anchor bolt washer and nut - Nail north east side 2x8 bottom cord of garage GT - Corner of garage to laundry room needs to have a third stud installed - Install snow flashing in gable above garage double overhead door - Fully install truss tie down screws in garage SE corner - Truss tie down screws are not installed in laundry room - Roof boot flashing jackets are not installed - Hole in the subfloor at the kitchen island - Nails are missing in joist hanger in basement at stairwell - 8x18 steel Ibeam in basement SW mechanical corner does not sit on the required 3 inches of concrete
Driveway Inspection Partial 3/13/2025 3/13/2025 03/13/2025
Misc
Informational
03/13/2025
3-13-25 Dustin A, Dw is formed and compacted, Approved to pour
Piers/Caissons Inspection - Residential Failed 3/13/2025 3/13/2025 03/13/2025
Misc
Corrective Action Required
03/13/2025
East pier okay West pier caving in and no rebar.
Sidewalk Inspection Partial 3/13/2025 3/13/2025 03/13/2025
Misc
Informational
03/13/2025
3-13-25 Dustin A, SW is formed and compacted and slopes are in compliance. Approved to pour,
Piers/Caissons Inspection - Residential Passed 3/13/2025 3/13/2025 03/13/2025
Misc
Resolved
03/13/2025
East pier okay West pier caving in and no rebar.
Driveway Inspection Passed 3/20/2025 3/20/2025 03/20/2025
Misc
Informational
03/13/2025
3-13-25 Dustin A, Dw is formed and compacted, Approved to pour 3-20-25 Dustin A, Dw is poured to city specs and slopes are in compliance . Pass
Sidewalk Inspection Passed 3/20/2025 3/20/2025 03/20/2025
Misc
Informational
03/13/2025
3-13-25 Dustin A, SW is formed and compacted and slopes are in compliance. Approved to pour, 3-20-25 sw is poured to city specs and slopes are in compliance. Pass
Occupancy Inspection - Codes Residential Failed 3/24/2025 3/24/2025 03/24/2025
Misc
Corrective Action Required
03/24/2025
Inspection denied. Erosion control not in compliance
Erosion Control Inspection Residential Failed 03/24/2025
Miscellaneous Correction
Corrective Action Required
03/24/2025
Clean lot up from trash and debris Erosion control to remain in place until sod
Occupancy Inspection - Codes Residential Ready for Temp CO 3/25/2025 3/25/2025 03/25/2025
Misc
Resolved
03/25/2025
Inspection denied. Erosion control not in compliance
Misc
Corrective Action Required
03/25/2025
-final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -install gutters -land sewer tracer wire in box -address deck post to beam connection deck post over notched. Provide approved deck post to be connector
Occupancy Inspection - Codes Residential Ready for Temp CO 4/24/2025 04/24/2025
Misc
Corrective Action Required
03/25/2025
-final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -install gutters -land sewer tracer wire in box -address deck post to beam connection deck post over notched. Provide approved deck post to be connector
Documents & Images
Date Uploaded File Type Document Name
10/14/2024 HT #162 - PERMIT APP
10/14/2024 Approved Plans APPROVED PLANS
10/14/2024 Plot Plan APPROVED PLOT PLAN
10/14/2024 Approved Plans APPROVED TRUSS LAYOUT
10/14/2024 Approved Plans APPROVED TRUSS PACKAGE
10/14/2024 Permit Codes Residential Plan Review
10/14/2024 Permit DS Building Permit
10/14/2024 Receipt Receipt for transaction:2024-008314
10/29/2024 3RD Party Insp Report M L Crose 1616 Buckthorn St, LSMO 3rd Party Footing Inspection Report 10-29-24
10/30/2024 Letter INSPECTION SUMMARY
10/30/2024 Letter INSPECTION SUMMARY
11/05/2024 Letter INSPECTION SUMMARY
11/06/2024 Letter INSPECTION SUMMARY
12/04/2024 Letter INSPECTION SUMMARY
12/04/2024 Letter INSPECTION SUMMARY
12/20/2024 Letter INSPECTION SUMMARY
01/28/2025 Letter INSPECTION SUMMARY
01/28/2025 Letter INSPECTION SUMMARY
01/28/2025 Letter INSPECTION SUMMARY
01/28/2025 Letter INSPECTION SUMMARY
01/30/2025 Letter INSPECTION SUMMARY
03/13/2025 Letter INSPECTION SUMMARY
03/13/2025 Letter INSPECTION SUMMARY
03/13/2025 Letter INSPECTION SUMMARY
03/13/2025 Letter INSPECTION SUMMARY
03/13/2025 Letter INSPECTION SUMMARY
03/20/2025 Letter INSPECTION SUMMARY
03/20/2025 Letter INSPECTION SUMMARY
03/24/2025 Letter INSPECTION SUMMARY
03/24/2025 Letter INSPECTION SUMMARY
03/24/2025 Letter INSPECTION SUMMARY
03/25/2025 Letter INSPECTION SUMMARY
03/25/2025 Certificate/License Codes Temporary Certificate of Occupancy
03/25/2025 Receipt Receipt for transaction:2025-001770
04/15/2025 HT #162 - TCO Extension 4_15_25
04/24/2025 Letter INSPECTION SUMMARY
04/24/2025 Certificate/License Codes Temporary Certificate of Occupancy
04/24/2025 Receipt Receipt for transaction:2025-002577
05/20/2025 HT #162 - TCO Extension 5_20_25
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home