Permit Application Status

PRRES20216145


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20216145
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK
11/29/2021
12/08/2021
06/05/2022
12/30/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CMH PARKS INC, Address:5000 CLAYTON RD  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
KYLEP@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,003.38 $1,003.38 Paid 12/08/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 12/08/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 12/08/2021
8331504-EFHB Middle Big Creek, Full $435.24 $435.24 Paid 12/08/2021
8331507-Sewer Connection Fee $390.00 $390.00 Paid 12/08/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 12/08/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 12/08/2021
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 12/14/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 1/3/2022 1/3/2022 01/03/2022
Misc
Informational
01/03/2022
APPROVED PER BRADLEX HUXOL 12/29/21
Underslab Plumbing Inspection - Residential Passed 2/1/2022 2/1/2022 02/01/2022
Water Service Inspection - R Passed 2/7/2022 (11:00) 2/7/2022 02/07/2022
Gas Service Inspection - Residential Passed 7/13/2022 7/13/2022 07/13/2022
Electrical Service Inspection Failed 7/13/2022 7/13/2022 07/13/2022
Misc
Corrective Action Required
07/13/2022
Add #4 jumper from Grounding bus to neutral bus or move UFER ground to neutral bus
All Rough Inspection - Residential Failed 7/13/2022 7/13/2022 07/13/2022
Miscellaneous Correction
Corrective Action Required
07/13/2022
complete PFH portal frame nail pattern Nail exterior corner to plan, single bay garage back Tighten anchor bolts in garage Protect wiring 6’ from attic access Fire block nm penetration pantry top and bottom Nail CSPF above sliding door at dining room E3901.1 Add electrical floor outlet near stairs at great room Fire block penetration nm top plate bedroom 1 entry Fire block penetration nm floor bedroom 1 and bathroom Fire block floor penetration nm at entry to great room Fire block SEC bedroom 2 at floor Entry wall not tied at top plate , strap both sides Fire block vertical exterior wall by wall bar Support soffit in basement wider than 4’ to code Anchor deck ledger to house to code Complete window frame and flashing
Electrical Service Inspection Passed 7/15/2022 7/15/2022 07/15/2022
Misc
Resolved
07/15/2022
All Rough Inspection - Residential Passed 7/15/2022 7/15/2022 07/15/2022
Miscellaneous Correction
Resolved
07/15/2022
Driveway Inspection Partial 8/9/2022 8/9/2022 08/09/2022
Misc
Informational
08/09/2022
8.9.2022 I performed a driveway inspection and pass the sub-grade to pour concrete.
Sidewalk Inspection Partial 8/9/2022 8/9/2022 08/09/2022
Misc
Informational
08/09/2022
8.9.2022 I conducted a sidewalk inspection and pass the subgrade to pour concrete
Driveway Inspection Passed 8/16/2022 (1:00) 8/16/2022 08/25/2022
Misc
Informational
08/09/2022
8.9.2022 I performed a driveway inspection and pass the sub-grade to pour concrete. 8/19/2022 Driveway appears to be compliant
Sidewalk Inspection Passed 8/16/2022 (1:00) 8/16/2022 08/25/2022
Misc
Informational
08/09/2022
8.9.2022 I conducted a sidewalk inspection and pass the subgrade to pour concrete 8/19/2022 Sidewalk appears to be compliant
Sewer Service Inspection - R Passed 2/4/2022 2/4/2022 11/08/2022
Erosion Control Inspection Residential Passed 11/8/2022 11/8/2022 11/08/2022
Plot Plan Inspection Passed 11/8/2022 11/8/2022 11/08/2022
Occupancy Inspection - Codes Residential Failed 11/8/2022 11/8/2022 11/08/2022
Misc
Corrective Action Required
11/08/2022
-GFCI PROTECTION REQUIRED ON DISHWASHER OUTLET -PROVIDE SPARK RINGS OR ADJUST OUTLET BOXES AT KITCHEN, NO MORE THAN 1/4" BOX SETBACK WITH A NON COMBUSTIBLE SURFACE, NO SETBACK ALLOWED WITH A COMBUSTIBLE SURFACE -TAMPER RESISTANT ELECTRICAL RECEPTACLES REQUIRED PER IRC E4002.14, NEC 406.12(A) -PROVIDE GFCI PROTECTED OUTLET AT BASEMENT HVAC MECH ROOM -PROVIDE DEDICATED OUTLET OR GFCI PROTECTION ON SUMP PUMP AND SERVICE PANEL OUTLETS AT UNFINISHED BASEMENT MECH ROOM, IF PROVIDING DEDICATED RECEPTACLES MARK AS NOT GFCI PROTECTED -PROVIDE BREAKER LOCKOUT FOR HOT WATER HEATER AND ANY HARDWIRED APPLIANCES -AFCI ARC FAULT PROTECTION REQUIRED AT ALL CIRCUIT LOCATIONS PER IRC E3902.16, NEC 210.12(A) -PROVIDE OUTLET WITHIN 25' OF AC AT EXTERIOR -PROVIDE (2) 1/2" THROUGH BOLTS AT EACH POST/BEAM CONNECTION DECK -PROVIDE ANGLE CLIP HANGERS AT DECK BEAM -SUMP PUMP DISCHARGE MIN 36" FROM FOUNDATION
Occupancy Inspection - Codes Residential Failed 12/1/2022 12/1/2022 12/01/2022
Misc
Corrective Action Required
11/08/2022
-TAMPER RESISTANT ELECTRICAL RECEPTACLES REQUIRED PER IRC E4002.14, NEC 406.12(A) -PROVIDE GFCI PROTECTED OUTLET AT BASEMENT HVAC MECH ROOM (no current at outlet for test) -PROVIDE EITHER DEDICATED OUTLETS OR GFCI PROTECTION ON SUMP PUMP AND SERVICE PANEL OUTLETS AT UNFINISHED BASEMENT, IF PROVIDING DEDICATED RECEPTACLES MARK AS NOT GFCI PROTECTED -AFCI ARC FAULT PROTECTION REQUIRED AT ALL CIRCUIT LOCATIONS PER IRC E3902.16, NEC 210.12(A) -PROVIDE OUTLET WITHIN 25' OF AC AT EXTERIOR (no current at outlet for test) -PROVIDE HANGERS AND DECK BEAM CONNECTION TO LEDGER PER THE PLANS, SIMPSON HUCQ210-2-SDS WITH SIMPSON SCREWS, SEE DETAIL A3.0 IN PLANS
Occupancy Inspection - Codes Residential Not Ready 12/12/2022 12/12/2022 12/12/2022
Misc
Corrective Action Required
12/01/2022
-complete all corrections before scheduling, fee added -TAMPER RESISTANT ELECTRICAL RECEPTACLES REQUIRED PER IRC E4002.14, NEC 406.12(A) -AFCI ARC FAULT PROTECTION REQUIRED AT ALL CIRCUIT LOCATIONS PER IRC E3902.16, NEC 210.12(A) -(not complete see fridge, bar Rec, kitchen, cooktop/hood, micro, washer circuits) -PROVIDE HANGERS AND DECK BEAM CONNECTION TO LEDGER PER THE PLANS, SIMPSON HUCQ210-2-SDS WITH SIMPSON SCREWS, SEE DETAIL A3.0 IN PLANS (not complete)
Occupancy Inspection - Codes Residential Full C of O 12/30/2022 12/30/2022 12/30/2022
Misc
Resolved
12/30/2022
Documents & Images
Date Uploaded File Type Document Name
11/29/2021 MN #112 - PERMIT APP
12/07/2021 Approved Plans Approved Drawings
12/07/2021 Approved Plans Approved Truss Layout
12/07/2021 Approved Plans Approved Truss Pacakge
12/07/2021 Permit Codes Residential Plan Review
12/08/2021 Plot Plan Approved Plot Plan
12/08/2021 Permit Codes Residential Plan Review
12/08/2021 Permit DS Building Permit
12/08/2021 Receipt Receipt for transaction:2021-009181
12/30/2021 112 Manor at Stoney Creek-FTNG
01/03/2022 Letter INSPECTION SUMMARY
02/01/2022 Letter INSPECTION SUMMARY
02/04/2022 Letter INSPECTION SUMMARY
02/07/2022 Letter INSPECTION SUMMARY
07/13/2022 Letter INSPECTION SUMMARY
07/13/2022 Letter INSPECTION SUMMARY
07/13/2022 Letter INSPECTION SUMMARY
07/15/2022 Letter INSPECTION SUMMARY
07/15/2022 Letter INSPECTION SUMMARY
08/09/2022 Letter INSPECTION SUMMARY
08/09/2022 Letter INSPECTION SUMMARY
08/25/2022 Letter INSPECTION SUMMARY
08/25/2022 Letter INSPECTION SUMMARY
08/25/2022 Letter INSPECTION SUMMARY
11/08/2022 Letter INSPECTION SUMMARY
11/08/2022 Letter INSPECTION SUMMARY
11/08/2022 Letter INSPECTION SUMMARY
11/08/2022 Letter INSPECTION SUMMARY
12/01/2022 Letter INSPECTION SUMMARY
12/12/2022 Letter INSPECTION SUMMARY
12/14/2022 Receipt Receipt for transaction:2022-009498
12/30/2022 Letter Field Certificate of Occupancy
12/30/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents