Summary
PRRES20222410
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - UNFINSIHED BASEMENT -
06/01/2022
06/03/2022
11/29/2022
03/22/2023
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $600.00 $600.00 Paid 06/03/2022
Right of Way Permit Fee $85.00 $85.00 Paid 06/03/2022
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 06/03/2022
Water Tap Fee $3,655.00 $3,655.00 Paid 06/03/2022
Water Meter Fee $479.24 $479.24 Paid 06/03/2022
Valuation Fee New Single Family $1,611.47 $1,611.47 Paid 06/03/2022
Not Ready Inspection Fee $75.00 $75.00 Paid 12/21/2022
Temporary Occupancy Fee $50.00 $50.00 Paid 12/22/2022
Temporary Occupancy Fee $50.00 $50.00 Paid 01/18/2023
Temporary Occupancy Fee $50.00 $50.00 Paid 02/17/2023
Temporary Occupancy Fee $50.00 $50.00 Paid 03/09/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 6/17/2022 (10:45) 6/17/2022 06/17/2022
Misc
Informational
06/17/2022
-UFER at back of garage wall double side 3' from left - footing poured for covered patio 28"x28"
Underslab Plumbing Inspection - Residential Passed 7/13/2022 7/13/2022 07/13/2022
Erosion Control Inspection Residential Failed 7/13/2022 07/13/2022
Misc
Corrective Action Required
07/13/2022
Repair silt fence at front of lot
Sewer Service Inspection - R Passed 7/14/2022 (8:30) 7/14/2022 07/14/2022
Water Service Inspection - R Passed 7/15/2022 (1:00) 7/15/2022 07/15/2022
Erosion Control Inspection Residential Failed 9/23/2022 09/23/2022
Misc
Corrective Action Required
07/13/2022
Repair silt fence at front of lot
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
09/23/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN SILT FENCE & TRASH
Gas Service Inspection - Residential Passed 9/23/2022 9/23/2022 09/23/2022
Electrical Service Inspection Failed 9/23/2022 9/23/2022 09/23/2022
Miscellaneous Correction
Corrective Action Required
09/23/2022
Take a 2nd look after joist repair above service panel
All Rough Inspection - Residential Failed 9/23/2022 9/23/2022 09/23/2022
Miscellaneous Correction
Corrective Action Required
09/23/2022
No deck pier inspection on record Install back ordered windows Provide anchor bolts SCH 40 columns basement Address over bored joist above service panel & seal upward penetration Fold tab Sch 40 column under stairs Provide fire blocking at soffit great room above windows Provide joist hanger 4 joist at stairs near fireplace Complete through bolts at beam great room Provide joist hanger at triple joist at beam great room near light fixture Provide 4 stud pack at girder truss stair landing at front door Strap top plate at dining room corner above beam no overlap Provide electrical protection plates at kitchen sink Seal upward penetrations at sliding glass door Seal fire blocking pantry at garage wall Fire block at conductors above refrigerator Provide angle joist hangers flex room Provide electrical protection plates flex room corner near closet & seal upward penetration Nail exterior wall sheathing per code Seal upward penetrations gas line flex room closet Seal upward penetration DWV bath 4 Seal fire blocking bath 4 / garage Soffit at supply air bath 4 Provide LIBs per plan garage/pantry/ dining per plan Nail LIBs 2 nails top & bottom plate intersecting studs Provide anchor bolt end of plate garage/bath 4 & SCH 40 column Tighten anchor bolts throughout Seal fire blocking garage soffit Missing Ceiling joist garage soffit at light fixture Seal fire blocking dead space at HVAC chase Seal fire blocking dead space bed 1 Provide electrical protection plate bed 1 at dead space Seal tub trap master bath Provide electrical protection plates bed 3 Seal all upward penetrations bed 4
All Rough Inspection - Residential Failed 9/28/2022 9/28/2022 09/28/2022
Miscellaneous Correction
Corrective Action Required
09/23/2022
Address over bored joist above service panel & seal upward penetration Complete through bolts at beam great room
Electrical Service Inspection Passed 9/28/2022 9/28/2022 09/28/2022
Miscellaneous Correction
Resolved
09/28/2022
All Rough Inspection - Residential Not Ready 9/30/2022 9/30/2022 09/30/2022
Miscellaneous Correction
Corrective Action Required
09/28/2022
Address over bored joist above service panel at SEC cable Nail Cs-16 straps per manufactures installation instructions per Everstead letter ( nails )
Driveway Inspection Partial 10/5/2022 10/5/2022 10/05/2022
Misc
Informational
10/05/2022
Driveway was framed up with aggregate in and compacted. 10/5/22 ES
Driveway Inspection Passed 10/14/2022 10/14/2022 10/17/2022
Misc
Informational
10/05/2022
Driveway was framed up with aggregate in and compacted. 10/5/22 ES Driveway meets LS spec. 10/17/22 ES
All Rough Inspection - Residential Passed 12/20/2022 12/20/2022 12/20/2022
Miscellaneous Correction
Resolved
12/20/2022
Address over bored joist above service panel at SEC cable Nail Cs-16 straps per manufactures installation instructions per Everstead letter ( nails )
Occupancy Inspection - Codes Residential Failed 12/20/2022 12/20/2022 12/20/2022
Corrective Action Required
12/20/2022
-final grade and sod -splash blocks -GFCI protection required at dishwasher outlet -install outlet or cover plate at ceiling box above dbl door garage -handrail height between 34”-38” at garage -tempered glass required at lower window of lower landing 2nd floor stairs -bath exhaust fan not operational at 2nd floor bath -label all dedicated outlets at garage and unfinished basement as Not GFCI protected
Occupancy Inspection - Codes Residential Ready for Temp CO 12/22/2022 12/22/2022 12/22/2022
Misc
Corrective Action Required
12/20/2022
-final grade and sod -splash blocks
Occupancy Inspection - Codes Residential Ready for Temp CO 1/18/2023 01/18/2023
Misc
Corrective Action Required
12/22/2022
-final grade and sod -splash blocks
Occupancy Inspection - Codes Residential Ready for Temp CO 2/17/2023 02/17/2023
Misc
Corrective Action Required
01/18/2023
-final grade and sod -splash blocks
Plot Plan Inspection Failed 2/21/2023 2/21/2023 02/21/2023
Misc
Corrective Action Required
02/21/2023
Reinspect when sod is down for water meter hieght.
Erosion Control Inspection Residential Failed 2/22/2023 02/22/2023
Misc
Resolved
02/22/2023
Repair silt fence at front of lot
DCM2 ESC DEFICIENT INSTALLATION
Resolved
02/22/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN SILT FENCE & TRASH
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
02/22/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/22/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/22/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Occupancy Inspection - Codes Residential Ready for Temp CO 3/9/2023 03/09/2023
Misc
Corrective Action Required
02/17/2023
-final grade and sod -splash blocks
Misc
Corrective Action Required
03/09/2023
tco extension approved
Erosion Control Inspection Residential Passed 3/22/2023 03/22/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
03/22/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM2 ESC DEFICIENT INSTALLATION
Resolved
03/22/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM3 ESC REQUIRED 2 DAY
Resolved
03/22/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Plot Plan Inspection Passed 3/22/2023 03/22/2023
Misc
Resolved
03/22/2023
.
Occupancy Inspection - Codes Residential Full C of O 3/22/2023 3/22/2023 03/22/2023
Misc
Resolved
03/22/2023
Misc
Resolved
03/22/2023
tco extension approved
Documents & Images
Date Uploaded File Type Document Name
06/01/2022 W0 #181 - Permit App
06/02/2022 Approved Plans APPROVED PLANS
06/02/2022 Approved Plans APPROVED TRUSS LAYOUT
06/02/2022 Approved Plans APPROVED TRUSS PACKAGE
06/02/2022 Permit Codes Residential Plan Review
06/02/2022 Plot Plan APPROVED PLOT PLAN
06/03/2022 Permit Codes Residential Plan Review
06/03/2022 Permit DS Building Permit
06/03/2022 Receipt Receipt for transaction:2022-004264
06/17/2022 Letter INSPECTION SUMMARY
07/13/2022 Letter INSPECTION SUMMARY
07/13/2022 Letter INSPECTION SUMMARY
07/15/2022 Letter INSPECTION SUMMARY
07/15/2022 Letter INSPECTION SUMMARY
09/23/2022 Letter INSPECTION SUMMARY
09/23/2022 Letter INSPECTION SUMMARY
09/23/2022 Letter INSPECTION SUMMARY
09/28/2022 Letter INSPECTION SUMMARY
09/28/2022 Letter INSPECTION SUMMARY
09/28/2022 Letter INSPECTION SUMMARY
09/29/2022 181 Woodisde Ridge Letter
09/30/2022 Letter INSPECTION SUMMARY
10/05/2022 Letter INSPECTION SUMMARY
10/17/2022 Letter INSPECTION SUMMARY
12/19/2022 181 woodside ridge letter 2 -signed
12/20/2022 Letter INSPECTION SUMMARY
12/20/2022 Letter INSPECTION SUMMARY
12/21/2022 Receipt Receipt for transaction:2022-009625
12/21/2022 181 Woodside Ridge Post Pour Deck Piers
12/21/2022 181rail1
12/21/2022 181rail2
12/22/2022 Certificate/License Codes Temporary Certificate of Occupancy
12/22/2022 Receipt Receipt for transaction:2022-009637
01/17/2023 W0 #181 - TCOExtension
01/18/2023 Certificate/License Codes Temporary Certificate of Occupancy
01/18/2023 Receipt Receipt for transaction:2023-000301
02/17/2023 LOT 181 CITY
02/17/2023 W0 #181 - TCOExtension
02/17/2023 Plot Plan APPROVED AS GRADED PLOT PLAN
02/17/2023 Certificate/License Codes Temporary Certificate of Occupancy
02/17/2023 Receipt Receipt for transaction:2023-000923
02/21/2023 Letter INSPECTION SUMMARY
02/22/2023 Letter INSPECTION SUMMARY
03/02/2023 Plot Plan APPROVED AS GRADED PLOT PLAN
03/09/2023 W0 #181 - TCO Extension 3
03/09/2023 Certificate/License Codes Temporary Certificate of Occupancy
03/09/2023 Receipt Receipt for transaction:2023-001331
03/22/2023 Letter INSPECTION SUMMARY
03/22/2023 Letter INSPECTION SUMMARY
03/22/2023 Letter Field Certificate of Occupancy
03/22/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home