Permit Application Status

PRRES20215424


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20215424
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. FINISHED BASEMENT. STOP WORK ORDER generated on 12/14/2021 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 12/15/2021 12:00 AM by username 'Mitchell Schwarz'.
10/18/2021
10/28/2021
04/19/2022
06/30/2022
Locations
Contacts
ELEVATE DESIGN & BUILD LLC, Address:350 SW LONGVIEW BLVD, Phone:(816) 622-8826  
Elevate Design + Build , Address:350 Longview Blvd.   
R-MECH HEATING COOLING PLUMBING/RHODES HEATING COOLING PLUMBING AND ROOTER, Address:1425 AGNES AVE, Phone:(816) 920-5955  
ELECTRICAL CONNECTIONS, Address:20112 HOPS CREEK DR, Phone:(816) 838-6946  
CENTRAL PLUMBING HTG & A/C INC, Address:P O BOX 218, Phone:(816) 942-6355  
Glen Hoelting, Address:350 SW Longview Blvd  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $420.00 $420.00 Paid 10/28/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 10/28/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 10/28/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 10/28/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 10/28/2021
9110078-Valuation Fee New Single Family $852.06 $852.06 Paid 10/28/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Failed 12/14/2021 12/14/2021 12/14/2021
Misc
Corrective Action Required
12/14/2021
INSPECTION DENIED FOOTING POURED WITHOUT INSPECTION.
Footing Inspection - Residential Failed - Stop Work 12/14/2021 12/14/2021
Misc
Corrective Action Required
12/14/2021
FOOTING POURED WITHOUT INSPECTION.
Footing Inspection - Residential Passed 12/15/2021 12/15/2021
Misc
Resolved
12/15/2021
FOOTING POURED WITHOUT INSPECTION.
Misc
Informational
12/15/2021
3RD PARTY INSPECTION UFER GROUND ROD IS LOCATED WHERE INDICATED ON 3RD PARTY INSPECTION REPORT
Sewer Service Inspection - R Passed 12/15/2021 (1:30) 12/15/2021 12/15/2021
Underslab Plumbing Inspection - Residential Passed 12/16/2021 12/16/2021 12/16/2021
Misc
Resolved
12/16/2021
INSPECTION DENIED FOOTING POURED WITHOUT INSPECTION.
Water Service Inspection - R Passed 12/16/2021 (1:30) 12/16/2021 12/16/2021
Footing Inspection - Residential Passed 12/30/2021 12/30/2021
Piers/Caissons Inspection - Residential Passed 1/11/2022 01/11/2022
Misc
Informational
01/11/2022
third party inspection performed.
Gas Service Inspection - Residential Passed 4/6/2022 4/6/2022 04/06/2022
Electrical Service Inspection Passed 4/6/2022 4/6/2022 04/06/2022
All Rough Inspection - Residential Failed 4/6/2022 4/6/2022 04/06/2022
Misc
Corrective Action Required
04/06/2022
-furr down for hvac for insulation in garage -provide area for insulation for hvac not in thermal environment see garage -fireblock W wall into furr down in garage -missing double joist above bed 4 -stud packs per plans at mechanical room entry -missing stud packs in garage per plans -complete fire place install -address rafters over notched through out vaulted ceiling area -fire block top of furr out wall in hall bath -address bath fan vent in hall bath -address lvl rafter not landing on top plate near master bath entry -address roof supports landing on non bearing walls -collar ties above bed 3 -address non contentious studs at gable wall in living room -fireblock N kitchen wall to ceiling space -seal all bottom and top plate penetrations through out
All Rough Inspection - Residential Failed 4/25/2022 4/25/2022 04/25/2022
Misc
Corrective Action Required
04/06/2022
-complete fire place install (protect gas and secure) -fire block gas line at fire place -address rafters over notched through out vaulted ceiling area -fire block top of furr out wall in hall bath -address bath fan vent in hall bath -address lvl rafter not landing on top plate near master bath entry -address roof supports landing on non bearing walls -address non contentious studs at gable wall in living room -fireblock N kitchen wall to ceiling space -seal all bottom and top plate penetrations through out
Erosion Control Inspection Residential Failed 5/3/2022 05/03/2022
DCM5 ESC INSP DENIED
Corrective Action Required
05/03/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
05/03/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
05/03/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
All Rough Inspection - Residential Failed 5/3/2022 5/3/2022 05/03/2022
Misc
Corrective Action Required
04/25/2022
-inspection denied due to lack of erosion control -complete fire place install (protect gas and secure) -fire block gas line at fire place -address rafters over notched through out vaulted ceiling area -fire block top of furr out wall in hall bath -address bath fan vent in hall bath -address lvl rafter not landing on top plate near master bath entry -address roof supports landing on non bearing walls -address non contentious studs at gable wall in living room -fireblock N kitchen wall to ceiling space -seal all bottom and top plate penetrations through out
All Rough Inspection - Residential Passed 5/6/2022 5/6/2022 05/06/2022
Misc
Resolved
05/06/2022
-address rafters over notched through out vaulted ceiling area -fire block top of furr out wall in hall bath -address bath fan vent in hall bath -address lvl rafter not landing on top plate near master bath entry -address roof supports landing on non bearing walls -address non contentious studs at gable wall in living room -fireblock N kitchen wall to ceiling space -seal all bottom and top plate penetrations through out
Plot Plan Inspection Passed 6/29/2022 06/29/2022
Erosion Control Inspection Residential Passed 6/29/2022 06/29/2022
DCM5 ESC INSP DENIED
Resolved
06/29/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
06/29/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM3 ESC REQUIRED 2 DAY
Resolved
06/29/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Occupancy Inspection - Codes Residential Temporary C of O 6/29/2022 6/29/2022 06/29/2022
Misc
Corrective Action Required
06/29/2022
TCO UNTIL 7/29/22 -address pending drive way inspection -illuminate premises identification -(2) 1/2” through bolts at each deck post to beam connection -tamper caps at A/c unit -secure A/c whip up off of ground
Driveway Inspection Passed 6/29/2022 6/29/2022 06/29/2022
Misc
Informational
06/29/2022
On 6.29.2022 Wednesday The driveway appears to be compliance.
Occupancy Inspection - Codes Residential Full C of O 6/30/2022 6/30/2022 06/30/2022
Misc
Resolved
06/30/2022
TCO UNTIL 7/29/22 -address pending drive way inspection -illuminate premises identification -(2) 1/2” through bolts at each deck post to beam connection -tamper caps at A/c unit -secure A/c whip up off of ground
Documents & Images
Date Uploaded File Type Document Name
10/18/2021 License_Tax_Application
10/18/2021 Residental Permit Application
10/21/2021 Permit Codes Residential Plan Review
10/27/2021 21-10-26 - HF 017 - Review Comment Response
10/27/2021 Approved Plans APPROVED DRAWINGS
10/27/2021 Plot Plan APPROVED PLOT PLAN
10/27/2021 Permit Codes Residential Plan Review
10/28/2021 Permit DS Building Permit
10/28/2021 Receipt Receipt for transaction:2021-008326
12/14/2021 Letter INSPECTION SUMMARY
12/14/2021 Letter Stop Work Order
12/15/2021 17 Hook Farms FTNG
12/15/2021 17 Hook Farms FTNG0
12/15/2021 Letter INSPECTION SUMMARY
12/15/2021 Letter INSPECTION SUMMARY
12/16/2021 Letter INSPECTION SUMMARY
12/16/2021 Letter INSPECTION SUMMARY
12/16/2021 Letter INSPECTION SUMMARY
12/17/2021 17 Hook Farms Subgrade (2)
12/17/2021 17 Hook Farms Subgrade (1)
12/30/2021 Letter INSPECTION SUMMARY
01/10/2022 Final_2021_12_23_DPier_LSMO_Pat Cochran Concrete
01/10/2022 Final_2021_12_23_DPier_LSMO_Pat Cochran Concrete
01/11/2022 Letter INSPECTION SUMMARY
04/06/2022 Letter INSPECTION SUMMARY
04/06/2022 Letter INSPECTION SUMMARY
04/06/2022 Letter INSPECTION SUMMARY
04/25/2022 Letter INSPECTION SUMMARY
04/29/2022 2038 SW Hook Farm Drive_Framing Evaluation Report_4-25-22
05/03/2022 Letter INSPECTION SUMMARY
05/03/2022 Letter INSPECTION SUMMARY
05/06/2022 Letter INSPECTION SUMMARY
06/29/2022 Letter INSPECTION SUMMARY
06/29/2022 Letter INSPECTION SUMMARY
06/29/2022 Letter Codes Temporary Certificate of Occupancy
06/29/2022 Letter INSPECTION SUMMARY
06/30/2022 Letter Codes Final Certificate of Occupancy
06/30/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home