Permit Application Status

PRRES20236605


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20236605
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. ROOF TRUSSES.
12/19/2023
01/02/2024
06/30/2024
10/10/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
CARUTHERS ELECTRICAL LLC, Address:30905 E TRUMAN RD, Phone:(816) 508-9050  
BILL'S PLUMBING SERVICE LLC, Address:308 E PARK STREET, Phone:(913) 829-8213  
JASONH@CLOVERANDHIVE.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Water Tap Fee $3,760.00 $3,760.00 Paid 01/02/2024
Water Meter Fee $680.46 $680.46 Paid 01/02/2024
Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 01/02/2024
Right of Way Permit Fee $85.00 $85.00 Paid 01/02/2024
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 01/02/2024
Valuation Fee New Single Family $1,394.94 $1,394.94 Paid 01/02/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 05/17/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 05/17/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 06/27/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 07/23/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 09/17/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 09/17/2024
Outstanding Fees Amount Paid Owing Date Paid


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 1/4/2024 01/04/2024
Miscellaneous Correction
Informational
01/04/2024
Footing passed by a third party. No mention of piers were in the footing report
Erosion Control Inspection Residential Failed 1/4/2024 01/04/2024
Miscellaneous Correction
Corrective Action Required
01/04/2024
Erosion control is not in place at the time of footing being poured which contradicts the report by the third party at their footing inspection. 01/04/23 KBEARD
Sewer Service Inspection - R Passed 2/9/2024 2/9/2024 02/09/2024
Erosion Control Inspection Residential Partial 2/9/2024 02/09/2024
Miscellaneous Correction
Resolved
02/09/2024
Erosion control is not in place at the time of footing being poured which contradicts the report by the third party at their footing inspection. 01/04/23 KBEARD
Miscellaneous Correction
Informational
02/09/2024
Erosion control is in place at the time of sewer inspection. Full erosion control must be maintained until CofO
Water Service Inspection - R Partial 2/9/2024 02/09/2024
Miscellaneous Correction
Informational
02/09/2024
PEX is run out under the footing and about 10 feet out towards the street along the N/E corner. Okay to cover. This is a partial pass only
Water Service Inspection - R Passed 2/12/2024 02/12/2024
Miscellaneous Correction
Resolved
02/12/2024
PEX is run out under the footing and about 10 feet out towards the street along the N/E corner. Okay to cover. This is a partial pass only
Erosion Control Inspection Residential Failed 2/15/2024 02/15/2024
Miscellaneous Correction
Informational
02/09/2024
Erosion control is in place at the time of sewer inspection. Full erosion control must be maintained until CofO
Miscellaneous Correction
Corrective Action Required
02/15/2024
Erosion control has been torn down along the South side. Full erosion control must be maintained and in place when scheduling inspections. Full erosion control must be maintained until CofO. No inspections will be conducted until full erosion control is in place
Underslab Plumbing Inspection - Residential Failed 2/15/2024 2/15/2024 02/15/2024
Miscellaneous Correction
Corrective Action Required
02/15/2024
Drain tile must have 2 inches of crushed stone under it or can be lying on concrete. Tile drain can not be in contact with the ground. Look over the plans submitted to the city and approved by the city under the foundation drain and raised slab detail
Erosion Control Inspection Residential Partial 2/16/2024 02/16/2024
Miscellaneous Correction
Informational
02/15/2024
Erosion control is in place at the time of sewer inspection. Full erosion control must be maintained until CofO
Miscellaneous Correction
Resolved
02/16/2024
Erosion control has been torn down along the South side. Full erosion control must be maintained and in place when scheduling inspections. Full erosion control must be maintained until CofO. No inspections will be conducted until full erosion control is in place
Miscellaneous Correction
Informational
02/16/2024
Full erosion is in place at the time of underground plumbing inspection. Full erosion cot must be maintained until CofO
Underslab Plumbing Inspection - Residential Failed 2/16/2024 2/16/2024 02/16/2024
Miscellaneous Correction
Resolved
02/16/2024
Drain tile must have 2 inches of crushed stone under it or can be lying on concrete. Tile drain can not be in contact with the ground. Look over the plans submitted to the city and approved by the city under the foundation drain and raised slab detail
Miscellaneous Correction
Corrective Action Required
02/16/2024
Remove all wood forms from touching the earth R408.5
Underslab Plumbing Inspection - Residential Passed 2/16/2024 02/16/2024
Miscellaneous Correction
Resolved
02/16/2024
Remove all wood forms from touching the earth R408.5
All Rough Inspection - Residential Partial 3/1/2024 3/1/2024 03/01/2024
Misc
Informational
03/01/2024
—Portal frame inspection only—Passed
Erosion Control Inspection Residential Partial 3/12/2024 03/12/2024
Miscellaneous Correction
Informational
02/16/2024
Erosion control is in place at the time of sewer inspection. Full erosion control must be maintained until CofO
Miscellaneous Correction
Informational
02/16/2024
Full erosion is in place at the time of underground plumbing inspection. Full erosion cot must be maintained until CofO
Miscellaneous Correction
Informational
03/12/2024
Full erosion control is in place and must be maintained until CofO
Piers/Caissons Inspection - Residential Passed 3/20/2024 3/20/2024 03/20/2024
Miscellaneous Correction
Informational
03/20/2024
2 piers for back deck were inspected and passed. Holes are 18 x 48 deep
All Rough Inspection - Residential Failed 3/22/2024 3/22/2024 03/22/2024
Misc
Informational
03/01/2024
—Portal frame inspection only—Passed
Miscellaneous Correction
Corrective Action Required
03/22/2024
3832 SW Ravengate. All rough LIB in bathroom 2 needs nails Roof boots are missing Lateral support truss above kitchen to stairwell Nail primary bedroom corner to code IBeams in basement not properly supported at wall pockets One air supply line needs to be supported 10 feet on center This all rough is for the main house only. Exterior patio with roof will be inspected for all rough at a later date
Electrical Service Inspection Passed 3/22/2024 3/22/2024 03/22/2024
Gas Service Inspection - Residential Passed 3/22/2024 3/22/2024 03/22/2024
All Rough Inspection - Residential Failed 3/25/2024 3/26/2024 03/26/2024
Misc
Informational
03/22/2024
—Portal frame inspection only—Passed
Miscellaneous Correction
Resolved
03/26/2024
3832 SW Ravengate. All rough LIB in bathroom 2 needs nails Roof boots are missing Lateral support truss above kitchen to stairwell Nail primary bedroom corner to code IBeams in basement not properly supported at wall pockets One air supply line needs to be supported 10 feet on center This all rough is for the main house only. Exterior patio with roof will be inspected for all rough at a later date
Miscellaneous Correction
Corrective Action Required
03/26/2024
-Patio plans calls for a double 2x8 ridge beam to be installed -rafter to siding along south side needs to be installed to tie into the existing structure House all rough is completed and passed
All Rough Inspection - Residential Not Ready 3/29/2024 3/29/2024 03/29/2024
Misc
Informational
03/26/2024
—Portal frame inspection only—Passed
Miscellaneous Correction
Resolved
03/29/2024
-Patio plans calls for a double 2x8 ridge beam to be installed -rafter to siding along south side needs to be installed to tie into the existing structure House all rough is completed and passed
Miscellaneous Correction
Corrective Action Required
03/29/2024
Patio plans calls for a double 2x8 ridge beam to be installed. Double ridge beam is still not installed and or a design professional letter is not uploaded for design change 03/29/24 KBEARD. Not ready for inspection
Driveway Inspection Partial 4/8/2024 4/8/2024 04/08/2024
Misc
Informational
04/08/2024
4-8-24 Dustin A, DW is formed to city specs. Approved to pour
Sidewalk Inspection Partial 4/8/2024 4/8/2024 04/08/2024
Misc
Informational
04/08/2024
4-8-24 Dustin A, Sw is formed to city specs, Approved to pour
All Rough Inspection - Residential Passed 4/17/2024 4/17/2024 04/17/2024
Misc
Informational
03/29/2024
—Portal frame inspection only—Passed
Miscellaneous Correction
Resolved
04/17/2024
Patio plans calls for a double 2x8 ridge beam to be installed. Double ridge beam is still not installed and or a design professional letter is not uploaded for design change 03/29/24 KBEARD. Not ready for inspection
Miscellaneous Correction
Informational
04/17/2024
Third party passed the back porch ridge beam
Driveway Inspection Partial 4/17/2024 4/17/2024 04/17/2024
Misc
Informational
04/08/2024
4-8-24 Dustin A, DW is formed to city specs. Approved to pour 4-17-24 Dustin A. DW is poured to city specs, cannot pass until forms pulled
Sidewalk Inspection Partial 4/17/2024 4/17/2024 04/17/2024
Misc
Informational
04/08/2024
4-8-24 Dustin A, Sw is formed to city specs, Approved to pour 4-17-24 Dustin A. SW is poured to city specs, cannot pass until forms are pulled
Driveway Inspection Passed 5/9/2024 5/9/2024 05/09/2024
Misc
Informational
04/17/2024
4-8-24 Dustin A, DW is formed to city specs. Approved to pour 4-17-24 Dustin A. DW is poured to city specs, cannot pass until forms pulled 5-9-24 Dustin A, Passed
Sidewalk Inspection Passed 5/9/2024 5/9/2024 05/09/2024
Misc
Informational
04/17/2024
4-8-24 Dustin A, Sw is formed to city specs, Approved to pour 4-17-24 Dustin A. SW is poured to city specs, cannot pass until forms are pulled 5-9-24 Dustin A, Passed
Occupancy Inspection - Codes Residential Failed 5/13/2024 5/13/2024 05/13/2024
Miscellaneous Correction
Corrective Action Required
05/13/2024
3832 SW Ravengate. Occupancy -Kitchen receptacles are not installed at the backsplash -Seal all open penetrations in the garage -Electrical to HWT is not installed -Garage refrigerator needs to have a single dedicated receptacle -Sump pump extension is not installed -Sod and splash pads are not installed -Seal penetration in siding at gas line -Exterior grading has not been completed for a plot plan inspection
Plot Plan Inspection Failed 5/13/2024 05/13/2024
Miscellaneous Correction
Corrective Action Required
05/13/2024
Exterior grading has not been completed at the time of occupancy inspection
Occupancy Inspection - Codes Residential Failed 5/16/2024 5/16/2024 05/16/2024
Miscellaneous Correction
Resolved
05/16/2024
3832 SW Ravengate. Occupancy -Kitchen receptacles are not installed at the backsplash -Seal all open penetrations in the garage -Electrical to HWT is not installed -Garage refrigerator needs to have a single dedicated receptacle -Sump pump extension is not installed -Sod and splash pads are not installed -Seal penetration in siding at gas line -Exterior grading has not been completed for a plot plan inspection
Miscellaneous Correction
Corrective Action Required
05/16/2024
3832 SW Ravengate. Occupancy (2) -Kitchen receptacles are not installed at the backsplash (receptacles installed needs spark rings installed) -Electrical to HWT is not installed (installed electrical is in contact with water line) -Sump pump extension is not installed -Sod and splash pads are not installed -Seal penetration in siding at gas line -Exterior grading has not been completed for a plot plan inspection -Pay $75 fee associated with this permit
Occupancy Inspection - Codes Residential Ready for Temp CO 5/17/2024 05/17/2024
Miscellaneous Correction
Resolved
05/17/2024
3832 SW Ravengate. Occupancy (3) -Sump pump extension is not installed -Sod and splash pads are not installed -Seal penetration in siding at gas line -Exterior grading has not been completed for a plot plan inspection Okay for TCO only
Miscellaneous Correction
Corrective Action Required
05/17/2024
3832 SW Ravengate. Occupancy (3) -Sump pump extension is not installed -Sod and splash pads are not installed -Seal penetration in siding at gas line -Exterior grading has not been completed for a plot plan inspection -Plot plan must pass Okay for TCO only
Plot Plan Inspection Failed 5/17/2024 05/17/2024
Miscellaneous Correction
Resolved
05/17/2024
Exterior grading has not been completed at the time of occupancy inspection
Miscellaneous Correction
Corrective Action Required
05/17/2024
Exterior grading has not been completed at the time of occupancy inspection For TCO
Occupancy Inspection - Codes Residential Ready for Temp CO 6/27/2024 06/27/2024
Miscellaneous Correction
Resolved
06/27/2024
3832 SW Ravengate. Occupancy (3) -Sump pump extension is not installed -Sod and splash pads are not installed -Seal penetration in siding at gas line -Exterior grading has not been completed for a plot plan inspection -Plot plan must pass Okay for TCO only
Miscellaneous Correction
Corrective Action Required
06/27/2024
3832 SW Ravengate. Occupancy (3) -Sump pump extension is not installed -Sod and splash pads are not installed -Seal penetration in siding at gas line -Exterior grading has not been completed for a plot plan inspection -Plot plan must pass Okay for TCO only
Erosion Control Inspection Residential Partial 7/23/2024 07/23/2024
Miscellaneous Correction
Resolved
07/23/2024
Erosion control is in place at the time of sewer inspection. Full erosion control must be maintained until CofO
Miscellaneous Correction
Resolved
07/23/2024
Full erosion is in place at the time of underground plumbing inspection. Full erosion cot must be maintained until CofO
Miscellaneous Correction
Resolved
07/23/2024
Full erosion control is in place and must be maintained until CofO
Miscellaneous Correction
Informational
07/23/2024
Full erosion control is in place and must be maintained until CofO
Occupancy Inspection - Codes Residential Ready for Temp CO 7/23/2024 07/23/2024
Miscellaneous Correction
Resolved
07/23/2024
3832 SW Ravengate. Occupancy (3) -Sump pump extension is not installed -Sod and splash pads are not installed -Seal penetration in siding at gas line -Exterior grading has not been completed for a plot plan inspection -Plot plan must pass Okay for TCO only
Miscellaneous Correction
Informational
07/23/2024
Sump pump extension is not installed -Sod and splash pads are not installed -Seal penetration in siding at gas line -Exterior grading has not been completed for a plot plan inspection -Plot plan must pass Builder sent in a TCO extension form and stated that engineers are working on the final plot grading.
Occupancy Inspection - Codes Residential Ready for Temp CO 8/23/2024 08/23/2024
Miscellaneous Correction
Informational
07/23/2024
Sump pump extension is not installed -Sod and splash pads are not installed -Seal penetration in siding at gas line -Exterior grading has not been completed for a plot plan inspection -Plot plan must pass This is the third TCO extension for this permit. Builder sent in another TCO extension form. A drive by inspection was done and this property has workers trying to finish up the exterior so an occupancy inspection can be called in.
Erosion Control Inspection Residential Passed 8/29/2024 08/29/2024
Miscellaneous Correction
Resolved
08/29/2024
Full erosion control is in place and must be maintained until CofO
Plot Plan Inspection Passed 8/30/2024 08/30/2024
Miscellaneous Correction
Resolved
08/30/2024
Exterior grading has not been completed at the time of occupancy inspection For TCO
Occupancy Inspection - Codes Residential Failed 8/30/2024 8/30/2024 08/30/2024
Miscellaneous Correction
Resolved
08/30/2024
Sump pump extension is not installed -Sod and splash pads are not installed -Seal penetration in siding at gas line -Exterior grading has not been completed for a plot plan inspection -Plot plan must pass This is the third TCO extension for this permit. Builder sent in another TCO extension form. A drive by inspection was done and this property has workers trying to finish up the exterior so an occupancy inspection can be called in.
Miscellaneous Correction
Corrective Action Required
08/30/2024
Sod to siding in the backyard on the North side of the porch does not have the required 4 inch minimum height clearance
Occupancy Inspection - Codes Residential Not Ready 9/10/2024 9/10/2024 09/10/2024
Miscellaneous Correction
Corrective Action Required
08/30/2024
Sod to siding in the backyard on the West side of the porch does not have the required 4 inch minimum height clearance (No improvements have been made since last inspection. WALK YOUR PROPERTY before scheduling inspections) Pay $125 in fees associated with this permit
Occupancy Inspection - Codes Residential Failed 9/17/2024 09/17/2024
Miscellaneous Correction
Corrective Action Required
09/10/2024
Sod to siding in the backyard on the West side of the porch does not have the required 4 inch minimum height clearance (No improvements have been made since last inspection. WALK YOUR PROPERTY before scheduling inspections) Pay $125 in fees associated with this permit
Occupancy Inspection - Codes Residential Full C of O 10/10/2024 10/10/2024 10/10/2024
Miscellaneous Correction
Resolved
10/10/2024
Sod to siding in the backyard on the West side of the porch does not have the required 4 inch minimum height clearance (No improvements have been made since last inspection. WALK YOUR PROPERTY before scheduling inspections) Pay $125 in fees associated with this permit
Documents & Images
Date Uploaded File Type Document Name
12/21/2023 Permit Codes Residential Plan Review
12/22/2023 Plot Plan approved plot plan
12/22/2023 Permit Codes Residential Plan Review
01/02/2024 Permit Codes Residential Plan Review
01/02/2024 OS # 67 - PERMIT APP
01/02/2024 Approved Plans APPROVED PLANS
01/02/2024 Approved Plans APPROVED TRUSS PACKAGE
01/02/2024 Approved Plans APPROVED TRUSS LAYOUT
01/02/2024 Permit Codes Residential Plan Review
01/02/2024 Permit DS Building Permit
01/02/2024 Receipt Receipt for transaction:2024-000013
01/04/2024 M L Crose 3832 SW Raven Gate Pl LSMO Osage Lot 67 LSMO Clayton P 2023-6605 3rd Party Footing Inspection Report 1-3-23
01/04/2024 Letter INSPECTION SUMMARY
01/04/2024 Letter INSPECTION SUMMARY
02/09/2024 Letter INSPECTION SUMMARY
02/09/2024 Letter INSPECTION SUMMARY
02/09/2024 Letter INSPECTION SUMMARY
02/12/2024 Letter INSPECTION SUMMARY
02/15/2024 Letter INSPECTION SUMMARY
02/15/2024 Letter INSPECTION SUMMARY
02/16/2024 Letter INSPECTION SUMMARY
02/16/2024 Letter INSPECTION SUMMARY
02/16/2024 Letter INSPECTION SUMMARY
03/12/2024 Letter INSPECTION SUMMARY
03/12/2024 Letter INSPECTION SUMMARY
03/20/2024 OS 67 - WILDFLOWER - 240319
03/20/2024 Approved Plans APPROVED PLANS - COVERED PATIO SHEETS
03/20/2024 Letter INSPECTION SUMMARY
03/22/2024 Letter INSPECTION SUMMARY
03/22/2024 Letter INSPECTION SUMMARY
03/22/2024 Letter INSPECTION SUMMARY
03/26/2024 Letter INSPECTION SUMMARY
03/29/2024 Letter INSPECTION SUMMARY
04/08/2024 Letter INSPECTION SUMMARY
04/08/2024 Letter INSPECTION SUMMARY
04/16/2024 3RD Party Insp Report THIRD PARTY INSPECTION
04/17/2024 Letter INSPECTION SUMMARY
04/17/2024 Letter INSPECTION SUMMARY
04/17/2024 Letter INSPECTION SUMMARY
05/09/2024 Letter INSPECTION SUMMARY
05/09/2024 Letter INSPECTION SUMMARY
05/09/2024 Letter INSPECTION SUMMARY
05/13/2024 Letter INSPECTION SUMMARY
05/13/2024 Letter INSPECTION SUMMARY
05/13/2024 Letter INSPECTION SUMMARY
05/16/2024 Letter INSPECTION SUMMARY
05/17/2024 Receipt Receipt for transaction:2024-003592
05/17/2024 Letter INSPECTION SUMMARY
05/17/2024 Certificate/License Codes Temporary Certificate of Occupancy
05/17/2024 Receipt Receipt for transaction:2024-003632
06/12/2024 OS #67 - TCO Extension Form 6_12_24
06/27/2024 Letter INSPECTION SUMMARY
06/27/2024 Certificate/License Codes Temporary Certificate of Occupancy
06/27/2024 Receipt Receipt for transaction:2024-005279
07/22/2024 OS #67 - TCO Extension Form 7_22_24
07/23/2024 Letter INSPECTION SUMMARY
07/23/2024 Letter INSPECTION SUMMARY
07/23/2024 Certificate/License Codes Temporary Certificate of Occupancy
07/23/2024 Receipt Receipt for transaction:2024-006131
08/23/2024 Application Form OS 67 TCOExtension Request Form 8_23
08/23/2024 Letter INSPECTION SUMMARY
08/29/2024 Letter INSPECTION SUMMARY
08/30/2024 Letter INSPECTION SUMMARY
08/30/2024 Letter INSPECTION SUMMARY
09/10/2024 Letter INSPECTION SUMMARY
09/17/2024 Letter INSPECTION SUMMARY
09/17/2024 OS 67 TCOExtension Request Form 9_17
09/17/2024 Certificate/License Codes Temporary Certificate of Occupancy
09/17/2024 Receipt Receipt for transaction:2024-007739
10/10/2024 Letter Codes Final Certificate of Occupancy
10/10/2024 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home