Summary
PRRES20215373
Building Permit - Residential
Certificate of Occupancy
TRUMARK HOMES LLC
NEW SINGLE FAMILY
NEW CONSTRUCTION. FINISHED BASEMENT. COVERED DECK.
10/13/2021
10/20/2021
04/13/2022
11/02/2022
Locations
Contacts
TRUMARK HOMES, LLC, Address:PO BOX 728, Phone:(816) 564-5613  
TRUMARK HOMES LLC, Address:500 NW MANOR DR  
MARK A YANCIK, Address:508 nw manor dr  
TRUMARKHOMES.MARK@GMAIL.COM  
C.M. MOSE & SON, Address:6603 ROYAL ST BLDG E, Phone:(816) 781-4707  
IMPACT ELECTRICAL SOLUTIONS LLC, Address:14 ANCHOR DRIVE, Phone:(816) 674-9345  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $450.00 $450.00 Paid 10/20/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 10/20/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 10/20/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 10/20/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 10/20/2021
9110078-Valuation Fee New Single Family $1,066.56 $1,066.56 Paid 10/20/2021
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 08/18/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Failed 11/23/2021 11/23/2021
DCM5 ESC INSP DENIED
Corrective Action Required
11/23/2021
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. INSTALL EROSION CONTROL ALONG THE BACK SIDE OF LOT
Underslab Plumbing Inspection - Residential Failed 11/23/2021 11/23/2021 11/23/2021
Misc
Corrective Action Required
11/23/2021
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. INSTALL EROSION CONTROL ALONG THE BACK SIDE OF LOT
Underslab Plumbing Inspection - Residential Passed 12/2/2021 12/2/2021 12/02/2021
Misc
Resolved
12/02/2021
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. INSTALL EROSION CONTROL ALONG THE BACK SIDE OF LOT
Sewer Service Inspection - R Passed 12/10/2021 (1:00) 12/10/2021 12/10/2021
Water Service Inspection - R Passed 12/14/2021 12/14/2021
All Rough Inspection - Residential Failed 3/2/2022 3/2/2022 03/02/2022
Misc
Corrective Action Required
03/02/2022
-Install flashing above garage door -Shim gap under garage studs -Fur out laundry wall for dryer duct. Code requires that the duct cannot be distorted from its round shape. Use 2x6 wall next time -Support joists to header above basement window -Solid block underneath rear dining lvl beam point load **OK TO INSULATE **ACCESS TO UFER GROUNDING CONNECTION REQ AT FINAL INSPECTION
Gas Service Inspection - Residential Passed 3/2/2022 3/2/2022 03/02/2022
Electrical Service Inspection Passed 3/2/2022 03/02/2022
All Rough Inspection - Residential Passed 3/8/2022 3/8/2022 03/08/2022
Misc
Resolved
03/08/2022
-Install flashing above garage door -Shim gap under garage studs -Fur out laundry wall for dryer duct. Code requires that the duct cannot be distorted from its round shape. Use 2x6 wall next time -Support joists to header above basement window -Solid block underneath rear dining lvl beam point load **OK TO INSULATE **ACCESS TO UFER GROUNDING CONNECTION REQ AT FINAL INSPECTION
Driveway Inspection Partial 4/18/2022 4/18/2022 04/18/2022
Misc
Informational
04/18/2022
Driveway was framed up with aggregate in and compacted. 4/18/22 ES
Erosion Control Inspection Residential Failed 6/3/2022 06/03/2022
DCM5 ESC INSP DENIED
Corrective Action Required
11/23/2021
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. INSTALL EROSION CONTROL ALONG THE BACK SIDE OF LOT
Miscellaneous Correction
Corrective Action Required
06/03/2022
No erosion control up. Mud an silt flowing down hill to 4820 Jamestown.
Footing Inspection - Residential Passed 6/7/2022 06/07/2022
Informational
06/07/2022
FOOTING APPROVED BY ENGINEER
Occupancy Inspection - Codes Residential Failed 8/9/2022 8/9/2022 08/09/2022
Misc
Corrective Action Required
08/09/2022
no inspection- - no address - no erosion control - straw wattles are in the street. plumber still working Mud and silt covering city sidewalk into storm drain. Address above items before re-scheduling.
Occupancy Inspection - Codes Residential Failed 8/16/2022 8/16/2022 08/16/2022
Misc
Corrective Action Required
08/09/2022
**INSTALL EROSION CONTROL ALONG THE REAR OF LOT -Piers not inspected and approved by city -Sidewalk and driveway not approved on record -Final grade, sod, downspout and sump pump extension -Provide sewer tracer wire port at grade -Provide min 40 amp circuit for cooktop (9.2 kw) -Provide combustion air openings for the water heater. -Insulate at mechanical space rim joist -Ufer grounding connection must be accessible
Driveway Inspection Passed 8/18/2022 8/18/2022 08/18/2022
Misc
Informational
04/18/2022
Driveway was framed up with aggregate in and compacted. 4/18/22 ES 8-18-22 AN driveway looks good and meets Ada spec
Sidewalk Inspection Failed 8/18/2022 8/18/2022 08/18/2022
Misc
Corrective Action Required
08/18/2022
8-18-22 AN. 4 or 5 sidewalk panels on the right side of the house are damaged and need to be replaced. Spoke with the builder and he said he would replace them.
Erosion Control Inspection Residential Passed 08/18/2022
DCM5 ESC INSP DENIED
Resolved
08/18/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. INSTALL EROSION CONTROL ALONG THE BACK SIDE OF LOT
Miscellaneous Correction
Resolved
08/18/2022
No erosion control up. Mud an silt flowing down hill to 4820 Jamestown.
Occupancy Inspection - Codes Residential Ready for Temp CO 8/18/2022 8/18/2022 08/18/2022
Misc
Corrective Action Required
08/16/2022
-Sidewalk not approved on record -Sod -Provide combustion air openings for the water heater.
Sidewalk Inspection Passed 8/19/2022 8/19/2022 08/29/2022
Misc
Corrective Action Required
08/18/2022
8-18-22 AN. 4 or 5 sidewalk panels on the right side of the house are damaged and need to be replaced. Spoke with the builder and he said he would replace them. 8-29-22 AN sidewalk was replace and looks good
Sidewalk Inspection Passed 9/27/2022 9/27/2022 09/27/2022
Misc
Informational
09/27/2022
9-27-22 AN. Sidewalk has been fixed and looks good
Occupancy Inspection - Codes Residential Full C of O 11/3/2022 11/2/2022 11/02/2022
Misc
Resolved
11/02/2022
-Provide combustion air openings for the water heater.
Documents & Images
Date Uploaded File Type Document Name
10/15/2021 SKM_C36821101507040
10/15/2021 Approved Plans APPROVED DRAWINGS
10/15/2021 Permit Codes Residential Plan Review
10/18/2021 Plot Plan APPROVED PLOT PLAN
10/18/2021 Permit Codes Residential Plan Review
10/20/2021 Permit DS Building Permit
10/20/2021 Receipt Receipt for transaction:2021-008113
11/23/2021 Letter INSPECTION SUMMARY
11/23/2021 Letter INSPECTION SUMMARY
11/23/2021 M L Crose 4812 NE Jamestown Dr LSMO MC Lot 125 Trumark Permit 2021-5373 Foundation footing Inspection Report 11-5-21
12/02/2021 Letter INSPECTION SUMMARY
12/10/2021 Letter INSPECTION SUMMARY
12/14/2021 Letter INSPECTION SUMMARY
01/19/2022 SKM_C36822011906591
03/02/2022 Letter INSPECTION SUMMARY
03/02/2022 Letter INSPECTION SUMMARY
03/02/2022 Letter INSPECTION SUMMARY
03/08/2022 Letter INSPECTION SUMMARY
04/18/2022 Letter INSPECTION SUMMARY
06/03/2022 Letter INSPECTION SUMMARY
06/07/2022 Letter INSPECTION SUMMARY
07/07/2022 Plot Plan APPROVED PLOT PLAN
08/09/2022 Letter INSPECTION SUMMARY
08/16/2022 Letter INSPECTION SUMMARY
08/18/2022 Letter INSPECTION SUMMARY
08/18/2022 Letter INSPECTION SUMMARY
08/18/2022 Letter INSPECTION SUMMARY
08/18/2022 Receipt Receipt for transaction:2022-006815
08/29/2022 Letter INSPECTION SUMMARY
09/27/2022 Letter INSPECTION SUMMARY
11/02/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home