Permit Application Status

PRRES20226253


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20226253
Building Permit - Residential
Certificate of Occupancy
DRIPPE HOMES INC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASMENT - COVERED DECK - ENG FLOOR AND ROOF SYSTEMS ( DEF. PLANS ) STOP WORK ORDER generated on 03/29/2023 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 03/30/2023 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER generated on 08/23/2023 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 08/24/2023 12:00 AM by username 'Mitchell Schwarz'.
12/27/2022
01/25/2023
07/18/2023
10/18/2023
Locations
Contacts
Drippe Homes PC, Address:919 E Jesuit Lane  
DRIPPE HOMES INC, Address:919 E JESUIT LN  
Drippe Homes, INC, Address:919 E Jesuit Ln  
Drippe Homes PC, Address:919 E Jesuit Lane  
PRAIRIE CENTER PLUMBING HEATING & A/C, Address:242 N MARION, Phone:(913) 829-6263  
PRAIRIE CENTER PLUMBING HEATING & A/C, Address:242 N MARION, Phone:(913) 829-6263  
PRIDE SERVICES INC, Address:3842 GEORGIA TERR, Phone:(785) 242-9700  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sanitary Sewer Development Fee $1,384.00 $1,384.00 Paid 01/25/2023
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 01/25/2023
7232302-Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 01/25/2023
8331401-Water Tap Fee $3,730.00 $3,730.00 Paid 01/25/2023
8350015-Water Meter Fee $550.50 $550.50 Paid 01/25/2023
9110078-Valuation Fee New Single Family $1,679.29 $1,679.29 Paid 01/25/2023
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 10/17/2023
9110080-3rd and Subsequent Inspection Fee (Per Hour) $75.00 $75.00 Paid 10/17/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sewer Service Inspection - R Partial 3/15/2023 3/15/2023 03/15/2023
Misc
Informational
03/15/2023
Inspected roughly 30 feet from sewer stub
Sewer Service Inspection - R Passed 3/17/2023 (11:30) 3/17/2023 03/17/2023
Misc
Resolved
03/17/2023
Inspected roughly 30 feet from sewer stub
Water Service Inspection - R Passed 3/20/2023 (9:15) 3/20/2023 03/20/2023
Underslab Plumbing Inspection - Residential Failed 3/29/2023 3/29/2023 03/29/2023
Misc
Corrective Action Required
03/29/2023
inspection denied no address, erosion control not in compliance, footing poured without inspection.
Footing Inspection - Residential Failed - Stop Work 3/29/2023 03/29/2023
Misc
Corrective Action Required
03/29/2023
stop work issued footing poured without inspection
Footing Inspection - Residential Passed 3/30/2023 03/30/2023
Misc
Resolved
03/30/2023
stop work issued footing poured without inspection
Misc
Informational
03/30/2023
third party inspection report uploaded.
Underslab Plumbing Inspection - Residential Failed 3/31/2023 3/31/2023 03/31/2023
Misc
Corrective Action Required
03/29/2023
inspection denied no address posted.
Underslab Plumbing Inspection - Residential Failed 4/4/2023 4/4/2023 04/04/2023
Misc
Corrective Action Required
03/31/2023
One six foot section of drain pipe is not supported by gravel
Underslab Plumbing Inspection - Residential Passed 4/6/2023 4/6/2023 04/06/2023
Misc
Resolved
04/06/2023
One six foot section of drain pipe is not supported by gravel
Gas Service Inspection - Residential Failed 6/8/2023 6/8/2023 06/08/2023
Misc
Corrective Action Required
06/08/2023
-Provide shut off within 12” of disconnect at fireplace -repair/replace damaged csst above basement bedroom
Gas Service Inspection - Residential Not Ready 6/15/2023 6/15/2023 06/15/2023
Misc
Corrective Action Required
06/08/2023
NO ACCESS FOR INSPECTION CALLED NUMBER ON INSPECTION -Provide shut off within 12” of disconnect at fireplace -repair/replace damaged csst above basement bedroom
All Rough Inspection - Residential Failed 6/21/2023 6/21/2023 06/21/2023
Misc
Corrective Action Required
06/21/2023
No further inspections until erosion control in compliance -panel splices for garage portal frame to be in the middle 24” of portal leg -protect se cable in attic -solid block panel splices in garage -midway strap all dwv 2” in diameter or less in stud bays -provide proper slope for dwv above master bath -nail all exterior wall corners to code -secure gas line at fireplace -fire block fireplace to ceiling space -strap top plate left of slider where less than 24” between splices -provide missing truss hangers above bed 2 and bed2 bath -address over notched exterior wall studs in basement -fire block vertically to horizontally every 10’ see rec room N wall -fire block wall space at stairwell to furr down in rec room -seal top plate penetration in bed 3 W wall -seal wall space to ceiling space bed 4 closet -fire block into furr down left of bed 4 entry -provide proper bonding lug at ufer ground rod -upload engineer letter for I-joist and truss repairs -de rate SE cable in attic
Electrical Service Inspection Failed 6/21/2023 06/21/2023
Misc
Corrective Action Required
06/21/2023
-Provide approved connector at ufer ground rod connection -de-rate SE cable in attic
Gas Service Inspection - Residential Passed 6/21/2023 06/21/2023
Misc
Resolved
06/21/2023
NO ACCESS FOR INSPECTION CALLED NUMBER ON INSPECTION -Provide shut off within 12” of disconnect at fireplace -repair/replace damaged csst above basement bedroom
Misc
Informational
06/21/2023
Pressure okay
Erosion Control Inspection Residential Failed 6/21/2023 06/21/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
06/21/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/21/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
All Rough Inspection - Residential Failed 6/28/2023 6/28/2023 06/28/2023
Misc
Corrective Action Required
06/21/2023
No further inspections until erosion control in compliance -nail all exterior wall corners to code -secure gas line at fireplace -provide missing truss hangers above bed 2 and bed2 bath -address over notched exterior wall studs in bas -seal wall space to ceiling space bed 4 closet -fire block into furr down left of bed 4 entry -provide proper bonding lug at ufer ground rod -upload engineer letter for I-joist and truss repairs
All Rough Inspection - Residential Passed 7/3/2023 7/3/2023 07/03/2023
Misc
Resolved
07/03/2023
Electrical Service Inspection Passed 7/6/2023 7/6/2023 07/06/2023
Misc
Resolved
07/06/2023
-Provide approved connector at ufer ground rod connection -de-rate SE cable in attic
Driveway Inspection Passed 7/25/2023 7/25/2023 07/28/2023
Misc
Informational
07/25/2023
7-25-23 BR Driveway is framed and ready for concrete. 7-28-23 BR Driveway is constructed to LS specification.
Erosion Control Inspection Residential Failed 8/18/2023 08/18/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
06/21/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/21/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/18/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Maintain overgrown vegetation
Erosion Control Inspection Residential Failed - Stop Work 8/23/2023 8/23/2023 08/23/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
08/18/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/18/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/18/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Maintain overgrown vegetation
MISC
Corrective Action Required
08/23/2023
Erosion control still not in compliance Stop work issued. -maintain silt fence -maintain overgrown vegetation Mitchell Schwarz 08/23/2023 10:47 AM
Erosion Control Inspection Residential Partial 8/24/2023 8/24/2023 08/24/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
08/24/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM3 ESC REQUIRED 2 DAY
Resolved
08/24/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM3 ESC REQUIRED 2 DAY
Resolved
08/24/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Maintain overgrown vegetation
MISC
Resolved
08/24/2023
Erosion control still not in compliance Stop work issued. -maintain silt fence -maintain overgrown vegetation Mitchell Schwarz 08/23/2023 10:47 AM
Misc
Corrective Action Required
08/24/2023
Erosion control back in compliance 8/24/23
Driveway Inspection Passed 9/26/2023 (9:00) 9/26/2023 09/26/2023
Misc
Informational
07/25/2023
7-25-23 BR Driveway is framed and ready for concrete. 9-26-23 A.A, DW poured. Frames are pulled. Passed
Sidewalk Inspection Partial 9/26/2023 (9:00) 9/26/2023 09/26/2023
Misc
Informational
09/26/2023
9-26-23 A.A, SW in rear of house is framed . Aggregate is compacted and slopes are in compliance. Approved to pour . Conditions can change
Sidewalk Inspection Passed 10/3/2023 10/3/2023 10/02/2023
Misc
Informational
09/26/2023
9-26-23 A.A, SW in rear of house is framed . Aggregate is compacted and slopes are in compliance. Approved to pour . Conditions can change 10-2-23 Dustin A, SW is poured. Slopes are in compliance. Forms are pulled. Passed
Plot Plan Inspection Passed 10/6/2023 10/06/2023
Occupancy Inspection - Codes Residential Failed 10/6/2023 10/6/2023 10/06/2023
Misc
Corrective Action Required
10/06/2023
-remove trash enclosure from public roadway. -address pending deck pier inspection -sod -splash blocks and sump pump discharge to extend 36” out from foundation -all non GFCI outlets in unfinished areas to be labeled -garage door to be self closing and latching -remove dust covers from smokes for testing/inspection -secondary locking device at rear sliders -spark ring for kitchen and wet bar backsplash outlets -install bath fan at front entry bath -open junction box under stairs in basement -provide fire protection for all engineered Ijoist in unfinished area -provide breaker lock out for all hardwired appliances not in direct sight of panel -provide afci protection for all circuits in kitchen. See breaker #17 -secure conduit at water heaters -(2) 1/2” through bolts at each deck post to beam connection -deck stair landing to extend 36” from foundation -provide handrail at deck stairs -replace accessible light fixtures at rear of home with non accessible light fixtures -
Occupancy Inspection - Codes Residential Failed 10/6/2023 10/6/2023 10/06/2023
Misc
Corrective Action Required
10/06/2023
-remove trash enclosure from public roadway. -address pending deck pier inspection -pay all fees -obtain lawn irrigation permit -sod -splash blocks and sump pump discharge to extend 36” out from foundation -all non GFCI outlets in unfinished areas to be labeled -garage door to be self closing and latching -remove dust covers from smokes for testing/inspection -secondary locking device at rear sliders -spark ring for kitchen and wet bar backsplash outlets -install bath fan at front entry bath -open junction box under stairs in basement -provide fire protection for all engineered Ijoist in unfinished area -provide breaker lock out for all hardwired appliances not in direct sight of panel -provide afci protection for all circuits in kitchen. See breaker #17 -secure conduit at water heaters -(2) 1/2” through bolts at each deck post to beam connection -deck stair landing to extend 36” from foundation -provide handrail at deck stairs -replace accessible light fixtures at rear of home with non accessible light fixtures -guard rail at front stoop where more than 30” from grade 36” out.
Piers/Caissons Inspection - Residential Passed 10/17/2023 10/17/2023
Misc
Informational
10/17/2023
third party inspection performed.
Erosion Control Inspection Residential Passed 10/17/2023
Misc
Resolved
10/17/2023
Erosion control back in compliance 8/24/23
Occupancy Inspection - Codes Residential Failed 10/13/2023 10/17/2023 10/17/2023
Misc
Corrective Action Required
10/06/2023
-pay all fees -obtain lawn irrigation permit
Occupancy Inspection - Codes Residential Full C of O 10/18/2023
Misc
Resolved
10/18/2023
-pay all fees -obtain lawn irrigation permit
Documents & Images
Date Uploaded File Type Document Name
12/28/2022 License_Tax_Application
12/29/2022 Permit Codes Residential Plan Review
01/16/2023 Waver Approved - LOT 105 - PRELIM PLOT PLAN
01/17/2023 3223 SW Enoch St_16 JAN 2023 with Seal
01/18/2023 Permit Codes Residential Plan Review
01/19/2023 Application Form Residental Permit Application_1- signed
01/19/2023 Drippe Homes, Inc Mail - Fwd_ FW_ Help needed with setback requirement
01/19/2023 Plot Plan approved plot plan
01/19/2023 Permit Codes Residential Plan Review
01/24/2023 Approved Plans APPROVED PLANS
01/24/2023 Permit Codes Residential Plan Review
01/25/2023 FPS22-1062_St Marys Lumber_Rudman-LAYOUT revised 2018IBC with Shop Drawing Stamp
01/25/2023 35717T - Drippe - Rudman - Final Roof Truss Layout 01-23-23 with Shop Dwg Stamp
01/25/2023 Permit DS Building Permit
01/25/2023 Receipt Receipt for transaction:2023-000478
01/25/2023 Approved Plans approved joist layout
01/25/2023 Approved Plans APPROVED TRUSS LAYOUT
03/15/2023 Letter INSPECTION SUMMARY
03/17/2023 Letter INSPECTION SUMMARY
03/20/2023 Letter INSPECTION SUMMARY
03/29/2023 Letter INSPECTION SUMMARY
03/29/2023 Letter Stop Work Order
03/30/2023 3223 SW Enoch St_FTG INSP_2023-03-02
03/30/2023 Letter INSPECTION SUMMARY
03/31/2023 Letter INSPECTION SUMMARY
04/04/2023 Letter INSPECTION SUMMARY
04/06/2023 Letter INSPECTION SUMMARY
06/08/2023 Letter INSPECTION SUMMARY
06/15/2023 Letter INSPECTION SUMMARY
06/21/2023 Letter INSPECTION SUMMARY
06/21/2023 Letter INSPECTION SUMMARY
06/21/2023 Letter INSPECTION SUMMARY
06/21/2023 Letter INSPECTION SUMMARY
06/28/2023 Letter INSPECTION SUMMARY
06/28/2023 ParagonJob_43452_Drippe-Rudman35717T
06/28/2023 ParagonJob_43492_Drippe-Rudman35717T
07/02/2023 scan_20230628210023
07/03/2023 Letter INSPECTION SUMMARY
07/06/2023 Letter INSPECTION SUMMARY
07/25/2023 Letter INSPECTION SUMMARY
07/28/2023 Letter INSPECTION SUMMARY
08/18/2023 Letter INSPECTION SUMMARY
08/18/2023 Letter INSPECTION SUMMARY
08/23/2023 Letter Stop Work Order
08/24/2023 Letter INSPECTION SUMMARY
09/26/2023 Letter INSPECTION SUMMARY
09/26/2023 Letter INSPECTION SUMMARY
10/02/2023 Letter INSPECTION SUMMARY
10/06/2023 Letter INSPECTION SUMMARY
10/06/2023 Letter INSPECTION SUMMARY
10/06/2023 Letter INSPECTION SUMMARY
10/17/2023 3223 SW Enoch St_DECK PIER INSP_2023-07-27
10/17/2023 Letter INSPECTION SUMMARY
10/17/2023 Letter INSPECTION SUMMARY
10/17/2023 Letter INSPECTION SUMMARY
10/17/2023 Receipt Receipt for transaction:2023-007836
10/18/2023 Letter Field Certificate of Occupancy
10/18/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home