Permit Application Status

PRRES20220011


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20220011
Building Permit - Residential
Certificate of Occupancy
JCM DEVELOPMENT LLC
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. UNCOVERED DECK.
01/03/2022
01/12/2022
07/05/2022
10/14/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
JCM DEVELOPMENT LLC, Address:1314 SW MARKET ST  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
JASONH@CLOVERANDHIVE.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 01/12/2022
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 01/12/2022
8331507-Sewer Connection Fee $450.00 $450.00 Paid 01/12/2022
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 01/12/2022
8350015-Water Meter Fee $479.24 $479.24 Paid 01/12/2022
9110078-Valuation Fee New Single Family $1,225.14 $1,225.14 Paid 01/12/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 07/25/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 07/25/2022
9110080-3rd and Subsequent Inspection Fee (Per Hour) $150.00 $150.00 Paid 07/25/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Failed 2/16/2022 2/16/2022 02/16/2022
Misc
Corrective Action Required
02/16/2022
WHERE BUILDING SEWER HAS CHANGE OF DIRECTION GREATER THAN 45 DEGREES A CLEANOUT SHALL BE INSTALLED AT THE CHANGE OF DIRECTION P3005.2.4
Erosion Control Inspection Residential Partial 2/16/2022 2/16/2022 02/16/2022
Misc
Corrective Action Required
02/16/2022
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
Footing Inspection - Residential Passed 2/16/2022 2/16/2022 02/16/2022
Misc
Informational
02/16/2022
APPROVED PER DAVID P AINSWORTH 1/24/22
Sewer Service Inspection - R Passed 2/28/2022 (9:45) 2/28/2022 02/28/2022
Underslab Plumbing Inspection - Residential Passed 3/1/2022 3/1/2022 03/01/2022
Misc
Resolved
03/01/2022
Water Service Inspection - R Passed 3/8/2022 (9:45) 3/8/2022 03/08/2022
Erosion Control Inspection Residential Failed 3/8/2022 3/8/2022 03/08/2022
Misc
Resolved
03/08/2022
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
03/08/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Electrical Service Inspection Passed 5/20/2022 5/20/2022 05/20/2022
Gas Service Inspection - Residential Passed 5/20/2022 5/20/2022 05/20/2022
All Rough Inspection - Residential Failed 5/20/2022 5/20/2022 05/20/2022
Misc
Corrective Action Required
05/20/2022
-fur down at garage ceiling to allow for R-19 insulation -provide bocca protection plate at furred down soffit DWV -sister in new stud for stud that has been overbored for plumbing at 1st floor bath exterior wall -12” oc nailing at all abutting and intersecting wall corners -provide structural straps at all top plates bored 50% or more all exterior walls and interior load bearing walls, strap must be min 1 1/2” wide, 16 gauge, extend 6” passed each side of bore and must have (4) 10D nails each side of strap -(5) 2x4 stud pack or 3” SCH 40 steel column at W12x30 per plans -ensure UFER at garage remains accessible at finish -protection plate at bottom plate DWV north garage wall must protect at the plate and 2” above plate -provide header and joist hangers at joist cut for HVAC/plumbing chase at great room/kitchen, joist currently supported by non load bearing wall -bottom chord of D1 gable truss in garage damaged -toenail all floor joists per code -address top plate to top plate lap corner connection as required by code at front entry wall -Fireblock all tub traps -address damaged A2 truss 2nd floor bedroom -address B4 dbl girder truss 2nd floor bored for electrical in (2) locations -protect all NM within 6’ of attic entry 2nd floor -fireblock unused floor bore 2nd floor hall closet -secure electrical per code, (3) NM electrical secured with staple together, more than (2) NM wires through same bore -address CS-PF portal bracing at master bed windows per plans, see plans/IRC R602.10.6.4 for reference, dbl 2x12 header with trimmer studs, king studs, tension straps, nail pattern exterior sheathing per design -tighten all anchor bolts -anchor bolts required within 12” of plate breaks basement -provide joist hangers at joist to dbl beam connection above basement stairs -solid block between joists at kitchen island per plans -solid shim 2x6 stud packs at basement steel beam to provide full bearing -address bores for NM in floor joist less than 2” apart basement above service panel
All Rough Inspection - Residential Failed 6/3/2022 6/3/2022 06/03/2022
Misc
Corrective Action Required
05/20/2022
-provide bocca protection plate at furred down soffit DWV 1st floor powder bath -provide structural straps at all top plates bored 50% or more all exterior walls and interior load bearing walls, strap must be min 1 1/2” wide, 16 gauge, extend 6” passed each side of bore and must have (4) 10D nails each side of strap - see garage wall -address B4 dbl girder truss 2nd floor bored for electrical in (2) locations (repair to be made with no 2 graded 2x4 per engineer report, not utility grade lumber used from concrete form) -address CS-PF portal bracing at master bed windows per plans, see plans/IRC R602.10.6.4 for reference, dbl 2x12 header with trimmer studs, king studs, tension straps, nail pattern exterior sheathing per design -solid shim 2x6 stud packs at basement steel beam to provide full bearing, all studs in pack
Erosion Control Inspection Residential Partial 06/03/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
06/03/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
All Rough Inspection - Residential Failed 6/8/2022 6/8/2022 06/08/2022
Misc
Corrective Action Required
06/03/2022
-provide structural straps at all top plates bored 50% or more all exterior walls and interior load bearing walls, strap must be min 1 1/2” wide, 16 gauge, extend 6” passed each side of bore and must have (4) 10D nails each side of strap - see garage wall (NOT DONE) -address CS-PF portal bracing at master bed windows per plans, see plans/IRC R602.10.6.4 for reference, dbl 2x12 header with trimmer studs, king studs, plates, tension straps, nail pattern exterior sheathing per design (NOT DONE, SEE DETAIL S2.0 IN PLANS)
All Rough Inspection - Residential Failed 6/9/2022 6/9/2022 06/09/2022
Misc
Corrective Action Required
06/08/2022
-address CS-PF portal bracing at master bed windows per plans, see plans/IRC R602.10.6.4 for reference, dbl 2x12 header with trimmer studs, king studs, plates, tension straps, nail pattern exterior sheathing per design (NOT DONE, SEE DETAIL S2.0 IN PLANS)
All Rough Inspection - Residential Not Ready 6/10/2022 6/10/2022 06/10/2022
Misc
Corrective Action Required
06/09/2022
-address CS-PF portal bracing at master bed windows per plans, see plans/IRC R602.10.6.4 for reference, dbl 2x12 header with trimmer studs, king studs, plates, tension straps, nail pattern exterior sheathing per design (NOT DONE, SEE DETAIL S2.0 IN PLANS)
All Rough Inspection - Residential Not Ready 6/13/2022 6/13/2022 06/13/2022
Misc
Corrective Action Required
06/10/2022
-address CS-PF portal bracing at master bed windows per plans, see plans/IRC R602.10.6.4 for reference, dbl 2x12 header with trimmer studs, king studs, plates, tension straps, nail pattern exterior sheathing per design (NOT DONE, SEE DETAIL S2.0 IN PLANS)
All Rough Inspection - Residential Passed 6/15/2022 6/15/2022 06/15/2022
Misc
Resolved
06/15/2022
Erosion Control Inspection Residential Partial 6/15/2022 06/15/2022
Driveway Inspection Partial 7/21/2022 07/21/2022
Misc
Informational
07/21/2022
7-21-22 RH. Driveway was formed up and aggregate was placed and compacted.
Driveway Inspection Passed 8/15/2022 8/15/2022 08/15/2022
Misc
Informational
07/21/2022
7-21-22 RH. Driveway was formed up and aggregate was placed and compacted. 8-15-22 RH. Driveway was poured and follows LS and ADA specification.
Piers/Caissons Inspection - Residential Failed 8/19/2022 (8:45) 8/19/2022 08/19/2022
Misc
Corrective Action Required
08/19/2022
(2) 18" x 36" PIERS PER PLANS
Piers/Caissons Inspection - Residential Passed 8/19/2022 8/19/2022 08/19/2022
Misc
Resolved
08/19/2022
(2) 18" x 36" PIERS PER PLANS
Plot Plan Inspection Passed 8/30/2022 08/30/2022
Occupancy Inspection - Codes Residential Failed 9/22/2022 9/22/2022 09/22/2022
Misc
Corrective Action Required
09/22/2022
-tape/mud garage ceiling at garage door bracket penetrations -mark bedroom breaker locations at service panel -provide mid rail support at basement stairs handrail -tempered glass at 2nd floor stairs next to handrail and landing windows -uncover water meter lid -nail off joist hangers at deck -seal all penetrations in siding, seal across top of AC disconnect and meter can -downspouts and sump pump min 36” discharge from foundation
Erosion Control Inspection Residential Passed 10/14/2022 10/14/2022 10/14/2022
Occupancy Inspection - Codes Residential Full C of O 10/14/2022 10/14/2022 10/14/2022
Misc
Resolved
10/14/2022
Documents & Images
Date Uploaded File Type Document Name
01/03/2022 CB #154 - PERMIT APPLICATION
01/03/2022 LOT 154 FINAL
01/05/2022 Approved Plans APPROVED DRAWINGS
01/05/2022 Approved Plans APPROVED TRUSS PACKAGE
01/05/2022 Approved Plans APPROVED TRUSS LAYOUT
01/06/2022 Permit Codes Residential Plan Review
01/12/2022 Plot Plan APPROVED PLOT PLAN
01/12/2022 Permit Codes Residential Plan Review
01/12/2022 Permit DS Building Permit
01/12/2022 Receipt Receipt for transaction:2022-000219
01/25/2022 M L Crose 3542 SE Corbin Dr LSMO Cobey Creek Lot 154 Clayton Permit 2022-0011 Footing Inspection Report 1-24-22
02/16/2022 Letter INSPECTION SUMMARY
02/16/2022 Letter INSPECTION SUMMARY
02/16/2022 Letter INSPECTION SUMMARY
02/28/2022 Letter INSPECTION SUMMARY
03/01/2022 Letter INSPECTION SUMMARY
03/01/2022 Letter INSPECTION SUMMARY
03/08/2022 Letter INSPECTION SUMMARY
03/08/2022 Letter INSPECTION SUMMARY
05/20/2022 Letter INSPECTION SUMMARY
05/20/2022 Letter INSPECTION SUMMARY
05/20/2022 Letter INSPECTION SUMMARY
05/23/2022 Approved Plans APPROVED TRUSS LETTER
05/26/2022 154 Cobey Creek Letter#3
05/26/2022 154 Cobey Creek Letter#2
06/02/2022 Approved Plans APPROVED TRUSS LETTER
06/02/2022 Approved Plans APPROVED TRUSS LETTER
06/03/2022 Letter INSPECTION SUMMARY
06/03/2022 Letter INSPECTION SUMMARY
06/08/2022 Letter INSPECTION SUMMARY
06/09/2022 Letter INSPECTION SUMMARY
06/10/2022 Letter INSPECTION SUMMARY
06/15/2022 Letter INSPECTION SUMMARY
06/15/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
07/25/2022 Receipt Receipt for transaction:2022-006043
08/15/2022 Letter INSPECTION SUMMARY
08/19/2022 Letter INSPECTION SUMMARY
08/19/2022 Letter INSPECTION SUMMARY
08/29/2022 Plot Plan APPROVED AS BUILT PLOT PLAN
08/30/2022 Letter INSPECTION SUMMARY
09/22/2022 Letter INSPECTION SUMMARY
10/14/2022 Letter INSPECTION SUMMARY
10/14/2022 Letter Field Certificate of Occupancy
10/14/2022 Letter Codes Final Certificate of Occupancy
08/02/2023 23-0802 - CB #154 - Basswood - Farmhouse ELEV 3 - Basement Finish
08/02/2023 CB #154 - Basement Finish - Scope of Work
08/02/2023 23-0802 - CB #154 - Basswood - Farmhouse ELEV 3 - Basement Finish
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home