Summary
PRRES20216112
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED PATIO STOP WORK ORDER generated on 01/14/2022 12:00 AM by username 'Patrick Schonfeldt'. STOP WORK ORDER removed on 01/19/2022 12:00 AM by username 'Patrick Schonfeldt'.
11/29/2021
11/30/2021
05/29/2022
12/01/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CMH PARKS INC, Address:5000 CLAYTON RD  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
KYLEP@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,346.86 $1,346.86 Paid 11/30/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 11/30/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 11/30/2021
8331504-EFHB Middle Big Creek, Full $569.16 $569.16 Paid 11/30/2021
8331507-Sewer Connection Fee $510.00 $510.00 Paid 11/30/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 11/30/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 11/30/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 11/11/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Not Ready 1/14/2022 1/14/2022 01/14/2022
Misc
Corrective Action Required
01/14/2022
INSPECTION DENIED FOOTING POURED WITHOUT INSPECTION
Footing Inspection - Residential Failed - Stop Work 1/14/2022 1/14/2022 01/14/2022
Misc
Corrective Action Required
01/14/2022
FOOTING POURED WITHOUT INSPECTION, ENGINEER REPORT REQUIRED TO BE UPLOADED TO PERMIT WITHIN 48 HOURS OF INSPECTION
Footing Inspection - Residential Passed 1/19/2022 1/19/2022 01/19/2022
Misc
Informational
01/19/2022
APPROVED PER BRADLEY HUXOL 12/9/21
Underslab Plumbing Inspection - Residential Passed 1/26/2022 1/26/2022 01/26/2022
Misc
Resolved
01/26/2022
INSPECTION DENIED FOOTING POURED WITHOUT INSPECTION
Erosion Control Inspection Residential Partial 1/26/2022 1/26/2022 01/26/2022
Misc
Corrective Action Required
01/26/2022
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
Sewer Service Inspection - R Passed 2/9/2022 (1:00) 2/9/2022 02/09/2022
Water Service Inspection - R Partial 2/9/2022 2/9/2022 02/09/2022
Water Service Inspection - R Passed 2/10/2022 (8:45) 2/10/2022 02/10/2022
Erosion Control Inspection Residential Failed 2/10/2022 2/10/2022 02/10/2022
Misc
Resolved
02/10/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
02/10/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Electrical Service Inspection Passed 6/22/2022 6/22/2022 06/22/2022
Gas Service Inspection - Residential Passed 6/22/2022 6/22/2022 06/22/2022
All Rough Inspection - Residential Failed 6/22/2022 6/22/2022 06/22/2022
Misc
Corrective Action Required
06/22/2022
-garage PFH, nail edges of sheathing to blocking at sheathing break portal leg 3” oc -nail all exterior sheathing per plans -provide structural straps all top plates bores 50% or more all exterior walls and interior load bearing walls, straps min 1 1/2” wide, 16 ga, must extend 6” each side passed opening with (4) 10D nails each side of strap -address floor joist cut for HVAC chase at pantry, floor joist currently supported by non load bearing wall -fireblock HVAC chase pantry -support all DWV 48” oc, traps not considered support -fireblock fireplace at top plate -seal top plate penetrations at great room -secure all vertical DWV 2” or less at mi point -fireblock between dbl wall top plate, 1st floor bath -install front door -provide 30” vertical clearance at 2nd floor attic access -provide all truss hangers per plans -provide H2.5 truss hold downs at trpl girder master bed -nail all dbl and trpl girder trusses together per plans -(2) 2x10 header basement egress window per plans
All Rough Inspection - Residential Failed 6/24/2022 6/24/2022 06/24/2022
Misc
Corrective Action Required
06/22/2022
-provide structural straps all top plates bores 50% or more all exterior walls and interior load bearing walls, straps min 1 1/2” wide, 16 ga, must extend 6” each side passed opening with (4) 10D nails each side of strap ** incomplete -fireblock between dbl wall top plate, 1st floor bath **incomplete. -provide 30” vertical clearance at 2nd floor attic access , now cut the roof shetathing back for acces to the main attic. -provide H2.5 truss hold downs at trpl girder master bed , **incomplete
All Rough Inspection - Residential Passed 7/13/2022 7/13/2022 07/13/2022
Misc
Resolved
07/13/2022
-provide structural straps all top plates bores 50% or more all exterior walls and interior load bearing walls, straps min 1 1/2” wide, 16 ga, must extend 6” each side passed opening with (4) 10D nails each side of strap ** incomplete -provide 30” vertical clearance at 2nd floor attic access , now cut the roof shetathing back for acces to the main a -provide H2.5 truss hold downs at trpl girder master bed , **incomplete
Driveway Inspection Partial 8/3/2022 8/3/2022 08/03/2022
Misc
Informational
08/03/2022
8.3.2022 I performed a driveway inspection and pass the sub-grade to pour concrete.
Sidewalk Inspection Partial 8/3/2022 8/3/2022 08/03/2022
Misc
Informational
08/03/2022
8.3.2022 I performed a sidewalk inspection and pass the sub-grade to pour concrete.
Driveway Inspection Passed 08/05/2022
Misc
Informational
08/03/2022
8.3.2022 I performed a driveway inspection and pass the sub-grade to pour concrete. 8.5.2022 Driveway appears to be compliant
Sidewalk Inspection Passed 08/05/2022
Misc
Informational
08/05/2022
8.5.2022 Sidewalk appears to be compliant
Occupancy Inspection - Codes Residential Failed 11/10/2022 11/10/2022 11/10/2022
Misc
Corrective Action Required
11/10/2022
-resolve outstanding inspection fees -submit as graded plot plan for review and approval -provide guardrail at front porch , measured 30” from grade 36” out on horizontal plane -trim attic access opening garage -3/8” max variance between riser heights at garage stairs -handrail to 2nd floor landing stairs must terminate above top rise of flight -provide pressure regulator at main water line -mark all breaker locations at sub panel -secure smoke to base at basement
Plot Plan Inspection Passed 11/16/2022 11/16/2022
Erosion Control Inspection Residential Passed 11/23/2022 11/23/2022 11/23/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
11/23/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Occupancy Inspection - Codes Residential Failed 11/23/2022 11/23/2022 11/23/2022
Misc
Corrective Action Required
11/10/2022
-provide guardrail at front porch , measured 30” from grade 36” out on horizontal plane
Occupancy Inspection - Codes Residential Full C of O 12/1/2022 12/1/2022 12/01/2022
Misc
Resolved
12/01/2022
Documents & Images
Date Uploaded File Type Document Name
11/29/2021 MN #120 - PERMIT APPLICATION
11/29/2021 120 MANOR AT STONEY CREEK TRUSS LAYOUT
11/29/2021 Approved Plans Approved Drawings
11/29/2021 Approved Plans Approved Truss Pacakge
11/30/2021 Permit Codes Residential Plan Review
11/30/2021 Approved Plans Approved Truss Layout
11/30/2021 LOT 120 MBOE LETTER
11/30/2021 Plot Plan Approved Plot Plan
11/30/2021 Permit Codes Residential Plan Review
11/30/2021 Permit DS Building Permit
11/30/2021 Receipt Receipt for transaction:2021-008986
01/14/2022 Letter INSPECTION SUMMARY
01/14/2022 Letter Stop Work Order
01/14/2022 120 Manor at Stoney Creek FTNG
01/19/2022 Letter INSPECTION SUMMARY
01/26/2022 Letter INSPECTION SUMMARY
01/26/2022 Letter INSPECTION SUMMARY
02/09/2022 Letter INSPECTION SUMMARY
02/09/2022 Letter INSPECTION SUMMARY
02/10/2022 Letter INSPECTION SUMMARY
02/10/2022 Letter INSPECTION SUMMARY
06/22/2022 Letter INSPECTION SUMMARY
06/22/2022 Letter INSPECTION SUMMARY
06/22/2022 Letter INSPECTION SUMMARY
06/24/2022 Letter INSPECTION SUMMARY
07/13/2022 Letter INSPECTION SUMMARY
08/03/2022 Letter INSPECTION SUMMARY
08/03/2022 Letter INSPECTION SUMMARY
11/10/2022 Letter INSPECTION SUMMARY
11/11/2022 Receipt Receipt for transaction:2022-008870
11/15/2022 Plot Plan Approved As-Graded Plot Plan
11/16/2022 Letter INSPECTION SUMMARY
11/23/2022 Letter INSPECTION SUMMARY
11/23/2022 Letter INSPECTION SUMMARY
12/01/2022 Letter Field Certificate of Occupancy
12/01/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home