Permit Application Status

PRRES20244549


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20244549
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. ROOF TRUSSES.
08/27/2024
09/10/2024
03/02/2025
10/13/2025
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
CMH PARKS INC, Address:5000 CLAYTON RD  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
TREVOR@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Water Tap Fee $3,973.00 $3,973.00 Paid 09/10/2024
Water Meter Fee $748.03 $748.03 Paid 09/10/2024
Sanitary Sewer Development Fee $2,285.00 $2,285.00 Paid 09/10/2024
Right of Way Permit Fee $85.00 $85.00 Paid 09/10/2024
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 09/10/2024
Valuation Fee New Single Family $1,443.65 $1,443.65 Paid 09/10/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 03/17/2025
Not Ready Inspection Fee $75.00 $75.00 Paid 03/17/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 03/18/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 04/21/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 10/09/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 10/09/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 10/09/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 10/09/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 10/09/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/3/2024 10/03/2024
Sewer Service Inspection - R Passed 10/29/2024 10/29/2024 10/29/2024
Water Service Inspection - R Partial 10/29/2024 10/29/2024 10/29/2024
Water Service Inspection - R Passed 10/31/2024 10/31/2024
Underslab Plumbing Inspection - Residential Failed 11/1/2024 11/1/2024 11/01/2024
Misc
Corrective Action Required
11/01/2024
-anchor bolts to be in the middle 1/3 of sill plate throughout -nail strapping at garage/front entry wall top plate -nail lib straps to code -missing stud at LIB wall in garage. -address electrical not secured in stud bay at laundry -provide proper support and slop for all dwv throughout main floor -rear primary bedroom and great room not frames to cspf specifications. -strap top plate where lapped less than 24” W foyer wall -strap top plate where lapped less than 24” bed 3 -
Underslab Plumbing Inspection - Residential Failed 11/1/2024 11/1/2024 11/01/2024
Misc
Resolved
11/01/2024
Misc
Corrective Action Required
11/01/2024
-Remove trash and debris from underslab -maintain erosion control
Erosion Control Inspection Residential Failed 11/1/2024 11/1/2024 11/01/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
11/01/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
11/01/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
11/01/2024
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Underslab Plumbing Inspection - Residential Failed 11/4/2024 11/4/2024 11/04/2024
Misc
Corrective Action Required
11/01/2024
-Remove trash and debris from underslab -maintain erosion control
Miscellaneous Correction
Corrective Action Required
11/04/2024
Inspection denied see erosion control dated 11/01/2024 Full erosion control measures must be in place and properly maintained until CofO
Underslab Plumbing Inspection - Residential Passed 11/5/2024 11/5/2024 11/05/2024
Misc
Resolved
11/05/2024
-Remove trash and debris from underslab -maintain erosion control
Miscellaneous Correction
Resolved
11/05/2024
Inspection denied see erosion control dated 11/01/2024 Full erosion control measures must be in place and properly maintained until CofO
All Rough Inspection - Residential Partial 12/10/2024 12/10/2024 12/10/2024
Misc
Informational
12/10/2024
Garage portal frame nailing inspection only. Okay to cover nailing.
Gas Service Inspection - Residential Passed 1/8/2025 1/8/2025 01/08/2025
Electrical Service Inspection Passed 1/8/2025 1/8/2025 01/08/2025
All Rough Inspection - Residential Not Ready 1/8/2025 1/8/2025 01/08/2025
Misc
Informational
12/10/2024
Garage portal frame nailing inspection only. Okay to cover nailing.
Misc
Corrective Action Required
01/08/2025
INSPECTION DENIED PROVID COMPLETE SET OF CITY STAMPED PLANS ON SITE FOR INSPECTION CLEAN ALL CONSTRUCTION DEBRIS FROM GARAGE FOR INSPECTION
All Rough Inspection - Residential Failed 1/10/2025 1/10/2025 01/10/2025
Misc
Resolved
01/10/2025
Garage portal frame nailing inspection only. Okay to cover nailing.
Misc
Resolved
01/10/2025
INSPECTION DENIED PROVID COMPLETE SET OF CITY STAMPED PLANS ON SITE FOR INSPECTION CLEAN ALL CONSTRUCTION DEBRIS FROM GARAGE FOR INSPECTION
Misc
Corrective Action Required
01/10/2025
-address cut beam under master toilet -anchor bolts to be in the middle 1/3 of sill plate
All Rough Inspection - Residential Passed 1/15/2025 1/15/2025 01/15/2025
Misc
Resolved
01/15/2025
-address cut joist under master toilet -anchor bolts to be in the middle 1/3 of sill plate
Piers/Caissons Inspection - Residential Passed 2/27/2025 2/27/2025 02/27/2025
Driveway Inspection Partial 2/27/2025 2/27/2025 02/27/2025
Misc
Informational
02/27/2025
2-27-25 Dustin A, DW is formed and compacted. Approved to pour
Occupancy Inspection - Codes Residential Failed 3/4/2025 3/4/2025 03/04/2025
Misc
Corrective Action Required
03/04/2025
-Final grade and sod -pending driveway inspection -splash blocks and sump pump discharge to extend 36” from foundation -all outlets in unfinished spaces must be gfci protected or single receptacle outlet -secondary locking device at rear slider -complete kitchen hood vent -provide means of preparing food -afci protection at all outlets in kitchen and laundry as required by code. -sewer tracer wire landed in locate box -uncover covered water meter. -deck and exterior not completely checked due to inclement weather conditions
Driveway Inspection Passed 3/6/2025 3/6/2025 03/06/2025
Misc
Informational
02/27/2025
2-27-25 Dustin A, DW is formed and compacted. Approved to pour 3-6-25 Dustin A dw is poured to city specs. Pass
Occupancy Inspection - Codes Residential Failed 3/11/2025 3/11/2025 03/11/2025
Misc
Corrective Action Required
03/04/2025
-Final grade and sod -pending driveway inspection -splash blocks and sump pump discharge to extend 36” from foundation -all outlets in unfinished spaces must be gfci protected or single receptacle outlet -afci protection at all circuits in kitchen as required by code. -water meter to be 14”-18” from top of meter to well ring lid -deck post to beam connection not to code (Missing (2) 1/2” through bolts at post to beam connections)
Occupancy Inspection - Codes Residential Not Ready 3/14/2025 3/14/2025 03/14/2025
Misc
Corrective Action Required
03/11/2025
Pay fees -Final grade and sod -pending driveway inspection -splash blocks and sump pump discharge to extend 36” from foundation -all outlets in unfinished spaces must be gfci protected or single receptacle outlet (see garage) -water meter to be 14”-18” from top of meter to well ring lid
Occupancy Inspection - Codes Residential Ready for Temp CO 3/18/2025 3/18/2025 03/18/2025
Misc
Corrective Action Required
03/14/2025
Pay fees -Final grade and sod -pending driveway inspection -splash blocks and sump pump discharge to extend 36” from foundation -water meter to be 14”-18” from top of meter to well ring lid
Occupancy Inspection - Codes Residential Ready for Temp CO 4/17/2025 04/17/2025
Misc
Corrective Action Required
03/18/2025
permit extenion request approved for another 30 days. Mitchell Schwarz 04/17/2025 7:25 AM Pay fees -Final grade and sod -pending driveway inspection -splash blocks and sump pump discharge to extend 36” from foundation -water meter to be 14”-18” from top of meter to well ring lid
Occupancy Inspection - Codes Residential Ready for Temp CO 5/21/2025 05/21/2025
Misc
Corrective Action Required
04/17/2025
permit extenion request approved for another 30 days. Mitchell Schwarz 04/17/2025 7:25 AM Pay fees -Final grade and sod -pending driveway inspection -splash blocks and sump pump discharge to extend 36” from foundation -water meter to be 14”-18” from top of meter to well ring lid
Occupancy Inspection - Codes Residential Full C of O 10/13/2025 10/13/2025 10/13/2025
Misc
Resolved
10/13/2025
permit extenion request approved for another 30 days. Mitchell Schwarz 04/17/2025 7:25 AM
Documents & Images
Date Uploaded File Type Document Name
08/27/2024 HT #81 - PERMIT APP
09/03/2024 Permit Codes Residential Plan Review
09/03/2024 Plot Plan APPROVED PLOT PLAN
09/04/2024 RESPONSE LETTER - 240904
09/05/2024 Approved Plans APPROVED PLANS
09/10/2024 Approved Plans APPROVED TRUSS LAYOUT
09/10/2024 Approved Plans APPROVED TRUSS PACKAGE
09/10/2024 Permit Codes Residential Plan Review
09/10/2024 Permit DS Building Permit
09/10/2024 Receipt Receipt for transaction:2024-007589
10/01/2024 1535 SW Arbor Valley Dr LSMO Footing Inspection Report
10/03/2024 Letter INSPECTION SUMMARY
10/29/2024 Letter INSPECTION SUMMARY
10/29/2024 Letter INSPECTION SUMMARY
10/31/2024 Letter INSPECTION SUMMARY
11/01/2024 Letter INSPECTION SUMMARY
11/01/2024 Letter INSPECTION SUMMARY
11/01/2024 Letter INSPECTION SUMMARY
11/04/2024 Letter INSPECTION SUMMARY
11/05/2024 Letter INSPECTION SUMMARY
12/10/2024 Letter INSPECTION SUMMARY
01/08/2025 Letter INSPECTION SUMMARY
01/08/2025 Letter INSPECTION SUMMARY
01/08/2025 Letter INSPECTION SUMMARY
01/10/2025 Letter INSPECTION SUMMARY
01/15/2025 Letter INSPECTION SUMMARY
02/27/2025 Letter INSPECTION SUMMARY
02/27/2025 Letter INSPECTION SUMMARY
03/04/2025 Letter INSPECTION SUMMARY
03/06/2025 Letter INSPECTION SUMMARY
03/11/2025 Letter INSPECTION SUMMARY
03/14/2025 Letter INSPECTION SUMMARY
03/17/2025 Receipt Receipt for transaction:2025-001598
03/18/2025 Letter INSPECTION SUMMARY
03/18/2025 Certificate/License Codes Temporary Certificate of Occupancy
03/18/2025 Receipt Receipt for transaction:2025-001634
04/08/2025 HT #81 - TCO Extension 4_8_25
04/21/2025 Certificate/License Codes Temporary Certificate of Occupancy
04/21/2025 Receipt Receipt for transaction:2025-002473
04/21/2025 Application Form TCO EXTENSION REQUEST
05/12/2025 Application Form TCO EXTENSION REQUEST
05/21/2025 Letter INSPECTION SUMMARY
10/08/2025 Letter Codes 140 Day Letter
10/08/2025 Letter INSPECTION SUMMARY
10/09/2025 Certificate/License Codes Temporary Certificate of Occupancy
10/09/2025 Certificate/License Codes Temporary Certificate of Occupancy
10/09/2025 Certificate/License Codes Temporary Certificate of Occupancy
10/09/2025 Certificate/License Codes Temporary Certificate of Occupancy
10/09/2025 Certificate/License Codes Temporary Certificate of Occupancy
10/09/2025 Receipt Receipt for transaction:2025-007666
10/13/2025 Letter Field Certificate of Occupancy
10/13/2025 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home