Summary
PRRES20215781
Building Permit - Residential
Certificate of Occupancy
SAB CONSTRUCTION LLC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK
11/04/2021
11/09/2021
05/07/2022
03/17/2023
Locations
Contacts
SAB CONSTRUCTION INC, Address:PO BOX 942, Phone:(816) 524-3855  
SAB CONSTRUCTION LLC, Address:PO BOX 942, Phone:(816) 524-3855  
Curtis Tate, Address:PO box 942   
TEAGUE ELECTRIC CONSTRUCTION INC, Address:12425 W 92ND ST, Phone:(913) 529-4600  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
GARRISON PLUMBING, Address:15430 S MAHAFFIE ST STE 102, Phone:(913) 768-1311  
Zack Bryant, Address:PO Box 942  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $630.00 $630.00 Paid 11/09/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 11/09/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 11/09/2021
9110078-Valuation Fee New Single Family $1,724.43 $1,724.43 Paid 11/09/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 11/09/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 11/09/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sewer Service Inspection - R Passed 12/10/2021 (11:30) 12/10/2021 12/10/2021
Water Service Inspection - R Passed 12/14/2021 (1:15) 12/14/2021 12/14/2021
Underslab Plumbing Inspection - Residential Passed 12/15/2021 12/15/2021 12/15/2021
Electrical Service Inspection Passed 4/28/2022 4/28/2022 04/28/2022
Gas Service Inspection - Residential Failed 4/28/2022 4/28/2022 04/28/2022
G2417.4.1 Test Pressure
Corrective Action Required
04/28/2022
INSPECTION, TESTING AND PURGING. AMENDED 7-945. The test pressure to be used shall be not less than one and one-half times the proposed maximum working pressure, but not less than 10 psig (68.9kPa) irrespective of design pressure. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure, the test pressure shall not be less than 60 psig. Where the test pressure exceeds 125 psig (862 kPa gauge), the test pressure shall not exceed a value that produces a hoop stress in the piping greater than 50 percent of the specified minimum yield strength of the pipe.
All Rough Inspection - Residential Failed 4/28/2022 4/28/2022 04/28/2022
Misc
Corrective Action Required
04/28/2022
-Maintain erosion control at perimeter of lot and clean debris from streets before any further inspections -Complete nailing pattern on exterior sheathing at PFH and all braced walls -Nail corner studs and intersecting walls per code -Tighten anchor bolts in garage -Provide hangers for rafters and joists not bearing on back garage wall single car bay -Address rafters not connected to ceiling joists at garage -Provide lateral restraint at ceiling joists above beam at garage -Fireblock gaps in furdown at dwv and nm -Fireblock top of dwv chase -Provide midpoint strap at all dwv 2” and smaller -Secure PEX lines 32” oc at half bath and kitchen stud space -Provide hangers at LVL/2x12 at entry -Provide hanger at (2) LVL to (2) 2x12 in office -Seal penetrations in return air joist space in master closet -Address holes bored closer than 2” in master closet ceiling joists all locations, kitchen all locations, breakfast area, -Address over bored stud in load bearing wall at laundry -Address top plate over bored in load bearing at laundry -Fireblock top of fur out in laundry -Provide Proper hanger at double LVL to beam both sides -Address rafters not connected to ceiling joists at great room, upstairs laundry, -Seal bottom and plate penetrations at loft exterior wall -Provide clearance to combustibles at b vent or provide manufacturers installation instructions for zero clearance to roof sheathing -Land electrical at top of stairs -Fireblock floor sheathing at tub at bath 2 -Seal stud penetrations at return air bed 2 -Provide structural straps at top plates bored greater than 50% in LBW at hallway and bed 2/3 -Provide joist hangers bed 3 closet -Stud and top plate over bored bath 3 -Sister over notched studs at basement wall near SGD -(3) studs required at exterior corners in basement -Provide anchor bolts per code at SGD both sides, plate breaks, end of plates etc. throughout -Solid block joists above beam -No pressure at gas piping
Miscellaneous Inspection Failed 05/02/2022
Miscellaneous Correction
Corrective Action Required
05/02/2022
5-2-22 AN there is a sanitary sewer manhole buried on the lot and it needs to be exposed
All Rough Inspection - Residential Failed 5/10/2022 5/10/2022 05/10/2022
Misc
Corrective Action Required
04/28/2022
-Fireblock top of dwv chase -Address over bored stud in load bearing wall at laundry **nail the trim to stud to reinforce it; Fireblock top of fur out in laundry -Strap top plates bored more than 50% at laundry bearing wall -Land electrical at top of stairs -Provide structural straps at top plates bored greater than 50% in LBW at hallway and bed 2/3 **MAKE SURE TO INSULATE THE 2ND FL LAUNDRY PLUMBING **OK TO INSULATE
Gas Service Inspection - Residential Passed 5/10/2022 5/10/2022 05/10/2022
G2417.4.1 Test Pressure
Resolved
05/10/2022
INSPECTION, TESTING AND PURGING. AMENDED 7-945. The test pressure to be used shall be not less than one and one-half times the proposed maximum working pressure, but not less than 10 psig (68.9kPa) irrespective of design pressure. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure, the test pressure shall not be less than 60 psig. Where the test pressure exceeds 125 psig (862 kPa gauge), the test pressure shall not exceed a value that produces a hoop stress in the piping greater than 50 percent of the specified minimum yield strength of the pipe.
All Rough Inspection - Residential Failed 5/13/2022 5/13/2022 05/13/2022
Misc
Corrective Action Required
05/10/2022
-Provide structural straps at top plates bored greater than 50% in LBW at hallway and bed 2/3 **install min 4 nails on each side, not 2 nails
Footing Inspection - Residential Passed 05/16/2022
Informational
05/16/2022
FOOTING APPROVED BY ENGINEER
Piers/Caissons Inspection - Residential Passed 05/16/2022
Informational
05/16/2022
PIERS APPROVED BY ENGINEER
All Rough Inspection - Residential Passed 5/17/2022 5/17/2022 05/17/2022
Misc
Resolved
05/17/2022
-Provide structural straps at top plates bored greater than 50% in LBW at hallway and bed 2/3 **install min 4 nails on each side, not 2 nails
Driveway Inspection Partial 7/7/2022 07/07/2022
Misc
Informational
07/07/2022
7-7-22 RH. Forms are in place and aggregate is present and compacted. No Sidewalk
Driveway Inspection Failed 7/18/2022 7/18/2022 07/12/2022
Misc
Informational
07/07/2022
7-7-22 RH. Forms are in place and aggregate is present and compacted. No Sidewalk 7-12-22 RH. Driveway meets ADA and LS specification. Need to patch curb in front of driveway.
Sidewalk Inspection Partial 8/3/2022 8/3/2022 08/03/2022
Misc
Informational
08/03/2022
8-3-22 AN forms are in place and aggregate is present and compacted
Driveway Inspection Passed 08/03/2022
Misc
Informational
07/12/2022
7-7-22 RH. Forms are in place and aggregate is present and compacted. No Sidewalk 7-12-22 RH. Driveway meets ADA and LS specification. Need to patch curb in front of driveway..
Sidewalk Inspection Passed 8/5/2022 8/5/2022 08/12/2022
Misc
Informational
08/03/2022
8-3-22 AN forms are in place and aggregate is present and compacted 8-12-22 AN sidewalk looks good and meets Ada spec
Plot Plan Inspection Passed 9/27/2022 09/27/2022
Miscellaneous Inspection Passed 5/10/2022 01/31/2023
Miscellaneous Correction
Resolved
01/31/2023
5-2-22 AN there is a sanitary sewer manhole buried on the lot and it needs to be exposed
Occupancy Inspection - Codes Residential Failed 1/31/2023 1/31/2023 01/31/2023
Misc
Corrective Action Required
01/31/2023
-Obtain lawn irrigation permit and submit backflow valve test report to city -Provide min 6” clearance from siding to grade -Verify that the deck beam hanger is secured to the floor rim with long ledgerlok screws -Seal lawn irrigation line exterior wall penetration -Provide sewer tracer wire port at grade -Remove or cover insulation paper facing below stair -Provide AFCI protection for all outlets required per NEC 210.12. (Both clothes washers) -Remove all foundation wall ties -Fb floor penetration by bath fan duct near future basement bathroom
Occupancy Inspection - Codes Residential Failed 3/14/2023 3/14/2023 03/14/2023
Misc
Corrective Action Required
01/31/2023
-Verify that the deck beam hanger is secured to the floor rim with long ledgerlok screws
Occupancy Inspection - Codes Residential Full C of O 03/17/2023
Misc
Resolved
03/17/2023
-Verify that the deck beam hanger is secured to the floor rim with long ledgerlok screws
Documents & Images
Date Uploaded File Type Document Name
11/04/2021 mo137 permit app
11/04/2021 LOT 137 FINAL
11/04/2021 mo137 excise tax app
11/04/2021 Approved Plans approved plans
11/08/2021 Permit Codes Residential Plan Review
11/09/2021 Plot Plan APPROVED PLOT PLAN
11/09/2021 Permit Codes Residential Plan Review
11/09/2021 Permit DS Building Permit
11/09/2021 Receipt Receipt for transaction:2021-008613
11/24/2021 M L Crose 4732 NE Jamestown Dr LSMO Monticello Lot 137 3rd Party Footing Inspection Report 11-18-21
12/10/2021 Letter INSPECTION SUMMARY
12/14/2021 Letter INSPECTION SUMMARY
12/15/2021 Letter INSPECTION SUMMARY
01/10/2022 Final_2021_12_23_DPier_LSMO_Pat Cochran Concrete
04/28/2022 Letter INSPECTION SUMMARY
04/28/2022 Letter INSPECTION SUMMARY
04/28/2022 Letter INSPECTION SUMMARY
05/02/2022 Letter INSPECTION SUMMARY
05/10/2022 Letter INSPECTION SUMMARY
05/10/2022 Letter INSPECTION SUMMARY
05/13/2022 Letter INSPECTION SUMMARY
05/16/2022 Letter INSPECTION SUMMARY
05/16/2022 Letter INSPECTION SUMMARY
05/17/2022 Letter INSPECTION SUMMARY
07/07/2022 Letter INSPECTION SUMMARY
07/12/2022 Letter INSPECTION SUMMARY
08/03/2022 Letter INSPECTION SUMMARY
08/03/2022 Letter INSPECTION SUMMARY
08/12/2022 Letter INSPECTION SUMMARY
09/26/2022 Plot Plan APPROVED AS GRADED PLOT PLAN
09/27/2022 Letter INSPECTION SUMMARY
01/31/2023 Letter INSPECTION SUMMARY
03/14/2023 Letter INSPECTION SUMMARY
03/14/2023 Letter INSPECTION SUMMARY
03/17/2023 Email Deck letter from framer_ 4732 NE Jamestown Dr_
03/17/2023 Letter Codes Final Certificate of Occupancy
03/17/2023 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home