Permit Application Status

PRRES20214505


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20214505
Building Permit - Residential
Certificate of Occupancy
NLV PERGOLA PARK LLC
NEW SINGLE FAMILY
NEW HOME. FINISHED BASEMENT. COVERED PATIO. ELEVATOR.
08/30/2021
09/10/2021
03/06/2022
10/25/2022
Locations
Contacts
BELLAH HOMES LLC, Address:P O BOX 346, Phone:(816) 697-2870  
NLV PERGOLA PARK LLC, Address:3152 SW GRANDSTAND CIR  
Paul Miller, Address:P.O. Box 346, Phone:(816) 786-5050  
A & D HEATING AND COOLING INC, Address:2006 W MAIN ST, Phone:(816) 537-7952  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
PAUL@BELLAHHOMES.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $420.00 $420.00 Paid 09/10/2021
Water Tap Fee $3,655.00 $3,655.00 Paid 09/10/2021
Water Meter Fee $479.24 $479.24 Paid 09/10/2021
Right of Way Permit Fee $85.00 $85.00 Paid 09/10/2021
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 09/10/2021
Valuation Fee New Single Family $1,122.91 $1,122.91 Paid 09/10/2021
Temporary Occupancy Fee $50.00 $50.00 Paid 10/04/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Failed 10/7/2021 10/7/2021 10/07/2021
Misc
Corrective Action Required
10/07/2021
NO INSPECTION PERFORMED BACKFILL AT FOUNDATION FOR ACCESS TO INSPECT
Sewer Service Inspection - R Passed 10/12/2021 (1:30) 10/12/2021 10/12/2021
Water Service Inspection - R Passed 10/15/2021 (1:00) 10/15/2021 10/15/2021
Misc
Informational
10/15/2021
UPLOADED PIC OF WATER METER PIT TO PERMIT JOSE SAID BUILDER TOLD HIM THIS WILL BE CORRECT AT FINAL GRADE
Erosion Control Inspection Residential Failed 10/15/2021 10/15/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/15/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE - - CLEAN STREET -
Underslab Plumbing Inspection - Residential Passed 10/22/2021 10/22/2021 10/22/2021
Misc
Corrective Action Required
10/07/2021
NO INSPECTION PERFORMED BACKFILL AT FOUNDATION FOR ACCESS TO INSPECT
Erosion Control Inspection Residential Passed 3/17/2022 03/17/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/15/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE - - CLEAN STREET -
All Rough Inspection - Residential Failed 4/20/2022 4/20/2022 04/20/2022
Miscellaneous Correction
Corrective Action Required
04/20/2022
-washer and nuts on portal frame garage - Provide window and man door in garage - Nail to code exterior wall corner in master suite - Fire block gaps at top plate and penetration above master bathroom sink - Fire block chase at top plate master shower and bedroom 2 shower - Nail exterior corner bedroom 2 - Protect SEC cable to sub panel in laundry less than 1 1/2” from face of stud - Fire block penetration in floor at fire place - Solid fire block chase above fire place into attic space - Provide anchors for steel columns - Plans call for 3 1/2” steel columns and 3” installed - Fire block end of soffit basement bedroom 3 - Fire block top of chase behind tub basement bathroom - Rafter ties on ridge should be 4’ oc great room
Electrical Service Inspection Passed 4/20/2022 4/20/2022 04/20/2022
Gas Service Inspection - Residential Failed 4/20/2022 4/20/2022 04/20/2022
Misc
Corrective Action Required
04/20/2022
no pressure on gauge.
Erosion Control Inspection Residential Failed 4/20/2022 04/20/2022
Misc
Corrective Action Required
04/20/2022
repair silt fence
All Rough Inspection - Residential Failed 4/25/2022 4/25/2022 04/25/2022
Miscellaneous Correction
Corrective Action Required
04/20/2022
- Provide man door in garage - Provide anchors for steel columns - Fire block end of chase basement bedroom 3 vertical to horizontal
Gas Service Inspection - Residential Passed 4/25/2022 4/25/2022 04/25/2022
Misc
Resolved
04/25/2022
no pressure on gauge.
All Rough Inspection - Residential Passed 4/26/2022 4/26/2022 04/26/2022
Miscellaneous Correction
Resolved
04/26/2022
Erosion Control Inspection Residential Failed 05/24/2022
Misc
Corrective Action Required
04/20/2022
repair silt fence
Misc
Corrective Action Required
05/24/2022
Silt fence on SW corner of property at Gale Dr/Sw Pergola park is not functioning, mud and silt are flowing underneath and have enveloped the ADA ramp at this location. Please correct. 5/24/22 ES
Erosion Control Inspection Residential Failed 05/24/2022
Misc
Corrective Action Required
05/24/2022
repair silt fence
Misc
Corrective Action Required
05/24/2022
Silt fence on SW corner of property at Gale Dr/Sw Pergola park is not functioning, mud and silt are flowing underneath and have enveloped the ADA ramp at this location. Please correct. 5/24/22 ES
Erosion Control Inspection Residential Failed 8/23/2022 08/23/2022
Misc
Corrective Action Required
05/24/2022
repair silt fence
Misc
Resolved
08/23/2022
Silt fence on SW corner of property at Gale Dr/Sw Pergola park is not functioning, mud and silt are flowing underneath and have enveloped the ADA ramp at this location. Please correct. 5/24/22 ES
Sidewalk Inspection Passed 9/19/2022 9/19/2022 09/19/2022
Misc
Informational
09/19/2022
On Monday, 9-19-2022 I (Tom Taylor) performed and passed a sidewalk inspection for concrete placement.
Water Service Inspection - R Partial 09/26/2022
Water Service Inspection - R Partial 09/26/2022
Misc
Informational
09/26/2022
On Monday, 6-26-2022 Miller Plumbing completed 4 water tie-ins for lots 1022 thru 1025. ( Tom Taylor inspected )
Footing Inspection - Residential Passed 09/30/2022
Misc
Informational
09/30/2022
INSPECTION PERFORMED BY THIRD PARTY DAVID AINSWORTH
Water Service Inspection - R Passed 09/30/2022
Misc
Informational
09/26/2022
On Monday, 6-26-2022 Miller Plumbing completed 4 water tie-ins for lots 1022 thru 1025. ( Tom Taylor inspected )
Erosion Control Inspection Residential Failed 9/30/2022 09/30/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
08/23/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - remove gravel and debris from street - provide erosion control at front of lot
Occupancy Inspection - Codes Residential Failed 9/30/2022 9/30/2022 09/30/2022
Miscellaneous Correction
Corrective Action Required
09/30/2022
- final grading and sod - Splash blocks - Guard required front porch, over 30” from grade - Multiple switch and outlet covers missing - Add gravel to egress window well - Egress ladder first step to be no more than 18” - Sump discharge minimum of 36” from foundation
Occupancy Inspection - Codes Residential Ready for Temp CO 10/4/2022 10/4/2022 10/04/2022
Miscellaneous Correction
Corrective Action Required
09/30/2022
- final grading and sod - Splash blocks - install irigation system
Occupancy Inspection - Codes Residential Temporary C of O 10/5/2022 10/05/2022
Miscellaneous Correction
Corrective Action Required
10/04/2022
- final grading and sod - Splash blocks - install irigation system
Plot Plan Inspection Passed 10/25/2022 10/25/2022
Erosion Control Inspection Residential Passed 10/25/2022 10/25/2022
DCM2 ESC DEFICIENT INSTALLATION
Resolved
10/25/2022
Occupancy Inspection - Codes Residential Full C of O 10/25/2022 10/25/2022 10/25/2022
Miscellaneous Correction
Resolved
10/25/2022
Documents & Images
Date Uploaded File Type Document Name
09/03/2021 Application Form APPLICATION
09/03/2021 Letter EXCISE TAX FORM
09/07/2021 Permit Codes Residential Plan Review
09/07/2021 Approved Plans APPROVED DRAWINGS
09/08/2021 Plot Plan APPROVED PLOT PLAN
09/08/2021 Permit Codes Residential Plan Review
09/10/2021 Permit DS Building Permit
09/10/2021 Receipt Receipt for transaction: 2021-007256
10/05/2021 M L Crose 3238 SW Pergola Park Dr LSMO Permit 2021-4505 3rd Party Footing Inspection Report 9-23-21
10/07/2021 Letter INSPECTION SUMMARY
10/12/2021 Letter INSPECTION SUMMARY
10/15/2021 Water meter pit.jpeg
10/15/2021 Letter INSPECTION SUMMARY
10/15/2021 Letter INSPECTION SUMMARY
10/22/2021 Letter INSPECTION SUMMARY
03/11/2022 Letter Codes 140 Day Letter
03/17/2022 Letter INSPECTION SUMMARY
04/20/2022 Letter INSPECTION SUMMARY
04/20/2022 Letter INSPECTION SUMMARY
04/20/2022 Letter INSPECTION SUMMARY
04/20/2022 Letter INSPECTION SUMMARY
04/25/2022 Letter INSPECTION SUMMARY
04/25/2022 Letter INSPECTION SUMMARY
04/25/2022 3238 SW Pergola Park Drive - Structural Letter
04/26/2022 Letter INSPECTION SUMMARY
05/24/2022 Letter INSPECTION SUMMARY
05/24/2022 Letter INSPECTION SUMMARY
08/23/2022 Letter INSPECTION SUMMARY
09/19/2022 Letter INSPECTION SUMMARY
09/26/2022 Letter INSPECTION SUMMARY
09/30/2022 Letter INSPECTION SUMMARY
09/30/2022 Letter INSPECTION SUMMARY
09/30/2022 Letter INSPECTION SUMMARY
09/30/2022 Letter INSPECTION SUMMARY
09/30/2022 Letter INSPECTION SUMMARY
10/04/2022 Receipt Receipt for transaction:2022-008030
10/05/2022 Certificate/License Codes Temporary Certificate of Occupancy
10/25/2022 Letter INSPECTION SUMMARY
10/25/2022 Letter INSPECTION SUMMARY
10/25/2022 Letter Field Certificate of Occupancy
10/25/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home