Summary
PRRES20241618
Building Permit - Residential
Certificate of Occupancy
DJ23 INVESTMENTS LLC
NEW SINGLE FAMILY
NEW HOUSE - UNFINSIHED BASEMENT - COVERED PORCH
04/03/2024
04/18/2024
10/13/2024
11/15/2024
Locations
Contacts
Avital Homes, LLC, Address:7500 W 151st Street, #23100, Phone:(816) 914-7128  
Doug Jenson, Address:11010 Nora Dodge Dr, Phone:(816) 266-0685  
DJ23 INVESTMENTS LLC, Address:7200 W 132ND ST  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
CARUTHERS ELECTRICAL LLC, Address:30905 E TRUMAN RD, Phone:(816) 508-9050  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
DOUG@APGKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331401-Water Tap Fee $3,760.00 $3,760.00 Paid 04/18/2024
8350015-Water Meter Fee $680.46 $680.46 Paid 04/18/2024
8331507-Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 04/18/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 04/18/2024
7232302-Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 04/18/2024
9110078-Valuation Fee New Single Family $1,898.33 $1,898.33 Paid 04/18/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 10/17/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 11/14/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Partial 4/24/2024 04/24/2024
Miscellaneous Correction
Informational
04/24/2024
Full erosion control is in place and needs to be maintained until CofO
Footing Inspection - Residential Passed 4/24/2024 4/24/2024 04/24/2024
Miscellaneous Correction
Informational
04/24/2024
Ufer is located along garage south wall
Sewer Service Inspection - R Passed 5/14/2024 (1:00) 5/14/2024 05/14/2024
Underslab Plumbing Inspection - Residential Passed 5/15/2024 5/15/2024 05/15/2024
Erosion Control Inspection Residential Partial 5/15/2024 05/15/2024
Miscellaneous Correction
Resolved
05/15/2024
Full erosion control is in place and needs to be maintained until CofO
Miscellaneous Correction
Informational
05/15/2024
Full erosion control is in place and must be maintained until CofO
Water Service Inspection - R Partial 5/15/2024 5/15/2024 05/15/2024
Miscellaneous Correction
Informational
05/15/2024
PEX has been installed from the foundation to about 20 feet out towards the street. This is a partial pass only and is okay to cover
Water Service Inspection - R Passed 5/16/2024 5/16/2024 05/16/2024
Miscellaneous Correction
Resolved
05/16/2024
PEX has been installed from the foundation to about 20 feet out towards the street. This is a partial pass only and is okay to cover
Erosion Control Inspection Residential Partial 6/4/2024 06/04/2024
Miscellaneous Correction
Informational
05/15/2024
Full erosion control is in place and must be maintained until CofO
Erosion Control Inspection Residential Partial 06/10/2024
Miscellaneous Correction
Informational
06/04/2024
Full erosion control is in place and must be maintained until CofO
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/10/2024
6-10-24 Dustin A, EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Street needs to be cleaned
Erosion Control Inspection Residential Passed 6/13/2024 6/13/2024 06/12/2024
Miscellaneous Correction
Informational
06/10/2024
Full erosion control is in place and must be maintained until CofO
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/10/2024
6-10-24 Dustin A, EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Street needs to be cleaned 6-12-24 Dustin A, Street was cleaned up and erosion control up
All Rough Inspection - Residential Failed 6/14/2024 6/14/2024 06/14/2024
Misc
Informational
06/14/2024
This was a portal frame only inspection. Passed 6/14/24 AF
Piers/Caissons Inspection - Residential Passed 6/27/2024 06/27/2024
Miscellaneous Correction
Informational
06/27/2024
2 back porch post piers were dug and passed
Electrical Service Inspection Passed 7/17/2024 7/17/2024 07/17/2024
Gas Service Inspection - Residential Passed 7/17/2024 7/17/2024 07/17/2024
Erosion Control Inspection Residential Partial 7/17/2024 07/17/2024
Miscellaneous Correction
Informational
07/17/2024
Full erosion control measures are in place and must be maintained until CofO
All Rough Inspection - Residential Failed 7/17/2024 7/17/2024 07/17/2024
Misc
Informational
06/14/2024
This was a portal frame only inspection. Passed 6/14/24 AF
Miscellaneous Correction
Corrective Action Required
07/17/2024
1801 SW Hightown. All rough •Tightened garage anchor bolt west wall •Steel support post in garage can not be confirmed at 3.5 inches •Truss screw is missing along the exterior garage wall between large and small overhead door •Garage anchor bolts must be in the middle 1/3 of sole plate •Fire block top of chase in garage to main entry •Garage drop down ceiling needs to be supported (span is 9 feet wide) •Supply vent duct in garage needs to be supported every 10 feet •Supply vent in pantry ceiling needs to be supported every 10 feet on center •Tub above pantry needs double floor joist in •Fire block hole in floor above pantry for tub •Nail guards are needed in sole plate for water lines at living room to bath 4 •Fire blocking above closet 5 is broken out •Plumbing chase of bedroom 5 needs to be fire blocked at •Roof boot jackets is not installed •Fire block holes in top plate in primary bedroom N/W corner •Install different tie down in truss broken at the top plate in primary bedroom west wall •Fire block top of chase between the hallway and vanity •Truss tie down screws are missing above tub of bathroom 4 •Hole in top place in bedroom 4 •Double floor joist are required on all floors below tubs
All Rough Inspection - Residential Passed 7/19/2024 7/19/2024 07/19/2024
Misc
Informational
07/17/2024
This was a portal frame only inspection. Passed 6/14/24 AF
Miscellaneous Correction
Corrective Action Required
07/17/2024
1801 SW Hightown. All rough •Tightened garage anchor bolt west wall •Steel support post in garage can not be confirmed at 3.5 inches •Truss screw is missing along the exterior garage wall between large and small overhead door •Garage anchor bolts must be in the middle 1/3 of sole plate •Fire block top of chase in garage to main entry •Garage drop down ceiling needs to be supported (span is 9 feet wide) •Supply vent duct in garage needs to be supported every 10 feet •Supply vent in pantry ceiling needs to be supported every 10 feet on center •Tub above pantry needs double floor joist in •Fire block hole in floor above pantry for tub •Nail guards are needed in sole plate for water lines at living room to bath 4 •Fire blocking above closet 5 is broken out •Plumbing chase of bedroom 5 needs to be fire blocked at •Roof boot jackets is not installed •Fire block holes in top plate in primary bedroom N/W corner •Install different tie down in truss broken at the top plate in primary bedroom west wall •Fire block top of chase between the hallway and vanity •Truss tie down screws are missing above tub of bathroom 4 •Hole in top place in bedroom 4 •Double floor joist are required on all floors below tubs
Erosion Control Inspection Residential Partial 8/16/2024 08/16/2024
Miscellaneous Correction
Informational
07/17/2024
Full erosion control measures are in place and must be maintained until CofO
Driveway Inspection Partial 9/3/2024 09/03/2024
Misc
Informational
09/03/2024
9-3-2024 Dustin A, DW is formed and compacted , Approved to pour
Driveway Inspection Passed 9/10/2024 9/10/2024 09/10/2024
Misc
Informational
09/03/2024
9-3-2024 Dustin A, DW is formed and compacted , Approved to pour 9-10-24 Dustin A, DW is poured to city specs and forms are pulled.Passed
Erosion Control Inspection Residential Partial 9/24/2024 09/24/2024
Miscellaneous Correction
Informational
08/16/2024
Full erosion control measures are in place and must be maintained until CofO
Occupancy Inspection - Codes Residential Failed 9/24/2024 9/24/2024 09/24/2024
Miscellaneous Correction
Corrective Action Required
09/24/2024
1801 SW Hightown. Occupancy Properly install spark rings in kitchen backsplash Pig tail to disposal in not installed Garage to house door is missing its seal Fire block gaps in sheet rock in garage First riser height at stairs going from the main level up is not to code Gaps in attic access hatch in utility room No handrail is intro the basement No light receptacle at the bottom of the stairs to illuminate the stairs Gutters are not fully installed Sod, splash pads are sump pump extension are not installed Seal all exterior penetrations
Occupancy Inspection - Codes Residential Not Ready 9/30/2024 9/30/2024 09/30/2024
Miscellaneous Correction
Corrective Action Required
09/24/2024
1801 SW Hightown. Occupancy Properly install spark rings in kitchen backsplash Pig tail to disposal in not installed Garage to house door is missing its seal Fire block gaps in sheet rock in garage First riser height at stairs going from the main level up is not to code Gaps in attic access hatch in utility room No handrail is intro the basement No light receptacle at the bottom of the stairs to illuminate the stairs Gutters are not fully installed Sod, splash pads are sump pump extension are not installed Seal all exterior penetrations
Miscellaneous Correction
Corrective Action Required
09/30/2024
•Properly install spark rings in kitchen backsplash •First riser height at stairs going from the main level up is not to code •No light receptacle at the bottom of the stairs to illuminate the stairs •Sod, splash pads are sump pump extension are not installed •Seal all exterior penetrations
Occupancy Inspection - Codes Residential Failed 10/9/2024 10/9/2024 10/09/2024
Miscellaneous Correction
Resolved
10/09/2024
1801 SW Hightown. Occupancy No light receptacle at the bottom of the stairs to illuminate the stairs
Miscellaneous Correction
Corrective Action Required
10/09/2024
1801 SW Hightown. Occupancy No light receptacle at the bottom of the stairs to illuminate the stairs
Plot Plan Inspection Passed 10/29/2024 10/29/2024
Erosion Control Inspection Residential Passed 10/29/2024 10/29/2024
Miscellaneous Correction
Resolved
10/29/2024
Full erosion control measures are in place and must be maintained until CofO
Occupancy Inspection - Codes Residential Failed 10/29/2024 10/29/2024 10/29/2024
Miscellaneous Correction
Corrective Action Required
10/09/2024
1801 SW Hightown. Occupancy No light receptacle at the bottom of the stairs to illuminate the stairs House is locked and no access code was provided KBEARD 10/29/24 9:05am
Occupancy Inspection - Codes Residential Not Ready 11/1/2024 11/1/2024 11/01/2024
Miscellaneous Correction
Resolved
11/01/2024
1801 SW Hightown. Occupancy No light receptacle at the bottom of the stairs to illuminate the stairs House is locked and no access code was provided KBEARD 10/29/24 9:05am
Miscellaneous Correction
Corrective Action Required
11/01/2024
- Basement handrail is not installed - Electrical light switch plate in basement is not installed exposing wires Walk your property before scheduling inspections Not ready for inspection
Occupancy Inspection - Codes Residential Full C of O 11/15/2024 11/15/2024 11/15/2024
Miscellaneous Correction
Resolved
11/15/2024
- Basement handrail is not installed - Electrical light switch plate in basement is not installed exposing wires Walk your property before scheduling inspections Not ready for inspection
Documents & Images
Date Uploaded File Type Document Name
04/03/2024 106 Reserve at Stoney Creek - Brookside - 032224
04/03/2024 LOT 106 FINAL
04/13/2024 106 Reserve at Stoney Creek - Brookside - 041224
04/16/2024 RS 106 License_Tax_Application Signed
04/16/2024 RS 106 Permit Application Signed
04/16/2024 Plot Plan APPROVED PLOT PLAN
04/16/2024 Permit Codes Residential Plan Review
04/18/2024 106 Reserve at Stoney Creek - Brookside - 041724
04/18/2024 1801 SW HIGHTOWN DR RESPONSE LETTER
04/18/2024 Permit Codes Residential Plan Review
04/18/2024 Permit DS Building Permit
04/18/2024 Receipt Receipt for transaction:2024-002503
04/24/2024 Letter INSPECTION SUMMARY
04/24/2024 Letter INSPECTION SUMMARY
05/14/2024 Letter INSPECTION SUMMARY
05/15/2024 Letter INSPECTION SUMMARY
05/15/2024 Letter INSPECTION SUMMARY
05/15/2024 Letter INSPECTION SUMMARY
05/15/2024 Letter INSPECTION SUMMARY
05/16/2024 Letter INSPECTION SUMMARY
05/23/2024 106 Reserve at Stoney Creek - Brookside - 052024
05/23/2024 Approved Plans APPROVED 1ST FLOOR TRUSS LAYOUT
05/23/2024 Approved Plans APPROVED 2ND FLOOR TRUSS LAYOUT
05/23/2024 Approved Plans APPROVED UPDATED PLANS
06/04/2024 Letter INSPECTION SUMMARY
06/10/2024 Letter INSPECTION SUMMARY
06/10/2024 Letter INSPECTION SUMMARY
06/12/2024 Letter INSPECTION SUMMARY
06/14/2024 Letter INSPECTION SUMMARY
06/27/2024 Letter INSPECTION SUMMARY
07/17/2024 Letter INSPECTION SUMMARY
07/17/2024 Letter INSPECTION SUMMARY
07/17/2024 Letter INSPECTION SUMMARY
07/17/2024 Letter INSPECTION SUMMARY
07/19/2024 Letter INSPECTION SUMMARY
08/16/2024 Letter INSPECTION SUMMARY
09/03/2024 Letter INSPECTION SUMMARY
09/10/2024 Letter INSPECTION SUMMARY
09/24/2024 Letter INSPECTION SUMMARY
09/24/2024 Letter INSPECTION SUMMARY
09/30/2024 Letter INSPECTION SUMMARY
10/09/2024 Letter INSPECTION SUMMARY
10/09/2024 Letter INSPECTION SUMMARY
10/09/2024 Letter INSPECTION SUMMARY
10/17/2024 Receipt Receipt for transaction:2024-008416
10/29/2024 Letter INSPECTION SUMMARY
10/29/2024 Letter INSPECTION SUMMARY
10/29/2024 Letter INSPECTION SUMMARY
11/01/2024 Letter INSPECTION SUMMARY
11/14/2024 Receipt Receipt for transaction:2024-008976
11/15/2024 Letter Codes Final Certificate of Occupancy
11/15/2024 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home