Permit Application Status

PRRES20220622


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20220622
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - PARTIAL FINISHED BASEMENT - COVERED DECK STOP WORK ORDER generated on 07/11/2022 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 07/14/2022 12:00 AM by username 'Mitchell Schwarz'.
02/18/2022
03/16/2022
10/12/2023
Locations
Contacts
IQ CONSTRUCTION, Address:P O BOX 6423, Phone:(816) 582-8100  
Jennifer Pestka, Address:p o box 6423  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
SAFEHOUSE ELECTRIC COMPANY, Address:P O BOX 1833, Phone:(816) 935-8113  
GARRISON PLUMBING, Address:15430 S MAHAFFIE ST STE 102, Phone:(913) 768-1311  
BSHELTON@IQHOMEBUILDERS.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,161.01 $1,161.01 Paid 03/16/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 03/16/2022
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 03/16/2022
8331507-Sewer Connection Fee $450.00 $450.00 Paid 03/16/2022
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 03/16/2022
8350015-Water Meter Fee $479.24 $479.24 Paid 03/16/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 02/07/2023
9110080-3rd and Subsequent Inspection Fee (Per Hour) $75.00 $75.00 Paid 03/02/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Failed 3/31/2022 03/31/2022
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
03/31/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Mitchell Schwarz 03/31/2022 3:38 PM
Underslab Plumbing Inspection - Residential Not Ready 5/19/2022 5/19/2022 05/19/2022
Sewer Service Inspection - R Passed 5/23/2022 (3:30) 5/23/2022 05/23/2022
Water Service Inspection - R Passed 5/27/2022 (1:00) 5/27/2022 05/27/2022
Underslab Plumbing Inspection - Residential Failed 7/11/2022 7/11/2022 07/11/2022
Misc
Corrective Action Required
07/11/2022
inspection denied address footing poured without inspection.
Footing Inspection - Residential Failed - Stop Work 7/11/2022 07/11/2022
Misc
Corrective Action Required
07/11/2022
footing poured without inspection, provide third party inspection report.
Underslab Plumbing Inspection - Residential Failed 7/14/2022 7/14/2022 07/14/2022
Misc
Corrective Action Required
07/11/2022
inspection denied address footing poured without inspection.
Footing Inspection - Residential Failed 7/14/2022 07/14/2022
Misc
Corrective Action Required
07/14/2022
footing poured without inspection, provide third party inspection report. Third party inspection does not meet the requirements of the citys third party footing inspection report.
Footing Inspection - Residential Passed 7/22/2022 07/22/2022
Misc
Resolved
07/22/2022
footing poured without inspection, provide third party inspection report. Third party inspection does not meet the requirements of the citys third party footing inspection report.
Underslab Plumbing Inspection - Residential Passed 7/22/2022 7/22/2022 07/22/2022
Misc
Resolved
07/22/2022
inspection denied address footing poured without inspection.
Electrical Service Inspection Passed 2/8/2023 2/8/2023 02/08/2023
Gas Service Inspection - Residential Passed 2/8/2023 2/8/2023 02/08/2023
All Rough Inspection - Residential Failed 2/8/2023 2/8/2023 02/08/2023
Misc
Corrective Action Required
02/08/2023
MAINTAIN EROSION CONTROL -stud packs per plans at beam ends in garage -fire block fire place wall to ceiling space -missing ceiling joist hangers above great room/master entry -missing ceiling joist hanger above mast closet -missing ceiling joist hangers above entry/bed 3 entry -missing joist hangers above bed3/2 bath -fire block top of bed 2 E wall to ceiling space -provide support for furr downs ceiling joists in basement to floor joists above or properly install with joist hangers -nail and install exterior wall corner studs together to code see mechanical area of basement and bed 4 missing studs and nails -fire block bed 5 N wall to ceiling space. (Seal penetrations) -missing studs for atud pack under beam in bed 4 -missing nails in hanger at deck -plans call for 3 stud pack under deck beam
All Rough Inspection - Residential Failed 2/28/2023 2/28/2023 02/28/2023
Misc
Corrective Action Required
02/08/2023
-provide support for furr downs ceiling joists in basement to floor joists above or properly install with joist hangers -missing studs for stud pack under beam in bed 4 plans call for 7 -plans call for 3 stud pack under deck beam OKAY TO INSULATE
All Rough Inspection - Residential Failed 3/1/2023 3/1/2023 03/01/2023
Misc
Corrective Action Required
02/28/2023
-address plans call for 3 stud pack under deck beam OKAY TO INSULATE
All Rough Inspection - Residential Failed 3/3/2023 3/3/2023 03/03/2023
Misc
Corrective Action Required
03/01/2023
-address plans call for 3 stud pack under deck beam Not built to plans OKAY TO INSULATE
All Rough Inspection - Residential Failed 3/7/2023 3/7/2023 03/07/2023
Misc
Corrective Action Required
03/03/2023
-address plans call for 3 stud pack under deck beam Not built to plans Not completed as engineers letter 3/7/23 OKAY TO INSULATE
All Rough Inspection - Residential Passed 3/10/2023 3/10/2023 03/10/2023
Misc
Resolved
03/10/2023
Driveway Inspection Partial 5/4/2023 5/4/2023 05/04/2023
Misc
Informational
05/04/2023
5-4-23 RH. Driveway is formed up and aggregate is placed and compacted. Approved to pour.
Sidewalk Inspection Partial 5/4/2023 5/4/2023 05/04/2023
Misc
Informational
05/04/2023
5-4-23 RH. Sidewalk is formed up and aggregate is placed and compacted. Approved to pour.
Driveway Inspection Passed 5/11/2023 5/11/2023 05/12/2023
Misc
Informational
05/04/2023
5-4-23 RH. Driveway is formed up and aggregate is placed and compacted. Approved to pour. 5-12-23 RH. Driveway meets LS and ADA specification.
Sidewalk Inspection Passed 05/12/2023
Misc
Informational
05/12/2023
5-5-12 RH. Sidewalk is formed up and aggregate is placed and compacted. Approved to pour. 5-12-23 RH. Sidewalk meets LS and ADA specification.
Erosion Control Inspection Residential Failed 07/20/2023
DCM3 ESC REQUIRED 2 DAY
Resolved
07/20/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Mitchell Schwarz 03/31/2022 3:38 PM
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
07/20/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Establish erosion control and maintain overgrown vegetation
Occupancy Inspection - Codes Residential Failed 9/21/2023 9/21/2023 09/21/2023
Miscellaneous Correction
Corrective Action Required
09/21/2023
First step up from the basement to the stairwell has a riser height of 8 1/4 inches, code is maximum of 7 3/4 inches (R 311.7.5.1) Stairway steps can not be more than 3/8 of an inch in difference between continuous steps. First riser step up from the basement is 8 1/4 inches high, the second step up is 7 5/8 inches in height (R 311.7.5.1) Last step up to the main living area has a 8 inch riser in height, code is no more than a riser height of 7 3/4 inches (R 311.7.5.1) Basement walkout door needs to have (2) 3 inch security screws in each hinge and two locking devices Furnace gas line is missing a condensate drain Interior of garage vertical boards above the overhead doors at the ceiling need to be sealed (fire blocked) (R 302.11) Seal top of A/C disconnect Seal top of electrical service meter Seal top of front exterior lights Lawn sprinkler system installed without permit. Permit is required
Miscellaneous Correction
Corrective Action Required
09/21/2023
First step up from the basement to the stairwell has a riser height of 8 1/4 inches, code is maximum of 7 3/4 inches (R 311.7.5.1) Stairway steps can not be more than 3/8 of an inch in difference between continuous steps. First riser step up from the basement is 8 1/4 inches high, the second step up is 7 5/8 inches in height (R 311.7.5.1) Last step up to the main living area has a 8 inch riser in height, code is no more than a riser height of 7 3/4 inches (R 311.7.5.1) Basement walkout door needs to have (2) 3 inch screws in each hinge and two locking devices per door Furnace is missing a condensate drain Interior of garage vertical boards above the overhead doors at the ceiling need to be sealed (fire blocked) (R 302.11) Seal top of A/C disconnect Seal top of electrical service meter Seal top of front exterior lights Lawn sprinkler system installed without permit. Permit is required
Plot Plan Inspection Passed 9/21/2023 09/21/2023
Erosion Control Inspection Residential Passed 9/21/2023 09/21/2023
DCM3 ESC REQUIRED 2 DAY
Resolved
09/21/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Establish erosion control and maintain overgrown vegetation
Occupancy Inspection - Codes Residential Full C of O 9/28/2023 10/12/2023 10/12/2023
Miscellaneous Correction
Resolved
10/12/2023
First step up from the basement to the stairwell has a riser height of 8 1/4 inches, code is maximum of 7 3/4 inches (R 311.7.5.1) Stairway steps can not be more than 3/8 of an inch in difference between continuous steps. First riser step up from the basement is 8 1/4 inches high, the second step up is 7 5/8 inches in height (R 311.7.5.1) Last step up to the main living area has a 8 inch riser in height, code is no more than a riser height of 7 3/4 inches (R 311.7.5.1) Basement walkout door needs to have (2) 3 inch security screws in each hinge and two locking devices Furnace gas line is missing a condensate drain Interior of garage vertical boards above the overhead doors at the ceiling need to be sealed (fire blocked) (R 302.11) Seal top of A/C disconnect Seal top of electrical service meter Seal top of front exterior lights Lawn sprinkler system installed without permit. Permit is required
Documents & Images
Date Uploaded File Type Document Name
02/18/2022 2026 SW Red Barn Lane - Permit and Tax Applications
02/22/2022 Approved Plans Approved Drawings
02/22/2022 Permit Codes Residential Plan Review
02/24/2022 Plot Plan Approved Plot Plan
02/24/2022 Permit Codes Residential Plan Review
03/16/2022 Permit DS Building Permit
03/16/2022 Receipt Receipt for transaction:2022-001428
03/31/2022 Letter INSPECTION SUMMARY
05/19/2022 Letter INSPECTION SUMMARY
05/23/2022 Letter INSPECTION SUMMARY
05/27/2022 Letter INSPECTION SUMMARY
07/11/2022 Letter INSPECTION SUMMARY
07/11/2022 Letter Stop Work Order
07/12/2022 2026 SW RED BARN LN FTG INSP
07/13/2022 2026 SW RED BARN LANE FTG INSP REV
07/14/2022 Letter INSPECTION SUMMARY
07/14/2022 Letter INSPECTION SUMMARY
07/18/2022 2026 SW RED BARN LN FOOTING LSMO
07/21/2022 2026 SW RED BARN LANE FTG REV2
07/21/2022 Letter INSPECTION SUMMARY
07/22/2022 Letter INSPECTION SUMMARY
07/22/2022 Letter INSPECTION SUMMARY
12/13/2022 Letter Codes 140 Day Letter
01/18/2023 Letter Codes 180 Day Letter
02/07/2023 Receipt Receipt for transaction:2023-000733
02/08/2023 Letter INSPECTION SUMMARY
02/08/2023 Letter INSPECTION SUMMARY
02/08/2023 Letter INSPECTION SUMMARY
02/28/2023 Letter INSPECTION SUMMARY
03/01/2023 Letter INSPECTION SUMMARY
03/02/2023 Receipt Receipt for transaction:2023-001197
03/03/2023 Letter INSPECTION SUMMARY
03/06/2023 Structural Letter - 2026 SW Red Barn Lane
03/07/2023 Letter INSPECTION SUMMARY
03/10/2023 Letter INSPECTION SUMMARY
05/04/2023 Letter INSPECTION SUMMARY
05/04/2023 Letter INSPECTION SUMMARY
05/12/2023 Letter INSPECTION SUMMARY
05/12/2023 Letter INSPECTION SUMMARY
07/20/2023 Letter INSPECTION SUMMARY
07/20/2023 Letter INSPECTION SUMMARY
09/21/2023 Letter INSPECTION SUMMARY
09/21/2023 Letter INSPECTION SUMMARY
09/21/2023 Letter INSPECTION SUMMARY
10/12/2023 Letter Field Certificate of Occupancy
10/12/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home