Permit Application Status

PRRES20240373


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20240373
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. UNCOVERED PATIO. ROOF TRUSSES.
01/30/2024
02/09/2024
08/04/2024
03/13/2025
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CMH PARKS INC, Address:5000 CLAYTON RD  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
ISAIAH@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Water Tap Fee $3,760.00 $3,760.00 Paid 02/09/2024
Water Meter Fee $680.46 $680.46 Paid 02/09/2024
Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 02/09/2024
Right of Way Permit Fee $85.00 $85.00 Paid 02/09/2024
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 02/09/2024
Valuation Fee New Single Family $1,950.88 $1,950.88 Paid 02/09/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 09/30/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 09/30/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 09/30/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 09/30/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 12/06/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 01/16/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 03/13/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 03/13/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 2/26/2024 2/26/2024 02/26/2024
Erosion Control Inspection Residential Failed 2/26/2024 02/26/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/26/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
02/26/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Sewer Service Inspection - R Passed 3/1/2024 03/01/2024
Water Service Inspection - R Passed 3/5/2024 03/05/2024
Underslab Plumbing Inspection - Residential Passed 3/20/2024 3/20/2024 03/20/2024
Erosion Control Inspection Residential Failed 3/20/2024 03/20/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/26/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Repair downed silt fence at front of lot
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
02/26/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
All Rough Inspection - Residential Not Ready 7/26/2024 7/26/2024 07/26/2024
Misc
Corrective Action Required
07/26/2024
Nailing not completed Strap still not nailed
Electrical Service Inspection Passed 9/3/2024 9/3/2024 09/03/2024
All Rough Inspection - Residential Failed 9/3/2024 9/3/2024 09/03/2024
Misc
Corrective Action Required
07/26/2024
-fire block garage rear wall into fire down -fire block hvac chase in garage into furr down -install tension straps at phf per table and code -missing hold downs at trusses above garage -fire block dead space at kitchen to ceiling space -address holes drilled closer than 2” to each other and top or bottom of floor joists above main floor -missing truss hangers throughout -fire block hvac chases around great room windows -uncover front patio area to inspect nailing and trusses -install roof boots -3studs at exterior wall corners see SW Corner -add blocking under kitchen island to 48” OC -solid block floor joist parallel to foundation wall to code
All Rough Inspection - Residential Not Ready 9/9/2024 9/9/2024 09/09/2024
Misc
Corrective Action Required
09/03/2024
-fire block garage rear wall into furr down (seal gaps) -fire block hvac chase in garage into furr down -missing hold downs at trusses above garage -address holes drilled closer than 2” to each other and top or bottom of floor joists above main floor(provide engineering for fix) -missing truss hangers throughout -fire block hvac chases around great room windows -uncover front patio area to inspect nailing and trusses -install roof boots -3studs at exterior wall corners see SW Corner
All Rough Inspection - Residential Not Ready 9/20/2024 9/20/2024 09/20/2024
Misc
Corrective Action Required
09/09/2024
-fire block garage rear wall into furr down (seal gaps) -fire block hvac chase in garage into furr down -missing hold downs at trusses above garage -address holes drilled closer than 2” to each other and top or bottom of floor joists above main floor(provide engineering for fix) -missing truss hangers throughout -fire block hvac chases around great room windows -uncover front patio area to inspect nailing and trusses -install roof boots -3studs at exterior wall corners see SW Corner
Erosion Control Inspection Residential Failed 9/26/2024 9/26/2024 09/26/2024
DCM3 ESC REQUIRED 2 DAY
Resolved
09/26/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Repair downed silt fence at front of lot
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
09/26/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
09/26/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -CUT OVERGROWN VEGETATION AND MAINTAIN SILT FENCE
All Rough Inspection - Residential Not Ready 9/26/2024 9/26/2024 09/26/2024
Misc
Corrective Action Required
09/20/2024
-fire block garage rear wall into furr down (seal gaps) -missing hold downs at trusses above garage-still missing 1 -address holes drilled closer than 2” to each other and top or bottom of floor joists above main floor(provide engineering for fix) -fire block hvac chases around great room windows -install roof boots -3studs at exterior wall corners see SW Corner-Screw all plies together with structural screws and nail sheathing
All Rough Inspection - Residential Failed 9/27/2024 9/27/2024 09/27/2024
Misc
Corrective Action Required
09/26/2024
-install roof boots
All Rough Inspection - Residential Passed 10/1/2024 10/1/2024 10/01/2024
Misc
Resolved
10/01/2024
Gas Service Inspection - Residential Passed 10/1/2024 10/1/2024 10/01/2024
Driveway Inspection Partial 10/21/2024 10/21/2024 10/21/2024
Misc
Informational
10/21/2024
10-21-24 Dustin A , dw is formed and compacted, Approved to pour
Driveway Inspection Passed 10/31/2024 10/31/2024 10/30/2024
Misc
Informational
10/21/2024
10-21-24 Dustin A , dw is formed and compacted, Approved to pour 10-30-24 Dustin A, DW is poured to city specs,Passed
Occupancy Inspection - Codes Residential Failed 12/3/2024 12/3/2024 12/03/2024
Misc
Corrective Action Required
12/03/2024
-uncover covered water meter -final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -garage entry door to be self closing and latching -hand rail required at rear patio stairs -install and shear off set screw at water anti siphon device -uncover drain in egress window well and bring rock level -guard rail at front stoop shall not have gaps greater than 4”
Occupancy Inspection - Codes Residential Failed 12/5/2024 12/5/2024 12/05/2024
Misc
Corrective Action Required
12/03/2024
-uncover covered water meter -final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -shear off set screw at water anti siphon device
Occupancy Inspection - Codes Residential Ready for Temp CO 12/6/2024 12/6/2024 12/06/2024
Misc
Corrective Action Required
12/05/2024
-uncover covered water meter -final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation
Occupancy Inspection - Codes Residential Ready for Temp CO 1/8/2025 01/08/2025
Misc
Corrective Action Required
12/06/2024
-uncover covered water meter -final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation
Occupancy Inspection - Codes Residential Full C of O 3/13/2025 3/13/2025 03/13/2025
Misc
Resolved
03/13/2025
-uncover covered water meter -final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation
Documents & Images
Date Uploaded File Type Document Name
01/30/2024 H4 # 111 - PERMIT APP
02/06/2024 Permit Codes Residential Plan Review
02/08/2024 Plot Plan APPROVED PLOT PLAN
02/08/2024 Approved Plans APPROVED PLANS
02/08/2024 Approved Plans APPROVED TRUSS PACKAGE
02/08/2024 Approved Plans APPROVED TRUSS LAYOUT
02/08/2024 Permit Codes Residential Plan Review
02/09/2024 Permit DS Building Permit
02/09/2024 Receipt Receipt for transaction:2024-000752
02/24/2024 M L Crose 3209 SW Arbor Tree Dr LSMO Clayton Properties Permit 2024-0373 3rd Party Footing Inspection Report 2-23-24
02/26/2024 Letter INSPECTION SUMMARY
02/26/2024 Letter INSPECTION SUMMARY
03/01/2024 Letter INSPECTION SUMMARY
03/05/2024 Letter INSPECTION SUMMARY
03/20/2024 Letter INSPECTION SUMMARY
03/20/2024 Letter INSPECTION SUMMARY
07/26/2024 Letter INSPECTION SUMMARY
09/03/2024 Letter INSPECTION SUMMARY
09/03/2024 Letter INSPECTION SUMMARY
09/09/2024 Letter INSPECTION SUMMARY
09/20/2024 Letter INSPECTION SUMMARY
09/26/2024 111 Hawthorne Ridge - Seals Revised
09/26/2024 Letter INSPECTION SUMMARY
09/26/2024 Letter INSPECTION SUMMARY
09/27/2024 Engineer Report/Study THIRD PARTY FIELD ENGINEER LETTER
09/27/2024 Letter INSPECTION SUMMARY
09/30/2024 H4 #111 - Revised TRUSS LAYOUT
09/30/2024 Receipt Receipt for transaction:2024-008014
09/30/2024 Approved Plans 9-30-24 REVISED TRUSS LAYOUT
10/01/2024 Letter INSPECTION SUMMARY
10/01/2024 Letter INSPECTION SUMMARY
10/21/2024 Letter INSPECTION SUMMARY
10/30/2024 Letter INSPECTION SUMMARY
12/03/2024 Letter INSPECTION SUMMARY
12/05/2024 Letter INSPECTION SUMMARY
12/06/2024 Letter INSPECTION SUMMARY
12/06/2024 Certificate/License Codes Temporary Certificate of Occupancy
12/06/2024 Receipt Receipt for transaction:2024-009374
01/03/2025 Application Form TCO EXTENSION
01/16/2025 Certificate/License Codes Temporary Certificate of Occupancy
01/16/2025 Receipt Receipt for transaction:2025-000286
03/13/2025 Certificate/License Codes Temporary Certificate of Occupancy
03/13/2025 Certificate/License Codes Temporary Certificate of Occupancy
03/13/2025 Receipt Receipt for transaction:2025-001510
03/13/2025 Letter INSPECTION SUMMARY
03/13/2025 Letter Codes Final Certificate of Occupancy
03/13/2025 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home