PRRES20242357
Building Permit - Residential
Certificate of Occupancy
DOMAIN TIMBERLAKE MULTISTATE LLC
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - COVERED DECK - UNFINISHED BASEMENT STOP WORK ORDER generated on 06/04/2024 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 06/06/2024 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER generated on 10/17/2024 12:00 AM by username 'Dustin Agcopra'. STOP WORK ORDER removed on 11/13/2024 12:00 AM by username 'Kyle Beard'.
05/10/2024
05/15/2024
04/07/2025
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
DOMAIN TIMBERLAKE MULTISTATE LLC, Address:590 MADISON AVE FL 13TH  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
BRUCER@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 05/15/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 05/15/2024
7232302-Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 05/15/2024
8331401-Water Tap Fee $3,760.00 $3,760.00 Paid 05/15/2024
8350015-Water Meter Fee $680.46 $680.46 Paid 05/15/2024
9110078-Valuation Fee New Single Family $1,385.73 $1,385.73 Paid 05/15/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 11/14/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 11/14/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 11/14/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 03/13/2025
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 03/13/2025
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 03/13/2025
Outstanding Fees Amount Paid Owing Date Paid


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 5/24/2024 5/24/2024 05/24/2024
Misc
Corrective Action Required
05/24/2024
Ufer ground rod identified in report in wrong location. Please revise.
Sewer Service Inspection - R Passed 6/4/2024 06/04/2024
Footing Inspection - Residential Failed - Stop Work 6/4/2024 06/04/2024
Misc
Corrective Action Required
05/24/2024
Ufer ground rod identified in report in wrong location. Please revise. No revision
Footing Inspection - Residential Passed 6/6/2024 06/06/2024
Misc
Resolved
06/06/2024
Ufer ground rod identified in report in wrong location. Please revise. No revision
Water Service Inspection - R Passed 6/6/2024 06/06/2024
Underslab Plumbing Inspection - Residential Passed 6/12/2024 6/12/2024 06/12/2024
All Rough Inspection - Residential Failed 7/23/2024 7/23/2024 07/23/2024
Misc
Informational
07/23/2024
Garage portal frame inspected only okay to cover
Misc
Corrective Action Required
07/23/2024
-no plans on site to check covered front porch -trusses on front porch missing hold downs
All Rough Inspection - Residential Not Ready 8/13/2024 8/13/2024 08/13/2024
Misc
Informational
07/23/2024
Garage portal frame inspected only okay to cover
Misc
Corrective Action Required
07/23/2024
-no plans on site to check covered front porch -trusses on front porch missing hold downs
Misc
Corrective Action Required
08/13/2024
No fireblocking done throughout, home Not ready for inspection
Electrical Service Inspection Passed 8/13/2024 8/13/2024 08/13/2024
Gas Service Inspection - Residential Not Ready 8/13/2024 8/13/2024 08/13/2024
Misc
Corrective Action Required
08/13/2024
Gas line not installed
All Rough Inspection - Residential Failed 8/21/2024 8/21/2024 08/21/2024
Misc
Resolved
08/21/2024
Garage portal frame inspected only okay to cover
Misc
Resolved
08/21/2024
-no plans on site to check covered front porch -trusses on front porch missing hold downs
Misc
Resolved
08/21/2024
No fireblocking done throughout, home Not ready for inspection
Misc
Corrective Action Required
08/21/2024
Uncover front and rear porch to inspect hold downs -missing nails in lib bracing in garage -seal bottom plate penetration at stairs to basement -strap top plate where lapped less than 24” walk in closet -truss C4 missing lateral bracing -anchor bolts to be in the middle 1/3 of sill plate -anchor bolts to be within 12” of plate breaks, not closer than 7x the diameter of the bolt -naill all exterior sheathing to plans
All Rough Inspection - Residential Failed 8/28/2024 8/28/2024 08/28/2024
Misc
Corrective Action Required
08/21/2024
Uncover front and rear porch to inspect hold downs (can not see hold downs) -seal bottom plate penetration at stairs to basement -truss C4 missing lateral bracing
Gas Service Inspection - Residential Failed 8/28/2024 8/28/2024 08/28/2024
Misc
Corrective Action Required
08/13/2024
Use approved test gaguge in accordance with G2417.4 of the IRC
Gas Service Inspection - Residential Passed 8/30/2024 8/30/2024 08/30/2024
Misc
Resolved
08/30/2024
Use approved test gaguge in accordance with G2417.4 of the IRC
All Rough Inspection - Residential Passed 8/30/2024 8/30/2024 08/30/2024
Misc
Resolved
08/30/2024
Uncover front and rear porch to inspect hold downs (can not see hold downs) -seal bottom plate penetration at stairs to basement -truss C4 missing lateral bracing
Erosion Control Inspection Residential Failed 10/14/2024 10/14/2024 10/14/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
10/14/2024
10-14-24 Dustin A, Straw waddle has been damaged in some spots, need replaced, EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Driveway Inspection Partial 10/16/2024 10/16/2024 10/16/2024
Misc
Informational
10/16/2024
10-16-24 Dustin A, DW is formed and compacted, approved to pour.
Erosion Control Inspection Residential Failed - Stop Work 10/17/2024 10/17/2024 10/17/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
10/14/2024
10-14-24 Dustin A, Straw waddle has been damaged in some spots, need replaced, EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 10-17-24 Dustin A, has not been corrected
Occupancy Inspection - Codes Residential Failed 11/12/2024 11/12/2024 11/12/2024
Miscellaneous Correction
Corrective Action Required
11/12/2024
This property has a stop work order posted on the permit. Inspection is denied until stop work order is lifted Driveway has not passed inspection
Erosion Control Inspection Residential Partial 11/13/2024 11/13/2024 11/13/2024
DCM3 ESC REQUIRED 2 DAY
Resolved
11/13/2024
10-14-24 Dustin A, Straw waddle has been damaged in some spots, need replaced, EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 10-17-24 Dustin A, has not been corrected
Miscellaneous Correction
Informational
11/13/2024
Full erosion control measures are in place and must be properly maintained until CofO
Driveway Inspection Passed 11/13/2024 11/13/2024 11/13/2024
Misc
Informational
10/16/2024
10-16-24 Dustin A, DW is formed and compacted, approved to pour. 10-13-24 Dustin A, DW is poured to city specs. Passed
Occupancy Inspection - Codes Residential Failed 11/13/2024 11/14/2024 11/14/2024
Miscellaneous Correction
Resolved
11/14/2024
This property has a stop work order posted on the permit. Inspection is denied until stop work order is lifted Driveway has not passed inspection
Miscellaneous Correction
Corrective Action Required
11/14/2024
-Sod, splash pads and sump pump extension is not installed -As graded plot plan is required before sodding -seal all exterior penetrations -install missing joist hanger under deck -Install missing nails in joist hanger under deck -Install post to beam fasteners for deck Passed for TCO only
Occupancy Inspection - Codes Residential Full C of O 4/7/2025 4/7/2025 04/07/2025
Miscellaneous Correction
Resolved
04/07/2025
-Sod, splash pads and sump pump extension is not installed -As graded plot plan is required before sodding -seal all exterior penetrations Passed for TCO only
Documents & Images
Date Uploaded File Type Document Name
05/10/2024 HT #192 - ENGINEERED PLANS
05/10/2024 Application Form HT #192 - PERMIT APP
05/10/2024 HT #192 - PLOT PLAN
05/10/2024 HT #192 - TRUSS DETAILS
05/10/2024 HT #192 - TRUSS LAYOUT
05/13/2024 Approved Plans APPROVED PLANS
05/13/2024 Plot Plan APPROVED PLOT PLAN
05/13/2024 Approved Plans APPROVED TRUSS LAYOUT
05/13/2024 Approved Plans APPROVED TRUSS PACKAGE
05/13/2024 Permit Codes Residential Plan Review
05/15/2024 Permit DS Building Permit
05/15/2024 Receipt Receipt for transaction:2024-003506
05/22/2024 3RD Party Insp Report THIRD PARTY FOOTING INSPECTION
05/24/2024 Letter INSPECTION SUMMARY
06/04/2024 Letter INSPECTION SUMMARY
06/04/2024 Letter Stop Work Order
06/04/2024 Letter Stop Work Order
06/06/2024 Letter INSPECTION SUMMARY
06/06/2024 Letter INSPECTION SUMMARY
06/06/2024 Letter INSPECTION SUMMARY
06/12/2024 Letter INSPECTION SUMMARY
07/23/2024 Letter INSPECTION SUMMARY
08/13/2024 Letter INSPECTION SUMMARY
08/13/2024 Letter INSPECTION SUMMARY
08/13/2024 Letter INSPECTION SUMMARY
08/21/2024 Letter INSPECTION SUMMARY
08/28/2024 Letter INSPECTION SUMMARY
08/28/2024 Letter INSPECTION SUMMARY
08/30/2024 Letter INSPECTION SUMMARY
08/30/2024 Letter INSPECTION SUMMARY
10/14/2024 Letter INSPECTION SUMMARY
10/14/2024 Letter INSPECTION SUMMARY
10/16/2024 Letter INSPECTION SUMMARY
10/17/2024 Letter Stop Work Order
10/17/2024 Letter Stop Work Order
11/12/2024 Letter INSPECTION SUMMARY
11/13/2024 Letter INSPECTION SUMMARY
11/13/2024 Letter INSPECTION SUMMARY
11/14/2024 Receipt Receipt for transaction:2024-008951
11/14/2024 Letter INSPECTION SUMMARY
11/14/2024 Letter INSPECTION SUMMARY
11/14/2024 Letter INSPECTION SUMMARY
11/14/2024 Certificate/License Codes Temporary Certificate of Occupancy
11/14/2024 Receipt Receipt for transaction:2024-008956
12/04/2024 HT #192 - TCO extension 12_4_24
12/04/2024 HT #192 - TCO extension 12_4_24
03/10/2025 HT 192 ASBUILT
03/10/2025 Plot Plan APPROVED AS GRADED PLOT PLAN
03/13/2025 Certificate/License Codes Temporary Certificate of Occupancy
03/13/2025 Certificate/License Codes Temporary Certificate of Occupancy
03/13/2025 Certificate/License Codes Temporary Certificate of Occupancy
03/13/2025 Receipt Receipt for transaction:2025-001542
04/04/2025 Letter Codes 10 Day Letter
04/04/2025 Letter Codes 140 Day Letter
04/07/2025 Letter Field Certificate of Occupancy
04/07/2025 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home