Permit Application Status

PRRES20225745


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20225745
Building Permit - Residential
Certificate of Occupancy
DRIPPE HOMES INC
NEW SINGLE FAMILY
NEW HOUSE. WALKOUT BASEMENT. FINISHED/UNFINISHED BASEMENT. COVERED DECK. STOP WORK ORDER generated on 12/15/2022 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 01/05/2023 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER generated on 07/06/2023 12:00 AM by username 'Kyle Beard'. STOP WORK ORDER removed on 07/10/2023 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER generated on 08/23/2023 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 08/24/2023 12:00 AM by username 'Mitchell Schwarz'.
11/16/2022
11/21/2022
05/16/2023
03/14/2024
Locations
Property
69520120500000000

Address
3219 SW ENOCH ST, LEES SUMMIT, MO 64082

69-520-12-05-00-0-00-000
Contacts
Drippe Homes PC, Address:919 E Jesuit Lane  
Drippe Homes, INC, Address:919 E Jesuit Ln  
PRIDE SERVICES INC, Address:3842 GEORGIA TERR, Phone:(785) 242-9700  
PRAIRIE CENTER PLUMBING HEATING & A/C, Address:242 N MARION, Phone:(913) 829-6263  
PRAIRIE CENTER PLUMBING HEATING & A/C, Address:242 N MARION, Phone:(913) 829-6263  
DRIPPE HOMES INC, Address:919 E JESUIT LN  
CSLAVENS@DRIPPEHOMES.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331401-Water Tap Fee $3,730.00 $3,730.00 Paid 11/21/2022
8350015-Water Meter Fee $550.50 $550.50 Paid 11/21/2022
8331507-Sanitary Sewer Development Fee $1,384.00 $1,384.00 Paid 11/21/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 11/21/2022
7232302-Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 11/21/2022
9110078-Valuation Fee New Single Family $1,608.19 $1,608.19 Paid 11/21/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 01/06/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Failed 12/13/2022 12/13/2022
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
12/13/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Footing Inspection - Residential Failed - Stop Work 12/15/2022 12/15/2022
Misc
Corrective Action Required
12/15/2022
third party inspection denied erosion control not in place stop work issued
Erosion Control Inspection Residential Failed 12/28/2022 12/28/2022 12/28/2022
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
12/13/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Corrective Action Required
12/28/2022
Provide gravel filter at lot access
Sewer Service Inspection - R Passed 1/5/2023 (1:30) 1/5/2023 01/05/2023
Footing Inspection - Residential Passed 1/5/2023 01/05/2023
Misc
Resolved
01/05/2023
third party inspection denied erosion control not in place stop work issued
Water Service Inspection - R Partial 1/5/2023 01/05/2023
Misc
Corrective Action Required
01/05/2023
partial pex ran roughly 20' from foundation
Erosion Control Inspection Residential Not Ready 1/5/2023 1/5/2023 01/05/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
12/28/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Corrective Action Required
12/28/2022
Provide gravel filter at lot access
Water Service Inspection - R Passed 1/6/2023 (8:45) 1/6/2023 01/06/2023
Misc
Resolved
01/06/2023
partial pex ran roughly 20' from foundation
Erosion Control Inspection Residential Failed 1/24/2023 01/24/2023
DCM3 ESC REQUIRED 2 DAY
Resolved
01/24/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Corrective Action Required
01/05/2023
- Post address - Provide gravel filter at lot access
Underslab Plumbing Inspection - Residential Failed 1/24/2023 1/24/2023 01/24/2023
Misc
Corrective Action Required
01/24/2023
- Post address - Place drain tile piping in to correct position
Gas Service Inspection - Residential Passed 6/21/2023 6/21/2023 06/21/2023
Misc
Informational
06/21/2023
Pressure okay
All Rough Inspection - Residential Failed - Stop Work 7/6/2023 7/6/2023 07/06/2023
Miscellaneous Correction
Corrective Action Required
07/06/2023
All rough inspection is suspended until failed under slab plumbing (01/24/2023) is resolved. Stop work order is issued as of 07/06/2023 K Beard
Underslab Plumbing Inspection - Residential Passed 7/10/2023 07/10/2023
Misc
Resolved
07/10/2023
- Post address - Place drain tile piping in to correct position
Misc
Informational
07/10/2023
passed per lettered from installer of drain tile.
Electrical Service Inspection Passed 7/10/2023 7/10/2023 07/10/2023
All Rough Inspection - Residential Failed 7/10/2023 7/10/2023 07/10/2023
Miscellaneous Correction
Resolved
07/10/2023
All rough inspection is suspended until failed under slab plumbing (01/24/2023) is resolved. Stop work order is issued as of 07/06/2023 K Beard
Misc
Corrective Action Required
07/10/2023
-fire block top plate penetration at double car garage -uncover covered garages for nailing inspection -top plate penetration to be sealed rear garage wall -protect NM wire within 6’ of attic access -seal dryer vent top plate penetration -primary bath toilet top plate penetration -secure gas line at fireplace -missing nails in hangers right of stairs in basement -anchor bolts to be in the middle 1/3 of sill plate in basement throughout -fireblock wall space to ceiling space in rec room left of slider at furr out -strap top plate penetrations for pex and dwv in bed 4/5 bath -complete closet framing for bed 4 -fire block bed 4 W wall to ceiling space -fire block dead space at shared bath into furr down -secure pex in basement shared bath -missing truss hangers above primary closet and bath -uncover covered front porch to verify hangers -
All Rough Inspection - Residential Failed 7/14/2023 7/14/2023 07/14/2023
Misc
Corrective Action Required
07/10/2023
NO FURTHER INSPECTIONS UNTIL EROSION CONTROL IS IN COMPLIANCE -protect NM wire within 6’ of attic access -seal top plate penetrations for pex and dwv in bed 4/5 bath -fire block bed 4 W wall to ceiling space -fire block dead space at shared bath into furr down
All Rough Inspection - Residential Passed 7/17/2023 7/17/2023 07/17/2023
Misc
Resolved
07/17/2023
NO FURTHER INSPECTIONS UNTIL EROSION CONTROL IS IN COMPLIANCE -protect NM wire within 6’ of attic access -seal top plate penetrations for pex and dwv in bed 4/5 bath -fire block bed 4 W wall to ceiling space -fire block dead space at shared bath into furr down
Driveway Inspection Passed 7/28/2023 7/28/2023 07/28/2023
Misc
Informational
07/25/2023
7-25-23 DP. DW is formed, aggregate compacted. Approved to pour. 7-28-23 BR Driveway is constructed to LS specifications.
Erosion Control Inspection Residential Failed 8/18/2023 08/18/2023
Misc
Resolved
08/18/2023
- Post address - Provide gravel filter at lot access
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/18/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Maintain overgrown vegetation
Erosion Control Inspection Residential Failed - Stop Work 8/23/2023 8/23/2023 08/23/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/18/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Maintain overgrown vegetation
Misc
Corrective Action Required
08/23/2023
Erosion control still not in compliance Stop work issued. -maintain overgrown vegetation -maintain silt fence Mitchell Schwarz 08/23/2023 10:52 AM
Erosion Control Inspection Residential Partial 8/24/2023 8/24/2023 08/24/2023
DCM3 ESC REQUIRED 2 DAY
Resolved
08/24/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Maintain overgrown vegetation
Misc
Resolved
08/24/2023
Erosion control still not in compliance Stop work issued. -maintain overgrown vegetation -maintain silt fence Mitchell Schwarz 08/23/2023 10:52 AM
Misc
Informational
08/24/2023
Erosion control back in compliance 8/24/23
Sidewalk Inspection Partial 9/26/2023 09/26/2023
Misc
Informational
09/26/2023
9-26-23 Sw in rear of house is framed and aggregate is compacted. Slope is in compliance . Approved to pour
Sidewalk Inspection Passed 10/3/2023 10/3/2023 10/02/2023
Misc
Informational
09/26/2023
9-26-23 Sw in rear of house is framed and aggregate is compacted. Slope is in compliance . Approved to pour. 10-2-23 Dustin A, SW is poured. Slopes are in compliance. Forms are pulled. Passed
Erosion Control Inspection Residential Passed 12/08/2023
Misc
Informational
08/24/2023
Erosion control back in compliance 8/24/23
Occupancy Inspection - Codes Residential Failed 12/8/2023 12/8/2023 12/08/2023
Misc
Corrective Action Required
12/08/2023
-Driveway inspection pending -Piers poured without inspection -Install code compliant gaurdrail and handrail at deck -Provide security screws at hinges and strikes of exterior doors -Dishwasher to be GFCI protected -Install splash blocks -sewer tracer wire box to be at grade -Water meter to be 14"-18" to top of can -Stair riser is over 7.75" and varies more than 3/8" at top riser of basement stairs
Piers/Caissons Inspection - Residential Passed 3/14/2024 03/14/2024
Misc
Informational
03/14/2024
Inspection by third party
Plot Plan Inspection Passed 3/14/2024 03/14/2024
Occupancy Inspection - Codes Residential Full C of O 3/14/2024 3/14/2024 03/14/2024
Misc
Resolved
03/14/2024
-Driveway inspection pending -Piers poured without inspection -Install code compliant gaurdrail and handrail at deck -Provide security screws at hinges and strikes of exterior doors -Dishwasher to be GFCI protected -Install splash blocks -sewer tracer wire box to be at grade -Water meter to be 14"-18" to top of can -Stair riser is over 7.75" and varies more than 3/8" at top riser of basement stairs
Documents & Images
Date Uploaded File Type Document Name
11/16/2022 License_Tax_Application
11/17/2022 Permit Codes Residential Plan Review
11/17/2022 Residental Permit Application_1 (1)
11/17/2022 Plot Plan APPROVED PLOT PLAN
11/17/2022 Permit Codes Residential Plan Review
11/18/2022 Approved Plans APPROVED PLANS
11/18/2022 Permit Codes Residential Plan Review
11/21/2022 Permit DS Building Permit
11/21/2022 Receipt Receipt for transaction:2022-009056
12/13/2022 Letter INSPECTION SUMMARY
12/15/2022 3219 SW Enoch St_FTG INSP_2022-12-14
12/15/2022 Letter Stop Work Order
12/28/2022 Letter Stop Work Order
12/28/2022 Letter INSPECTION SUMMARY
01/06/2023 Receipt Receipt for transaction:2023-000091
01/24/2023 Letter INSPECTION SUMMARY
01/24/2023 Letter INSPECTION SUMMARY
01/24/2023 Letter INSPECTION SUMMARY
06/13/2023 Letter INSPECTION SUMMARY
06/13/2023 Letter INSPECTION SUMMARY
06/13/2023 Letter INSPECTION SUMMARY
06/13/2023 Letter INSPECTION SUMMARY
06/13/2023 Letter Codes 140 Day Letter
06/21/2023 Letter INSPECTION SUMMARY
07/06/2023 Letter Stop Work Order
07/07/2023 Gordon Energy rain tile letter
07/10/2023 Letter INSPECTION SUMMARY
07/14/2023 Letter INSPECTION SUMMARY
07/14/2023 Letter INSPECTION SUMMARY
07/14/2023 Letter INSPECTION SUMMARY
07/17/2023 Letter INSPECTION SUMMARY
07/25/2023 Letter INSPECTION SUMMARY
07/28/2023 Letter INSPECTION SUMMARY
08/18/2023 Letter INSPECTION SUMMARY
08/23/2023 Letter Stop Work Order
08/23/2023 Letter Stop Work Order
08/24/2023 Letter INSPECTION SUMMARY
09/26/2023 Letter INSPECTION SUMMARY
10/02/2023 Letter INSPECTION SUMMARY
12/08/2023 Letter INSPECTION SUMMARY
12/08/2023 Letter INSPECTION SUMMARY
03/14/2024 Engineer Report/Study ENGINEER REPORT
03/14/2024 Letter INSPECTION SUMMARY
03/14/2024 Letter INSPECTION SUMMARY
03/14/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home