Permit Application Status

PRRES20231517


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20231517
Building Permit - Residential
Certificate of Occupancy
WALKER CUSTOM HOMES LLC
NEW SINGLE FAMILY
NEW HOUSE. FINISHED/UNFINISHED BASEMENT. COVERED DECK. ROOF TRUSSES. ENGINEERED FLOOR SYSTEM - DEFERRED. SIDEWALK ON MAIN IS NOT BEING INSTALLED - PAYMENT IN LIEU OF BEING MADE. PLOT PLAN SHOWS SIDEWALK BUT IS NOT TO BE INSTALLED. SIDEWALK FROM HOUSE TO STREET REQUIRED PER PLANNING NOTE ATTACHED. STOP WORK ORDER generated on 04/20/2023 12:00 AM by username 'Steve Robbins'. STOP WORK ORDER removed on 05/04/2023 12:00 AM by username 'Mark Harding'. STOP WORK ORDER generated on 10/09/2023 12:00 AM by username 'Robb Popp'. STOP WORK ORDER removed on 10/10/2023 12:00 AM by username 'Robb Popp'.
04/10/2023
04/24/2023
10/16/2023
01/03/2024
Locations
Contacts
WALKER CUSTOM HOMES, LLC, Address:PO BOX 3194, Phone:(913) 208-2026  
WALKER CUSTOM HOMES LLC, Address:PO BOX 3194  
Jason walker, Address:PO Box 247, Phone:(913) 208-2026  
5 STAR HEATING & COOLING, Address:211 NW 12TH, Phone:(816) 517-3341  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
WALKERCUSTOMHOMESKC@GMAIL.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331401-Water Tap Fee $3,730.00 $3,730.00 Paid 04/24/2023
8350015-Water Meter Fee $550.50 $550.50 Paid 04/24/2023
8331507-Sanitary Sewer Development Fee $1,384.00 $1,384.00 Paid 04/24/2023
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 04/24/2023
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 04/24/2023
9110078-Valuation Fee New Single Family $1,357.39 $1,357.39 Paid 04/24/2023
9110078-Investigation Fee $1,357.39 $1,357.39 Paid 04/24/2023
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 08/07/2023
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 08/07/2023
9110080-3rd and Subsequent Inspection Fee (Per Hour) $75.00 $75.00 Paid 12/27/2023
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 12/27/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Failed - Stop Work 4/20/2023 04/20/2023
Misc
Corrective Action Required
04/20/2023
We do not have a plot plan that has been approved. No more work until it has been approved and erosion control is installed.
Underslab Plumbing Inspection - Residential Failed - Stop Work 5/4/2023 5/4/2023 05/04/2023
Misc
Corrective Action Required
05/04/2023
Contact Mark Harding to remove stop construction on permit. do not proceed.
Footing Inspection - Residential Passed 5/4/2023 05/04/2023
Underslab Plumbing Inspection - Residential Passed 5/4/2023 05/04/2023
Misc
Informational
05/04/2023
erosion control is in place
Sewer Service Inspection - R Passed 05/08/2023
Water Service Inspection - R Partial 5/8/2023 (10:45) 5/8/2023 05/08/2023
Misc
Informational
05/08/2023
Pex ran roughly 15’ from foundation
Water Service Inspection - R Passed 5/9/2023 05/09/2023
Misc
Resolved
05/09/2023
Pex ran roughly 15’ from foundation
Miscellaneous Inspection Failed 5/22/2023 5/22/2023 05/22/2023
Misc
Corrective Action Required
05/22/2023
5/22/23 -An anonymous online complaint was received on 5/19/23 stating that trash from another site was being dumped in the front stoop as fill material. This email as well as a picture was uploaded to the portal -A second complaint was made on 5/22/23 and a second photo is uploaded to the portal **Remove all unapproved fill material from site
Driveway Inspection Partial 6/20/2023 6/20/2023 06/20/2023
Misc
Informational
06/20/2023
6-20-23 DP. Crew had Driveway formed, aggregate compacted. Asphalt was broke up bad at beginning of DW. Had them removed the surface asphalt and have a clean transition with concrete. Approved to pour.
Electrical Service Inspection Failed 7/12/2023 7/12/2023 07/12/2023
Misc
Corrective Action Required
07/12/2023
Must obtain seperate permit for temporary power
Erosion Control Inspection Residential Failed 8/2/2023 8/2/2023 08/02/2023
Misc
Corrective Action Required
04/20/2023
Maintain overgrown vegetation
All Rough Inspection - Residential Not Ready 8/3/2023 8/3/2023 08/03/2023
Misc
Corrective Action Required
08/03/2023
Inspection denied -no city stamped plans on site
Erosion Control Inspection Residential Partial 08/03/2023
Misc
Resolved
08/03/2023
Maintain overgrown vegetation
Misc
Informational
08/03/2023
Erosion control in compliance
All Rough Inspection - Residential Not Ready 8/4/2023 8/4/2023 08/04/2023
Misc
Resolved
08/04/2023
Inspection denied -no city stamped plans on site
Misc
Corrective Action Required
08/04/2023
No inspection performed -uncover covered front porch -revise and submit basement plans to show as built -provide I-joist and truss packets on site for inspection
Erosion Control Inspection Residential Partial 08/04/2023
Misc
Informational
08/03/2023
Erosion control in compliance
All Rough Inspection - Residential Failed 8/23/2023 8/23/2023 08/23/2023
Misc
Corrective Action Required
08/04/2023
No inspection performed -uncover covered front porch -revise and submit basement plans to show as built -provide I-joist and truss packets on site for inspection
Misc
Corrective Action Required
08/23/2023
NOT A COMPLETE LIST -Missing fire blocking at top plate north wall master bedroom -strap 2 in DWV PROVIDE TRUSS PLANS AND I JOIST PLANS RESUBMIT PLANS TO SHOW AS BUILT
All Rough Inspection - Residential Not Ready 8/25/2023 8/25/2023 08/25/2023
Misc
Partial Correction
08/25/2023
No complete inspection performed -revise and submit basement plans to show as built -provide I-joist and truss packets on site for inspection
Misc
Partial Correction
08/25/2023
NOT A COMPLETE LIST -Missing fire blocking at top plate north wall master bedroom PROVIDE (COMPLETE) TRUSS PLANS AND I JOIST PLANS RESUBMIT PLANS TO SHOW AS BUILT
All Rough Inspection - Residential Failed 8/28/2023 8/28/2023 08/28/2023
Misc
Partial Correction
08/25/2023
-Maintain overgrown vegetation -Seal all plate penetrations at garage -Anchor bolts to be in middle third of plate at garage -Tighten anchor bolts at garage -Truss hold down screws to be through both plates at SE garage truss -Install soffit vents for attic cross ventilation at garage -Provide (2) rows 16d sinkers 3” oc at top plate to header connection on garage portal framing -Truss screws to be through both top plates: at front window -Structural straps at over bored top plates of load bearing walls to be Min 16g and extend min 6” beyond bore each direction -Midpoint straps at 2” dwv must prevent lateral movement perpendicular to the axis of the pipe -Protect all nm in attic space within 6’ of attic access -Seal top plate penetration at owner’s suite near window -T brace or I brace gable ends for lateral bracing -Tighten anchor bolts throughout basement -Secure midpoint of all 2” dwv in basement -Provide Bocca plate at dwv in basement bath -Connect trap for owner’s suit tub-visible from basement bed 3 -Fireblock gap in ceiling line fireblocking at dwv by basement window -Provide Bocca plate at sole plate basement bed -Provide soffit vents for attic space cross ventilation
Misc
Resolved
08/28/2023
All Rough Inspection - Residential Failed 08/28/2023
Misc
Partial Correction
08/28/2023
-Maintain overgrown vegetation -Seal all plate penetrations at garage -Anchor bolts to be in middle third of plate at garage -Tighten anchor bolts at garage -Truss hold down screws to be through both plates at SE garage truss -Install soffit vents for attic cross ventilation at garage -Provide (2) rows 16d sinkers 3” oc at top plate to header connection on garage portal framing -Truss screws to be through both top plates: at front window -Structural straps at over bored top plates of load bearing walls to be Min 16g and extend min 6” beyond bore each direction -Midpoint straps at 2” dwv must prevent lateral movement perpendicular to the axis of the pipe -Protect all nm in attic space within 6’ of attic access -Seal top plate penetration at owner’s suite near window -T brace or I brace gable ends for lateral bracing -Tighten anchor bolts throughout basement -Secure midpoint of all 2” dwv in basement -Provide Bocca plate at dwv in basement bath -Connect trap for owner’s suit tub-visible from basement bed 3 -Fireblock gap in ceiling line fireblocking at dwv by basement window -Provide Bocca plate at sole plate basement bed -Provide soffit vents for attic space cross ventilation -Install power to garage -Expose unerground conduit for inspection -Provide min 10 psi at gas gauge
Electrical Service Inspection Passed 08/28/2023
Misc
Resolved
08/28/2023
Must obtain seperate permit for temporary power
Gas Service Inspection - Residential Failed 08/28/2023
G2417.4.1 Test Pressure
Corrective Action Required
08/28/2023
INSPECTION, TESTING AND PURGING. AMENDED 7-945. The test pressure to be used shall be not less than one and one-half times the proposed maximum working pressure, but not less than 10 psig (68.9kPa) irrespective of design pressure. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure, the test pressure shall not be less than 60 psig. Where the test pressure exceeds 125 psig (862 kPa gauge), the test pressure shall not exceed a value that produces a hoop stress in the piping greater than 50 percent of the specified minimum yield strength of the pipe.
All Rough Inspection - Residential Failed 9/7/2023 9/7/2023 09/07/2023
Misc
Partial Correction
08/28/2023
-Structural straps at over bored top plates of load bearing walls to be Min 16g and extend min 6” beyond bore each direction -T brace or I brace gable ends for lateral bracing -Tighten anchor bolts throughout basement -Fireblock gap in ceiling line fireblocking at dwv by basement window -Provide soffit vents for attic space cross ventilation (nothing provided at front of house)
All Rough Inspection - Residential Failed 9/12/2023 9/12/2023 09/12/2023
Misc
Partial Correction
09/07/2023
-Structural straps at over bored top plates of load bearing walls to be Min 16g and extend min 6” beyond bore each direction
All Rough Inspection - Residential Passed 09/13/2023
Misc
Resolved
09/13/2023
-Structural straps at over bored top plates of load bearing walls to be Min 16g and extend min 6” beyond bore each direction
Erosion Control Inspection Residential Failed 10/3/2023 10/3/2023 10/03/2023
Misc
Resolved
10/03/2023
Erosion control in compliance
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
10/03/2023
10/3/23 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Failed - Stop Work 10/9/2023 10/9/2023 10/09/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
10/03/2023
10/3/23 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 10/9/23 EROSION CONTROL STILL NOT IN COMPLIANCE-PROVIDE EROSION CONTROL METHODS AT PERIMETER IMMEDIATELY. STOP WORK ISSUED
Erosion Control Inspection Residential Partial 10/10/2023 10/10/2023 10/10/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
10/09/2023
10/10/23 Erosion control in compliance at time of inspection
Gas Service Inspection - Residential Passed 10/10/2023 10/10/2023 10/10/2023
G2417.4.1 Test Pressure
Resolved
10/10/2023
INSPECTION, TESTING AND PURGING. AMENDED 7-945. The test pressure to be used shall be not less than one and one-half times the proposed maximum working pressure, but not less than 10 psig (68.9kPa) irrespective of design pressure. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure, the test pressure shall not be less than 60 psig. Where the test pressure exceeds 125 psig (862 kPa gauge), the test pressure shall not exceed a value that produces a hoop stress in the piping greater than 50 percent of the specified minimum yield strength of the pipe.
Occupancy Inspection - Codes Residential Failed 12/20/2023 12/20/2023 12/20/2023
Misc
Corrective Action Required
12/20/2023
-As graded plot plan is required PRIOR to sod -Pay all fees due before occupancy -Provide code compliant gaurdrail at front porch over 30" to grade- R312.1.1 through R312.1.3 -Provide lockout on hardwired oven breaker -Install security screws at hinges and strike plates per LS CH 7 -Install sealed type light fixture at front door below 8' per LS CH 7 -Provide fire protection of exposed I joists per R302.13 -Provide thermal barrier for exposed foam per R316.4 -Provide 100 watt flood light at rear exterior per LS CH 7
Occupancy Inspection - Codes Residential Failed 12/28/2023 12/28/2023 12/28/2023
Misc
Corrective Action Required
12/20/2023
-As graded plot plan is required PRIOR to sod -Install security screws at hinges and strike plates per LS CH 7- Please see code sections below -Provide fire protection of exposed I joists per R302.13-Seal all gaps and penetrations -Provide thermal barrier for exposed foam per R316.4-Provide documentation for product used. Must comply with IRC 316.4 and NFPA 275 Temperature Transmission Fire Test and the Integrity FIre Test
Misc
Corrective Action Required
12/28/2023
**Sec. 7-1408.1. - Hinges. Hinges for exterior swinging doors shall comply with the following: A. At least two (2) wood screws, three (3) inches in length, penetrating at least one inch into wall structure shall be used. Solid wood fillers or shims shall be used to eliminate any space between the wall structure and door frame behind each hinge. **Sec. 7-1408.2. - Strike plates. Exterior door strike plates shall be a minimum of eighteen (18) gauge metal with four (4) offset screw holes. Strike plates shall be attached to wood with not less than three (3) inch wood screws, which shall have a minimum of one inch penetration into the nearest stud.
Miscellaneous Inspection Passed 12/28/2023
Misc
Resolved
12/28/2023
5/22/23 -An anonymous online complaint was received on 5/19/23 stating that trash from another site was being dumped in the front stoop as fill material. This email as well as a picture was uploaded to the portal -A second complaint was made on 5/22/23 and a second photo is uploaded to the portal **Remove all unapproved fill material from site
Occupancy Inspection - Codes Residential Ready for Temp CO 12/28/2023 12/28/2023 12/28/2023
Misc
Corrective Action Required
12/28/2023
-As graded plot plan is required PRIOR to sod -Driveway inspection pending
Misc
Resolved
12/28/2023
**Sec. 7-1408.1. - Hinges. Hinges for exterior swinging doors shall comply with the following: A. At least two (2) wood screws, three (3) inches in length, penetrating at least one inch into wall structure shall be used. Solid wood fillers or shims shall be used to eliminate any space between the wall structure and door frame behind each hinge. **Sec. 7-1408.2. - Strike plates. Exterior door strike plates shall be a minimum of eighteen (18) gauge metal with four (4) offset screw holes. Strike plates shall be attached to wood with not less than three (3) inch wood screws, which shall have a minimum of one inch penetration into the nearest stud.
Driveway Inspection Passed 12/29/2023 12/29/2023 12/29/2023
Misc
Informational
06/20/2023
6-20-23 DP. Crew had Driveway formed, aggregate compacted. Asphalt was broke up bad at beginning of DW. Had them removed the surface asphalt and have a clean transition with concrete. Approved to pour. 12-29-23 Dustin A, DW is poured and is in compliance with city specs. Passed
Plot Plan Inspection Passed 1/2/2024 01/02/2024
Occupancy Inspection - Codes Residential Full C of O 1/3/2024 1/3/2024 01/03/2024
Misc
Resolved
01/03/2024
-As graded plot plan is required PRIOR to sod -Driveway inspection pending
Erosion Control Inspection Residential Passed 01/03/2024
DCM3 ESC REQUIRED 2 DAY
Resolved
01/03/2024
10/10/23 Erosion control in compliance at time of inspection
Documents & Images
Date Uploaded File Type Document Name
04/10/2023 500 NW Main st Permit CIty docs signed
04/13/2023 Permit Codes Residential Plan Review
04/13/2023 Permit Codes Residential Plan Review
04/19/2023 Approved Plans APPROVED TRUSS PACKAGE
04/19/2023 Permit Codes Residential Plan Review
04/20/2023 Conditons for approval 500 NW Main
04/20/2023 Letter Stop Work Order
04/24/2023 Email Sidewalk Memo Style
04/24/2023 Plot Plan APPROVED PLOT PLAN
04/24/2023 Approved Plans APPROVED TRUSS LAYOUT
04/24/2023 Approved Plans APPROVED PLANS
04/24/2023 Permit Codes Residential Plan Review
04/24/2023 Permit DS Building Permit
04/24/2023 Receipt Receipt for transaction:2023-002338
04/25/2023 Wilmoth 500 NW Main St LSMO Lot 6 Main Orchard 3rd Party Subgrade and Footing Inspection Report 4-25-23
05/04/2023 Letter Stop Work Order
05/04/2023 Letter INSPECTION SUMMARY
05/04/2023 Letter INSPECTION SUMMARY
05/08/2023 Letter INSPECTION SUMMARY
05/08/2023 Letter INSPECTION SUMMARY
05/09/2023 Letter INSPECTION SUMMARY
05/22/2023 Anonymous online complaint - 500 NW Main St#20231517
05/22/2023 Trash dumped in front stoop
05/22/2023 Second photo of trash in stoop
05/22/2023 Letter INSPECTION SUMMARY
06/20/2023 Letter INSPECTION SUMMARY
07/12/2023 Letter INSPECTION SUMMARY
08/02/2023 Letter INSPECTION SUMMARY
08/03/2023 Letter INSPECTION SUMMARY
08/03/2023 Letter INSPECTION SUMMARY
08/04/2023 Letter INSPECTION SUMMARY
08/04/2023 Letter INSPECTION SUMMARY
08/07/2023 APPROVED TRUSS LAYOUT 500 NW Main
08/07/2023 Receipt Receipt for transaction:2023-006085
08/16/2023 Approved Plans APPROVED JOIST DRAWING
08/23/2023 Letter INSPECTION SUMMARY
08/25/2023 Letter INSPECTION SUMMARY
08/25/2023 Approved Plans APPROVED TRUSS PACKAGE
08/28/2023 APPROVED PLANS
08/28/2023 Letter INSPECTION SUMMARY
08/28/2023 Letter INSPECTION SUMMARY
08/28/2023 Letter INSPECTION SUMMARY
08/28/2023 Letter INSPECTION SUMMARY
08/28/2023 Letter INSPECTION SUMMARY
09/07/2023 Letter INSPECTION SUMMARY
09/12/2023 Letter INSPECTION SUMMARY
09/13/2023 Letter INSPECTION SUMMARY
10/03/2023 Letter INSPECTION SUMMARY
10/09/2023 Letter Stop Work Order
10/10/2023 Letter INSPECTION SUMMARY
10/10/2023 Letter INSPECTION SUMMARY
12/20/2023 Letter INSPECTION SUMMARY
12/27/2023 Receipt Receipt for transaction:2023-009302
12/28/2023 Letter INSPECTION SUMMARY
12/28/2023 Vapor Barrier Report
12/28/2023 Letter INSPECTION SUMMARY
12/29/2023 Letter INSPECTION SUMMARY
12/29/2023 Plot Plan APPROVED AS BUILT PLOT PLAN
01/02/2024 Letter INSPECTION SUMMARY
01/03/2024 Letter Codes Final Certificate of Occupancy
01/03/2024 Letter Field Certificate of Occupancy
01/03/2024 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home