Permit Application Status

PRRES20220422


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20220422
Building Permit - Residential
Certificate of Occupancy
CLAYTON PROPERTIES GROUP INC
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. ROOF TRUSSES. COVERED PATIO. STOP WORK ORDER generated on 03/17/2022 12:00 AM by username 'Patrick Schonfeldt'. STOP WORK ORDER removed on 03/24/2022 12:00 AM by username 'Patrick Schonfeldt'.
02/02/2022
02/10/2022
08/03/2022
04/11/2023
Locations
Contacts
  
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
THAD@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $570.00 $570.00 Paid 02/10/2022
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 02/10/2022
8350015-Water Meter Fee $479.24 $479.24 Paid 02/10/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 02/10/2022
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 02/10/2022
9110078-Valuation Fee New Single Family $1,297.08 $1,297.08 Paid 02/10/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 03/24/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Not Ready 3/17/2022 3/17/2022 03/17/2022
Misc
Corrective Action Required
03/17/2022
INSPECTION DENIED FOOTING POURED WITHOUT INSPECTION, ENGINEER REPORT REQUIRED TO BE UPLOADED WITHIN 48 HOURS OF INSPECTION
Footing Inspection - Residential Failed - Stop Work 3/17/2022 3/17/2022 03/17/2022
Misc
Corrective Action Required
03/17/2022
FOOTING POURED WITHOUT INSPECTION, ENGINEER REPORT REQUIRED TO BE UPLOADED TO PERMIT WITHIN 48 HOURS OF INSPECTION
Footing Inspection - Residential Passed 3/24/2022 3/24/2022 03/24/2022
Misc
Corrective Action Required
03/17/2022
APPROVED PER BRADLEY HUXOL 2/23/22
Sewer Service Inspection - R Passed 4/11/2022 (10:30) 4/11/2022 04/11/2022
Water Service Inspection - R Passed 4/12/2022 (9:00) 4/12/2022 04/12/2022
Underslab Plumbing Inspection - Residential Passed 9/12/2022 9/12/2022 09/12/2022
Misc
Resolved
09/12/2022
Erosion Control Inspection Residential Partial 9/12/2022 9/12/2022 09/12/2022
Electrical Service Inspection Passed 9/12/2022 9/12/2022 09/12/2022
Gas Service Inspection - Residential Passed 9/12/2022 9/12/2022 09/12/2022
All Rough Inspection - Residential Failed 9/12/2022 9/12/2022 09/12/2022
Misc
Corrective Action Required
09/12/2022
-nail exterior sheathing garage PFH per plans -provide attic ventilation covered deck -land electrical to box at East garage wall -fur down at HVAC garage ceiling for R-19 insulation -fireblock fridge cantilever at garage, open to furred down -seal penetrations at rim joist, plumbing fur out garage wall -secure all vertical DWV 2” or less at mid point -pan off air returns at kitchen wall, not just tyvek paper separating return from furred downs -used approved joist hangers for material used, LUS28 2x8 hangers used for 2x10 floor joists -nail off all joist hangers -provide joist hanger at dbl joist to lvl connection great room -security blocking at rear deck door -seal plumbing floor penetrations at great room chase -fireblock plumbing chase at great room, by code if using unfaced insulation must be 16” thick with support -provide joist hanger at dbl joist to header connection above foyer closet -provide dbl joist hanger at joist to be beam connection at pantry wall, pantry wall non load bearing wall -top corner lap connection required at exterior wall connection beneath beam west side dining room ext wall -provide attic access garage per plans -(2) 2x4 trimmer studs garage entry per plans -(2) 2x4 stud packs at East garage wall per plans -5.5”x9.25” glulam or (3) 1 3/4” x 9 1/4” lvl at garage per plans, spans from beam to fridge cantilever -solid block all sheathing breaks -seal top plate roe strains -2nd floor bed closet -provide H2.5 hold down clips, both plies of dbl girder trusses 2nd floor -provide bocca protection plates at top and bottom plate master closet/shower wall -fireblock tub trap 2nd floor bath -provide (4) 2X stud packs at all girder truss bearing ends per plans -provide all truss lateral bracing per plans -solid block between joists above beam at basement stair wall -nail off joist hangers basement
All Rough Inspection - Residential Failed 10/5/2022 10/5/2022 10/05/2022
Misc
Corrective Action Required
09/12/2022
-land electrical to box at East garage wall, kitchen wall -kitchen/garage wall, pan off at furred down for return air and not just tyvek paper, fireblock on non air return stud cavities by providing solid blocking at soffit line -seal plumbing floor penetrations at great room chase -fireblock plumbing chase at great room, seal annular space around plumbing -move electrical above attic access opening garage and protect electrical within 6' of opening -fireblock tub trap 2nd floor bath (see open space where foam has fallen) -nail off joist hangers basement
All Rough Inspection - Residential Passed 10/10/2022 10/10/2022 10/10/2022
Misc
Resolved
10/10/2022
Driveway Inspection Passed 11/21/2022 11/21/2022 11/21/2022
Misc
Informational
11/21/2022
On Monday, 11-21-2022 I inspected and passed a driveway inspection for placement of concrete.
Sidewalk Inspection Partial 1/13/2023 1/13/2023 01/13/2023
Misc
Informational
01/13/2023
1-13-23 RH. Sidewalk is formed up and aggregate is placed and compacted. Approved to pour.
Sidewalk Inspection Passed 1/20/2023 1/20/2023 01/20/2023
Misc
Informational
01/20/2023
1/20/23 PS Sidewalk meets ADA and LS specifications
Occupancy Inspection - Codes Residential Failed 2/8/2023 2/8/2023 02/08/2023
Misc
Corrective Action Required
02/08/2023
_ finial grading and sod - Splash blocks - Sump discharge minimum of 36” from foundation - Provide secondary lock on back door - Provide spindles for garage stairs over 30” - Seal top of light fixtures at garage - Seal top of electrical meter and A/C disconnect
Piers/Caissons Inspection - Residential Passed 2/8/2023 02/08/2023
Misc
Informational
02/08/2023
Inspection completed by third party inspection
Erosion Control Inspection Residential Failed 11/14/2022 2/8/2023 02/08/2023
Misc
Corrective Action Required
02/08/2023
- Remove debris and gravel from street
Occupancy Inspection - Codes Residential Full C of O 4/11/2023 4/11/2023 04/11/2023
Misc
Resolved
04/11/2023
- Provide secondary lock on back door - Provide spindles for garage stairs over
Documents & Images
Date Uploaded File Type Document Name
02/02/2022 CB #25 - PERMIT APPLICATION
02/04/2022 Permit Codes Residential Plan Review
02/09/2022 Plot Plan APPROVED PLOT PLAN
02/10/2022 Approved Plans APPROVED DRAWINGS
02/10/2022 Approved Plans APPROVED TRUSS LAYOUT
02/10/2022 Approved Plans APPROVED TRUSS PACKAGE
02/10/2022 Permit Codes Residential Plan Review
02/10/2022 Permit DS Building Permit
02/10/2022 Receipt Receipt for transaction:2022-000743
03/17/2022 Letter INSPECTION SUMMARY
03/17/2022 Letter Stop Work Order
03/24/2022 25 Cobey Creek FTNG 1
03/24/2022 Receipt Receipt for transaction:2022-001628
03/24/2022 Letter INSPECTION SUMMARY
04/11/2022 Letter INSPECTION SUMMARY
04/12/2022 Letter INSPECTION SUMMARY
07/26/2022 CB 25 - Engineering Letter - Covered Patio - Transom window header
08/29/2022 Strong-Drive® SDWC TRUSS PT3
09/12/2022 Letter INSPECTION SUMMARY
09/12/2022 Letter INSPECTION SUMMARY
09/12/2022 Letter INSPECTION SUMMARY
09/12/2022 Letter INSPECTION SUMMARY
09/12/2022 Letter INSPECTION SUMMARY
09/26/2022 CB 25 - Updated Truss Layout
09/26/2022 Approved Plans APPROVED TRUSS PACKAGE
09/26/2022 Approved Plans APPROVED UPDATED DRAWING
09/27/2022 Approved Plans APPROVED TRUSS LAYOUT
10/05/2022 Letter INSPECTION SUMMARY
10/10/2022 Letter INSPECTION SUMMARY
11/21/2022 Letter INSPECTION SUMMARY
01/13/2023 Letter INSPECTION SUMMARY
01/20/2023 Letter INSPECTION SUMMARY
02/08/2023 Letter INSPECTION SUMMARY
02/08/2023 Letter INSPECTION SUMMARY
02/08/2023 Letter INSPECTION SUMMARY
04/11/2023 Letter Field Certificate of Occupancy
04/11/2023 Letter Codes Final Certificate of Occupancy
04/11/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home