Permit Application Status

PRRES20231605


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20231605
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. WALKOUT BASEMENT. COVERED DECK. STOP WORK ORDER generated on 04/28/2023 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 05/09/2023 12:00 AM by username 'Mitchell Schwarz'.
04/12/2023
04/19/2023
10/14/2023
03/25/2024
Locations
Contacts
WALKER CUSTOM HOMES, LLC, Address:PO BOX 3194, Phone:(913) 208-2026  
Jason walker, Address:PO Box 247, Phone:(913) 208-2026  
5 STAR HEATING & COOLING, Address:211 NW 12TH, Phone:(816) 517-3341  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
WALKERCUSTOMHOMESKC@GMAIL.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331401-Water Tap Fee $3,730.00 $3,730.00 Paid 04/19/2023
8350015-Water Meter Fee $550.50 $550.50 Paid 04/19/2023
8331507-Sanitary Sewer Development Fee $1,384.00 $1,384.00 Paid 04/19/2023
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 04/19/2023
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 04/19/2023
9110078-Valuation Fee New Single Family $1,835.37 $1,835.37 Paid 04/19/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 01/26/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 02/27/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Failed 4/28/2023 04/28/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/28/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Footing Inspection - Residential Failed - Stop Work 4/28/2023 04/28/2023
Misc
Corrective Action Required
04/28/2023
STOP WORK ISSUED Footing poured without inspection No erosion control in place at time of footing pour.
Erosion Control Inspection Residential Failed - Stop Work 5/2/2023 5/2/2023 05/02/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/28/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Corrective Action Required
05/02/2023
Must contact Building inspection manager Mark Harding to lift stop work order.
Erosion Control Inspection Residential Passed 5/9/2023 05/09/2023
DCM3 ESC REQUIRED 2 DAY
Resolved
05/09/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Resolved
05/09/2023
Must contact Building inspection manager Mark Harding to lift stop work order.
Sewer Service Inspection - R Passed 5/11/2023 (8:00) 5/11/2023 05/11/2023
Footing Inspection - Residential Passed 5/11/2023 05/11/2023
Misc
Resolved
05/11/2023
STOP WORK ISSUED Footing poured without inspection No erosion control in place at time of footing pour.
Water Service Inspection - R Passed 5/12/2023 5/12/2023 05/12/2023
Underslab Plumbing Inspection - Residential Passed 5/15/2023 5/15/2023 05/15/2023
All Rough Inspection - Residential Failed 8/30/2023 8/30/2023 08/30/2023
Misc
Corrective Action Required
08/30/2023
-address rafter bearing not to plans -seal bottom plate penetration at garage entry -most exterior double lvl at covered patio plans call to be continuous to corner -missing nail in hanger for double ceiling joist above kitchen -holes drilled to close together in 4 2x10 above master bath -top plate penetration bed 2 for low voltage near closet -fire block top for furr out wall in 2nd story bed 2/3 bath -secure all 2” or less dwv in stud bays SECURELY current straps are not tight enough in some areas -attic access for 2nd story -missing double 2x10 SE of west most D column -seal penetrations into return air joist space panning In mechanical area of basement -
Electrical Service Inspection Passed 8/30/2023 8/30/2023 08/30/2023
Gas Service Inspection - Residential Passed 8/30/2023 8/30/2023 08/30/2023
All Rough Inspection - Residential Passed 9/15/2023 9/15/2023 09/15/2023
Misc
Resolved
09/15/2023
-seal bottom plate penetration at garage entry -most exterior double lvl at covered patio plans call to be continuous to corner -missing nail in hanger for double ceiling joist above kitchen -holes drilled to close together in 4 2x10 above master bath -top plate penetration bed 2 for low voltage near closet -fire block top for furr out wall in 2nd story bed 2/3 bath -secure all 2” or less dwv in stud bays SECURELY current straps are not tight enough in some areas -attic access for 2nd story -missing double 2x10 SE of west most D column -seal penetrations into return air joist space panning In mechanical area of basement -
Driveway Inspection Partial 10/4/2023 10/04/2023
Misc
Informational
10/04/2023
10-4-23 Dustin A, DW is formed , Aggregate is compacted and slopes are in compliance. will need to maintain ada slopes through approach. Approved to pour
Sidewalk Inspection Partial 10/4/2023 10/04/2023
Misc
Informational
10/04/2023
10-4-23 Dustin A, SW is formed , Aggregate is compacted and slopes are in compliance. Approved to pour
Driveway Inspection Passed 10/11/2023 10/11/2023 10/11/2023
Misc
Informational
10/04/2023
10-4-23 Dustin A, DW is formed , Aggregate is compacted and slopes are in compliance. will need to maintain ada slopes through approach. Approved to pour 10-11-23 Dustin A, DW is poured. Forms are pulled. Slopes are in compliance . Passed
Sidewalk Inspection Passed 10/11/2023 10/11/2023 10/11/2023
Misc
Informational
10/11/2023
10-4-23 Sw is framed. Gravel is compacted and depth is in compliance. Approved to pour. 10-11-23 SW is poured . Frame are pulled. Slopes are in compliance. Passed
Occupancy Inspection - Codes Residential Ready for Temp CO 1/26/2024 1/26/2024 01/26/2024
Misc
Corrective Action Required
01/26/2024
No further inspections until sod is in place -provide as graded plot plan -sod -splash blocks and sump pump discharge to extend 36” from foundation -obtain lawn irrigation permit issued Will check water meter and exterior penetrations at time of sod
Erosion Control Inspection Residential Failed 1/26/2024 01/26/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
01/26/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
01/26/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Plot Plan Inspection Passed 2/23/2024 02/23/2024
Occupancy Inspection - Codes Residential Ready for Temp CO 2/27/2024 02/27/2024
Misc
Corrective Action Required
01/26/2024
No further inspections until sod or erosion control is in place -provide as graded plot plan -sod -splash blocks and sump pump discharge to extend 36” from foundation -obtain lawn irrigation permit issued Will check water meter and exterior penetrations at time of sod TCO extension 02/27/2024
Erosion Control Inspection Residential Passed 03/18/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
03/18/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM3 ESC REQUIRED 2 DAY
Resolved
03/18/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Occupancy Inspection - Codes Residential Failed 3/18/2024 3/18/2024 03/18/2024
Misc
Corrective Action Required
02/27/2024
-obtain lawn irrigation permit TCO extension 02/27/2024
Occupancy Inspection - Codes Residential Full C of O 3/26/2024 3/26/2024 03/25/2024
Misc
Resolved
03/25/2024
-obtain lawn irrigation permit TCO extension 02/27/2024
Documents & Images
Date Uploaded File Type Document Name
04/12/2023 City Permit docs signed
04/17/2023 Approved Plans APPROVED PLANS
04/17/2023 Permit Codes Residential Plan Review
04/19/2023 Plot Plan APPROVED PLOT PLAN
04/19/2023 Permit Codes Residential Plan Review
04/19/2023 Permit DS Building Permit
04/19/2023 Receipt Receipt for transaction:2023-002225
04/28/2023 Letter INSPECTION SUMMARY
04/28/2023 Letter Stop Work Order
04/29/2023 Wilmoth 2215 SW Hook Farms Drl LSMO Subgrade & Footing Inspection Report 4-28-23
05/01/2023 20230501_094908
05/01/2023 20230501_094958
05/01/2023 20230501_094823
05/09/2023 Letter Stop Work Order
05/09/2023 Letter INSPECTION SUMMARY
05/11/2023 Letter INSPECTION SUMMARY
05/11/2023 Letter INSPECTION SUMMARY
05/12/2023 Letter INSPECTION SUMMARY
05/15/2023 Letter INSPECTION SUMMARY
07/25/2023 Final_2023_06_08_DPier_LSMO_Pat Cochran Concrete
08/30/2023 Letter INSPECTION SUMMARY
08/30/2023 Letter INSPECTION SUMMARY
08/30/2023 Letter INSPECTION SUMMARY
09/14/2023 HKF114 - Inspection Letter (September 13, 2023) 2215 Hook Farms
09/15/2023 Letter INSPECTION SUMMARY
10/04/2023 Letter INSPECTION SUMMARY
10/04/2023 Letter INSPECTION SUMMARY
10/11/2023 Letter INSPECTION SUMMARY
10/11/2023 Letter INSPECTION SUMMARY
01/26/2024 Letter INSPECTION SUMMARY
01/26/2024 Certificate/License Codes Temporary Certificate of Occupancy
01/26/2024 Receipt Receipt for transaction:2024-000422
02/22/2024 Plot Plan APPROVED AS BUILT PLOT PLAN
02/23/2024 Letter INSPECTION SUMMARY
02/27/2024 2215 SW Hook Farm Dr TCO Extension
02/27/2024 Certificate/License Codes Temporary Certificate of Occupancy
02/27/2024 Receipt Receipt for transaction:2024-001146
03/18/2024 Letter INSPECTION SUMMARY
03/18/2024 Letter INSPECTION SUMMARY
03/25/2024 Letter Field Certificate of Occupancy
03/25/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide: