Summary
PRRES20220465
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK - ATTACHED AND DETACHED GARAGE APPLICANT PAID SIDEWALK DEPOSIT IN LIEU OF INSTALLING THE REQUIRED SIDEWALK - LETTER FROM RYAN ELAM ATTACHED PRIVATE SANITARY DISPOSAL SYSTEM
02/07/2022
03/02/2022
08/08/2022
01/09/2023
Locations
Contacts
SIGNATURE BUILDERS KC LLC, Address:1516 SW HOOK RD, Phone:(816) 215-0891  
William H Barnard, Address:2751 NE Douglas Street / Suite V, Phone:(816) 215-0891  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
PREMIER ELECTRIC & LIGHTING DESIGN, Address:PO BOX 1311, Phone:(816) 564-7660  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 03/02/2022
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 03/02/2022
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 03/02/2022
8350015-Water Meter Fee $479.24 $479.24 Paid 03/02/2022
9110078-Valuation Fee New Single Family $1,977.93 $1,977.93 Paid 03/02/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 12/09/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 3/21/2022 03/21/2022
Misc
Informational
03/21/2022
(2) Ufer locations: 1near 5' west of Northeast corner, one near 16' east of Southwest corner
Underslab Plumbing Inspection - Residential Passed 4/19/2022 4/19/2022 04/19/2022
Water Service Inspection - R Passed 4/21/2022 (10:00) 4/21/2022 04/21/2022
Misc
Informational
04/20/2022
PEX from street about 250’ to house
Water Service Inspection - R Passed 4/20/2022 (11:30) 4/20/2022 04/21/2022
Misc
Resolved
04/21/2022
PEX from street about 250’ to house
Footing Inspection - Residential Failed 4/28/2022 (8:00) 4/28/2022 04/28/2022
Misc
Corrective Action Required
04/28/2022
-Provide min 16" width per plan -Secure rebar to be min 3" from earth at sides of footing -Clear out loose soil and debris
Footing Inspection - Residential Passed 6/7/2022 (8:00) 6/7/2022 06/07/2022
Misc
Resolved
06/07/2022
-Provide min 16" width per plan -Secure rebar to be min 3" from earth at sides of footing -Clear out loose soil and debris
All Rough Inspection - Residential Failed 8/17/2022 8/17/2022 08/17/2022
Miscellaneous Correction
Corrective Action Required
08/17/2022
***Address Gravel filter before any further inspections **Detached garage -complete electrical -Complete PFG per details-anchor bolts, nailing pattern, plate to header nailis, etc -Tighten anchor bolts -Provide anchor bolts within 12” of plate breaks and at ends of plates -Provide (3) studs at exterior corners and nail per code -Provide lateral restraint at ceiling joists above beam -Missing joist hanger at tail joist for attic access -Seal top plate penetrations at header -Provide security blocking at man door *Main house -Complete PFG per detail-nailing pattern, anchor bolts, nails from plate to header -Tighten anchor bolts, provide anchor bolts within 12” of end of plates, anchor bolts to be in middle third of plate -Solon block between joists at beam -Seal top plate penetration near electrical panel -Fireblock beam webs in finished walls throughout -Structural straps at over bored top plates to have (4) 10d nails each side throughout -Solid block all ceiling joists above load bearing walls -Address over notched stud at laundry exterior wall -Seal top plate at laundry -Provide proper slope and support vent pipe in attic space at master -Fireblock through floor penetration at master tub -Replace stud cut off at master bath/ stair wall -strap top plate lapped less than 24” at master doorway exterior wall -Address over notched joist and rafter in hall outside of master at kitchen entry -Support dwv in attic space at powder room -Provide stud shoe at over bored studs in kitchen -provide min 1” to combustibles at fireplace vent-see middle stud near electrical receptacle -Seal top plate penetrations at bonus room bath by entry -Fireblock ceiling line at exterior wall in bonus room -Solid block between ceiling joists above beams in basement -Fireblock at pex and notched plate at 1/2 bath -Seal plate penetration at guest room entry -Anchor sill plate at guest entry -Provide (3) studs at all exterior corners -Provide anchor bolt at plate ends in guest room -Missing nuts at anchor bolts in guest room -Support flat framed ceiling joists to ceiling joists throughout -Fireblock at ceiling line at guest closet -Fireblock dead space at media room -Security blocking at basement door -Tighten anchor bolts throughout -Double joists under fireplace per plan -Tighten bolts on sch 40 columns -Provide (2) 1/2” through bolts at all post to beam connections at deck -Install missing hangers and corner brackets at deck -Address deck “post” in guest room. This is used and not stud grade lumber, is not bearing on the sill plate, is not nailed per code, not connected to beam per code, etc.
Electrical Service Inspection Failed 8/17/2022 8/17/2022 08/17/2022
Misc
Corrective Action Required
08/17/2022
-Complete sub panel at detached garage
Gas Service Inspection - Residential Passed 8/17/2022 8/17/2022 08/17/2022
Electrical Service Inspection Failed 8/19/2022 08/19/2022
Misc
Corrective Action Required
08/17/2022
-Complete sub panel at detached garage -not complete 8/19/22
All Rough Inspection - Residential Failed 8/19/2022 08/19/2022
Miscellaneous Correction
Corrective Action Required
08/17/2022
***Address Gravel filter before any further inspections **Detached garage -complete electrical -Complete PFG per details-anchor bolts, nailing pattern, plate to header nailis, etc *Main house -Complete PFG per detail-nailing pattern, anchor bolts, nails from plate to header -Provide stud shoe at over bored studs in kitchen ( now address jack stud ) -Provide (2) 1/2” through bolts at all post to beam connections at deck -Address deck “post” in guest room. This is not bearing on the sill plate, is not nailed per code, not connected to beam per code, etc.
Erosion Control Inspection Residential Failed 08/22/2022
DCM5 ESC INSP DENIED
Corrective Action Required
08/22/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. - Address Gravel filter before any further inspections
All Rough Inspection - Residential Failed 8/22/2022 8/22/2022 08/22/2022
Miscellaneous Correction
Corrective Action Required
08/19/2022
***Address Gravel filter before any further inspections **Detached garage -complete electrical -Complete PFG per details-anchor bolts, nailing pattern, plate to header nailis, etc *Main house -Complete PFG per detail-nailing pattern, anchor bolts, nails from plate to header -Provide stud shoe at over bored studs in kitchen ( now address jack stud ) -Provide (2) 1/2” through bolts at all post to beam connections at deck -Address deck “post” in guest room. This is not bearing on the sill plate, is not nailed per code, not connected to beam per code, etc.
Misc
Corrective Action Required
08/22/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. - Address Gravel filter before any further inspections
All Rough Inspection - Residential Passed 8/23/2022 8/23/2022 08/23/2022
Miscellaneous Correction
Resolved
08/23/2022
Misc
Resolved
08/23/2022
Electrical Service Inspection Passed 8/26/2022 08/26/2022
Misc
Resolved
08/26/2022
-Complete sub panel at detached garage -not complete 8/19/22
Foundation Inspection - Residential Passed 12/06/2022
Piers/Caissons Inspection - Residential Passed 4/25/2022 (11:15) 12/06/2022
Occupancy Inspection - Codes Residential Failed 12/6/2022 12/6/2022 12/06/2022
Miscellaneous Correction
Corrective Action Required
12/06/2022
-Final grade and sod -Provide missing splash blocks/ foundation drainage -Open electrical box at SE exterior -Boxes to be flush with combustible finishes at entry switches -Missing cover plate at front bed -Garage door to self close and latch -Secure handrail at top of loft stairs -Secure handrail to basement -Correct gaps larger than 4" at deck railing
Occupancy Inspection - Codes Residential Ready for Temp CO 12/9/2022 12/9/2022 12/09/2022
Miscellaneous Correction
Corrective Action Required
12/06/2022
-Final grade and sod
Erosion Control Inspection Residential Passed 01/09/2023
Plot Plan Inspection Passed 01/09/2023
Occupancy Inspection - Codes Residential Full C of O 1/9/2023 1/9/2023 01/09/2023
Miscellaneous Correction
Resolved
01/09/2023
-Final grade and sod
Documents & Images
Date Uploaded File Type Document Name
02/07/2022 Signed Permit Application 2330 NE Ranson Road
02/07/2022 Signed License Tax 2330 NE Ranson Road
02/08/2022 Letter Payment In Lieu of SW
02/09/2022 Permit Codes Residential Plan Review
02/11/2022 Copy of Deed
02/17/2022 Response to Plan review comments
02/18/2022 Plot Plan Approved Plot Plan
02/22/2022 Approved Plans Approved Drawings
02/22/2022 Permit Codes Residential Plan Review
03/02/2022 Permit DS Building Permit
03/02/2022 Receipt Receipt for transaction:2022-001101
03/21/2022 Letter INSPECTION SUMMARY
03/22/2022 2330 SE Ranson Rd_FTG INSP_2022-03-21
04/07/2022 2330 SE Ranson Rd_WALL INSP_2022-04-06
04/19/2022 Letter INSPECTION SUMMARY
04/20/2022 Letter INSPECTION SUMMARY
04/21/2022 Letter INSPECTION SUMMARY
04/25/2022 Letter INSPECTION SUMMARY
04/25/2022 Letter INSPECTION SUMMARY
04/28/2022 Letter INSPECTION SUMMARY
06/07/2022 Letter INSPECTION SUMMARY
08/09/2022 Approved Plans Approved Floor Joist Drawing
08/17/2022 Letter INSPECTION SUMMARY
08/17/2022 Letter INSPECTION SUMMARY
08/17/2022 Letter INSPECTION SUMMARY
08/17/2022 Letter INSPECTION SUMMARY
08/19/2022 Letter INSPECTION SUMMARY
08/19/2022 Letter INSPECTION SUMMARY
08/22/2022 Letter INSPECTION SUMMARY
08/22/2022 Letter INSPECTION SUMMARY
08/23/2022 Letter INSPECTION SUMMARY
08/26/2022 Letter INSPECTION SUMMARY
12/06/2022 Letter INSPECTION SUMMARY
12/06/2022 Letter INSPECTION SUMMARY
12/09/2022 Letter INSPECTION SUMMARY
12/09/2022 Certificate/License Codes Temporary Certificate of Occupancy
12/09/2022 Receipt Receipt for transaction:2022-009399
01/09/2023 Letter INSPECTION SUMMARY
01/09/2023 Letter INSPECTION SUMMARY
01/09/2023 Letter Codes Final Certificate of Occupancy
01/09/2023 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.