Summary
PRRES20225890
Building Permit - Residential
Certificate of Occupancy
NEW DUPLEX
NEW DUPLEX - UNFINISHED BASEMENT - UNCOVERED DECK. 2111 FINISHED BASEMENT.
11/28/2022
12/05/2022
05/28/2023
09/11/2023
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
JASONH@CLOVERANDHIVE.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for New Duplex $2,204.53 $2,204.53 Paid 12/05/2022
Right of Way Permit Fee $85.00 $85.00 Paid 12/05/2022
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 12/05/2022
Water Tap Fee $7,460.00 $7,460.00 Paid 12/05/2022
Water Meter Fee $1,101.00 $1,101.00 Paid 12/05/2022
Sanitary Sewer Development Fee $2,768.00 $2,768.00 Paid 12/05/2022
Valuation Fee for New Duplex $74.34 $74.34 Paid 05/05/2023
$2,278.87
Temporary Occupancy Fee $50.00 $50.00 Paid 08/22/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 1/18/2023 01/18/2023
Underslab Plumbing Inspection - Residential Failed 1/18/2023 1/18/2023 01/18/2023
Misc
Corrective Action Required
01/18/2023
backfill around foundation for viewing to inspect.
Underslab Plumbing Inspection - Residential Passed 1/24/2023 1/24/2023 01/24/2023
Misc
Corrective Action Required
01/18/2023
- 2109 OK - 2111 OK
Sewer Service Inspection - R Partial 1/24/2023 01/24/2023
Misc
Corrective Action Required
01/24/2023
- 2109 -2111 OK TO GRAVEL
Sewer Service Inspection - R Passed 1/24/2023 1/24/2023 01/24/2023
Misc
Informational
01/24/2023
- 2109 OK -2111 OK
Water Service Inspection - R Passed 1/27/2023 (1:00) 1/27/2023 01/27/2023
Erosion Control Inspection Residential Partial 6/13/2023 06/13/2023
Miscellaneous Correction
Informational
06/13/2023
Erosion control in place at the time of this inspection
Rated Assembly Inspection Passed 6/13/2023 6/13/2023 06/13/2023
Gas Service Inspection - Residential Passed 6/13/2023 6/13/2023 06/13/2023
Electrical Service Inspection Passed 6/13/2023 6/13/2023 06/13/2023
All Rough Inspection - Residential Failed 6/13/2023 6/13/2023 06/13/2023
Miscellaneous Correction
Corrective Action Required
06/13/2023
2111 - Two joist hanger are missing by the basement mechanical room - Triple lvl’s in the garage is missing nails at the joist hanger - Stem wall anchor bolts need to be in the middle 1/3 of bottom plate - Incomplete wall in the utility room - LIB in primary bathroom is cut and needs replaced - LIB missing in upstairs rooms - Fire blocking is missing in upstairs bathroom top plate 2109 - Jack studs do not meet header at living room windows - Utility room has a incomplete wall - Basement anchor bolts need to be tightened down - Address 2x12 cut in basement ceiling joist - Address second story siding and corner where it meets the single story along the east and west sides
All Rough Inspection - Residential Passed 6/14/2023 6/14/2023 06/14/2023
Miscellaneous Correction
Resolved
06/14/2023
2111 - Two joist hanger are missing by the basement mechanical room - Triple lvl’s in the garage is missing nails at the joist hanger - Stem wall anchor bolts need to be in the middle 1/3 of bottom plate - Incomplete wall in the utility room - LIB in primary bathroom is cut and needs replaced - LIB missing in upstairs rooms - Fire blocking is missing in upstairs bathroom top
Driveway Inspection Passed 6/28/2023 6/28/2023 06/27/2023
Misc
Informational
06/23/2023
6-23-23 BR Driveway is framed and aggregate has been place and compacted. Ready for concrete. 6-27-23 BR Driveway is concreted to LS specification.
Sidewalk Inspection Passed 6/28/2023 6/28/2023 06/27/2023
Misc
Informational
06/23/2023
6-23-23 BR Sidewalk is framed and aggregate has been place and compacted. Ready for concrete. 6-27-23 BR Sidewalk is concreted to LS specification
Erosion Control Inspection Residential Passed 8/10/2023 08/10/2023
Miscellaneous Correction
Informational
06/13/2023
Erosion control in place at the time of this inspection
Occupancy Inspection - Codes Residential Failed 8/17/2023 8/17/2023 08/17/2023
Miscellaneous Correction
Corrective Action Required
08/17/2023
2109 - Front porch has a drop off on the east side over 30 inches high an will require a guard rail installed - Range anti tipping bracket is not working or not installed - Breaker marked so soponpe? - First step up from the entry wood floor to the stairs is over the required height of no more than 7 3/4 inches (measurement 8 inches high) 2111 - Microwave plug in has a gap between the face plate and the sheet rock wall - House to garage self closing hinge does not fully shut the door and lock - Top stair to up stairs platform is 6 1/2 inches riser height. The next stair riser down has a riser height of 7 1/2 inches. Code requirements is a riser height of no more than a difference of 3/8 of an inch between risers - Upstairs bathroom vanity is not complete - Water is pooling in the front and west side of the property and is not installed according to the approved plot plan
Occupancy Inspection - Codes Residential Ready for Temp CO 8/22/2023 8/22/2023 08/22/2023
Miscellaneous Correction
Resolved
08/22/2023
2109 - Front porch has a drop off on the east side over 30 inches high an will require a guard rail installed - Range anti tipping bracket is not working or not installed - Breaker marked so soponpe? - First step up from the entry wood floor to the stairs is over the required height of no more than 7 3/4 inches (measurement 8 inches high) 2111 - Microwave plug in has a gap between the face plate and the sheet rock wall - House to garage self closing hinge does not fully shut the door and lock - Top stair to up stairs platform is 6 1/2 inches riser height. The next stair riser down has a riser height of 7 1/2 inches. Code requirements is a riser height of no more than a difference of 3/8 of an inch between risers - Upstairs bathroom vanity is not complete - Water is pooling in the front and west side of the property and is not installed according to the approved plot plan
Miscellaneous Correction
Corrective Action Required
08/22/2023
Exterior sod is still settling down and has not had the final grade completed. TCO on both sides of the duplex has been entered.
Plot Plan Inspection Passed 9/11/2023 09/11/2023
Occupancy Inspection - Codes Residential Full C of O 9/11/2023 9/11/2023 09/11/2023
Miscellaneous Correction
Resolved
09/11/2023
Exterior sod is still settling down and has not had the final grade completed. TCO on both sides of the duplex has been entered.
Documents & Images
Date Uploaded File Type Document Name
11/28/2022 OS #50 - PERMIT APP
11/29/2022 Approved Plans Approved Drawings
11/29/2022 Application Form Approved Truss Package
11/29/2022 Approved Plans Approved Truss Layout
11/29/2022 Permit Codes Residential Plan Review
12/01/2022 Plot Plan Approved Plot Plan
12/01/2022 Permit Codes Residential Plan Review
12/05/2022 Permit DS Building Permit
12/05/2022 Receipt Receipt for transaction:2022-009263
01/15/2023 2109 & 2111 SW Osae Dr LSMO Osae Lot 50 Footin Inspection Report 1-6-23
01/18/2023 Letter INSPECTION SUMMARY
01/18/2023 Letter INSPECTION SUMMARY
01/23/2023 50 OSAGE 1ST FLOOR LAYOUT
01/23/2023 50 OSAGE 2ND FLOOR LAYOUT
01/23/2023 OS #50 -Twin Sienna - Farmhouse - Revised
01/23/2023 Approved Plans APPROVED TRUSS LAYOUT
01/23/2023 Approved Plans APPROVED TRUSS LAYOUT
01/23/2023 Approved Plans APPROVED PLANS
01/24/2023 Letter INSPECTION SUMMARY
01/24/2023 Letter INSPECTION SUMMARY
01/24/2023 Letter INSPECTION SUMMARY
01/26/2023 Approved Plans APPROVED TRUSS PACKAGE
05/02/2023 OS 50 - Basement finish - Scope_of_Work
05/03/2023 Approved Plans APPROVED BASEMENT DRAWING
05/05/2023 Receipt Receipt for transaction:2023-002832
06/13/2023 Letter INSPECTION SUMMARY
06/13/2023 Letter INSPECTION SUMMARY
06/13/2023 Letter INSPECTION SUMMARY
06/13/2023 Letter INSPECTION SUMMARY
06/13/2023 Letter INSPECTION SUMMARY
06/14/2023 Letter INSPECTION SUMMARY
06/23/2023 Letter INSPECTION SUMMARY
06/23/2023 Letter INSPECTION SUMMARY
06/27/2023 Letter INSPECTION SUMMARY
06/27/2023 Letter INSPECTION SUMMARY
08/10/2023 Letter INSPECTION SUMMARY
08/17/2023 Letter INSPECTION SUMMARY
08/22/2023 Certificate/License Codes Temporary Certificate of Occupancy
08/22/2023 Receipt Receipt for transaction:2023-006515
09/11/2023 Letter INSPECTION SUMMARY
09/11/2023 Letter Codes Final Certificate of Occupancy
09/11/2023 Letter Field Certificate of Occupancy
01/29/2024 LOT 50 ASBUILT
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home