Permit Application Status

PRRES20234908


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20234908
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED DECK
09/26/2023
09/29/2023
08/14/2024
Locations
Contacts
WALKER CUSTOM HOMES, LLC, Address:PO BOX 3194, Phone:(913) 208-2026  
Jason walker, Address:PO Box 247, Phone:(913) 208-2026  
WALKERCUSTOMHOMESKC@GMAIL.COM  
5 STAR MECHANICAL, LLC, Address:PO BOX 793, Phone:(816) 679-0375  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 09/29/2023
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 09/29/2023
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 09/29/2023
8331401-Water Tap Fee $3,760.00 $3,760.00 Paid 09/29/2023
8350015-Water Meter Fee $680.46 $680.46 Paid 09/29/2023
9110078-Valuation Fee New Single Family $1,554.27 $1,554.27 Paid 09/29/2023
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 08/08/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sewer Service Inspection - R Passed 11/15/2023 11/15/2023
Footing Inspection - Residential Passed 11/15/2023 11/15/2023
Water Service Inspection - R Passed 11/17/2023 11/17/2023
Underslab Plumbing Inspection - Residential Passed 11/20/2023 11/20/2023 11/20/2023
All Rough Inspection - Residential Failed 1/2/2024 1/2/2024 01/02/2024
Misc
Corrective Action Required
01/02/2024
Garage portal frame inspection only -nailing incomplete and spacing incorrect
Erosion Control Inspection Residential Failed 1/2/2024 1/2/2024 01/02/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
01/02/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Clean trash and debris from lot
All Rough Inspection - Residential Failed 3/14/2024 3/14/2024 03/14/2024
Misc
Corrective Action Required
01/02/2024
Garage portal frame inspection only -nailing incomplete and spacing incorrect
Misc
Corrective Action Required
03/14/2024
-garage portal frame did not pass previous inspection see above note -anchor bolts to be in the middle 1/3 of sill plate (garage and basement) -3 studs required at exterior wall corners see SE garage wall -fire block top plate penetrations in garage S wall -address cut ceiling joist above pantry -address ceiling joists running wrong direction above garage entry area, pantry, laundry -windows in dining room will need to be tempered at occupancy stage -address over span header above master bedroom window -address 3/4 osb used as shim under roof supports for bed 2 -address notched floor joists above bed 4 for shower above -provide support for furr down ceiling joists to floor joist above -exterior wall corners at basement 3 studs required (wall corners not tied together) -all 2x6 walls shall have double king studs at door and window openings per plans
Electrical Service Inspection Passed 3/14/2024 3/14/2024 03/14/2024
Gas Service Inspection - Residential Passed 3/14/2024 3/14/2024 03/14/2024
All Rough Inspection - Residential Not Ready 4/5/2024 4/5/2024 04/05/2024
Misc
Corrective Action Required
03/14/2024
Garage portal frame inspection only -nailing incomplete and spacing incorrect
Misc
Corrective Action Required
03/14/2024
-garage portal frame did not pass previous inspection see above note Can not confirm nailing. Along sides -address cut ceiling joist above pantry (provide plans on site to inspect) -address ceiling joists running wrong direction above garage entry area, pantry, laundry (provide plans on site to address fix) -windows in dining room will need to be tempered at occupancy stage -address over span header above master bedroom window -address notched floor joists above bed 4 for shower above floor joist may not be notched more than 1/6 of the joist -exterior wall corners at basement 3 studs required (wall corners not tied together) -all 2x6 walls shall have double king studs at door and window openings per plans
All Rough Inspection - Residential Failed 5/7/2024 5/7/2024 05/07/2024
Misc
Corrective Action Required
04/05/2024
Garage portal frame inspection only -nailing incomplete and spacing incorrect
Misc
Corrective Action Required
04/05/2024
-garage portal frame did not pass previous inspection see above note Can not confirm nailing. -all 2x6 walls shall have double king studs at door and window openings per plans (address cut header at front door now missing jack studs while trying to add king studs. ) Do not insulate
All Rough Inspection - Residential Failed 5/13/2024 5/13/2024 05/13/2024
Misc
Resolved
05/13/2024
Garage portal frame inspection only -nailing incomplete and spacing incorrect
Misc
Corrective Action Required
05/07/2024
-all 2x6 walls shall have double king studs at door and window openings per plans (address cut header and over notched king studs at front door now missing jack studs while trying to add king studs. ) Do not insulate
All Rough Inspection - Residential Passed 5/16/2024 5/16/2024 05/16/2024
Misc
Resolved
05/16/2024
-all 2x6 walls shall have double king studs at door and window openings per plans (address cut header and over notched king studs at front door now missing jack studs while trying to add king studs. ) Do not insulate
Driveway Inspection Partial 5/22/2024 5/22/2024 05/22/2024
Misc
Informational
05/22/2024
5-22-24 Dustin A, Dw is formed and compacted to city specs. Approved to pour
Sidewalk Inspection Partial 5/22/2024 5/22/2024 05/22/2024
Misc
Informational
05/22/2024
5-22-24 Dustin A, SW is formed and compacted to city specs. Approved to pour
Driveway Inspection Passed 5/29/2024 5/29/2024 05/29/2024
Misc
Informational
05/22/2024
5-22-24 Dustin A, Dw is formed and compacted to city specs. Approved to pour 5-29-24 Dustin A, Dw is poured to city specs. Passed
Sidewalk Inspection Passed 5/29/2024 5/29/2024 05/29/2024
Misc
Informational
05/22/2024
5-22-24 Dustin A, SW is formed and compacted to city specs. Approved to pour 5-29-24 Dustin A, SW is poured to city specs, Passed
Plot Plan Inspection Passed 7/11/2024 07/11/2024
Erosion Control Inspection Residential Failed 07/11/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
07/11/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Clean trash and debris from lot
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
07/11/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Maintain silt fence and overgrown vegetation Clean sidewalk
Erosion Control Inspection Residential Passed 08/14/2024
DCM3 ESC REQUIRED 2 DAY
Resolved
08/14/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Maintain silt fence and overgrown vegetation Clean sidewalk
Occupancy Inspection - Codes Residential Full C of O 8/14/2024 8/14/2024 08/14/2024
Documents & Images
Date Uploaded File Type Document Name
09/26/2023 2143 Hook Farm Dr City Application
09/26/2023 HKF109 Spec - Sealed Plans (September 21, 2023)
09/26/2023 LOT 109 FINAL SURVEY
09/29/2023 Approved Plans approved plans
09/29/2023 Plot Plan approved plot plan
09/29/2023 Permit Codes Residential Plan Review
09/29/2023 Permit DS Building Permit
09/29/2023 Receipt Receipt for transaction:2023-007423
11/15/2023 Wilmoth 2143 SW Hook Farm Dr LSMO Hook Farms Lot 109 3rd Party Footing Inspection Report 11-9-23
11/15/2023 Letter INSPECTION SUMMARY
11/17/2023 Letter INSPECTION SUMMARY
11/17/2023 Letter INSPECTION SUMMARY
11/20/2023 Letter INSPECTION SUMMARY
12/01/2023 Final_2023_11_30_DPier_Raymore_Pat Cochran Concrete
01/02/2024 Letter INSPECTION SUMMARY
01/02/2024 Letter INSPECTION SUMMARY
03/14/2024 Letter INSPECTION SUMMARY
03/14/2024 Letter INSPECTION SUMMARY
03/14/2024 Letter INSPECTION SUMMARY
04/05/2024 Letter INSPECTION SUMMARY
04/24/2024 HKF109 - Inspection Letter (April 23, 2024)
05/07/2024 Letter INSPECTION SUMMARY
05/16/2024 Letter INSPECTION SUMMARY
05/16/2024 Letter INSPECTION SUMMARY
05/22/2024 Letter INSPECTION SUMMARY
05/22/2024 Letter INSPECTION SUMMARY
05/22/2024 Letter INSPECTION SUMMARY
05/29/2024 Letter INSPECTION SUMMARY
05/29/2024 Letter INSPECTION SUMMARY
07/10/2024 Plot Plan approved as graded plot plan
07/11/2024 Letter INSPECTION SUMMARY
07/11/2024 Letter INSPECTION SUMMARY
08/08/2024 Receipt Receipt for transaction:2024-006711
08/14/2024 Letter Codes Final Certificate of Occupancy
08/14/2024 Letter Field Certificate of Occupancy
08/14/2024 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home