Permit Application Status

PRRES20244922


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20244922
Building Permit - Residential
Issued
SUMMIT VIEW FARMS DEVELOPMENT GROUP LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED DECK - OWNER BUILDER STOP WORK ORDER generated on 10/28/2024 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 11/19/2024 12:00 AM by username 'Shawn Hoffman'.
09/17/2024
10/09/2024
03/30/2025
Locations
Contacts
JW Thomas LLC, Address:14704 S Hutt rd  
SUMMIT VIEW FARMS DEVELOPMENT GROUP LLC, Address:13450 E STATE ROUTE 150  
Jeffrey Boehm, Address:14704 S Hutt rd, Phone:(816) 588-3193  
JW Thomas LLC, Address:14704 S Hutt rd  
Wes Boehm <wes@jw-thomas.com>  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sanitary Sewer Development Fee $2,285.00 $2,285.00 Paid 10/09/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 10/09/2024
7232302-Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 10/09/2024
8331401-Water Tap Fee $3,973.00 $3,973.00 Paid 10/09/2024
8350015-Water Meter Fee $748.03 $748.03 Paid 10/09/2024
9110078-Valuation Fee New Single Family $2,168.74 $2,168.74 Paid 10/09/2024
Outstanding Fees Amount Paid Owing Date Paid
9110080-Not Ready Inspection Fee $75.00 $0.00 $75.00 Not Paid
9110080-3rd and Subsequent Inspection Fee (Per Hour) $75.00 $0.00 $75.00 Not Paid
9110080-3rd and Subsequent Inspection Fee (Per Hour) $75.00 $0.00 $75.00 Not Paid
9110080-Not Ready Inspection Fee $75.00 $0.00 $75.00 Not Paid


$300.00    Add Fees to My Cart
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Plot Plan Inspection Pending
Occupancy Inspection - Codes Residential Pending
Erosion Control Inspection Residential Pending
Misc
Corrective Action Required
04/30/2025
- EROSION CONTROL IN PLACE AT TIME OF INSPECTION.
Sidewalk Inspection Pending
Misc
Informational
06/06/2025
4-14-25 Dustin A, Sw has been formed and compacted along kline. Slopes are in compliance. There is a buried manhole that will need to be exposed before final sw inspection is given. 4-21-25 Dustin A, sw has been poured. 2 panels near storm drain are out of ada compliance. Fail 06-06-25 Jamie S, SW is formed and grave is compacted. Approved to Pour.
Erosion Control Inspection Residential Failed 10/17/2024 10/17/2024 10/17/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
10/17/2024
10-17-24 Dustin A, dirt piles have pushed over Erosion control, Dirt now on SW. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Footing Inspection - Residential Failed - Stop Work 10/28/2024 10/28/2024 10/28/2024
Misc
Corrective Action Required
10/28/2024
Erosion control not in place at time of site visit. Stop work issued.
Erosion Control Inspection Residential Failed - Stop Work 10/28/2024 10/28/2024 10/28/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
10/17/2024
10-17-24 Dustin A, dirt piles have pushed over Erosion control, Dirt now on SW. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 10/28/24-erosion control not in compliance.
Erosion Control Inspection Residential Failed 11/15/2024 11/15/2024 11/15/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
10/28/2024
10-17-24 Dustin A, dirt piles have pushed over Erosion control, Dirt now on SW. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 10/28/24-erosion control not in compliance.
Misc
Corrective Action Required
11/15/2024
- POST ADDRESS - REMOVE MUD AND GRAVEL FROM STREET
Erosion Control Inspection Residential Partial 11/19/2024 11/19/2024 11/19/2024
DCM3 ESC REQUIRED 2 DAY
Resolved
11/19/2024
10-17-24 Dustin A, dirt piles have pushed over Erosion control, Dirt now on SW. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 10/28/24-erosion control not in compliance.
Misc
Resolved
11/19/2024
- POST ADDRESS - REMOVE MUD AND GRAVEL FROM STREET
Misc
Corrective Action Required
11/19/2024
- EROSION CONTROL IN PLACE AT TIME OF INSPECTION.
All Rough Inspection - Residential Failed 11/20/2024 11/20/2024 11/20/2024
Miscellaneous Correction
Informational
11/20/2024
All rough was scheduled by the city staff instead of a under slab plumbing inspection KBEARD
Footing Inspection - Residential Passed 11/20/2024 11/20/2024
Misc
Resolved
11/20/2024
Erosion control not in place at time of site visit. Stop work issued.
Miscellaneous Correction
Informational
11/20/2024
Footing was passed by a third party on 10/24/24
Underslab Plumbing Inspection - Residential Failed 11/18/2024 11/20/2024 11/20/2024
Miscellaneous Correction
Corrective Action Required
11/20/2024
Re bed plumbing lines where necessary
Sewer Service Inspection - R Passed 11/21/2024 11/21/2024 11/21/2024
Piers/Caissons Inspection - Residential Failed 11/22/2024 11/22/2024 11/22/2024
Informational
11/22/2024
piers not complete, Guy working said would not be ready in time for inspection today.
Water Service Inspection - R Partial 11/22/2024 11/22/2024
Misc
Corrective Action Required
11/22/2024
PARTIAL, Tap, meter, 10' of copper, 30' of poly toward foundation
Piers/Caissons Inspection - Residential Passed 11/25/2024 11/25/2024 11/25/2024
Water Service Inspection - R Passed 11/25/2024 11/25/2024 11/25/2024
Misc
Resolved
11/25/2024
PARTIAL, Tap, meter, 10' of copper, 30' of poly toward foundation
Underslab Plumbing Inspection - Residential Passed 11/26/2024 11/26/2024 11/26/2024
Miscellaneous Correction
Resolved
11/26/2024
Re bed plumbing lines where necessary
All Rough Inspection - Residential Failed 3/6/2025 03/06/2025
Miscellaneous Correction
Resolved
03/06/2025
All rough was scheduled by the city staff instead of a under slab plumbing inspection KBEARD
Misc
Corrective Action Required
03/06/2025
-Provide complete set of City stamped plans on site for inspection. (If you are wanting gas and electric looked at as well please schedule them with all rough inspection) -ensure address is visible from front of home.
All Rough Inspection - Residential Failed 3/7/2025 3/7/2025 03/07/2025
Misc
Resolved
03/07/2025
-Provide complete set of City stamped plans on site for inspection. (If you are wanting gas and electric looked at as well please schedule them with all rough inspection) -ensure address is visible from front of home.
Misc
Corrective Action Required
03/07/2025
-address missing stud in garage NW wall -fire block wall space to ceiling space at fridge -fire block hvac furr out to ceiling space (must be approved fire blocking materials -furr out for insulation of RA stud gay rear garage -protect NM within 6’ of attic access -missing interior strapping for pfh in garage -nailing to header at pfh covered without inspection -nail plate under header to header per design at pfh in garage -anchor bolts to be in the middle 1/3 of sill plate throughout -complete all bath vents. -fire block office wall space to ceiling space Address holes closer than 2” to each other in floor joist above garage entry closet area -seal penetrations in pantry in joist and stud space used for RA -cs-pf nailing and strapping not done at dining room -seal floor penetration at fireplace -seal penetrations in floor at fireplace in master bedroom -fire block master shower furr out wall to ceiling space -address holes drilled closer than 3” to each other above master bath (multiple spots) -seal penetrations in RA joist space above laundry -strap top plate to code at laundry where cut for RA at load bearing wall -missing nailed in hangers above great room -provide protection for dryer vent at top plate -ensure proper slope to dwv in 2nd floor attic space -fireblock garage wall to stain landing -seal penetrations in return air joist space above rec room -complete plumbing for wet bar in basement -seal penetrations into furr down in basement at wet bar are and rec room E wall -address floor joist under master shower notched for zero entry and board to close to edge of joist (have engineer address onsite fix) -address hole closer than 2” from top of joist for dwv under master toilet -rear patio and front patio roof framing covered without inspection
Electrical Service Inspection Passed 3/7/2025 3/7/2025 03/07/2025
Gas Service Inspection - Residential Failed 3/7/2025 3/7/2025 03/07/2025
Misc
Corrective Action Required
03/07/2025
No pressure at gauge
Gas Service Inspection - Residential Passed 3/17/2025 3/17/2025 03/17/2025
Misc
Resolved
03/17/2025
No pressure at gauge
All Rough Inspection - Residential Not Ready 3/17/2025 3/17/2025 03/17/2025
Misc
Corrective Action Required
03/07/2025
-address missing stud in garage NW wall(stud spacing greater than 16”) -fire block hvac furr out in garage to ceiling space (must be approved fire blocking materials) -furr out for insulation of RA stud bay rear garage -nailing to header at pfh covered without inspection -nail plate under header to header per design at pfh in garage(nail to code) -fire block office wall space to ceiling space -Address holes closer than 2” to each other in floor joist above garage entry closet area (fix to engineer specifications) -seal penetrations in pantry in joist space used for RA -CS-PF required at dining room. Missing. not framed to cspf specifications -fire block master shower furr out wall to ceiling space -address holes drilled closer than 3” to each other above master bath (multiple spots) -seal penetrations in RA joist space above laundry -strap top plate to code at laundry where cut for RA at load bearing wall -missing nailed in hangers above great room -provide protection for dryer vent at top plate -fireblock garage wall to stair landing -seal penetrations in return air joist space above rec room -complete plumbing for wet bar in basement -seal penetrations and gaps into furr down in rec room -address hole closer than 2” from top of joist for dwv under master toilet -rear patio and front patio roof framing covered without inspection
Driveway Inspection Failed 3/17/2025 3/17/2025 03/17/2025
Misc
Corrective Action Required
03/17/2025
3-17-25 Dustin A, Dw is framed and and compacted. There is standing water in approach and it will need to be removed and recompacted. Will need called back in for another inspection
Driveway Inspection Partial 3/17/2025 03/17/2025
Misc
Corrective Action Required
03/17/2025
3-17-25 Dustin A, Dw is framed and and compacted. There is standing water in approach and it will need to be removed and recompacted. Will need called back in for another inspection 3-17-25 Dustin A, water has been removed. and recompacted. Approved to pour
Driveway Inspection Passed 3/24/2025 3/24/2025 03/24/2025
Misc
Corrective Action Required
03/17/2025
3-17-25 Dustin A, Dw is framed and and compacted. There is standing water in approach and it will need to be removed and recompacted. Will need called back in for another inspection 3-17-25 Dustin A, water has been removed. and recompacted. Approved to pour 3-24-25 Dustin A, Dw has been poured to city specs. Pass
All Rough Inspection - Residential Failed 3/26/2025 3/26/2025 03/26/2025
Misc
Corrective Action Required
03/17/2025
-address missing stud in garage NW wall(stud spacing greater than 16”) -furr out for insulation of RA stud bay rear garage -fire block office wall space to ceiling space -seal penetrations in pantry in joist space used for RA -CS-PF required at dining room. Missing. not framed to cspf specifications -fire block master shower furr out wall to ceiling space(1/2” on not approved fire blocking material) -address holes drilled closer than 2” to each other above master bath (multiple spots) -seal penetrations in RA joist space above laundry -strap top plate to code at laundry where cut for RA at load bearing wall -missing nailed in hangers above great room -provide protection for dryer vent at top plate -fireblock garage wall to stair landing -seal penetrations in return air joist space above rec room -complete plumbing for wet bar in basement -seal penetrations and gaps into furr down in rec room -address hole closer than 2” from top of joist for dwv under master toilet(provide hangers at fix) -rear patio and front patio roof framing covered without inspection
All Rough Inspection - Residential Failed 4/2/2025 4/2/2025 04/02/2025
Misc
Corrective Action Required
03/26/2025
-CS-PF required at dining room. Missing. not framed to cspf specifications -fire block master shower furr out wall to ceiling space(1/2” osb not approved fire blocking material) -address holes drilled closer than 2” to each other above master bath (multiple spots) -seal penetrations in RA joist space above laundry -provide protection for dryer vent at top plate
All Rough Inspection - Residential Failed 4/8/2025 4/8/2025 04/08/2025
Misc
Corrective Action Required
04/02/2025
-CS-PF required at dining room. Missing. not framed to cspf specifications (missing king studs, missing nailing etc.) completed per detail -provide protection for dryer vent at top plate
All Rough Inspection - Residential Not Ready 4/9/2025 4/9/2025 04/09/2025
Misc
Corrective Action Required
04/08/2025
**4/9/25 -Nail CSPF header to king studs with min (4) 10d toenails -Dryer duct is required to be protected min 2” below plate line at top plates
All Rough Inspection - Residential Passed 4/10/2025 4/10/2025 04/10/2025
Misc
Resolved
04/10/2025
**4/9/25 -Nail CSPF header to king studs with min (4) 10d toenails -Dryer duct is required to be protected min 2” below plate line at top plates
Sidewalk Inspection Partial 4/14/2025 4/14/2025 04/14/2025
Misc
Informational
04/14/2025
4-14-25 Dustin A, Sw has been formed and compacted along kline. Slopes are in compliance. There is a buried manhole that will need to be exposed before final sw inspection is given.
Sidewalk Inspection Failed 4/21/2025 4/21/2025 04/21/2025
Misc
Informational
04/14/2025
4-14-25 Dustin A, Sw has been formed and compacted along kline. Slopes are in compliance. There is a buried manhole that will need to be exposed before final sw inspection is given. 4-21-25 Dustin A, sw has been poured. 2 panels near storm drain are out of ada compliance. Fail
Erosion Control Inspection Residential Failed 4/25/2025 4/25/2025 04/25/2025
Misc
Corrective Action Required
11/19/2024
- EROSION CONTROL IN PLACE AT TIME OF INSPECTION.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/25/2025
04-25-25 Jamie S, Silt fence is down along Kline Ave. Construction materials are blocking the storm drain. Repair to silt fence and clean-up of construction materials are required. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Partial 4/30/2025 4/30/2025 04/30/2025
Misc
Corrective Action Required
04/25/2025
- EROSION CONTROL IN PLACE AT TIME OF INSPECTION.
DCM3 ESC REQUIRED 2 DAY
Resolved
04/30/2025
04-25-25 Jamie S, Silt fence is down along Kline Ave. Construction materials are blocking the storm drain. Repair to silt fence and clean-up of construction materials are required. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Sidewalk Inspection Partial 6/6/2025 6/6/2025 06/06/2025
Misc
Informational
04/21/2025
4-14-25 Dustin A, Sw has been formed and compacted along kline. Slopes are in compliance. There is a buried manhole that will need to be exposed before final sw inspection is given. 4-21-25 Dustin A, sw has been poured. 2 panels near storm drain are out of ada compliance. Fail 06-06-25 Jamie S, SW is formed and grave is compacted. Approved to Pour.
Documents & Images
Date Uploaded File Type Document Name
09/17/2024 Residental Permit Application 112 SVF
09/17/2024 License_Tax_Application 112 SVF
09/24/2024 Application Form application 1
09/24/2024 Application Form application 2
09/24/2024 Permit Codes Residential Plan Review
09/30/2024 Lot 112 2024-09-30 plot plan
10/01/2024 Permit Codes Residential Plan Review
10/01/2024 Approved Plans APPROVED PLANS
10/02/2024 Lot 112 2024-10-01 plot plan
10/02/2024 Plot Plan APPROVED PLOT PLAN
10/02/2024 Permit Codes Residential Plan Review
10/09/2024 Permit DS Building Permit
10/09/2024 Receipt Receipt for transaction: 2024-008224
10/17/2024 Letter INSPECTION SUMMARY
10/17/2024 Letter INSPECTION SUMMARY
10/27/2024 3rd Party Permit/Approval M L Crose 3205 SW Saddlebred Terr, LSMO 3rd Party Footing Inspection Footing Report 10-24-24
10/28/2024 Letter Stop Work Order
10/28/2024 Letter Stop Work Order
11/15/2024 Letter INSPECTION SUMMARY
11/19/2024 Letter INSPECTION SUMMARY
11/20/2024 Letter INSPECTION SUMMARY
11/20/2024 Letter INSPECTION SUMMARY
11/20/2024 Letter INSPECTION SUMMARY
11/21/2024 Letter INSPECTION SUMMARY
11/22/2024 Letter INSPECTION SUMMARY
11/22/2024 Letter INSPECTION SUMMARY
11/25/2024 Letter INSPECTION SUMMARY
11/25/2024 Letter INSPECTION SUMMARY
11/26/2024 Letter INSPECTION SUMMARY
03/06/2025 Letter INSPECTION SUMMARY
03/07/2025 Letter INSPECTION SUMMARY
03/07/2025 Letter INSPECTION SUMMARY
03/16/2025 Engineer Report/Study 202503161331_3
03/16/2025 Engineer Report/Study 202503161331_2
03/16/2025 Engineer Report/Study 202503161331_1
03/17/2025 Letter INSPECTION SUMMARY
03/17/2025 Letter INSPECTION SUMMARY
03/17/2025 Letter INSPECTION SUMMARY
03/17/2025 Letter INSPECTION SUMMARY
03/17/2025 Letter INSPECTION SUMMARY
03/17/2025 Letter INSPECTION SUMMARY
03/17/2025 Letter INSPECTION SUMMARY
03/24/2025 Letter INSPECTION SUMMARY
03/26/2025 Letter INSPECTION SUMMARY
04/02/2025 Letter INSPECTION SUMMARY
04/08/2025 Letter INSPECTION SUMMARY
04/09/2025 Letter INSPECTION SUMMARY
04/10/2025 Letter INSPECTION SUMMARY
04/14/2025 Letter INSPECTION SUMMARY
04/21/2025 Letter INSPECTION SUMMARY
04/25/2025 Letter INSPECTION SUMMARY
06/06/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home