Permit Application Status

PRRES20215840


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20215840
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK
11/08/2021
11/09/2021
09/13/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CMH PARKS INC, Address:5000 CLAYTON RD  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
AJ@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,096.25 $1,096.25 Paid 11/09/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 11/09/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 11/09/2021
8331504-EFHB Middle Big Creek, Full $468.72 $468.72 Paid 11/09/2021
8331507-Sewer Connection Fee $420.00 $420.00 Paid 11/09/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 11/09/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 11/09/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 09/12/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 1/6/2022 1/6/2022 01/06/2022
Misc
Informational
01/06/2022
APPROVED PER BADLEY HUXOL 12/3/21
Underslab Plumbing Inspection - Residential Passed 1/6/2022 1/6/2022 01/06/2022
Sewer Service Inspection - R Partial 1/26/2022 1/26/2022 01/26/2022
Misc
Informational
01/26/2022
PARTIAL ON APPROX 20' SEWER LINE FROM HOUSE ENTRY AT REAR TOWARDS MAIN RESCHEDULE INSPECTION WHEN REMAINDER COMPLETE
Sewer Service Inspection - R Passed 1/26/2022 1/26/2022 01/26/2022
Misc
Resolved
01/26/2022
PARTIAL ON APPROX 20' SEWER LINE FROM HOUSE ENTRY AT REAR TOWARDS MAIN RESCHEDULE INSPECTION WHEN REMAINDER COMPLETE
Water Service Inspection - R Partial 1/26/2022 1/26/2022 01/26/2022
Water Service Inspection - R Passed 1/27/2022 (10:30) 1/27/2022 01/27/2022
Erosion Control Inspection Residential Failed 3/8/2022 3/8/2022 03/08/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/08/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. ADDRESS EROSION CONTROL ON LOT GRAVEL FILTER REQUIRED, MIN 6" LIFT 3/4" GRAVEL CLEAN ALL MUD FROM STREET
Electrical Service Inspection Failed 5/25/2022 05/25/2022
Misc
Corrective Action Required
05/25/2022
-UFER ground required
Gas Service Inspection - Residential Failed 5/25/2022 05/25/2022
Misc
Corrective Action Required
05/25/2022
-Gas 7 psi, must maintain 10 psi for test, bond
All Rough Inspection - Residential Failed 5/25/2022 5/25/2022 05/25/2022
Misc
Corrective Action Required
05/25/2022
-seal all top plate penetrations garage -fur out at garage wall for gas line -provide 30” vertical clearance attic access -install front door -address top plate to top plate lap connection as required by code at front entry wall -min 24” lap between breaks at dbl top plate - see master bed -solid block along sheathing break master bedroom -address top plate to top plate corner lap connection at great room exterior wall, different wall heights -provide H2.5 truss hold downs at both plies of dbl girder truss at kitchen -only (2) NM wires at bores, (2) NM wires stapled together at insulated walls -provide H2.5 truss hold down front bedroom closet -CS-PF portal bracing at dining room windows per plans, see design/IRC R602.10.6.4, (2) 2x12 header per plans -provide all truss hangers per plans -provide all truss lateral bracing per plans -provide engineer report from truss manufacturer on damaged J14 trusses at master bathroom -install basement door -seal all top plate penetrations basement den -install and secure HVAC duct at basement bed closet -complete plumbing above tub basement bath -shield service panel from DWV above at basement mech room -provide additional studs for full bearing of stud pack above at west basement wall mech room per plans -nail all exterior sheathing together per plans -UFER ground required -Gas 7 psi, must maintain 10 psi for test
Erosion Control Inspection Residential Partial 05/25/2022
DCM2 ESC DEFICIENT INSTALLATION
Resolved
05/25/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. ADDRESS EROSION CONTROL ON LOT GRAVEL FILTER REQUIRED, MIN 6" LIFT 3/4" GRAVEL CLEAN ALL MUD FROM STREET
All Rough Inspection - Residential Failed 6/6/2022 6/6/2022 06/06/2022
Misc
Corrective Action Required
05/25/2022
-install front door -provide H2.5 truss hold down front bedroom closet (nail clip to truss) -CS-PF portal bracing at dining room windows per plans, see design/IRC R602.10.6.4, (2) 2x12 header per plans -provide engineer report from truss manufacturer on damaged J14 trusses at master bathroom -install basement door -shield service panel from DWV above at basement mech room -provide additional studs for full bearing of stud pack above at west basement wall mech room per plans -Gas 4 psi, must maintain 10 psi for test
Electrical Service Inspection Passed 6/6/2022 6/6/2022 06/06/2022
Misc
Resolved
06/06/2022
-UFER ground required
Gas Service Inspection - Residential Failed 6/6/2022 6/6/2022 06/06/2022
Misc
Corrective Action Required
05/25/2022
-Gas 4 psi, must maintain 10 psi for test, bond
Erosion Control Inspection Residential Failed 6/6/2022 6/6/2022 06/06/2022
Misc
Corrective Action Required
06/06/2022
maintain gravel filter on drive
Gas Service Inspection - Residential Not Ready 6/13/2022 6/13/2022 06/13/2022
Misc
Corrective Action Required
06/06/2022
-GAS LINE BOND REQUIRED
All Rough Inspection - Residential Passed 6/15/2022 6/15/2022 06/15/2022
Misc
Resolved
06/15/2022
Gas Service Inspection - Residential Passed 6/15/2022 6/15/2022 06/15/2022
Misc
Resolved
06/15/2022
-GAS LINE BOND REQUIRED
Erosion Control Inspection Residential Partial 6/15/2022 6/15/2022 06/15/2022
Misc
Resolved
06/15/2022
maintain gravel filter on drive
Driveway Inspection Partial 7/18/2022 7/18/2022 07/18/2022
Misc
Informational
07/18/2022
7-18-22 RH. Forms were up and currently meet ADA and LS specification. Aggregate was place and compacted. Crew is pouring today.
Sidewalk Inspection Partial 7/18/2022 7/18/2022 07/18/2022
Misc
Informational
07/18/2022
7-18-22 RH. Forms were up and currently meet ADA and LS specification. Aggregate was place and compacted. Crew is pouring today.
Driveway Inspection Passed 7/25/2022 7/25/2022 07/25/2022
Misc
Informational
07/18/2022
7-18-22 RH. Forms were up and currently meet ADA and LS specification. Aggregate was place and compacted. Crew is pouring today. 7-25-22 RH. Driveway was poured and meets LS and ADA specification.
Sidewalk Inspection Passed 7/25/2022 7/25/2022 07/25/2022
Misc
Informational
07/18/2022
7-18-22 RH. Forms were up and currently meet ADA and LS specification. Aggregate was place and compacted. Crew is pouring today. 7-25-22 RH. Sidewalk was poured and meets ADA and LS specification.
Erosion Control Inspection Residential Passed 9/9/2022 9/9/2022 09/09/2022
Plot Plan Inspection Passed 09/09/2022
Occupancy Inspection - Codes Residential Failed 9/9/2022 9/9/2022 09/09/2022
Misc
Corrective Action Required
09/09/2022
-resolve outstanding inspection fees -GFCI protection required at tv outlet covered deck -complete electrical for jacuzzi tub, electrical wild in tub cavity -provide handrail bottom flight basement stairs -provide deadbolt at basement walkout -provide security screws basement walkout -interconnection required of all smokes -uncover water meter lid -nail off joist hangers at deck -paint gas line stubs at rear and side of lot -Sump pump discharge min 36” from foundation
Occupancy Inspection - Codes Residential Full C of O 9/13/2022 9/13/2022 09/13/2022
Misc
Resolved
09/13/2022
Documents & Images
Date Uploaded File Type Document Name
11/08/2021 RR #117 - PERMIT APP
11/09/2021 Approved Plans Approved Drawings
11/09/2021 Approved Plans Approved Truss Layout
11/09/2021 Approved Plans Approved Truss Pacakge
11/09/2021 Plot Plan Approved Plot Plan
11/09/2021 Permit Codes Residential Plan Review
11/09/2021 Permit DS Building Permit
11/09/2021 Receipt Receipt for transaction:2021-008607
01/05/2022 117 Reserve at Stoney Creek-FTNG
01/05/2022 117 Reserve at Stoney Creek-FDTN
01/06/2022 Letter INSPECTION SUMMARY
01/06/2022 Letter INSPECTION SUMMARY
01/26/2022 Letter INSPECTION SUMMARY
01/26/2022 Letter INSPECTION SUMMARY
01/26/2022 Letter INSPECTION SUMMARY
01/27/2022 Letter INSPECTION SUMMARY
03/08/2022 Letter INSPECTION SUMMARY
05/25/2022 Letter INSPECTION SUMMARY
05/25/2022 Letter INSPECTION SUMMARY
05/25/2022 Letter INSPECTION SUMMARY
05/25/2022 Letter INSPECTION SUMMARY
06/06/2022 Letter INSPECTION SUMMARY
06/06/2022 Letter INSPECTION SUMMARY
06/06/2022 Letter INSPECTION SUMMARY
06/06/2022 Letter INSPECTION SUMMARY
06/13/2022 Letter INSPECTION SUMMARY
06/14/2022 117 Reserve at Stoney Creek Letter
06/14/2022 Approved Plans Approved Truss Repair
06/15/2022 Letter INSPECTION SUMMARY
06/15/2022 Letter INSPECTION SUMMARY
06/15/2022 Letter INSPECTION SUMMARY
07/18/2022 Letter INSPECTION SUMMARY
07/18/2022 Letter INSPECTION SUMMARY
07/25/2022 Letter INSPECTION SUMMARY
07/25/2022 Letter INSPECTION SUMMARY
09/09/2022 Letter INSPECTION SUMMARY
09/09/2022 Letter INSPECTION SUMMARY
09/09/2022 Letter INSPECTION SUMMARY
09/12/2022 Receipt Receipt for transaction:2022-007443
09/13/2022 Letter Field Certificate of Occupancy
09/13/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home