PRRES20220402
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. ROOF TRUSSES. COVERED PATIO.
01/31/2022
02/10/2022
08/06/2022
03/13/2023
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CMH PARKS INC, Address:5000 CLAYTON RD  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
AJ@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $450.00 $450.00 Paid 02/10/2022
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 02/10/2022
8350015-Water Meter Fee $479.24 $479.24 Paid 02/10/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 02/10/2022
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 02/10/2022
9110078-Valuation Fee New Single Family $1,151.52 $1,151.52 Paid 02/10/2022
8331504-EFHB Middle Big Creek, Full $502.20 $502.20 Paid 02/10/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Passed 5/4/2022 5/4/2022 05/04/2022
Sewer Service Inspection - R Passed 5/6/2022 (9:30) 5/6/2022 05/06/2022
Water Service Inspection - R Passed 5/9/2022 (8:45) 5/9/2022 05/09/2022
Erosion Control Inspection Residential Failed 5/9/2022 5/9/2022 05/09/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
05/09/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Electrical Service Inspection Passed 7/29/2022 7/29/2022 07/29/2022
Gas Service Inspection - Residential Passed 7/29/2022 7/29/2022 07/29/2022
All Rough Inspection - Residential Failed 7/29/2022 7/29/2022 07/29/2022
Misc
Corrective Action Required
07/29/2022
-provide bocca protection plate DWV at fur down to fur out soffit end garage wall -provide joist hanger at joist header connection HVAC chase garage entry, joist supported by non load bearing wall -seal all penetrations through air returns -fireblock box out chase great room -provide full height corner studs at rear exterior door -12” oc nailing all abutting and intersecting corners -provide (3) 2x4 stud pack at (2) 9 1/4” lvl great room, make sure stud pack is supporting load point which both lvls cross top plate -provide top plate corner lap connection front entry wall at closet -provide 3” SCH 40 steel column at garage steel beam per plans -2x10 joist split at pantry -(2) 2x10 at great room stair wall per plans -solid block along top plate at sheathing break 2x6 stair wall, nail exterior sheathing to blocking per plans -min 24” lap between dbl top plate breaks - see bed#3 -relocate HVAC duct at attic entry 2nd floor to provide required net clear opening per code -provide all truss hangers per plans -provide nail protection plate sump pump discharge line basement stair wall -provide 1” clearance at b vent basement -provide joist hanger at basement stair wall, 2x10 not supported 1 1/2” on plate -nail all joist hangers basement
Erosion Control Inspection Residential Partial 7/29/2022 7/29/2022 07/29/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
07/29/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
All Rough Inspection - Residential Failed 9/20/2022 9/20/2022 09/20/2022
Misc
Corrective Action Required
07/29/2022
-seal all penetrations through air returns - See joist cavity penetrations -provide 3” SCH 40 steel column at garage steel beam per plans -2x10 joist split at pantry -provide all truss hangers per plans -1st floor breakfast -provide 1” clearance at b vent basement
Erosion Control Inspection Residential Partial 9/20/2022 9/20/2022 09/20/2022
Footing Inspection - Residential Passed 9/20/2022 9/20/2022 09/20/2022
Misc
Corrective Action Required
09/20/2022
APPROVED PER BRADLEY HUXOL 3/30/22
All Rough Inspection - Residential Failed 10/19/2022 10/19/2022 10/19/2022
Misc
Corrective Action Required
09/20/2022
- nail off truss hangers at 1st floor breakfast - fireblock rim joist opening to basement at added SCH 40 steel column at garage I beam
All Rough Inspection - Residential Passed 10/21/2022 10/21/2022 10/21/2022
Misc
Resolved
10/21/2022
Driveway Inspection Partial 12/1/2022 12/01/2022
Misc
Informational
12/01/2022
12-1-22 RH. Driveway is formed up and aggregate is placed and compacted. Contractor has blankets ready to use. Approved to pour.
Driveway Inspection Passed 12/8/2022 12/8/2022 12/08/2022
Misc
Informational
12/01/2022
12-1-22 RH. Driveway is formed up and aggregate is placed and compacted. Contractor has blankets ready to use. Approved to pour. 12-8-22 RH. Driveway meets LS and ADA specification.
Occupancy Inspection - Codes Residential Failed 3/8/2023 3/8/2023 03/08/2023
Occupancy Inspection - Codes Residential Failed 3/8/2023 03/08/2023
Misc
Corrective Action Required
03/08/2023
Basement handrail is not installed
Occupancy Inspection - Codes Residential Full C of O 3/13/2023 3/13/2023 03/13/2023
Misc
Resolved
03/13/2023
Documents & Images
Date Uploaded File Type Document Name
01/31/2022 MN #119 - PERMIT APP
02/02/2022 Permit Codes Residential Plan Review
02/03/2022 Approved Plans APPROVED DRAWINGS
02/03/2022 Approved Plans APPROVED TRUSS LAYOUT
02/03/2022 Approved Plans APPROVED TRUSS PACKAGE
02/07/2022 LOT 120 MBOE LETTER
02/07/2022 Permit Codes Residential Plan Review
02/09/2022 Plot Plan APPROVED PLOT PLAN
02/09/2022 Permit Codes Residential Plan Review
02/10/2022 Permit DS Building Permit
02/10/2022 Receipt Receipt for transaction:2022-000725
04/06/2022 119 Manor at Stoney Creek FTNG
05/04/2022 Letter INSPECTION SUMMARY
05/06/2022 Letter INSPECTION SUMMARY
05/09/2022 Letter INSPECTION SUMMARY
05/09/2022 Letter INSPECTION SUMMARY
07/29/2022 Letter INSPECTION SUMMARY
07/29/2022 Letter INSPECTION SUMMARY
07/29/2022 Letter INSPECTION SUMMARY
07/29/2022 Letter INSPECTION SUMMARY
08/09/2022 MN 119 Framing items letter
09/20/2022 Letter INSPECTION SUMMARY
09/20/2022 Letter INSPECTION SUMMARY
09/20/2022 Letter INSPECTION SUMMARY
10/19/2022 Letter INSPECTION SUMMARY
10/21/2022 Letter INSPECTION SUMMARY
12/01/2022 Letter INSPECTION SUMMARY
12/08/2022 Letter INSPECTION SUMMARY
03/08/2023 Letter INSPECTION SUMMARY
03/17/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home