Permit Application Status

PRRES20230465


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20230465
Building Permit - Residential
Final Completion
CONSTABLE VIVIAN L TRUSTEE OF CONSTABLE VIVIAN L TRUST DATED 3/04/21
NEW OTHER (RESIDENTIAL)
NEW 60'x120' STORAGE BUILDING. *ADDING BATHROOM INSIDE BUILDING 2 200 AMP SERVICES TO BUILDING
02/02/2023
03/16/2023
05/16/2024
Locations
Contacts
aden.monheiser@gmail.com  
CONSTABLE VIVIAN L TRUSTEE OF CONSTABLE VIVIAN L TRUST DATED 3/04/21, Address:12809 RANSON RD  
Southwind MVP, Address:9851 Widmer Rd, Phone:(913) 322-0868  
Encore Inc., Address:2580 SE Ranson Rd  
PRO CIRCUIT, Address:4925 DERAMUS AVE , Phone:(816) 474-9292  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 03/09/2023 03/09/2023
Andrea Sessler
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New Other $540.00 $540.00 Paid 03/16/2023
8350015-Water Meter Fee $322.81 $322.81 Paid 09/13/2023
$680.46
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Rough Plumbing Inspection - Residential Failed 5/9/2023 05/09/2023
Misc
Corrective Action Required
05/09/2023
-No address posted
Rough Plumbing Inspection - Residential Passed 5/15/2023 05/15/2023
Misc
Resolved
05/15/2023
Electrical Service Inspection Failed 4/16/2024 04/16/2024
Misc
Corrective Action Required
04/16/2024
-Existing work does not match the approved electrical plans.
Electrical Service Inspection Failed 5/9/2024 5/9/2024 05/09/2024
Misc
Resolved
05/09/2024
Misc
Corrective Action Required
05/09/2024
-Can’t have aluminum conductor encased in concrete install # 2 copper -Grind off paint between grounding lug and building steel -Install bonding bushings to bond metal raceway and gutter enclosing the service conductor
Misc
Informational
05/09/2024
Service conductors buried to pole. Appears to be waiting for transformer.
All Rough Inspection - Residential Passed 05/16/2024
Electrical Service Inspection Passed 5/16/2024 5/16/2024 05/16/2024
Misc
Resolved
05/16/2024
Misc
Informational
05/09/2024
Service conductors buried to pole. Appears to be waiting for transformer.
Final Inspection - Residential Passed 05/16/2024
Footing Inspection - Residential Passed 05/16/2024
Documents & Images
Date Uploaded File Type Document Name
02/02/2023 Plot Plan APPROVED PLOT PLAN
02/02/2023 Plans P22221 - Aden Monheiser Foundation Calculations - Sealed and Signed (1)
02/02/2023 Plans T22O8017A SPL FINAL (2)
03/09/2023 Scope of Work SCOPE OF WORK
03/09/2023 Approved Plans APPROVED FOUNDATON PLAN
03/09/2023 Approved Plans APPROVED PLANS
03/16/2023 Permit DS Building Permit
03/16/2023 Receipt Receipt for transaction:2023-001484
05/09/2023 Letter INSPECTION SUMMARY
05/09/2023 Plans Monheiser Barn - P100_Signed
05/15/2023 Letter INSPECTION SUMMARY
05/15/2023 Letter INSPECTION SUMMARY
09/13/2023 Receipt Receipt for transaction:2023-007003
10/03/2023 Approved Plans APPROVED ELECTRICAL PLANS
01/31/2024 Letter Codes 140 Day Letter
03/11/2024 Letter Codes 180 Day Letter
03/20/2024 LS Extension Request Form
04/16/2024 Letter INSPECTION SUMMARY
04/16/2024 Letter DS Building Permit
04/30/2024 20240429 - ELEC E100 (Service Revisions)_Signed
04/30/2024 Plans updated electrical plan
05/09/2024 Letter INSPECTION SUMMARY
05/10/2024 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home