Permit Application Status

PRRES20221450


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20221450
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. WALKOUT BASEMENT. SUSPENDED SLAB (WITH WALKOUT UNDER SUSPENDED GARAGE). ENGINEERED FLOOR SYSTEM - DEFERRED. ROOF TRUSSES - DEFERRED. FINISHED/UNFINISHED BASEMENT. COVERED/UNCOVERED DECK. RETAINING WALL PLANS DEFERRED UNTIL READY TO INSTALL. POOL INSTALLATION BY ANOTHER CONTRACTOR AT A LATER DATE.
04/13/2022
04/28/2022
10/12/2022
03/21/2024
Locations
Contacts
GALE HOMES II INC, Address:400 SW LONGVIEW BLVD, Unit 109, Phone:(816) 761-9292  
Matt Faulkner, Address:400 SW Longview BLVD, Unit:210  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
HATHEWAY ELECTRIC LLC, Address:3125 SW PRYOR RD, Phone:(660) 232-2419  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
MFAULKNER@GALECOMMUNITIES.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $2,651.30 $2,651.30 Paid 04/28/2022
8331507-Sewer Connection Fee $870.00 $870.00 Paid 04/28/2022
Water Tap Fee $3,655.00 $3,655.00 Paid 04/28/2022
Water Meter Fee $479.24 $479.24 Paid 04/28/2022
Right of Way Permit Fee $85.00 $85.00 Paid 04/28/2022
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 04/28/2022
Temporary Occupancy Fee $50.00 $50.00 Paid 09/21/2023
Temporary Occupancy Fee $50.00 $50.00 Paid 03/20/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 03/20/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Piers/Caissons Inspection - Residential Passed 07/19/2022
Misc
Informational
07/19/2022
Third party inspection.
Footing Inspection - Residential Partial 7/20/2022 (2:00) 7/20/2022 07/20/2022
Misc
Corrective Action Required
07/20/2022
Partial, - step downs not boxed in. - complete re-bar
Footing Inspection - Residential Passed 7/21/2022 (8:00) 7/21/2022 07/21/2022
Misc
Resolved
07/21/2022
Partial, - step downs not boxed in. - complete re-bar
Water Service Inspection - R Passed 8/25/2022 (10:00) 8/25/2022 08/25/2022
Underslab Plumbing Inspection - Residential Passed 8/26/2022 8/26/2022 08/26/2022
Erosion Control Inspection Residential Passed 8/26/2022 08/26/2022
Misc
Corrective Action Required
08/26/2022
- REMOVE GRAVEL AND DEBRIS FROM STREET.
Erosion Control Inspection Residential Failed 8/26/2022 08/26/2022
Misc
Corrective Action Required
08/26/2022
-REMOVE GRAVEL AND DEBRIS FROM STREET.
Erosion Control Inspection Residential Failed 2/22/2023 02/22/2023
Misc
Corrective Action Required
08/26/2022
-MAINTAIN GRAVEL FILTER - REMOVE TRASH AND CONSTRUCTION DEBRIS FROM LOT
Miscellaneous Inspection Failed 3/22/2023 03/22/2023
Misc
Corrective Action Required
03/22/2023
moved permit from expired to isseud still framing and MEP's
All Rough Inspection - Residential Failed 5/2/2023 05/02/2023
Misc
Corrective Action Required
05/02/2023
- Add racking support to gable truss GE10 - Address window header in ellas room - Provide missing window main floor stairs - Fire block basement SE corner room, vertical to horizontal every 10’ - Fire block dead space at basement shower at top plate SE - Fire block top of chase room basement SW corner - Fb stud space at soffit to block vertical to horizontal flame spread south end of media room sliding door - Fb penetration top plate basement North west room - Provide door in basement walk out - Tighten anchor bolts basement - Complete basement sub panel - Security blocking at door in sports room - Provide anchor bolt at North west corner of garage - Fb penetration North East corner of garage - Repair flooring at mud room - Pan out electrical at refrigerator - Install fire place on deck and hearth room - Add nails to 2x6” framing corner of hearth room South West - Provide B-vent for hearth fireplace - Nail exterior siding to plans - Provide hanger for glulam to beam connections deck under fireplace - Provide missing deck posts - Provide double 2x10” hanger North side deck
Electrical Service Inspection Failed 5/2/2023 05/02/2023
Misc
Corrective Action Required
05/02/2023
- sub panel incomplete
Gas Service Inspection - Residential Failed 5/2/2023 05/02/2023
Misc
Corrective Action Required
05/02/2023
- missing fireplaces - no shut off valves
Gas Service Inspection - Residential Passed 5/9/2023 05/09/2023
Misc
Resolved
05/09/2023
All Rough Inspection - Residential Failed 5/9/2023 5/9/2023 05/09/2023
Misc
Corrective Action Required
05/02/2023
- Provide missing window main floor stairs - Fb penetration top plate basement North west room - Provide door in basement walk out - Security blocking at door in sports room - - Provide B-vent for hearth fireplace - Nail exterior siding to code ( at sill plate ) - Provide missing deck posts
Electrical Service Inspection Passed 5/9/2023 05/09/2023
Misc
Resolved
05/09/2023
All Rough Inspection - Residential Passed 5/15/2023 5/15/2023 05/15/2023
Misc
Resolved
05/15/2023
Driveway Inspection Partial 7/6/2023 7/6/2023 07/06/2023
Misc
Informational
07/06/2023
7-6-23 DP. Crew has DW formed, aggregate compacted. Approved to pour.
Miscellaneous Inspection Passed 9/19/2023 09/19/2023
Misc
Corrective Action Required
03/22/2023
moved permit from expired to isseud still framing and MEP's
Erosion Control Inspection Residential Passed 9/19/2023 09/19/2023
Misc
Resolved
09/19/2023
-MAINTAIN GRAVEL FILTER - REMOVE TRASH AND CONSTRUCTION DEBRIS FROM LOT
Sewer Service Inspection - R Passed 9/19/2023 09/19/2023
Misc
Informational
09/19/2023
- Sewer stub inside footing
Occupancy Inspection - Codes Residential Failed 9/19/2023 9/19/2023 09/19/2023
Misc
Corrective Action Required
09/19/2023
- electrical outlet not wired correctly bay 2 - Protect GFCI laundry off garage laundry - GFCI protect all in butler’s pantry - GFCI protection for upstairs laundry - Owner entry to be self closing - Tighten and break off set screw at anti siphon device at spigot at water main - Missing nails in joist hangers at deck - Provide (2) 1/2” through bolts at each post to beam connections - Over 3/8” variance on stairs for deck ( bottom step) - Seal all exterior penetrations - Label breaker at pool sub panel - Provide anti temper caps at all compressor - Address no sod on north side of house - Provide engineer report on retaining wall over 4’ at South East corner of house and add to plot plan - Driveway inspection pending
Driveway Inspection Passed 7/13/2023 7/13/2023 09/21/2023
Misc
Informational
07/06/2023
7-6-23 DP. Crew has DW formed, aggregate compacted. Approved to pour. 9-21-23 A.A, DW is poured, forms are pulled. Passed
Occupancy Inspection - Codes Residential Ready for Temp CO 9/21/2023 9/21/2023 09/21/2023
Misc
Corrective Action Required
09/19/2023
- Missing nails in joist hangers at deck - Address no sod on north side of house - Provide engineer report on retaining wall over 4’ at South East corner of house and add to plot plan
Occupancy Inspection - Codes Residential Ready for Temp CO 1/12/2024 01/12/2024
Misc
Corrective Action Required
09/21/2023
- Missing nails in joist hangers at deck - Address no sod on north side of house - Provide engineer report on retaining wall over 4’ at South East corner of house and add to plot plan
Occupancy Inspection - Codes Residential Ready for Temp CO 2/29/2024 02/29/2024
Misc
Corrective Action Required
01/12/2024
- Missing nails in joist hangers at deck - Address no sod on north side of house - Provide engineer report on retaining wall over 4’ at South East corner of house and add to plot plan
Retaining Wall Inspection Passed 3/4/2024 03/04/2024
Misc
Informational
03/04/2024
RETAINING WALL INSPECTION PREFORMED BY THIRD PARTY
Plot Plan Inspection Passed 3/20/2024 03/20/2024
Occupancy Inspection - Codes Residential Full C of O 3/21/2024 03/21/2024
Misc
Resolved
03/21/2024
Documents & Images
Date Uploaded File Type Document Name
04/13/2022 185 SW Winter Rd_ License_Tax_Application
04/13/2022 185 SW Winter Rd_ Permit Application
04/15/2022 Permit Codes Residential Plan Review
04/15/2022 Letter 185 winter r wall letter
04/21/2022 Plot Plan APPROVED PLOT PLAN
04/26/2022 Permit Codes Residential Plan Review
04/28/2022 Permit DS Building Permit
04/28/2022 Receipt Receipt for transaction:2022-002578
05/23/2022 Final_2022_05_20_EngSiteVst_LSMO_Gale Homes
06/28/2022 DW REVISED PIER PLAN Veach Residence Lot 5 Winterset Cedar Creek Lot 5 6-16-22
06/28/2022 Pier Detail
07/18/2022 Veach retaining wall
07/18/2022 Pier inspection report
07/19/2022 Letter INSPECTION SUMMARY
07/19/2022 Approved Plans APPROVED PLANS
07/20/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
08/25/2022 Letter INSPECTION SUMMARY
08/26/2022 Letter INSPECTION SUMMARY
08/26/2022 Letter INSPECTION SUMMARY
08/26/2022 Letter INSPECTION SUMMARY
02/22/2023 Letter Codes 180 Day Letter
02/22/2023 Letter INSPECTION SUMMARY
02/22/2023 180 day inspection extension
03/22/2023 Letter INSPECTION SUMMARY
05/02/2023 Letter INSPECTION SUMMARY
05/02/2023 Letter INSPECTION SUMMARY
05/02/2023 Letter INSPECTION SUMMARY
05/09/2023 Letter INSPECTION SUMMARY
05/09/2023 Letter INSPECTION SUMMARY
05/09/2023 Letter INSPECTION SUMMARY
05/15/2023 Letter INSPECTION SUMMARY
07/06/2023 Letter INSPECTION SUMMARY
09/19/2023 Letter INSPECTION SUMMARY
09/19/2023 Letter INSPECTION SUMMARY
09/19/2023 Letter INSPECTION SUMMARY
09/19/2023 Letter INSPECTION SUMMARY
09/21/2023 Letter INSPECTION SUMMARY
09/21/2023 Certificate/License Codes Temporary Certificate of Occupancy
09/21/2023 Receipt Receipt for transaction:2023-007229
03/04/2024 Letter RETAINING WALL INSPECTION
03/04/2024 Letter INSPECTION SUMMARY
03/20/2024 Letter INSPECTION SUMMARY
03/20/2024 Certificate/License Codes Temporary Certificate of Occupancy
03/20/2024 Certificate/License Codes Temporary Certificate of Occupancy
03/20/2024 Receipt Receipt for transaction:2024-001736
03/21/2024 Letter Field Certificate of Occupancy
03/21/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home