Summary
PRRES20233281
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED DECK
07/07/2023
07/20/2023
01/15/2024
04/25/2024
Locations
Contacts
NEW MARK HOMES - KC LLC, Address:5207 NW CROOKED ROAD, Phone:(816) 969-9010  
Ashley Kirby, Address:5207 NW Crooked Rd, Phone:(816) 969-9010  
ASHLEY@NEWMARKHOMESKC.COM  
HARRINGTON BROTHERS HEATING & COOLING, Address:15630 S KEELER ST, Phone:(913) 422-5444  
PREMIER ELECTRIC & LIGHTING DESIGN, Address:PO BOX 1311, Phone:(816) 564-7660  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 07/20/2023
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 07/20/2023
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 07/20/2023
8331401-Water Tap Fee $3,760.00 $3,760.00 Paid 07/20/2023
8350015-Water Meter Fee $680.46 $680.46 Paid 07/20/2023
9110078-Valuation Fee New Single Family $2,819.08 $2,819.08 Paid 07/20/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 04/17/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 8/15/2023 (2:30) 8/15/2023 08/15/2023
Underslab Plumbing Inspection - Residential Passed 8/24/2023 8/24/2023 08/24/2023
Sewer Service Inspection - R Passed 9/12/2023 9/12/2023 09/12/2023
Water Service Inspection - R Passed 9/13/2023 (10:00) 9/13/2023 09/13/2023
Erosion Control Inspection Residential Failed 9/22/2023 09/22/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
09/22/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Partial 9/27/2023 9/27/2023 09/27/2023
DCM3 ESC REQUIRED 2 DAY
Resolved
09/27/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
All Rough Inspection - Residential Failed 10/9/2023 10/9/2023 10/09/2023
Misc
Corrective Action Required
10/09/2023
Garage portal frame inspected only. Nail sill plate to sheathing.
Erosion Control Inspection Residential Failed 10/9/2023 10/09/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
10/09/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
10/09/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
All Rough Inspection - Residential Partial 10/20/2023 10/20/2023 10/20/2023
Misc
Corrective Action Required
10/09/2023
Garage portal frame inspected only.
All Rough Inspection - Residential Failed 12/12/2023 12/12/2023 12/12/2023
Misc
Resolved
12/12/2023
Garage portal frame inspected only.
Misc
Corrective Action Required
12/12/2023
Fireblock top of plumbing furr out in garage to ceiling space -vent bath fans through out -address holes drilled for pex closer than 2” to one another at garage/pantry -fire block SW living room corner wall space to ceiling space -fire block wall space to ceiling space in master bathroom toilet room plumbing chase -seal penetrations in return air joist space above laundry -front entry door to be framed to plans (3) 2x6 full height each side -provide proper bearing for valley rafter above bed 2 closet -fire block to be of approved materials
Gas Service Inspection - Residential Passed 12/12/2023 12/12/2023 12/12/2023
Electrical Service Inspection Passed 12/12/2023 12/12/2023 12/12/2023
All Rough Inspection - Residential Passed 12/15/2023 12/15/2023 12/15/2023
Misc
Resolved
12/15/2023
Fireblock top of plumbing furr out in garage to ceiling space -vent bath fans through out -address holes drilled for pex closer than 2” to one another at garage/pantry -fire block SW living room corner wall space to ceiling space -fire block wall space to ceiling space in master bathroom toilet room plumbing chase -seal penetrations in return air joist space above laundry -front entry door to be framed to plans (3) 2x6 full height each side -provide proper bearing for valley rafter above bed 2 closet -fire block to be of approved materials
Driveway Inspection Partial 1/29/2024 01/29/2024
Misc
Informational
01/29/2024
1-29-24 Dustin A, DW is formed and aggregate is compacted. Slopes are in compliance approved to pour
Sidewalk Inspection Partial 1/29/2024 01/29/2024
Misc
Informational
01/29/2024
1-29-24 Dustin A, SW is formed and aggregate is compacted. slopes are in compliance approved to pour
Driveway Inspection Passed 2/6/2024 2/6/2024 02/06/2024
Misc
Informational
01/29/2024
1-29-24 Dustin A, DW is formed and aggregate is compacted. Slopes are in compliance approved to pour 2-6-24 Dustin A, Dw is poured, slopes are in compliance with city specs. Passed
Sidewalk Inspection Passed 2/6/2024 02/06/2024
Misc
Informational
01/29/2024
1-29-24 Dustin A, SW is formed and aggregate is compacted. slopes are in compliance approved to pour 2-6-24 Dustin A, SW is poured. Slopes are in compliance with city specs. Passed
Erosion Control Inspection Residential Failed 2/6/2024 02/06/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
02/06/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM3 ESC REQUIRED 2 DAY
Resolved
02/06/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/06/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. Missing silt fence at front of lot.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/06/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Occupancy Inspection - Codes Residential Failed 4/9/2024 4/9/2024 04/09/2024
Misc
Corrective Action Required
04/09/2024
-provide as graded plot plan -obtain issued lawn irrigation permit -water meter to be 14”-18” from top of meter to well lid ring -Obtain vegetation in swale at rear of lot
Plot Plan Inspection Passed 4/17/2024 04/17/2024
Occupancy Inspection - Codes Residential Ready for Temp CO 4/17/2024 04/17/2024
Misc
Corrective Action Required
04/09/2024
-obtain issued lawn irrigation permit -water meter to be 14”-18” from top of meter to well lid ring -Obtain vegetation in swale at rear of lot and remove silt fence
Erosion Control Inspection Residential Passed 04/25/2024
DCM2 ESC DEFICIENT INSTALLATION
Resolved
04/25/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. Missing silt fence at front of lot.
DCM3 ESC REQUIRED 2 DAY
Resolved
04/25/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Occupancy Inspection - Codes Residential Full C of O 4/25/2024 4/25/2024 04/25/2024
Misc
Resolved
04/25/2024
-obtain issued lawn irrigation permit -water meter to be 14”-18” from top of meter to well lid ring -Obtain vegetation in swale at rear of lot and remove silt fence
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide: