PRRES20233425


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20233425
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. WALK OUT BASEMENT. FINISHED/UNFINISHED BASEMENT. COVERED DECK. SUSPENDED STOOP. STOP WORK ORDER generated on 04/25/2024 12:00 AM by username 'Dustin Agcopra'. STOP WORK ORDER removed on 04/25/2024 12:00 AM by username 'Dustin Agcopra'.
07/14/2023
07/20/2023
01/16/2024
05/16/2024
Locations
Contacts
WALKER CUSTOM HOMES, LLC, Address:PO BOX 3194, Phone:(913) 208-2026  
Jason walker, Address:PO Box 247, Phone:(913) 208-2026  
5 STAR HEATING & COOLING, Address:211 NW 12TH, Phone:(816) 517-3341  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
WALKERCUSTOMHOMESKC@GMAIL.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331401-Water Tap Fee $3,760.00 $3,760.00 Paid 07/20/2023
8350015-Water Meter Fee $680.46 $680.46 Paid 07/20/2023
8331507-Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 07/20/2023
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 07/20/2023
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 07/20/2023
9110078-Valuation Fee New Single Family $1,702.46 $1,702.46 Paid 07/20/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 05/15/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 08/08/2023
Sewer Service Inspection - R Passed 8/10/2023 (11:15) 8/10/2023 08/10/2023
Water Service Inspection - R Partial 8/10/2023 8/10/2023 08/10/2023
Water Service Inspection - R Passed 8/11/2023 8/11/2023 08/11/2023
Underslab Plumbing Inspection - Residential Passed 8/18/2023 8/18/2023 08/18/2023
Electrical Service Inspection Passed 12/21/2023 12/21/2023 12/21/2023
Gas Service Inspection - Residential Passed 12/21/2023 12/21/2023 12/21/2023
All Rough Inspection - Residential Failed 12/21/2023 12/21/2023 12/21/2023
Misc
Corrective Action Required
12/21/2023
Provide CITY STAMPED plans on site for inspection.
All Rough Inspection - Residential Failed 12/28/2023 12/28/2023 12/28/2023
Misc
Resolved
12/28/2023
Misc
Corrective Action Required
12/28/2023
-Anchor bolts in garage not in center 1/3 -Missing snow blocking in garage north west wall -Missing joist hanger in laundry -Missing collar ties bedroom 2 -Missing fire blocking top plate south wall basement bathroom -Missing joist hangers at deck -Secure NM cable at right side at fireplace
All Rough Inspection - Residential Passed 1/18/2024 1/18/2024 01/18/2024
Misc
Resolved
01/18/2024
Erosion Control Inspection Residential Failed 02/06/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/06/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Maintain erosion control at front of lot -Maintain erosion control at storm inlet -Clean trash and debris from lot and surrounding
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/06/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Driveway Inspection Partial 3/4/2024 03/04/2024
Misc
Informational
03/04/2024
3-4-24 Dustin A, DW is formed and compacted. Approved to pour
Driveway Inspection Passed 3/11/2024 3/11/2024 03/11/2024
Misc
Informational
03/04/2024
3-4-24 Dustin A, DW is formed and compacted. Approved to pour 3-11-24 Dustin A,Dw is poured to city specs. Passed
Sidewalk Inspection Partial 4/10/2024 4/10/2024 04/10/2024
Misc
Informational
04/10/2024
4-10-24 Dustin A, Sw is formed to city specs, approved to pour
Sidewalk Inspection Passed 4/17/2024 4/17/2024 04/17/2024
Misc
Informational
04/10/2024
4-10-24 Dustin A, Sw is formed to city specs, approved to pour 4-17-24 Dustin A. Sw is poured to city specs, Passed
Erosion Control Inspection Residential Passed 04/25/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/06/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Maintain erosion control at front of lot -Maintain erosion control at storm inlet -Clean trash and debris from lot and surrounding
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/06/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/25/2024
4-25-24 Dustin A, EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Occupancy Inspection - Codes Residential Failed 5/10/2024 5/10/2024 05/10/2024
Miscellaneous Correction
Corrective Action Required
05/10/2024
2735 SW Heartland rd. Occupancy - Exterior lights are not completed Address numbers are not properly illuminated -Tamper resistant receptacles are not installed throughout NEC 406.12(1) -Overhead light is not installed in the utility room -Seal all garage ceiling penetrations -Second step to the top step at main floor has a greater than 3/8 on an inch code required difference -Furnace humidifier receptacle needs to state it is non GFCI protected -Back deck post to beam connection needs two all through bolts installed -Secure electrical whip at exterior A/C unit within 12 inches of disconnect -Seal top of A/C disconnect -Sod and splash pads are not installed -Not a complete list. Lot grading was not completed at the time of occupancy inspection
Occupancy Inspection - Codes Residential Ready for Temp CO 5/15/2024 5/15/2024 05/15/2024
Miscellaneous Correction
Corrective Action Required
05/10/2024
-tempered glass for dining room windows -Secure electrical whip at exterior A/C unit within 12 inches of disconnect -Seal top of A/C disconnect -Sod and splash pads are not installed -Not a complete list. Lot grading was not completed at the time of occupancy inspection
Plot Plan Inspection Passed 5/15/2024 05/15/2024
Erosion Control Inspection Residential Passed 05/16/2024
DCM2 ESC DEFICIENT INSTALLATION
Resolved
05/16/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Maintain erosion control at front of lot -Maintain erosion control at storm inlet -Clean trash and debris from lot and surrounding
DCM3 ESC REQUIRED 2 DAY
Resolved
05/16/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
05/16/2024
4-25-24 Dustin A, EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Occupancy Inspection - Codes Residential Full C of O 5/16/2024 5/16/2024 05/16/2024
Miscellaneous Correction
Resolved
05/16/2024
-tempered glass for dining room windows -Secure electrical whip at exterior A/C unit within 12 inches of disconnect -Seal top of A/C disconnect -Sod and splash pads are not installed -Not a complete list. Lot grading was not completed at the time of occupancy inspection
Documents & Images
Date Uploaded File Type Document Name
07/14/2023 2735 SW Heartland Signed City Application
07/19/2023 Permit Codes Residential Plan Review
07/20/2023 Permit Codes Residential Plan Review
07/20/2023 Updated Cty Application
07/20/2023 Approved Plans APPROVED PLANS
07/20/2023 Plot Plan APPROVED PLOT PLAN
07/20/2023 Permit Codes Residential Plan Review
07/20/2023 Permit DS Building Permit
07/20/2023 Receipt Receipt for transaction:2023-005642
08/04/2023 Wilmoth 2735 SW Heartland Rd LSMO Hook Farms Lot 192 Footing Inspection Report 8-3-23
08/08/2023 Letter INSPECTION SUMMARY
08/10/2023 Letter INSPECTION SUMMARY
08/10/2023 Letter INSPECTION SUMMARY
08/11/2023 Letter INSPECTION SUMMARY
08/18/2023 Letter INSPECTION SUMMARY
09/15/2023 Final_2023_08_29_DPier_LSMO_Pat Cochran Concrete
12/21/2023 Letter INSPECTION SUMMARY
12/21/2023 Letter INSPECTION SUMMARY
12/21/2023 Letter INSPECTION SUMMARY
12/28/2023 Letter INSPECTION SUMMARY
01/18/2024 Letter INSPECTION SUMMARY
02/06/2024 Letter INSPECTION SUMMARY
02/06/2024 Letter INSPECTION SUMMARY
03/04/2024 Letter INSPECTION SUMMARY
03/11/2024 Letter INSPECTION SUMMARY
04/10/2024 Letter INSPECTION SUMMARY
04/17/2024 Letter INSPECTION SUMMARY
04/25/2024 Letter Stop Work Order
04/25/2024 Letter Stop Work Order
04/25/2024 Letter INSPECTION SUMMARY
05/10/2024 Letter INSPECTION SUMMARY
05/14/2024 Plot Plan APPROVED AS BUILT PLOT PLAN
05/15/2024 Letter INSPECTION SUMMARY
05/15/2024 Certificate/License Codes Temporary Certificate of Occupancy
05/15/2024 Receipt Receipt for transaction:2024-003515
05/16/2024 safety glazing
05/16/2024 Letter INSPECTION SUMMARY
05/16/2024 Letter Field Certificate of Occupancy
05/16/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.