Summary
PRRES20242665
Building Permit - Residential
Issued
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - ROOF TRUSSES - STOP WORK ORDER generated on 10/09/2024 12:00 AM by username 'Kyle Beard'. STOP WORK ORDER removed on 10/11/2024 12:00 AM by username 'Kyle Beard'. STOP WORK ORDER generated on 07/18/2025 12:00 AM by username 'Jamie Simerly'. STOP WORK ORDER removed on 08/22/2025 12:00 AM by username 'Jamie Simerly'.
05/24/2024
06/06/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
BRUCER@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 06/06/2024
Right of Way Permit Fee $85.00 $85.00 Paid 06/06/2024
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 06/06/2024
Water Tap Fee $3,760.00 $3,760.00 Paid 06/06/2024
Water Meter Fee $680.46 $680.46 Paid 06/06/2024
Valuation Fee New Single Family $1,403.23 $1,403.23 Paid 06/06/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 12/04/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 12/04/2024
3rd and Subsequent Inspection Fee (Per Hour) $75.00 $75.00 Paid 12/04/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 12/19/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 12/19/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 12/19/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 01/17/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 02/07/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 03/03/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Plot Plan Inspection Pending
Miscellaneous Correction
Corrective Action Required
12/17/2024
North side of property does not have its final grade so the plot plan inspection failed
Occupancy Inspection - Codes Residential Pending
Miscellaneous Correction
Corrective Action Required
04/02/2025
Sod and splash pads are not installed Plot plan must pass Sidewalk final still needs to pass
Misc
Corrective Action Required
04/02/2025
TCO Expires Today
Sidewalk Inspection Pending
Misc
Corrective Action Required
06/16/2025
10-13-24 Dustin A, SW in front has been poured to city specs, still needs sw on north side 6-16-25 Dustin A, Last section is formed and compacted and slopes are in compliance at this time, approved to pour
Erosion Control Inspection Residential Pending
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
08/22/2025
5/13/25 EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -Install erosion control methods at perimeter, properly protect storm inlet
Erosion Control Inspection Residential Failed 7/3/2024 07/03/2024
Miscellaneous Correction
Corrective Action Required
07/03/2024
Gravel in the street needs to be removed Full erosion control measures must be in place and maintained until CofO
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
07/03/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Remove gravel in the streets
Footing Inspection - Residential Failed 7/3/2024 07/03/2024
Miscellaneous Correction
Corrective Action Required
07/03/2024
Inspection denied until mud and gravel in the streets are cleaned up. Full erosion control measures must be maintained until CofO
Sewer Service Inspection - R Passed 7/10/2024 7/10/2024 07/10/2024
Erosion Control Inspection Residential Partial 7/10/2024 07/10/2024
Miscellaneous Correction
Resolved
07/10/2024
Gravel in the street needs to be removed Full erosion control measures must be in place and maintained until CofO
Miscellaneous Correction
Informational
07/10/2024
Full erosion control is in place and must be maintained until CofO
Water Service Inspection - R Partial 7/11/2024 07/11/2024
Miscellaneous Correction
Informational
07/11/2024
PEX ran out 20 feet from the foundation Okay to cover This is a partial pass only
Water Service Inspection - R Partial 7/12/2024 07/12/2024
Miscellaneous Correction
Informational
07/11/2024
-PEX ran out 20 feet from the foundation -10 feet of copper connecting to the PEX has also been inspected Okay to cover This is a partial pass only
Water Service Inspection - R Passed 7/15/2024 07/15/2024
Miscellaneous Correction
Resolved
07/15/2024
-PEX ran out 20 feet from the foundation -10 feet of copper connecting to the PEX has also been inspected Okay to cover This is a partial pass only
Underslab Plumbing Inspection - Residential Failed 7/22/2024 7/22/2024 07/22/2024
Miscellaneous Correction
Corrective Action Required
07/22/2024
Remove decaying wood forms from foundation
Erosion Control Inspection Residential Partial 7/22/2024 07/22/2024
Miscellaneous Correction
Resolved
07/22/2024
Full erosion control is in place and must be maintained until CofO
Miscellaneous Correction
Informational
07/22/2024
Full erosion control measures are in place and must be maintained until CofO
Underslab Plumbing Inspection - Residential Passed 7/23/2024 7/23/2024 07/23/2024
Miscellaneous Correction
Resolved
07/23/2024
Erosion Control Inspection Residential Failed 8/13/2024 08/13/2024
Miscellaneous Correction
Resolved
08/13/2024
Full erosion control measures are in place and must be maintained until CofO
Miscellaneous Correction
Corrective Action Required
08/13/2024
Erosion control along the North side is damaged and no longer meets its intended purpose. Repair or replace erosion control on North side of property Full erosion control measures must be maintained until CofO
Erosion Control Inspection Residential Failed 9/11/2024 09/11/2024
Miscellaneous Correction
Corrective Action Required
08/13/2024
Erosion control along the North side is damaged and no longer meets its intended purpose. Repair or replace erosion control on North side of property Full erosion control measures must be maintained until CofO Second notice. Third failed inspection will result in a stop work order being issued
Footing Inspection - Residential Passed 9/16/2024 09/16/2024
Miscellaneous Correction
Resolved
09/16/2024
Inspection denied until mud and gravel in the streets are cleaned up. Full erosion control measures must be maintained until CofO
Miscellaneous Correction
Resolved
09/16/2024
Footing was passed by a third party. Exterior piers were not mentioned in the footing report
All Rough Inspection - Residential Failed 9/16/2024 9/16/2024 09/16/2024
Miscellaneous Correction
Corrective Action Required
09/16/2024
Inspection denied until erosion control passes and trash on the property is cleaned up This is the last warning before a stop work order is issued
Erosion Control Inspection Residential Failed - Stop Work 10/9/2024 10/09/2024
Miscellaneous Correction
Resolved
10/09/2024
Erosion control along the North side is damaged and no longer meets its intended purpose. Repair or replace erosion control on North side of property Full erosion control measures must be maintained until CofO Second notice. Third failed inspection will result in a stop work order being issued
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
10/09/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Erosion control along the North side is damaged and no longer meets its intended purpose. Repair or replace erosion control on North side of property Full erosion control measures must be maintained until CofO Second notice. Third failed inspection will result in a stop work order being issued Stop work order is issued as of this day 10/09/2024. KBEARD
Erosion Control Inspection Residential Partial 10/11/2024 10/11/2024 10/11/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
10/11/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Erosion control along the North side is damaged and no longer meets its intended purpose. Repair or replace erosion control on North side of property Full erosion control measures must be maintained until CofO Second notice. Third failed inspection will result in a stop work order being issued Stop work order is issued as of this day 10/09/2024. KBEARD
Miscellaneous Correction
Informational
10/11/2024
Full erosion control measures are in place and must be properly maintained until CofO
Erosion Control Inspection Residential Partial 10/14/2024 10/14/2024
Miscellaneous Correction
Informational
10/11/2024
Full erosion control measures are in place and must be properly maintained until CofO
All Rough Inspection - Residential Not Ready 10/9/2024 10/14/2024 10/14/2024
Miscellaneous Correction
Resolved
10/14/2024
Inspection denied until erosion control passes and trash on the property is cleaned up This is the last warning before a stop work order is issued
Miscellaneous Correction
Corrective Action Required
10/14/2024
House plans are not on site for inspection Not ready
Gas Service Inspection - Residential Passed 10/15/2024 10/15/2024
Electrical Service Inspection Passed 10/14/2024 10/15/2024 10/15/2024
All Rough Inspection - Residential Failed 10/15/2024 10/15/2024 10/15/2024
Miscellaneous Correction
Resolved
10/15/2024
House plans are not on site for inspection Not ready
Miscellaneous Correction
Corrective Action Required
10/15/2024
3804 SW Ravengate. All rough Garage header jack studs have been over cut to allow electrical wire Electrical nail plate at garage header jack stud has fallen Garage south foundation wall sole plate anchor bolts need to be in the center 1/3 of plate Snow block step flashing at front gable H2.5A bracket is missing in closet 3 H2.5A brackets at front porch could not be verified because of being covered Patio door header to king stud has a 1/2 inch gap Stair stringer beam in basement to intermediate platform does not bear 1 1/2 inches to double 2x10 beam Vertically support electrical wires to code between basement HVAC unit Basement water valve needs to be anti siphon
All Rough Inspection - Residential Failed 10/18/2024 10/18/2024 10/18/2024
Miscellaneous Correction
Resolved
10/18/2024
3804 SW Ravengate. All rough Garage header jack studs have been over cut to allow electrical wire Electrical nail plate at garage header jack stud has fallen Garage south foundation wall sole plate anchor bolts need to be in the center 1/3 of plate Snow block step flashing at front gable H2.5A bracket is missing in closet 3 H2.5A brackets at front porch could not be verified because of being covered Patio door header to king stud has a 1/2 inch gap Stair stringer beam in basement to intermediate platform does not bear 1 1/2 inches to double 2x10 beam Vertically support electrical wires to code between basement HVAC unit Basement water valve needs to be anti siphon
Miscellaneous Correction
Corrective Action Required
10/18/2024
3804 SW Ravengate. All rough (2) -Garage header jack studs have been over cut to allow electrical (electrical is now outside the stud space) -Patio door header to king stud has a 1/2 inch gap (caulking does not have structure strength) -Vertically support electrical wires to code between basement HVAC unit (not completed)
Erosion Control Inspection Residential Partial 10/18/2024 10/18/2024
Miscellaneous Correction
Informational
10/14/2024
Full erosion control measures are in place and must be properly maintained until CofO
All Rough Inspection - Residential Not Ready 10/21/2024 10/21/2024 10/21/2024
Miscellaneous Correction
Resolved
10/21/2024
3804 SW Ravengate. All rough (2) -Garage header jack studs have been over cut to allow electrical (electrical is now outside the stud space) -Patio door header to king stud has a 1/2 inch gap (caulking does not have structure strength) -Vertically support electrical wires to code between basement HVAC unit (not completed)
Miscellaneous Correction
Corrective Action Required
10/21/2024
3804 SW Ravengate. All rough (3) Garage header jack studs have been over cut to allow electrical (electrical is now outside the stud space) Patio door header to king stud has a 1/2 inch gap (caulking does not have structure strength) Vertically support electrical wires to code between basement HVAC unit (not completed) Walk your property before scheduling inspections Not ready for inspection
All Rough Inspection - Residential Failed 10/23/2024 10/23/2024 10/23/2024
Miscellaneous Correction
Resolved
10/23/2024
3804 SW Ravengate. All rough (3) Garage header jack studs have been over cut to allow electrical (electrical is now outside the stud space) Patio door header to king stud has a 1/2 inch gap (caulking does not have structure strength) Vertically support electrical wires to code between basement HVAC unit (not completed) Walk your property before scheduling inspections Not ready for inspection
Miscellaneous Correction
Corrective Action Required
10/23/2024
3804 SW Ravengate. All rough (4) Vertically support electrical wires to code between HVAC unit in basement at floor joist above unit (not completed) Walk your property before scheduling inspections
All Rough Inspection - Residential Passed 10/24/2024 10/24/2024 10/24/2024
Miscellaneous Correction
Resolved
10/24/2024
3804 SW Ravengate. All rough (4) Vertically support electrical wires to code between HVAC unit in basement at floor joist above unit (not completed) Walk your property before scheduling inspections
Erosion Control Inspection Residential Failed 11/1/2024 11/01/2024
Miscellaneous Correction
Resolved
11/01/2024
Full erosion control measures are in place and must be properly maintained until CofO
Miscellaneous Correction
Corrective Action Required
11/01/2024
Repair or replace damaged or missing silt fence or waddle on north side of property Full erosion control measures must be in place and properly maintained until CofO
Erosion Control Inspection Residential Failed 11/1/2024 11/1/2024 11/01/2024
Miscellaneous Correction
Corrective Action Required
11/01/2024
Repair or replace damaged or missing silt fence or waddle on north side of property Full erosion control measures must be in place and properly maintained until CofO
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
11/01/2024
11-1-24 Dustin A, Clean road of gravel and mud. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Partial 11/5/2024 11/5/2024 11/05/2024
Miscellaneous Correction
Corrective Action Required
11/01/2024
Repair or replace damaged or missing silt fence or waddle on north side of property Full erosion control measures must be in place and properly maintained until CofO
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
11/01/2024
11-1-24 Dustin A, Clean road of gravel and mud. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 11-5-24 Dustin A. road cleaned
Driveway Inspection Partial 11/6/2024 11/6/2024 11/06/2024
Misc
Informational
11/06/2024
11-6-24 Dustin A, Dw is formed and compacted. Approved to pour
Sidewalk Inspection Partial 11/14/2024 11/14/2024 11/14/2024
Misc
Corrective Action Required
11/14/2024
10-13-24 Dustin A, SW in front has been poured to city specs, still needs sw on north side
Driveway Inspection Passed 11/14/2024 11/14/2024 11/14/2024
Misc
Informational
11/06/2024
11-6-24 Dustin A, Dw is formed and compacted. Approved to pour 10-13-24 Dustin A, Dw is poured to city specs. Slopes are in compliance. Pass
Occupancy Inspection - Codes Residential Not Ready 12/12/2024 12/12/2024 12/12/2024
Misc
Corrective Action Required
12/12/2024
Not ready for a final occupancy inspection - water heater not wired, missing handrail, no backsplash, master shower incomplete( no tile or fixtures, open electrical boxes in basement ceiling. Please walk your houses before scheduling for a Final , Not Ready fee assessed.
Occupancy Inspection - Codes Residential Not Ready 12/17/2024 12/17/2024 12/17/2024
Misc
Resolved
12/17/2024
Not ready for a final occupancy inspection - water heater not wired, missing handrail, no backsplash, master shower incomplete( no tile or fixtures, open electrical boxes in basement ceiling. Please walk your houses before scheduling for a Final , Not Ready fee assessed.
Miscellaneous Correction
Corrective Action Required
12/17/2024
Stove is not installed to check anti tip over bracket Master shower is incomplete (missing fixtures) Fire block gaps in sheet rock above overhead garage doors Open junction box in basement by HVAC unit Electrical panel is missing a breaker or a blank plate Bottom hand rail is still not installed Seal gas line penetration at siding Exterior electrical receptacle by A/C unit is not GFCI protected Sod and splash pads are not installed Plot plan must pass Sidewalk final still needs to pass Pay $150 in permit fees Please walk your property before scheduling your inspections $75 not ready fee added because of handrail was still not installed
Plot Plan Inspection Failed 12/17/2024 12/17/2024
Miscellaneous Correction
Corrective Action Required
12/17/2024
North side of property does not have its final grade so the plot plan inspection failed
Erosion Control Inspection Residential Partial 12/17/2024 12/17/2024
Miscellaneous Correction
Resolved
12/17/2024
Repair or replace damaged or missing silt fence or waddle on north side of property Full erosion control measures must be in place and properly maintained until CofO
DCM3 ESC REQUIRED 2 DAY
Resolved
12/17/2024
11-1-24 Dustin A, Clean road of gravel and mud. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 11-5-24 Dustin A. road cleaned
Miscellaneous Correction
Informational
12/17/2024
Erosion control is in place at the time of inspection
Occupancy Inspection - Codes Residential Ready for Temp CO 12/19/2024 12/19/2024 12/19/2024
Miscellaneous Correction
Resolved
12/19/2024
Stove is not installed to check anti tip over bracket Master shower is incomplete (missing fixtures) Fire block gaps in sheet rock above overhead garage doors Open junction box in basement by HVAC unit Electrical panel is missing a breaker or a blank plate Bottom hand rail is still not installed Seal gas line penetration at siding Exterior electrical receptacle by A/C unit is not GFCI protected Sod and splash pads are not installed Plot plan must pass Sidewalk final still needs to pass Pay $150 in permit fees Please walk your property before scheduling your inspections $75 not ready fee added because of handrail was still not installed
Miscellaneous Correction
Corrective Action Required
12/19/2024
Sod and splash pads are not installed Plot plan must pass Sidewalk final still needs to pass Pay $150 in permit fees Passed for TCO only
Occupancy Inspection - Codes Residential Ready for Temp CO 1/17/2025 01/17/2025
Miscellaneous Correction
Resolved
01/17/2025
Sod and splash pads are not installed Plot plan must pass Sidewalk final still needs to pass Passed for TCO only
Miscellaneous Correction
Corrective Action Required
01/17/2025
Sod and splash pads are not installed Plot plan must pass Sidewalk final still needs to pass TCO extension form sent in by builder Passed for TCO only
Occupancy Inspection - Codes Residential Ready for Temp CO 2/7/2025 02/07/2025
Miscellaneous Correction
Resolved
02/07/2025
Sod and splash pads are not installed Plot plan must pass Sidewalk final still needs to pass TCO extension form sent in by builder Passed for TCO only
Miscellaneous Correction
Corrective Action Required
02/07/2025
Sod and splash pads are not installed Plot plan must pass Sidewalk final still needs to pass TCO extension form sent in by builder Passed for TCO only
Occupancy Inspection - Codes Residential Ready for Temp CO 3/3/2025 03/03/2025
Miscellaneous Correction
Resolved
03/03/2025
Sod and splash pads are not installed Plot plan must pass Sidewalk final still needs to pass TCO extension form sent in by builder Passed for TCO only
Miscellaneous Correction
Corrective Action Required
03/03/2025
Sod and splash pads are not installed Plot plan must pass Sidewalk final still needs to pass TCO extension form sent in by builder Passed for TCO only 02/93/25. KBEARD
Occupancy Inspection - Codes Residential Failed 4/2/2025 04/02/2025
Miscellaneous Correction
Corrective Action Required
03/03/2025
Sod and splash pads are not installed Plot plan must pass Sidewalk final still needs to pass
Misc
Corrective Action Required
04/02/2025
TCO Expires Today
Erosion Control Inspection Residential Failed 05/13/2025
Miscellaneous Correction
Resolved
05/13/2025
Erosion control is in place at the time of inspection
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
05/13/2025
5/13/25 EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -Install erosion control methods at perimeter, properly protect storm inlet
Sidewalk Inspection Partial 6/16/2025 6/16/2025 06/16/2025
Misc
Corrective Action Required
11/14/2024
10-13-24 Dustin A, SW in front has been poured to city specs, still needs sw on north side 6-16-25 Dustin A, Last section is formed and compacted and slopes are in compliance at this time, approved to pour
Erosion Control Inspection Residential Failed 7/15/2025 7/15/2025 07/15/2025
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
05/13/2025
5/13/25 EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -Install erosion control methods at perimeter, properly protect storm inlet
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
07/15/2025
07/15/25 Jamie S, Erosion control needs to be reestablished. Erosion control needs to be added to front right corner of yard as well due to soil going over sidewalk and driveway. All of the sidewalk needs to be cleaned off and free of debris to prevent safety hazards. Silt socks in front of storm drains on both Ravengate Pl and Osage Dr need to be cleaned out. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Failed - Stop Work 7/18/2025 7/18/2025 07/18/2025
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
07/15/2025
5/13/25 EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -Install erosion control methods at perimeter, properly protect storm inlet
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
07/15/2025
07/15/25 Jamie S, Erosion control needs to be reestablished. Erosion control needs to be added to front right corner of yard as well due to soil going over sidewalk and driveway. All of the sidewalk needs to be cleaned off and free of debris to prevent safety hazards. Silt socks in front of storm drains on both Ravengate Pl and Osage Dr need to be cleaned out. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 07/18/25 Jamie S, Erosion control needs to be reestablished. Erosion control needs to be added to front right corner of yard as well due to soil going over sidewalk and driveway. All of the sidewalk needs to be cleaned off and free of debris to prevent safety hazards. Silt socks in front of storm drains on both Ravengate Pl and Osage Dr need to be cleaned out.
Erosion Control Inspection Residential Partial 8/22/2025 8/22/2025 08/22/2025
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
07/18/2025
5/13/25 EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -Install erosion control methods at perimeter, properly protect storm inlet
DCM3 ESC REQUIRED 2 DAY
Resolved
08/22/2025
07/15/25 Jamie S, Erosion control needs to be reestablished. Erosion control needs to be added to front right corner of yard as well due to soil going over sidewalk and driveway. All of the sidewalk needs to be cleaned off and free of debris to prevent safety hazards. Silt socks in front of storm drains on both Ravengate Pl and Osage Dr need to be cleaned out. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 07/18/25 Jamie S, Erosion control needs to be reestablished. Erosion control needs to be added to front right corner of yard as well due to soil going over sidewalk and driveway. All of the sidewalk needs to be cleaned off and free of debris to prevent safety hazards. Silt socks in front of storm drains on both Ravengate Pl and Osage Dr need to be cleaned out.
Documents & Images
Date Uploaded File Type Document Name
05/24/2024 OS #60 - ENGINEERED PLANS
05/24/2024 OS #60 - PERMIT APP
05/24/2024 OS #60 - PLOT PLAN
05/24/2024 OS #60 - TRUSS DETAILS
05/24/2024 OS #60 - TRUSS LAYOUT
06/05/2024 Approved Plans APPROVED PLANS
06/05/2024 Plot Plan APPROVED PLOT PLAN
06/05/2024 Approved Plans APPROVED TRUSS LAYOUT
06/05/2024 Approved Plans APPROVED TRUSS PACKAGE
06/05/2024 Permit Codes Residential Plan Review
06/06/2024 Permit DS Building Permit
06/06/2024 Receipt Receipt for transaction:2024-004434
07/03/2024 3RD Party Insp Report THIRD PARTY FOOTING INSPECTION
07/03/2024 Letter INSPECTION SUMMARY
07/03/2024 Letter INSPECTION SUMMARY
07/10/2024 Letter INSPECTION SUMMARY
07/10/2024 Letter INSPECTION SUMMARY
07/11/2024 Letter INSPECTION SUMMARY
07/12/2024 Letter INSPECTION SUMMARY
07/15/2024 Letter INSPECTION SUMMARY
07/22/2024 Letter INSPECTION SUMMARY
07/22/2024 Letter INSPECTION SUMMARY
07/23/2024 Letter INSPECTION SUMMARY
08/13/2024 Letter INSPECTION SUMMARY
09/11/2024 Letter INSPECTION SUMMARY
09/16/2024 Letter INSPECTION SUMMARY
09/16/2024 Letter INSPECTION SUMMARY
09/16/2024 Letter INSPECTION SUMMARY
10/09/2024 Letter Stop Work Order
10/11/2024 Letter INSPECTION SUMMARY
10/14/2024 Letter INSPECTION SUMMARY
10/14/2024 Letter INSPECTION SUMMARY
10/15/2024 Letter INSPECTION SUMMARY
10/15/2024 Letter INSPECTION SUMMARY
10/18/2024 Letter INSPECTION SUMMARY
10/18/2024 Letter INSPECTION SUMMARY
10/18/2024 Letter INSPECTION SUMMARY
10/21/2024 Letter INSPECTION SUMMARY
10/23/2024 Letter INSPECTION SUMMARY
10/24/2024 Letter INSPECTION SUMMARY
11/01/2024 Letter INSPECTION SUMMARY
11/01/2024 Letter INSPECTION SUMMARY
11/01/2024 Letter INSPECTION SUMMARY
11/05/2024 Letter INSPECTION SUMMARY
11/06/2024 Letter INSPECTION SUMMARY
11/14/2024 Letter INSPECTION SUMMARY
11/14/2024 Letter INSPECTION SUMMARY
12/04/2024 Receipt Receipt for transaction:2024-009317
12/12/2024 Letter INSPECTION SUMMARY
12/17/2024 Letter INSPECTION SUMMARY
12/17/2024 Letter INSPECTION SUMMARY
12/17/2024 Letter INSPECTION SUMMARY
12/19/2024 Letter INSPECTION SUMMARY
12/19/2024 Certificate/License Codes Temporary Certificate of Occupancy
12/19/2024 Receipt Receipt for transaction:2024-009594
01/08/2025 OS #60 - TCO Extension 1_8_25
01/17/2025 Letter INSPECTION SUMMARY
01/17/2025 Certificate/License Codes Temporary Certificate of Occupancy
01/17/2025 Receipt Receipt for transaction:2025-000298
02/06/2025 Application Form OS #60 - TCO Extension 2_6_25
02/07/2025 Letter INSPECTION SUMMARY
02/07/2025 Certificate/License Codes Temporary Certificate of Occupancy
02/07/2025 Receipt Receipt for transaction:2025-000818
02/27/2025 OS #60 - TCO Extension 2_27_25
03/03/2025 Letter INSPECTION SUMMARY
03/03/2025 Certificate/License Codes Temporary Certificate of Occupancy
03/03/2025 Receipt Receipt for transaction:2025-001236
04/02/2025 Letter Codes 10 Day Letter
04/03/2025 OS #62 - TCO Extension 3_19_25
05/13/2025 Letter INSPECTION SUMMARY
06/16/2025 Letter INSPECTION SUMMARY
07/15/2025 Letter INSPECTION SUMMARY
07/18/2025 Letter Stop Work Order
08/22/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home