Permit Application Status

PRRES20240309


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20240309
Building Permit - Residential
Certificate of Occupancy
NEW 3 OR 4 FAMILY
NEW TOWNHOME. FINISHED/UNFINISHED BASEMENT. ROOF TRUSSES. UNCOVERED DECK.
01/25/2024
02/08/2024
07/30/2024
08/30/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
CARUTHERS ELECTRICAL LLC, Address:30905 E TRUMAN RD, Phone:(816) 508-9050  
BILL'S PLUMBING SERVICE LLC, Address:308 E PARK STREET, Phone:(913) 829-8213  
JASONH@CLOVERANDHIVE.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for New 3 or 4 Family $4,453.33 $4,453.33 Paid 02/08/2024
Water Tap Fee $15,040.00 $15,040.00 Paid 02/08/2024
Water Meter Fee $2,721.84 $2,721.84 Paid 02/08/2024
Sanitary Sewer Development Fee $8,636.00 $8,636.00 Paid 02/08/2024
Right of Way Permit Fee $85.00 $85.00 Paid 02/08/2024
Residential Excise Tax Fee $2,480.64 $2,480.64 Paid 02/08/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 07/25/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 07/25/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 07/25/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 07/30/2024
3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 07/30/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 07/31/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 08/07/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 3/4/2024 03/04/2024
Miscellaneous Correction
Informational
03/04/2024
Footing passed by a third party. Piers were not mentioned in the footing report
Sewer Service Inspection - R Partial 3/4/2024 3/4/2024 03/04/2024
Miscellaneous Correction
Informational
03/04/2024
3734 sewer passed. This is a partial pass only, other units will be scheduled at a later date
Sewer Service Inspection - R Partial 3/5/2024 3/5/2024 03/05/2024
Miscellaneous Correction
Informational
03/04/2024
3734 sewer passed. This is a partial pass only, other units will be scheduled at a later date
Miscellaneous Correction
Informational
03/05/2024
3734 and 3736 sewer passed. This is a partial pass only, other units will be scheduled at a later date
Sewer Service Inspection - R Passed 3/6/2024 3/6/2024 03/06/2024
Miscellaneous Correction
Informational
03/05/2024
3734 sewer passed. This is a partial pass only, other units will be scheduled at a later date
Miscellaneous Correction
Informational
03/05/2024
3734 and 3736 sewer passed. This is a partial pass only, other units will be scheduled at a later date
Miscellaneous Correction
Informational
03/06/2024
All units for sewer passed
Water Service Inspection - R Partial 3/6/2024 03/06/2024
Miscellaneous Correction
Informational
03/06/2024
All four units have PEX pipe coming out from the stem wall about 20 feet. Okay to back fill the PEX pipe. This is a partial pass only.
Erosion Control Inspection Residential Failed 3/6/2024 03/06/2024
Miscellaneous Correction
Corrective Action Required
03/06/2024
-Lot access gravel needs to be installed. -Full erosion control must be in place and maintained until CofO. No inspections will be conducted until full erosion control measures have been installed 03/06/24. KBEARD
Erosion Control Inspection Residential Partial 3/14/2024 03/14/2024
Miscellaneous Correction
Resolved
03/14/2024
-Lot access gravel needs to be installed. -Full erosion control must be in place and maintained until CofO. No inspections will be conducted until full erosion control measures have been installed 03/06/24. KBEARD
Miscellaneous Correction
Informational
03/14/2024
Full erosion control is in place at the time of underslab plumbing inspection. Full erosion control must be maintained until CofO
Underslab Plumbing Inspection - Residential Passed 3/14/2024 3/14/2024 03/14/2024
Erosion Control Inspection Residential Failed 4/5/2024 04/05/2024
Miscellaneous Correction
Informational
03/14/2024
Full erosion control is in place at the time of underslab plumbing inspection. Full erosion control must be maintained until CofO
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/05/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYs Sweep gravel from streets and reinstall or repair silt fence at street before a stop work order is issued
All Rough Inspection - Residential Not Ready 4/8/2024 4/8/2024 04/08/2024
Miscellaneous Correction
Corrective Action Required
04/08/2024
-Garage portal CS-PF passed on all units -All other CS-PF and CS-WSP failed due to not being fully installed Walk your property before scheduling inspections. Not ready for inspection
Water Service Inspection - R Passed 4/24/2024 4/24/2024 04/24/2024
Miscellaneous Correction
Resolved
04/24/2024
All four units have PEX pipe coming out from the stem wall about 20 feet. Okay to back fill the PEX pipe. This is a partial pass only.
Rated Assembly Inspection Failed 5/1/2024 5/1/2024 05/01/2024
Miscellaneous Correction
Corrective Action Required
05/01/2024
3734 SW Clayton. Rated assembly Roof vent hole cut out within 4 feet of rated wall Larger than 1/4 inch gap in rated plywood 18 inches down from the ridge 3736 Front entrance has a distance of more than 10 feet for vertical fire blocking Vertical fire block basement S/W corner at the top Block block is missing in bedroom 1 above top plate at S/E corner 3738 Vertically fire block garage north wall every 10 feet on center or less Fire blocking is missing in front entrance at S/E corner Vertically fire block basement N/W corner 3740 Roof vent cut in rated assembly decking
Electrical Service Inspection Passed 5/1/2024 5/1/2024 05/01/2024
Gas Service Inspection - Residential Passed 5/1/2024 5/1/2024 05/01/2024
All Rough Inspection - Residential Failed 5/1/2024 5/1/2024 05/01/2024
Miscellaneous Correction
Resolved
05/01/2024
-Garage portal CS-PF passed on all units -All other CS-PF and CS-WSP failed due to not being fully installed Walk your property before scheduling inspections. Not ready for inspection
Miscellaneous Correction
Corrective Action Required
05/01/2024
3734 SW Clayton. All rough Garage anchor bolts must be placed in the middle 1/3 of sole plate Garage sole plate is missing the 5/8 inch anchor bolt with a plate Address all missing garage anchor bolts Nail bedroom 1 closet to code Re attach vent fan flex pipe in bathroom 2 3736 anchor bolts in garage are not secured properly Garage sole plate is missing the 5/8 inch anchor bolt with a plate Address all missing garage anchor bolts Have engineers letter for garage south sole plate not being supported by the concrete foundation wall All garage anchor bolts must be in the middle 1/3 of sole plate Nail N/W dining room corner to code Fire block top plate in basement closet 3738 Secure anchor bolts in garage Install garage anchor bolts 4-12 inches from the ends Garage sole plate is missing the 5/8 inch anchor bolt with a plate Fire blocking missing in joist space above garage Ibeam Nail N/W corner of great room to code Latterly truss bracing is blocking the required height clearance for the attic access Nail S/W corner of bedroom one and closet to code Fire block top plate in closet of basement 3740 Garage anchor bolts need to be in the middle 1/3 of sole plate Garage sole plate is missing the 5/8 inch anchor bolt with a plate Garage sole plate is missing required anchor bolts Have engineers letter address where sole plate is not fully on foundation wall Nail front entry and dining room corners to code Truss tie down screw is missing in bedroom 2 Secure 10/2 wire in basement ceiling chase
Erosion Control Inspection Residential Partial 5/8/2024 05/08/2024
Miscellaneous Correction
Resolved
05/08/2024
Full erosion control is in place at the time of underslab plumbing inspection. Full erosion control must be maintained until CofO
DCM3 ESC REQUIRED 2 DAY
Resolved
05/08/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYs Sweep gravel from streets and reinstall or repair silt fence at street before a stop work order is issued
Miscellaneous Correction
Corrective Action Required
05/08/2024
Repair silt fence at street Full erosion control measures must be maintained until CofO
Rated Assembly Inspection Failed 5/8/2024 5/8/2024 05/08/2024
Miscellaneous Correction
Resolved
05/08/2024
3734 SW Clayton. Rated assembly Roof vent hole cut out within 4 feet of rated wall Larger than 1/4 inch gap in rated plywood 18 inches down from the ridge 3736 Front entrance has a distance of more than 10 feet for vertical fire blocking Vertical fire block basement S/W corner at the top Block block is missing in bedroom 1 above top plate at S/E corner 3738 Vertically fire block garage north wall every 10 feet on center or less Fire blocking is missing in front entrance at S/E corner Vertically fire block basement N/W corner 3740 Roof vent cut in rated assembly decking
Miscellaneous Correction
Corrective Action Required
05/08/2024
3734 SW Clayton. Rated assembly Roof vent hole cut out within 4 feet of rated wall 3736 Vertical fire block basement S/W corner at the top 3740 Roof vent cut in rated assembly decking
All Rough Inspection - Residential Failed 5/8/2024 5/8/2024 05/08/2024
Miscellaneous Correction
Resolved
05/08/2024
3734 SW Clayton. All rough Garage anchor bolts must be placed in the middle 1/3 of sole plate Garage sole plate is missing the 5/8 inch anchor bolt with a plate Address all missing garage anchor bolts Nail bedroom 1 closet to code Re attach vent fan flex pipe in bathroom 2 3736 anchor bolts in garage are not secured properly Garage sole plate is missing the 5/8 inch anchor bolt with a plate Address all missing garage anchor bolts Have engineers letter for garage south sole plate not being supported by the concrete foundation wall All garage anchor bolts must be in the middle 1/3 of sole plate Nail N/W dining room corner to code Fire block top plate in basement closet 3738 Secure anchor bolts in garage Install garage anchor bolts 4-12 inches from the ends Garage sole plate is missing the 5/8 inch anchor bolt with a plate Fire blocking missing in joist space above garage Ibeam Nail N/W corner of great room to code Latterly truss bracing is blocking the required height clearance for the attic access Nail S/W corner of bedroom one and closet to code Fire block top plate in closet of basement 3740 Garage anchor bolts need to be in the middle 1/3 of sole plate Garage sole plate is missing the 5/8 inch anchor bolt with a plate Garage sole plate is missing required anchor bolts Have engineers letter address where sole plate is not fully on foundation wall Nail front entry and dining room corners to code Truss tie down screw is missing in bedroom 2 Secure 10/2 wire in basement ceiling chase
Miscellaneous Correction
Corrective Action Required
05/08/2024
3734 SW Clayton. All rough Garage sole plate is missing the 5/8 inch anchor bolt with a plate 3736 Fire block top plate in basement closet 3738 Fire block top plate in closet of basement Add stud in basement closet
Rated Assembly Inspection Partial 5/10/2024 5/10/2024 05/10/2024
Miscellaneous Correction
Resolved
05/10/2024
3734 SW Clayton. Rated assembly Roof vent hole cut out within 4 feet of rated wall 3736 Vertical fire block basement S/W corner at the top 3740 Roof vent cut in rated assembly decking
Miscellaneous Correction
Informational
05/10/2024
Fire rated assembly will need to be checked for screw pattern when read
All Rough Inspection - Residential Passed 5/10/2024 5/10/2024 05/10/2024
Miscellaneous Correction
Resolved
05/10/2024
3734 SW Clayton. All rough Garage sole plate is missing the 5/8 inch anchor bolt with a plate 3736 Fire block top plate in basement closet 3738 Fire block top plate in closet of basement Add stud in basement closet
Rated Assembly Inspection Failed 5/17/2024 5/17/2024 05/17/2024
Miscellaneous Correction
Resolved
05/17/2024
Fire rated assembly will need to be checked for screw pattern when read
Miscellaneous Correction
Corrective Action Required
05/17/2024
3740 SW Clayton. Screw pattern bathroom of bedroom one screw pattern is not correct 3736 screw pattern passed 3738 and 3734 are not ready for inspection
Rated Assembly Inspection Passed 5/20/2024 5/20/2024 05/20/2024
Miscellaneous Correction
Resolved
05/20/2024
3740 SW Clayton. Screw pattern bathroom of bedroom one screw pattern is not correct 3736 screw pattern passed 3738 and 3734 are not ready for inspection
Driveway Inspection Partial 5/22/2024 5/22/2024 05/22/2024
Misc
Informational
05/22/2024
5-22-24 Dustin A, DW's are formed and compacted to city specs. Approved to pour
Sidewalk Inspection Partial 5/22/2024 5/22/2024 05/22/2024
Misc
Informational
05/22/2024
5-22-24 Dustin A, SW's are formed to city specs. Approved to pour
Driveway Inspection Passed 5/29/2024 5/29/2024 05/29/2024
Misc
Informational
05/22/2024
5-22-24 Dustin A, DW's are formed and compacted to city specs. Approved to pour (3734-3740) 5-29-24 Dustin A, DW's are poured to city specs. Passed
Sidewalk Inspection Passed 5/29/2024 5/29/2024 05/29/2024
Misc
Informational
05/22/2024
5-22-24 Dustin A, SW's are formed to city specs. Approved to pour (3734-3740) 5-29-24 Dustin A, SW's are poured to city specs. Passed
Erosion Control Inspection Residential Partial 7/11/2024 07/11/2024
Miscellaneous Correction
Resolved
07/11/2024
Repair silt fence at street Full erosion control measures must be maintained until CofO
Miscellaneous Correction
Informational
07/11/2024
Full erosion control is in place and must be maintained until CofO
Occupancy Inspection - Codes Residential Not Ready 7/11/2024 7/11/2024 07/11/2024
Miscellaneous Correction
Corrective Action Required
07/11/2024
Fall protection is not provided on any of the four units at the dining/great room sliding door Install fall protection before rescheduling occupancy inspection All units are not ready for inspection
Piers/Caissons Inspection - Residential Not Ready 7/16/2024 07/16/2024
Miscellaneous Correction
Corrective Action Required
07/16/2024
Back deck piers at 3734 was the only one ready for inspection. All other units were not ready When scheduling for inspections, just schedule which units are ready, otherwise a not ready fee will be applied
Piers/Caissons Inspection - Residential Failed 7/17/2024 7/17/2024 07/17/2024
Miscellaneous Correction
Resolved
07/17/2024
Back deck piers at 3734 was the only one ready for inspection. All other units were not ready When scheduling for inspections, just schedule which units are ready, otherwise a not ready fee will be applied
Miscellaneous Correction
Corrective Action Required
07/17/2024
Piers at 3736 passed inspection Units 3736 and 3734 have both passed. Other units will be scheduled for a later date This is a partial pass only
Occupancy Inspection - Codes Residential Failed 7/22/2024 7/22/2024 07/22/2024
Miscellaneous Correction
Resolved
07/22/2024
Fall protection is not provided on any of the four units at the dining/great room sliding door Install fall protection before rescheduling occupancy inspection All units are not ready for inspection
Miscellaneous Correction
Corrective Action Required
07/22/2024
3734 and 3736 SW Clayton. Occupancy 3734 Fire block all sheet rock gaps in the garage Garage to house self closing door will not fully shut and lock Fire block opening under basement stairs in closet Remove dust cover from smoke /carbon detector in mechanical room Back patio does not have a landing platform at the bottom of the stairs 3736 Front porch needs a guard rail installed because of a greater than 30 inch drop Light in garage does not work Fire block gaps in sheet rock in garage GFCI on back deck is not working Back patio does not have a landing platform at the bottom of the stairs Last riser to upper platform from main floor has a greater than 3/8 of an inch difference Basement handrail is loose Fire block under basement stairs in closet Remove dust cover from smoke/carbon detector in mechanical room Sod, splash pads and sump pump extensions need to be installed Install erosion control at the front of the property and clean dirt from sidewalk before rescheduling any further inspections Pay fees of $225 associated with this permit Units 3738 and 3740 were not inspected This is a partial inspection only
Erosion Control Inspection Residential Failed 7/22/2024 07/22/2024
Miscellaneous Correction
Resolved
07/22/2024
Full erosion control is in place and must be maintained until CofO
Miscellaneous Correction
Corrective Action Required
07/22/2024
Remove dirt and gravel from driveway and sidewalk Install erosion control at the front of the property Full erosion control measures must be maintained until CofO
Piers/Caissons Inspection - Residential Failed 7/22/2024 07/22/2024
Miscellaneous Correction
Resolved
07/22/2024
Piers at 3736 passed inspection Units 3736 and 3734 have both passed. Other units will be scheduled for a later date This is a partial pass only
Miscellaneous Correction
Corrective Action Required
07/22/2024
Piers at 3738 passed inspection Units 3734,3736 and 3738 all passed. One other unit will be scheduled at a later date This is a partial pass only
Piers/Caissons Inspection - Residential Passed 7/24/2024 7/24/2024 07/24/2024
Miscellaneous Correction
Resolved
07/24/2024
Piers at 3738 passed inspection Units 3734,3736 and 3738 all passed. One other unit will be scheduled at a later date This is a partial pass only
Occupancy Inspection - Codes Residential Not Ready 7/25/2024 7/25/2024 07/25/2024
Miscellaneous Correction
Corrective Action Required
07/22/2024
3734 and 3736 SW Clayton. Occupancy 3734 Fire block all sheet rock gaps in the garage Garage to house self closing door will not fully shut and lock Fire block opening under basement stairs in closet Remove dust cover from smoke /carbon detector in mechanical room Back patio does not have a landing platform at the bottom of the stairs 3736 Front porch needs a guard rail installed because of a greater than 30 inch drop Light in garage does not work Fire block gaps in sheet rock in garage GFCI on back deck is not working Back patio does not have a landing platform at the bottom of the stairs Last riser to upper platform from main floor has a greater than 3/8 of an inch difference Basement handrail is loose Fire block under basement stairs in closet Remove dust cover from smoke/carbon detector in mechanical room 3738 -Fire block gaps in garage -GFCI at deck not working -No landing at base of stairs at deck -Smoke detector hanging loose at front bedroom -Access panel in basement closet under stairs not secure -Missing vent covers throughout upstairs Sod, splash pads and sump pump extensions need to be installed Install erosion control at the front of the property and clean dirt from sidewalk before rescheduling any further inspections Pay fees of $225 associated with this permit Unit 3740 was not inspected This is a partial inspection only
Misc
Corrective Action Required
07/25/2024
-No access to unit 3740 NOT READY
Occupancy Inspection - Codes Residential Failed 7/26/2024 7/26/2024 07/26/2024
Miscellaneous Correction
Corrective Action Required
07/25/2024
3734 and 3736 SW Clayton. Occupancy 3734 Fire block all sheet rock gaps in the garage Garage to house self closing door will not fully shut and lock Fire block opening under basement stairs in closet Remove dust cover from smoke /carbon detector in mechanical room Back patio does not have a landing platform at the bottom of the stairs 3736 Front porch needs a guard rail installed because of a greater than 30 inch drop Light in garage does not work Fire block gaps in sheet rock in garage GFCI on back deck is not working Back patio does not have a landing platform at the bottom of the stairs Last riser to upper platform from main floor has a greater than 3/8 of an inch difference Basement handrail is loose Fire block under basement stairs in closet Remove dust cover from smoke/carbon detector in mechanical room 3738 -Fire block gaps in garage -GFCI at deck not working -No landing at base of stairs at deck -Smoke detector hanging loose at front bedroom -Access panel in basement closet under stairs not secure -Missing vent covers throughout upstairs Sod, splash pads and sump pump extensions need to be installed Install erosion control at the front of the property and clean dirt from sidewalk before rescheduling any further inspections Pay fees of $225 associated with this permit Unit 3740 was not inspected This is a partial inspection only
Misc
Corrective Action Required
07/25/2024
-No access to unit 3740 NOT READY
Misc
Corrective Action Required
07/26/2024
3734,3736, 3738 and 3740 SW Clayton. Occupancy (3) 3734 Fire block all sheet rock gaps in the garage Garage to house self closing door will not fully shut and lock Fire block opening under basement stairs in closet Remove dust cover from smoke /carbon detector in mechanical room Back patio does not have a landing platform at the bottom of the stairs 3736 Front porch needs a guard rail installed because of a greater than 30 inch drop Light in garage does not work Fire block gaps in sheet rock in garage GFCI on back deck is not working Back patio does not have a landing platform at the bottom of the stairs Last riser to upper platform from main floor has a greater than 3/8 of an inch difference Basement handrail is loose Fire block under basement stairs in closet Remove dust cover from smoke/carbon detector in mechanical room 3738 -Fire block gaps in garage -GFCI at deck not working -No landing at base of stairs at deck -Smoke detector hanging loose at front bedroom -Access panel in basement closet under stairs not secure -Missing vent covers throughout upstairs 3740 SW Clayton. Handrail height at stairwell entry to main living needs to be between 34-38 inches Concrete platform is not installed at back deck to yard Install spark ring at electrical outlet in kitchen backsplash Installed stove anti tip bracket per manufacturer instructions Secure hatch under the basement stairs in closet Remove dust cover from smoke/CO detector in mechanical room Fire block open joint in sheet rock in garage above overhead door Fire block open area in garage at bottom of stair stringer to sheet rock Sod, splash pads and sump pump extensions need to be installed Pay $125 fee associated with this permit
Occupancy Inspection - Codes Residential Failed 7/29/2024 7/29/2024 07/29/2024
Miscellaneous Correction
Corrective Action Required
07/26/2024
3734 and 3736 SW Clayton. Occupancy 3734 - Back patio does not have a landing platform at the bottom of the stairs 3736 -Back patio does not have a landing platform at the bottom of the stairs 3738 -No landing at base of stairs at deck 3740 - Concrete platform is not installed at back deck to yard -Install spark ring at electrical outlet in kitchen backsplash - Install stove anti tip bracket per manufacturer instructions Sod, splash pads and sump pump extensions need to be installed - Water meter to be at grade - Land sewer trace wire to grade
Misc
Resolved
07/29/2024
Miscellaneous Correction
Resolved
07/29/2024
3734,3736, 3738 and 3740 SW Clayton. Occupancy (3) 3734 Fire block all sheet rock gaps in the garage Garage to house self closing door will not fully shut and lock Fire block opening under basement stairs in closet Remove dust cover from smoke /carbon detector in mechanical room Back patio does not have a landing platform at the bottom of the stairs 3736 Front porch needs a guard rail installed because of a greater than 30 inch drop Light in garage does not work Fire block gaps in sheet rock in garage GFCI on back deck is not working Back patio does not have a landing platform at the bottom of the stairs Last riser to upper platform from main floor has a greater than 3/8 of an inch difference Basement handrail is loose Fire block under basement stairs in closet Remove dust cover from smoke/carbon detector in mechanical room 3738 -Fire block gaps in garage -GFCI at deck not working -No landing at base of stairs at deck -Smoke detector hanging loose at front bedroom -Access panel in basement closet under stairs not secure -Missing vent covers throughout upstairs 3740 SW Clayton. Handrail height at stairwell entry to main living needs to be between 34-38 inches Concrete platform is not installed at back deck to yard Install spark ring at electrical outlet in kitchen backsplash Installed stove anti tip bracket per manufacturer instructions Secure hatch under the basement stairs in closet Remove dust cover from smoke/CO detector in mechanical room Fire block open joint in sheet rock in garage above overhead door Fire block open area in garage at bottom of stair stringer to sheet rock Sod, splash pads and sump pump extensions need to be installed Pay $125 fee asscoiated with this permit
Occupancy Inspection - Codes Residential Ready for Temp CO 7/31/2024 7/31/2024 07/31/2024
Miscellaneous Correction
Corrective Action Required
07/29/2024
3738 -No landing at base of stairs at deck 3740 - Concrete platform is not installed at back deck to yard -Install spark ring at electrical outlet in kitchen backsplash - Install stove anti tip bracket per manufacturer instructions Sod, splash pads and sump pump extensions need to be installed - Water meter to be at grade - Land sewer trace wire to grade
Misc
Informational
07/31/2024
Units 3734 and 3736 are Ready for TCO 7/31/24 AF
Occupancy Inspection - Codes Residential Ready for Temp CO 8/6/2024 8/6/2024 08/06/2024
Miscellaneous Correction
Informational
08/06/2024
Units 3738 and 3740 are ready for TCO 8/6/24 AF STILL MISSING THE FOLLOWING -Sod, splash pads and sump pump extensions need to be installed -Water meter to be at grade -Land sewer trace wire to grade
Misc
Informational
07/31/2024
Units 3734 and 3736 are Ready for TCO 7/31/24 AF STILL MISSING THE FOLLOWING -Sod, splash pads and sump pump extensions need to be installed -Water meter to be at grade -Land sewer trace wire to grade
Plot Plan Inspection Passed 8/30/2024 08/30/2024
Erosion Control Inspection Residential Passed 8/30/2024 08/30/2024
Miscellaneous Correction
Resolved
08/30/2024
Remove dirt and gravel from driveway and sidewalk Install erosion control at the front of the property Full erosion control measures must be maintained until CofO
Occupancy Inspection - Codes Residential Full C of O 8/30/2024 8/30/2024 08/30/2024
Miscellaneous Correction
Resolved
08/30/2024
Units 3738 and 3740 are ready for TCO 8/6/24 AF STILL MISSING THE FOLLOWING -Sod, splash pads and sump pump extensions need to be installed -Water meter to be at grade -Land sewer trace wire to grade
Misc
Resolved
08/30/2024
Units 3734 and 3736 are Ready for TCO 7/31/24 AF STILL MISSING THE FOLLOWING -Sod, splash pads and sump pump extensions need to be installed -Water meter to be at grade -Land sewer trace wire to grade
Documents & Images
Date Uploaded File Type Document Name
01/25/2024 OS # 44 - PERMIT APP
02/01/2024 Permit Codes Residential Plan Review
02/08/2024 Plot Plan APPROVED PLOT PLAN
02/08/2024 Approved Plans APPROVED PLANS
02/08/2024 Approved Plans APPROVED TRUSS LAYOUT
02/08/2024 Approved Plans APPROVED TRUSS PACKAGE
02/08/2024 Permit Codes Residential Plan Review
02/08/2024 Permit DS Building Permit
02/08/2024 Receipt Receipt for transaction:2024-000745
02/28/2024 M L Crose 3734 3736 3738 3740 SW Clayton PL LSMO Osage Lot 44 Clayton P 2024-0309 3rd Party Footing Inspection Report 2-27-24
03/04/2024 Letter INSPECTION SUMMARY
03/04/2024 Letter INSPECTION SUMMARY
03/05/2024 Letter INSPECTION SUMMARY
03/06/2024 Letter INSPECTION SUMMARY
03/06/2024 Letter INSPECTION SUMMARY
03/06/2024 Letter INSPECTION SUMMARY
03/14/2024 Letter INSPECTION SUMMARY
03/14/2024 Letter INSPECTION SUMMARY
04/05/2024 Letter INSPECTION SUMMARY
04/08/2024 Letter INSPECTION SUMMARY
04/24/2024 Letter INSPECTION SUMMARY
05/01/2024 Letter INSPECTION SUMMARY
05/01/2024 Letter INSPECTION SUMMARY
05/01/2024 Letter INSPECTION SUMMARY
05/01/2024 Letter INSPECTION SUMMARY
05/08/2024 Engineer Report/Study ENGINEER FRAMING REPORT
05/08/2024 Letter INSPECTION SUMMARY
05/08/2024 Letter INSPECTION SUMMARY
05/08/2024 Letter INSPECTION SUMMARY
05/08/2024 Letter INSPECTION SUMMARY
05/10/2024 Letter INSPECTION SUMMARY
05/10/2024 Letter INSPECTION SUMMARY
05/10/2024 Letter INSPECTION SUMMARY
05/17/2024 Letter INSPECTION SUMMARY
05/20/2024 Letter INSPECTION SUMMARY
05/22/2024 Letter INSPECTION SUMMARY
05/22/2024 Letter INSPECTION SUMMARY
05/22/2024 Letter INSPECTION SUMMARY
05/29/2024 Letter INSPECTION SUMMARY
05/29/2024 Letter INSPECTION SUMMARY
07/11/2024 Letter INSPECTION SUMMARY
07/11/2024 Letter INSPECTION SUMMARY
07/16/2024 Letter INSPECTION SUMMARY
07/17/2024 Letter INSPECTION SUMMARY
07/22/2024 Letter INSPECTION SUMMARY
07/22/2024 Letter INSPECTION SUMMARY
07/22/2024 Letter INSPECTION SUMMARY
07/24/2024 Letter INSPECTION SUMMARY
07/25/2024 Receipt Receipt for transaction:2024-006201
07/25/2024 Letter INSPECTION SUMMARY
07/29/2024 Letter INSPECTION SUMMARY
07/30/2024 Receipt Receipt for transaction:2024-006372
07/31/2024 Letter INSPECTION SUMMARY
07/31/2024 Letter INSPECTION SUMMARY
07/31/2024 Certificate/License Codes Temporary Certificate of Occupancy
07/31/2024 Receipt Receipt for transaction:2024-006438
08/06/2024 Letter INSPECTION SUMMARY
08/07/2024 Certificate/License Codes Temporary Certificate of Occupancy
08/07/2024 Receipt Receipt for transaction:2024-006648
08/30/2024 Letter INSPECTION SUMMARY
08/30/2024 Letter INSPECTION SUMMARY
08/30/2024 Letter Field Certificate of Occupancy
08/30/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home