Permit Application Status

PRRES20214946


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20214946
Building Permit - Residential
Certificate of Occupancy
NEW MARK HOMES KC LLC
NEW SINGLE FAMILY
NEW HOUSE. FINISHED WALKOUT BASEMENT. COVERED DECK.
09/21/2021
10/04/2021
03/22/2022
07/25/2023
Locations
Contacts
NEW MARK HOMES - KC LLC, Address:5207 NW CROOKED ROAD, Phone:(816) 969-9010  
NEW MARK HOMES KC LLC, Address:5207 NW CROOKED RD  
Ashley Kirby, Address:5207 NW Crooked Rd, Phone:(816) 969-9010  
HARRINGTON BROTHERS HEATING & COOLING, Address:15630 S KEELER ST, Phone:(913) 422-5444  
CLASS ONE ELECTRIC INC, Address:PO BOX 24343, Phone:(913) 915-1767  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $510.00 $510.00 Paid 10/04/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 10/04/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 10/04/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 10/04/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 10/04/2021
9110078-Valuation Fee New Single Family $1,334.27 $1,334.27 Paid 10/04/2021
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 04/17/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 07/20/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 07/20/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 11/15/2021 (10:30) 11/15/2021 11/15/2021
Misc
Corrective Action Required
11/15/2021
1 pier pad over dug,
Misc
Corrective Action Required
11/15/2021
1 pier pad over dug,
Underslab Plumbing Inspection - Residential Passed 12/27/2021 12/27/2021 12/27/2021
Erosion Control Inspection Residential Failed 1/21/2022 1/21/2022 01/21/2022
Misc
Corrective Action Required
01/21/2022
-MAINTAIN SILT FENCE AT FRONT OF LOT, CLEAN DEBRIS FROM STREET, CLEAN DEBRIS FROM STORM INLET AND REPLACE GUTTER BUDDY
Piers/Caissons Inspection - Residential Failed 3/28/2022 (11:30) 3/28/2022 03/28/2022
Miscellaneous Correction
Corrective Action Required
03/28/2022
PLANS CALL FOR (2) 24 X 36 PIERS SOUTH PIER APPROVED NORTH PIER NOT 24" IN DIAMETER BREAK ROCK OR PROVIDE ENGINEERS LETTER
Sewer Service Inspection - R Failed 4/1/2022 (3:30) 4/1/2022 04/01/2022
Misc
Corrective Action Required
04/01/2022
COMPLETE SEWER LINE
Sewer Service Inspection - R Passed 4/4/2022 04/04/2022
Misc
Resolved
04/04/2022
Water Service Inspection - R Passed 4/5/2022 4/5/2022 04/05/2022
Piers/Caissons Inspection - Residential Passed 4/7/2022 (8:00) 4/7/2022 04/07/2022
Miscellaneous Correction
Corrective Action Required
03/28/2022
PLANS CALL FOR (2) 24 X 36 PIERS SOUTH PIER APPROVED NORTH PIER NOT 24" IN DIAMETER BREAK ROCK OR PROVIDE ENGINEERS LETTER
Electrical Service Inspection Passed 9/19/2022 9/19/2022 09/19/2022
Gas Service Inspection - Residential Passed 9/19/2022 9/19/2022 09/19/2022
All Rough Inspection - Residential Failed 9/19/2022 9/19/2022 09/19/2022
Misc
Corrective Action Required
09/19/2022
-maintain overgrown weeds and vegetation on lot -nail all exterior sheathing per plans -unable to determine 3” oc nailing pattern at garage PFH with tyvek/eyebrow cover -full height 6x6 post per plans at covered deck -provide anchor bolts within 12” of plate break garage -min 24” lap between dbl top plate breaks- see garage, 1st floor East bedroom -provide joist hangers at ceiling joist to dbl 2x10 connection at garage wall cantilevers, joists supported by cantilevers -provide lateral restraint at ceiling joists garage -fireblock between furring strips at top plate laundry wall -provide bocca protection plate at bottom plate DWV laundry -provide stud shoe at stud laundry/garage wall notched for DWV -1st floor East bedroom, address corner lap connection per code at NE corner, different plate heights -protect NM kitchen island 6” AFF -address top plate corner lap connection, different wall heights at great room to breakfast ext walls -collar ties every 48” oc -master Bedroom lvl hip landing on plate above dbl 2x12 ceiling box, no support, different plate heights no with no lap connection -support hips -plate heights change with no corner lap connection at master bath and front bedroom -address overnotched hips, more than 25% -nail off joist hangers master bed -fireblock between studs at master bed fireplace wall -purlin struts T bracing design per plans -purlin struts and support all locations per plans -unable to determine support for covered deck lvl beams at house with cover -over 12’ length 2x4 studs at front office load bearing wall -provide (3) studs at corner NW corner and NE of both basement bedrooms exterior walls, 2x6 to 2x4 wall -fireblock vertical to horizontal at furred down soffit ends basement -fireblock vertical every 10’ between studs and foundation/framing at finished basement -seal all penetrations through air returns at basement -solid block between joists at cantilevers -provide security blocking at basement walkout -pex water line above service panel basement -(3) 2x10 header at basement den windows per plans
Erosion Control Inspection Residential Failed 9/19/2022 9/19/2022 09/19/2022
Misc
Resolved
09/19/2022
-MAINTAIN SILT FENCE AT FRONT OF LOT, CLEAN DEBRIS FROM STREET, CLEAN DEBRIS FROM STORM INLET AND REPLACE GUTTER BUDDY
Misc
Corrective Action Required
09/19/2022
-maintain overgrown weeds and vegetation on lot
All Rough Inspection - Residential Passed 10/3/2022 10/3/2022 10/03/2022
Misc
Resolved
10/03/2022
Driveway Inspection Partial 10/12/2022 10/12/2022 10/12/2022
Misc
Informational
10/12/2022
Driveway was framed up with aggregate in and compacted. 10/12/22 ES
Sidewalk Inspection Partial 10/12/2022 10/12/2022 10/12/2022
Misc
Informational
10/12/2022
Sidewalk was framed up with aggregate in and compacted. 10/12/22 ES
Driveway Inspection Passed 10/21/2022 10/21/2022 10/21/2022
Misc
Informational
10/12/2022
Driveway was framed up with aggregate in and compacted. 10/12/22 ES Driveway meets LS and ADA spec. 10/21/22 ES
Sidewalk Inspection Passed 10/21/2022 10/21/2022 10/21/2022
Misc
Informational
10/12/2022
Sidewalk was framed up with aggregate in and compacted. 10/12/22 ES Sidewalk meets LS and ADA spec. 10/21/22 ES
Erosion Control Inspection Residential Failed 2/22/2023 02/22/2023
Misc
Resolved
02/22/2023
-maintain overgrown weeds and vegetation on lot
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
02/22/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/22/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/22/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Occupancy Inspection - Codes Residential Failed 4/13/2023 4/13/2023 04/13/2023
Misc
Corrective Action Required
04/13/2023
- Final grading and sod - Provide splash pads divert water 36” away from foundation - Obtain an irrigation permit - Provide window cranking handle for basement Egress window, behind bar - Label outlet at sump and lawn sprinkler as non GFCI - Provide security screws at basement and front door - Seal top of meter can
Erosion Control Inspection Residential Passed 4/13/2023 04/13/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
04/13/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM2 ESC DEFICIENT INSTALLATION
Resolved
04/13/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM3 ESC REQUIRED 2 DAY
Resolved
04/13/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Occupancy Inspection - Codes Residential Ready for Temp CO 4/14/2023 4/14/2023 04/14/2023
Misc
Corrective Action Required
04/13/2023
- Final grading and sod - Provide splash pads divert water 36” away from foundation - Obtain an irrigation permit TCO expiration 5/14/23
Occupancy Inspection - Codes Residential Ready for Temp CO 5/17/2023 05/17/2023
Misc
Corrective Action Required
04/14/2023
- Final grading and sod - Provide splash pads divert water 36” away from foundation - Obtain an irrigation permit TCO expiration 6/22/23
Plot Plan Inspection Passed 6/21/2023 06/21/2023
Occupancy Inspection - Codes Residential Failed 6/21/2023 6/21/2023 06/21/2023
Misc
Corrective Action Required
05/17/2023
- Obtain an irrigation permit - Pay fees ( TCO extension fee ) - provide splash pads TCO expiration 4/14/23
Occupancy Inspection - Codes Residential Ready for Temp CO 6/22/2023 06/22/2023
Misc
Corrective Action Required
06/21/2023
- Obtain an irrigation permit - Pay fees ( TCO extension fee ) - provide splash pads TCO expiration 4/14/23
Occupancy Inspection - Codes Residential Full C of O 7/25/2023 7/25/2023 07/25/2023
Misc
Resolved
07/25/2023
- Obtain an irrigation permit - Pay fees ( TCO extension fee ) - provide splash pads
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home