Permit Application Status

PRRES20216118


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20216118
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK
11/29/2021
12/07/2021
05/29/2022
04/24/2023
Locations
Contacts
ASPEN HOME BUILDERS LLC, Address:6618 ROYAL ST #B, Phone:(816) 507-0123  
Trevor Wiest, Address:6618 Royal St Suite B , Phone:(816) 728-9115  
MCDANIEL FURNACE & SHEET METAL, Address:2905 S M 291 FRONTAGE RD, Phone:(816) 373-6370  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
N & E Plumbing LLC, Address:17301 Jennifer St.  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,478.39 $1,478.39 Paid 12/07/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 12/07/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 12/07/2021
8331507-Sewer Connection Fee $570.00 $570.00 Paid 12/07/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 12/07/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 12/07/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 12/17/2021 12/17/2021
Underslab Plumbing Inspection - Residential Passed 1/26/2022 1/26/2022 01/26/2022
All Rough Inspection - Residential Failed 4/15/2022 4/15/2022 04/15/2022
Miscellaneous Correction
Informational
04/15/2022
-Portal frame pass This inspection to be done at all rough. Not ready for rough inspection
Sewer Service Inspection - R Passed 5/20/2022 (9:00) 5/20/2022 05/20/2022
Water Service Inspection - R Partial 5/20/2022 05/20/2022
Misc
Informational
05/20/2022
Pex ran roughly 20’ from foundation
Water Service Inspection - R Passed 5/23/2022 (9:30) 5/23/2022 05/23/2022
Misc
Resolved
05/23/2022
Pex ran roughly 20’ from foundation
All Rough Inspection - Residential Failed 6/22/2022 6/22/2022 06/22/2022
Miscellaneous Correction
Informational
04/15/2022
-Portal frame pass This inspection to be done at all rough. Not ready for rough inspection
Miscellaneous Correction
Corrective Action Required
06/22/2022
- Nail off all LIB’s through out - Complete vent in garage - Provide hangers on doubles at cat walk - Nail cspf and add straps in master bedroom - Strap top plate master closet - Open front porch covering for inspection - Add stud under LVL bedroom 4 exterior wall - Strap DWV 2” and under second floor - Provide window bedroom 2 - Fire block penetration bedroom 4 top plate
Electrical Service Inspection Passed 6/22/2022 6/22/2022 06/22/2022
Gas Service Inspection - Residential Passed 6/22/2022 6/22/2022 06/22/2022
Driveway Inspection Partial 10/13/2022 10/13/2022 10/13/2022
Misc
Informational
10/13/2022
10-13-22 RH. Driveway is formed up and aggregate was added and compacted.
Driveway Inspection Passed 10/20/2022 10/20/2022 10/20/2022
Misc
Informational
10/13/2022
10-13-22 RH. Driveway is formed up and aggregate was added and compacted. 10-20-22 RH. Driveway meets LS and ADA specification.
All Rough Inspection - Residential Failed 6/28/2022 11/21/2022 11/21/2022
Erosion Control Inspection Residential Failed 2/22/2023 02/22/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
02/22/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/22/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
All Rough Inspection - Residential Passed 3/20/2023 3/20/2023 03/20/2023
Miscellaneous Correction
Resolved
03/20/2023
Miscellaneous Correction
Resolved
03/20/2023
Occupancy Inspection - Codes Residential Failed 3/20/2023 3/20/2023 03/20/2023
Misc
Corrective Action Required
03/20/2023
-Address water meter height at final grade -Locate/mark sewer line -Secure A/C whip within 12 inches of disconnect box -Missing egress ladder -Address width of handrail in garage -Label non-GFCI's in garage -Adjust self closing hinges at garage door -Missing safety locks at East and North bedroom windows on second floor -Missing anchor bolts at post in basement -Missing sod -Missing splash blocks
Plot Plan Inspection Passed 3/20/2023 03/20/2023
Occupancy Inspection - Codes Residential Failed 3/20/2023 03/20/2023
Misc
Corrective Action Required
03/20/2023
-Address water meter height at final grade -Locate/mark sewer line -Secure A/C whip within 12 inches of disconnect box -Missing egress ladder -Address width of handrail in garage -Label non-GFCI's in garage -Adjust self closing hinges at garage door -Missing safety locks at East and North bedroom windows on second floor -Missing anchor bolts at post in basement -Missing sod -Missing splash blocks -Address pending pier inspection
Occupancy Inspection - Codes Residential Failed 3/22/2023 3/22/2023 03/22/2023
Misc
Corrective Action Required
03/20/2023
-Address water meter height at final grade -Locate/mark sewer line -Secure A/C whip within 12 inches of disconnect box -Missing anchor bolts at post in basement -Missing sod -Missing splash blocks -Address pending pier inspection
Piers/Caissons Inspection - Residential Passed 4/4/2023 04/04/2023
Occupancy Inspection - Codes Residential Failed 4/4/2023 4/4/2023 04/04/2023
Misc
Corrective Action Required
03/22/2023
-sod -splash blocks and sump pump discharge to extend 36” from foundation
Erosion Control Inspection Residential Passed 04/24/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
04/24/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM2 ESC DEFICIENT INSTALLATION
Resolved
04/24/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Occupancy Inspection - Codes Residential Full C of O 4/24/2023 4/24/2023 04/24/2023
Misc
Resolved
04/24/2023
-sod -splash blocks and sump pump discharge to extend 36” from foundation
Documents & Images
Date Uploaded File Type Document Name
11/29/2021 Tax Application 3
11/29/2021 Tax Application 4
11/29/2021 Tax Application 2
11/29/2021 Permit App Cont
11/29/2021 HF 45 Permit App
11/29/2021 HF 45 Tax Application
11/30/2021 Plot Plan Approved Plot Plan
11/30/2021 Permit Codes Residential Plan Review
12/07/2021 Approved Plans Approved Drawings
12/07/2021 Permit Codes Residential Plan Review
12/07/2021 Permit DS Building Permit
12/07/2021 Receipt Receipt for transaction:2021-009156
12/17/2021 Letter INSPECTION SUMMARY
01/26/2022 Letter INSPECTION SUMMARY
01/26/2022 Letter INSPECTION SUMMARY
04/15/2022 Letter INSPECTION SUMMARY
05/20/2022 Letter INSPECTION SUMMARY
05/20/2022 Letter INSPECTION SUMMARY
05/23/2022 Letter INSPECTION SUMMARY
06/22/2022 Letter INSPECTION SUMMARY
06/22/2022 Letter INSPECTION SUMMARY
06/22/2022 Letter INSPECTION SUMMARY
06/28/2022 Letter INSPECTION SUMMARY
10/13/2022 Letter INSPECTION SUMMARY
10/20/2022 Letter INSPECTION SUMMARY
02/22/2023 Letter INSPECTION SUMMARY
02/22/2023 Letter INSPECTION SUMMARY
03/20/2023 Letter INSPECTION SUMMARY
03/20/2023 Letter INSPECTION SUMMARY
03/20/2023 Letter INSPECTION SUMMARY
03/20/2023 Letter INSPECTION SUMMARY
03/22/2023 Letter INSPECTION SUMMARY
03/28/2023 Hook Farms, Lot 45 - deck piers & porch
04/04/2023 Letter INSPECTION SUMMARY
04/04/2023 Letter INSPECTION SUMMARY
04/24/2023 Letter INSPECTION SUMMARY
04/24/2023 Letter Field Certificate of Occupancy
04/24/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home